  • Zooper OPT1/4, Optima USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-110 PAGE 20 Issue: 1.1 Authorised: GH Date: 15/03/2004 I/we being the competent person(s) responsible (as indicated by my/our signatures below) for the installation of the fire alarm system, particulars of which are set out below, CERTIFY that the said installation for which I/we have been responsible complies to the best of my/our knowledge and belief with the specifications described below, and with the recommendations of BS5839-1:2002, except for the variations, if any, stated in this certificate Name (in block letters): Position: Signature: Date: Fo

  • Optima USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-110 PAGE 22 Issue: 1.1 Authorised: GH Date: 15/03/2004 I/we being the competent person(s) responsible (as indicated by my/our signatures below) for the acceptance of the fire alarm system, particulars of which are set out below, ACCEPT the system on behalf of: Name (in block letters)

  • Zooper OPT1/4, Optima USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-110 PAGE 10 Issue: 1.1 Authorised: GH Date: 15/03/2004 7. DISABLEMENTS 7.1 REASONS FOR DISABLING CERTAIN PARTS OF A FIRE ALARM SYSTEM. Certain parts of this Fire Alarm Panel can be temporarily disabled (i.e. switched off) to suit prevailing conditions. For example, if there is a risk of a False Alarm in a zone, for example, from vehicle exhaust smoke in a loading bay, it is possible for the user to disable that zone during the risk period and then enable it again afterwards. During a disablement of a zone(s), no fire or fault signal will be processed for that zone(s). Only zo

  • Zooper OPT1/4, . USER MANUAL, MAINTENANCE GUIDE & LOG BOOK FIRE ALARM CONTROL PANEL COMPLIES WITH EN54 part 2 & part 4 MEETS THE FUNCTIONAL REQUIREMENT OF BS:EN 5839 part 1

  • Zooper OPT1/4, Optima USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-110 PAGE 3 Issue: 1.1 Authorised: GH Date: 15/03/2004 1. FIRE ALARM CONTROL PANEL SAFETY ISSUES There is no need to open this fire alarm during normal operation. Any work carried out on this system must be performed by a competent person who is familiar with this type of system. This equipment will operate safely provided it has been installed correctly in compliance with the Installation Manual. It is recommended that the system is serviced frequently. It is customary to arrange a regular maintenance contract with a compete

  • Zooper OPT1/4, Optima USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-110 PAGE 4 Issue: 1.1 Authorised: GH Date: 15/03/2004 3. USER RESPONSIBILITIES & MAINTAINENCE OF THE FIRE ALARM SYSTEM, INCLUDING THE FACP & ITS INTEGRAL PSE According to the British Standard Code for Fire Detection and Alarm Systems for Commercial Buildings (BS5839: Pt 1: 2002), the owner or person having control of the premises should appoint a responsible person to oversee the effective operation of the Fire Alarm System (Clause 47.1). Below is a summary of the

  • Zooper OPT1/4, Optima USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-110 PAGE 5 Issue: 1.1 Authorised: GH Date: 15/03/2004 4. PANEL INDICATIONS & CONTROLS FIRE / ZONES ZONE FAULT / DISABLEMENT / TEST 12345678 12345678 POWER GEN FIRE GEN FAULT SYS FLT FLT SUPPLY FLT GEN S/C DEL FLT GEN TEST GEN DISABLEMENT ON OFF 1 2 3 4 5 6 Operating Instructions Normal Operation: Under normal conditions, the system will be silent and the green "POWER" LED will be on. Fire Condition: In a fire condition, the "GEN FIRE" LED and the specific zones(s) "FIRE" LED will be on and the

  • Zooper OPT1/4, Optima USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-110 PAGE 12 Issue: 1.1 Authorised: GH Date: 15/03/2004 9. SYSTEM DESCRIPTION FIRE ALARM SYSTEM SUMMARY: FIRE ZONE INFORMATION ZONE NUMBER ZONE DESCRIPTION A brief description of all the rooms and areas contained in each zone QTY SNDR QTY MCP QTY HEADS 1 2 3 4 5 6 7 8

  • Zooper OPT1/4, Optima USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-110 PAGE 8 Issue: 1.1 Authorised: GH Date: 15/03/2004 6. THE FAULT CONDITION 6.1 DIFFERENT TYPES OF FAULT The fire alarm monitors itself, and any equipment connected to it, for any faults that can occur. If a fault occurs, the Panel responds by activating its Internal buzzer and lighting the General Fault light and any other Fault light(s) relevant to the particular fault. The Panel’s Fault relay will also activate. Typical faults are described below: - Genera

  • Zooper OPT1/4, Optima USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-110 PAGE 2 Issue: 1.1 Authorised: GH Date: 15/03/2004 CONTENTS 1. FIRE ALARM CONTROL PANEL SAFETY ISSUES……………………………………… 3 How to use this Fire Alarm Panel safely 2. THE PURPOSE OF A FIRE ALARM SYSTEM……………………………………………… 3 Introduction to fire alarms 3. USER RESPONSIBILITIES & MAINTAINENCE OF THE FIRE ALARM SYSTEM, INCLUDING THE FACP & ITS INT

  • Zooper OPT1/4, Optima USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-110 PAGE 14 Issue: 1.1 Authorised: GH Date: 15/03/2004 MAINTENANCE WORK DATE TIME ZONE / LOCATION REASON FOR WORK WORK CARRIED OUT ADDITIONAL WORK REQUIRED SIGNED

  • Zooper OPT1/4, Optima USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-110 PAGE 9 Issue: 1.1 Authorised: GH Date: 15/03/2004 6.2 WHAT TO DO IF A FAULT CONDITION OCCURS If a fault occurs, the responsible person should: • Turn keyswitch to Controls enabled and press silence flt tone button (button 2) to silence the fault buzzer. • Write down the fault (s) in the Log Book at the back of this Manual. Take appropriate action to correct the fault (Usually by contacting the service engineer) On the Optima pan

  • Zooper OPT1/4, Optima USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-110 PAGE 6 Issue: 1.1 Authorised: GH Date: 15/03/2004 4.3 SUMMARY OF LED COMBINATIONS AND THEIR MEANING Use the table below to determine the condition of the panel. LEDs LIT LED CONDITION PANEL STATUS POWER CONSTANT GREEN The panel is supplied with power, and has no faults / fires (System Normal) GEN FLT ONLY CONSTANT YELLOW Problem with keyswitch connections GEN FLT & SUPPLY FLT CONSTANT YELLOW FLASHING YELLOW There is a problem with either the mains supply or the battery backup GEN FLT & EARTH FLT CONSTANT YELLOW FLASHING YELLOW There is a wi

  • Optima USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-110 PAGE 7 Issue: 1.1 Authorised: GH Date: 15/03/2004 5. THE FIRE CONDITION 5.1 HOW THE OPTIMA INDICATES AN ALARM FIRE / ZONES ZONE FAULT / DISABLEMENT / TEST 123 45678 123 45678 POWER GEN FIRE GEN FAULT SYS FLT FLT SUPPLY FLT GEN S/C DEL FLT GEN TEST GEN DISABLEMENT 1 2 3 4 5 6 t i m a F

  • Optima USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-110 PAGE 21 Issue: 1.1 Authorised: GH Date: 15/03/2004 I/we being the competent person(s) responsible (as indicated by my/our signatures below) for the commissioning of the fire alarm system, particulars of which are set out below, CERTIFY that the said wor

  • Zooper OPT1/4, Optima USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-110 PAGE 13 Issue: 1.1 Authorised: GH Date: 15/03/2004 10. FIRE ALARM LOG BOOK It is recommended that this LOG BOOK section of the Manual be maintained by the responsible person(s) on site, who should ensure every event is properly recorded (including fire alarm conditions, failures, tests, temporary disconnections, disablements, enablements, dates of installing engineers’ visits together with a note of any outstanding work or p

  • Zooper OPT1/4, Optima USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-110 PAGE 16 Issue: 1.1 Authorised: GH Date: 15/03/2004 ALL EVENTS OTHER THAN MAINTENANCE WORK OR FALSE ALARMS DATE TIME ZONE / LOCATION DETAILS OF EVENT (INCLUDING CAUSE IF KNOWN) ACTION REQUIRED DATE COMPLETED INITIALS

  • Zooper OPT1/4, Optima USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-110 PAGE 17 Issue: 1.1 Authorised: GH Date: 15/03/2004 11 COMMISSIONING THE SYSTEM, INCLUDING P.S.E. • The commissioning of this fire alarm system should be performed by a qualified commissioning engineer, who has an understanding of sections 2,3,& 4 of BS5839 pt 1:2002 (i.e. Design considerations, Limitations of false alarms, Installation recommendations) • The system layout drawing should be checked for accuracy &am

  • Zooper OPT1/4, Optima USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-110 PAGE 15 Issue: 1.1 Authorised: GH Date: 15/03/2004 FALSE ALARMS DATE TIME ZONE / LOCATION CAUSE (IF KNOWN) OR ACTIVITIES IN ALARM AREA MAINTENANCE VISIT NEEDED (YES/NO) MAINTENANCE FINDINGS CATEGORY OF FALSE ALARM FURTHER ACTION REQUIRED SIGNED

More Instructions:

DOWNLOAD

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 HPI Racing crawler King Instruction manual hpi-racing/crawler-king-886.pdf 03 May 2023 40
2 Zoom 3005 Specification sheet zoom/3005-3A2.pdf 10 Apr 2023 2 0.06 Mb
3 LG WM1832C Owner's manual lg/wm1832c-SW7.pdf 11 Sep 2023 24
4 Lasko 4000 Important instructions & operating manual lasko/4000-N69.pdf 27 Mar 2023 4
5 Mangrove Jack's Kegerator Series User manual and assembly instructions mangrove-jacks/kegerator-series-Z38.pdf 01 Sep 2022 12
6 JVC KD-R980BTS Instruction manual jvc/kd-r980bts-Q56.pdf 11 Aug 2023 108

Similar Resources:

  • Red Smoke Alarms

    R240

    (2 pages)
    Specifications:SMOKE ALARM R240240 V a.c, Mains Power Photoelectric Smoke Alarm with 9V Battery BackupINSTALLATION INSTRUCTIONS55mmPLEASE NOTE: READ ALL INSTRUCTIONS BEFORE INSTALLATION. NO USER SERVICEABLE PARTS INSIDE THIS SMOKE ALARM.Main Power SourceBackup BatteryOperating CurrentSensing TypeTemperature RangeHumidity RangeInterconnectingTerminalsSound L …
  • Incite Fire

    ekho EK-WL8-HS/AU

    (8 pages)
    EK-WL8-HS/AU WIRELESS HEAT DETECTOR WITH BUILD-IN SOUNDER STFV.425238.038-AU-UM rev. 18 20.08.2020 Page 1 from 8 GENERAL DESCRIPTION EK-WL8-HS/AU is a wireless 2-in-1 device equipped with a heat detector and a sounder. The device analyzes physical factors associated with fire and the way these factors change through time. An alarm signal is gene …
  • Ksenia

    nebula KSF5100001.001

    (2 pages)
    Sensore ottico di fumo (filare) - Manuale di installazioneOptical smoke detector (wired) - Installation guideDétecteur optique de fumée (filaire) - Guide d’installationKSF5100001.001 glass design KSF5100001.003 mesh designnebulaINTRODUZIONE - INTRODUCTION - INTRODUCTIONI rilevatori di fumo nebula sono dispositivi ottici che consentono di segnalare la …
  • Klaxon

    Nexus 120 AC

    (7 pages)
    Klaxon Signals Ltd, Oldham, OL4 1HW, UKPhone +44 161 287 5555 Fax +44 161 287 5511E-mail [email protected] 4 (June 2008) 18-186461Copyright © Klaxon Signals Ltdwww.klaxonsignals.comTone Tone Type Tone Description / Application Dip Switch 3rd Stage Peak Sound(S1/S2) Tone Level (dBA@1m)1. 970Hz (BS5839-1:2002) O-O-O-O-O-O 18 1182. 800Hz/970Hz @ 2Hz …
  • GST

    I-9301

    (2 pages)
    30308778 Issue 1.06 Features  Two-wire and four-wire modes can be programmed through hand held programmer.  Electronic address can be modified in field.  Built-in MCU processes messages intelligently.  Monito …
  • Alecto

    SA-210

    (18 pages)
    GEBRUIKSAANWIJZING - NLMODE ÉMPLOI - FRGEBRAUCHSANWEISUNG - DMANUAL - ENINSTRUCCIONES - ESSA-210Rookmelder voor gebruik in huiselijke omgevingDétecteur de fumée pour l’usage dans l’entourage domestiqueRauchmelder zum Gebrauch im HeimbereichSmoke detector for domestic useDetector de humo para uso en el hogar …

Comments, Questions and Opinions: