  • Delta ShopMaster A05581, 8- ENG A05581 GLOSSARY Become familiar with these terms before operating the unit. CFM: Cubic feet per minute. SCFM: Standard cubic feet per minute; a unit of measure of air delivery. PSIG: Pounds per square inch gauge; a unit of measure of pressure. Code Certification: Products that bear one or more of the following marks: UL, CUL, ETL, CETL, CSA/US have been evaluated by OSHA certified independent safety laboratories and meet the applicable Underwriters Laboratories Standards for Safety. CSA: Electrical products sold in Canada are required to be certified to the applicable CSA standard

  • Delta ShopMaster A05581, 4- ENG A05581 WARNING: Risk of Bursting Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury. How To Prevent It What Could Happen WARNING: Risk from Flying Objects HOW TO PREVENT IT WHAT CAN HAPPEN The compressed air stream can cause soft tissue damage to exposed skin and can propel dirt, chips, loose particles, and small objects at high speed, resulting in property damage or personal injury. Always wear ANSI Z87.1 approved safet

  • Delta ShopMaster A05581, 26- SP A05581 Familiarícese con los siguientes términos, antes de operar la unidad: CFM: (Cubic feet per minute) Pies cúbicos por minuto. SCFM: (Stardard cubic feet per minute) Pies cúbicos estándar por minuto; una unidad de medida que permite medir la cantidad de entrega de aire. PSIG: (Pound per square inch) Libras por pulgada cuadrada. Código de certificación: Los productos que usan una o más de las siguientes marcas: UL, CUL, ETL, CETL, CSA/US han sido evaluados por OSHA, laboratorios independientes certificados en seguridad, y reúnen los estándares suscriptos por los laborator

  • 22- SP A05581 PELIGRO ADVERTENCIA: RIESGO DE EXPLOSIÓN TANQUE DE AIRE: LAS SIGUIENTES CONDICIONES PODRÍAN, CAUSAR EL DEBILITAMIENTO DEL TANQUE, Y DETERMINAR SU EXPLOSIÓN VIOLENTA, DAÑOS A LA PROPIEDAD O SERIAS LESIONES. Para un control esencial de la presión, debe usted instalar un regulador y un medidor de presión a la salida del aire de su compresor. (Si no estuviese equipado) Siga l

  • Delta ShopMaster A05581, 28- SP A05581 Protección del voltaje y del circuito Acerca del voltaje y la mínima cantidad de circuitos requeridos, refiérase al Manual de piezas. Ciertos compresores de aire pueden ser operados en un circuito de 15 A, siempre que se cumplan las siguientes condiciones: 1. El voltaje de alimentación es de 108 V - 132 V CA en el tomacorriente. 2. Que el circuito no sea utilizado para alimentar ninguna otra necesidad eléctrica (iluminación, artefactos, etc.) 3. El circuito está equipado con un interruptor de circuito de 15 A mínimo, o con un fusible de 15 A de acción retardada. NOTA: Si el compresor es

  • Delta ShopMaster A05581, 39- FR A05581A05581 AVERTISSEMENT: RISQUE D’EXPLOSION OU D’INCENDIE PRÉVENTION RISQUE DANGER LES ÉTINCELLES QUI PROVIENNENT DES CONTACTS ÉLECTRIQUES DU MOTEUR ET DU MANOSTAT SONT CONSIDÉRÉES NORMALES. SI DES ÉTINCELLES ÉLECTRIQUES DU COMPRESSEUR ENTRENT EN CONTACT AVEC DES VAPEURS INFLAMMABLES, ELLES PEUVENT S’ENFLAMMER, PROVOQUANT UN INCENDIE OU UNE EXPLOSION. TOUTE OBSTRUCTION DES ORIFICES D’AÉRATION DU COMPRESSEUR ENTRAÎNERA UNE SURCHAUFFE DANGEREUSE ET RISQUE DE CAUSER UN INCENDIE. SI CET APPAREIL FONCTIONNE SANS SUPERVISION, CELA RISQUE DE CAUSER DES BLESSURES GRAVES OU DES DOMMAGES À LA

  • Delta ShopMaster A05581, 31- SP A05581 Cómo poner en marcha: 1. Mueva el interruptor Auto/On/Off a la posición "AUTO/ON" y deje incrementar la presión del tanque. El motor se detendrá una vez alcanzado el valor de presión "de corte" del tanque. 2. Gira la perilla del regulador en sentido horario hasta lograr la presión deseada. El compresor estará listo para ser usado. NOTA: Opere siempre el compresor de aire en áreas bien ventiladas, libres de gasolina u otras emanaciones combustibles. Si el compresor

  • Delta ShopMaster A05581, 23- SP A05581 PELIGRO PELIGRO ADVERTENCIA: RIESGO DE INHALACIÓN ADVERTENCIA: RIESGO DE DESCARGA ELÉCTRICA Su compresor de aire está accionado por electricidad. Como cualquier otro dispositivo eléctrico impulsado eléctricamente, si no se lo utiliza adecuadamente, podría causarle una descarga eléctrica. ¿CÓMO PREVENIRLO? ¿QUÉ PUEDE OCURRIR? ¿CÓMO PREVENIRLO? ¿QUÉ PUEDE OCURRIR? Trabaje en un área con buena ventilación cruzada. Lea y siga las instrucciones de seguridad provistas en el rótulo o en los datos de las hojas de seguridad del

  • Delta ShopMaster A05581, 11- ENG A05581 OPERATION Know Your Air Compressor READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference. Description of Operation Become familiar with these controls before operating the unit. Auto/On/Off Switch: Set switch in AUTO/ON position to provide automatic power to the pressure switch and OFF to remove power at the end of each use. Pressure Switch (not shown): The pressure switch automatically starts the motor when the air tank pressure drops below

  • 46- FR A05581 Protection contre la surtension et protection du circuit Consulter le Guide des pièces pour connaître les exigences minimums concernant la tension et le circuit de dérivation. Certains modèles de compresseur d'air peuvent fonctionner sur un circuit de 15 ampères si les conditions suivantes sont satisfaites : 1. la tension de sortie est de 1

  • Delta ShopMaster A05581, 40- FR A05581A05581 AVERTISSEMENT: RISQUE D’ÉCLATEMENT RÉSERVOIR D’AIR : LES CONDITIONS SUIVANTES PEUVENT AFFAIBLIR LES PAROIS DU RÉSERVOIR ET PROVOQUER UNE EXPLOSION VIOLENTE DU RÉSERVOIR QUI RISQUE DE CAUSER DES DOMMAGES À LA PROPRIÉTÉ OU DES BLESSURES GRAVES. 1. LE DÉFAUT DE VIDANGER DE FAÇON APPROPRIÉE L’EAU CONDENSÉE DANS LE RÉSERVOIR RISQUE DE CAUSER LA ROUILLE ET L’AMINCISSEMENT DES PAROIS EN ACIER DU RÉSERVOIR. 2. DES MODIFICATIONS OU TENTATIVES DE RÉPARATION FAITES SUR LE RÉSERVOIR. 3. DES MODIFICATIONS NON AUTORISÉES APPORTÉES À LA SOUPAPE DE DÉCHARGE, À LA SOUPAPE DE

  • 44- FR A05581A05581 LEXIQUE Veuillez vous familiariser avec ces termes avant d'utiliser l'appareil. CFM : pieds cubes par minute (pi 3 /min). SCFM : pieds cubes par minute (pi 3 /min) standard. Une unité de mesure de débit d'air. PSIG: jauge indiquant le nombre de livres par pouce carré (lb/po 2 ). Une unité de mesure de pression. ASME : American Society of Mecha

  • Delta ShopMaster A05581, 53- FR A05581 PROBLÈME CAUSE CORRECTION Le moteur ne tourne pas. Fusible sauté ou coupe-circuit déclenché. Rallonge de longueur ou de calibre inapproprié. Moteur défectueux. Vérifiez s'il y a un fusible sauté dans la boîte à fusibles et remplacez-le au besoin. Rétablissez le coupe-circuit. Ne pas utiliser un fusible ou un coupe- circuit à valeur nominale supérieure à la valeur spécifiée pour le circuit de dérivation utilisé. Vérifier si le fusible est du type approprié. Vous devriez utiliser un fusible retardé. Vérifier s'il y a une condition de tension basse. Vérifiez la rallonge. Déconne

  • Delta ShopMaster A05581, 14- ENG A05581 Before you store the air compressor, make sure you do the following: 1. Review the "Maintenance" section on the preceding pages and perform scheduled maintenance as necessary. 2. Set the Auto/On/Off lever to "OFF". 3. Turn regulator knob counterclockwise and set the outlet pressure to zero. 4. Remove the air tool or accessory. 5. Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi. Release safety valve ring. 6. Drain water from air tank by opening drain valve on bottom of tank. Water will condense in the air tank. If not d

  • Delta ShopMaster A05581, 32- SP A05581 Antes de guardar su compresor de aire, asegúrese de hacer lo siguiente: 1. Revise la sección "Mantenimiento" de las páginas precedentes y ejecute el mantenimiento programado de acuerdo a la necesidad. 2. Coloque la palanca Auto/On/Off en la posición "OFF". 3. Gire la perilla del regulador en sentido antihorario y calibre la presión de salida a cero. 4. Extraiga la herramienta neumática o el accesorio. 5. Tire del anillo de la válvula de seguridad permitiendo el

  • Delta ShopMaster A05581, INSTALLATION Location of the Air Compressor Locate the air compressor in a clean, dry and well ventilated area. The air compressor should be located at least 12" away from the wall or other obstructions that will interfere with the flow of air. The air compressor pump and shroud are designed to allow for proper cooling. The ventilation openings on the compressor are necessary to maintain proper operating temperature. Do not place rags or other containers on or near these openings. HOW TO SET UP YOUR UNIT 9- ENG A05581 GROUNDING INSTRUCTIONS RISK OF ELECTRICAL

  • Delta ShopMaster A05581, 36- SP A05581 GARANTÍA LIMITADA DELTA MACHINERY garantiza al comprador original de todos los productos cubiertos bajo esta garantía, que los mismos se encuentran libres de defectos en materiales y mano de obra. Los productos cubiertos bajo esta garantía incluyen todos los compresores de aire, herramientas neumáticas, piezas de servicio, lavadoras a presión y generadores, los cuales tienen los siguientes periodos de garantía: 3 AÑOS – Garantía limitada en las bombas compresoras de 2 tiempos sin aceite, que operan a 17

  • Delta ShopMaster A05581, 41- FR A05581A05581 DANGER AVERTISSEMENT: RISQUE DE CHOC ÉLECTRIQUE NE JAMAIS FAIRE FONCTIONNER LE COMPRESSEUR À L’EXTÉRIEUR LORSQU’IL PLEUT OU DANS DES CONDITIONS HUMIDES. NE JAMAIS FAIRE FONCTIONNER LE COMPRESSEUR SANS LES COUVERCLES DE PROTECTION OU LORSQUE CEUX-CI SONT ENDOMMAGÉS. TOUT CÂBLAGE ÉLECTRIQUE OU TOUTE RÉPARATION REQUIS SUR CET APPAREIL DEVRAIT ÊTRE EFFECTUÉ PAR LE PERSONNEL D’UN CENTRE DE SERVICE APRÈS-VENTE AUTORISÉ, CONFORMÉMENT AUX CODES ÉLECTRIQUES NATIONAUX ET LOCAUX. S’ASSURER QUE LE CIRCUIT ÉLECTRIQUE ALIMENT

  • Delta ShopMaster A05581, 13- ENG A05581 MAINTENANCE Customer Responsibilities Daily or after each use Before each use Check Safety Valve ● Drain Tank ● To Check Safety Valve If the safety valve does not work properly, over- pressurization may occur, causing air tank rupture or an explosion. Before starting compressor, pull the ring on the safety valve to make sure that the safety valve operates freely. If the valve is stuck or does not operate smoothly, it must be replaced with the same type of valve. To Drain Tank 1. Set the Auto/On/Off switch to "OFF". 2. Turn regulator knob counterclockwise to set the outlet pressure to zero. 3. Remove the air tool or accessory. 4. Pull ring o

  • Delta ShopMaster A05581, 51- FR A05581 DÉPANNAGE En effectuant des réparations au compresseur, il se peut que vous soyez exposé aux sources de tension, aux pièces mobiles ou aux sources d'air comprimé qui risquent de causer des blessures corporelles. Débranchez le compresseur et purgez l'air pressurisé du réservoir avant d'entamer toute réparation. PROBLÈME CAUSE CORRECTION Le manostat n’arrête pas le moteur lorsque le compresseur d'air atteint la "pression de rupture". La "pression de rupture" du manostat est trop élevée. Déplacez le levier "

  • 45- FR A05581A05581 INSTALLATION Emplacement du compresseur d'air Le compresseur d'air doit être situé dans un endroit propre, sec et bien aéré. Le compresseur d'air doit être situé à une distance d'au moins 12 po (30 cm) du mur ou de toute autre obstruction qui pourrait nuire au débit d'air. La pompe et la tôle de protection du compresseur sont conçu

  • Delta ShopMaster A05581, PART NO. A05581 Rev. 0 6/04 Copyright © 2004 Delta Machinery Compresor de Aire Sin Aceite (CP201) Para saber más acerca de las MÁQUINAS DELTA, visite nuestro sitio WEB en: www.deltamachinery.com. Por piezas, servicio garantía y cualquier otro tipo de asistencia, sírvase llamar al: 1-866-422-4286 ENGLISH: PÁGINA 1 FRANÇAIS: PAGE 37 Manual de Instrucciones

  • Delta ShopMaster A05581, 27- SP A05581 INSTALACIÓN Ubique el compresor de aire en una zona limpia, y bien ventilada. El compresor de aire debe quedar separado - por lo menos - a 12 plug (30 cm) de la pared u otro tipo de obstrucciones que pudiesen interferir el flujo del aire. La bomba del compresor de aire y la carcasa están diseñadas para permitir el enfriamiento correcto. Las aberturas de ventilación del compresor son necesarias para mantener una adecuada temperatura de funcionamiento. No coloque trapos ni objetos en las proximidades de dichas aberturas. CÓMO PREPARAR LA UNIDAD INSTRUCCIONES PARA CONECTAR A TIERRA R

  • Delta ShopMaster A05581, 12- ENG A05581 Before Starting Break-in Procedure Serious damage may result if the following break-in instructions are not closely followed. This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced. 1. Make sure the Auto/On/Off switch is in the "OFF" position. 2. Plug the power cord into the correct branch circuit receptacle. (Refer to Voltage and Circuit Protection paragraph in the Installation section of this manual.) 3. Open the drain valve fully (counterclockwise) to permit air to escap

  • Delta ShopMaster A05581, 16- ENG A05581 PROBLEM CAUSE CORRECTION It is normal for "some" pressure drop to occur. If there is an excessive amount of pressure drop when the accessory is used, adjust the regulator following the instructions in the "Description of Operation" paragraph in the "Operation Section. NOTE: Adjust the regulated pressure under flow conditions (while accessory is being used). Compressor is not supplying enough air to operate accessories. Prolonged excessive use of air. Compressor is not large enough for air requirement. Hole in

  • 17- ENG A05581 PROBLEM CAUSE CORRECTION Motor will not run. Check fuse box for blown fuse and replace as necessary. Reset circuit breaker. Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch circuit. Check for proper fuse. You should use a time delay fuse. Check for low voltage problem. Check the extension cord. Disconnect the ot

Related Products and Documents (Air Compressor):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Lifegard Big Digital Temp Alert Operating instructions lifegard/big-digital-temp-alert-6NA.pdf 08 Nov 2023 2
2 Epson TM-T88III series Operation & user’s manual epson/tm-t88iii-series-E9Y.pdf 29 Jul 2023 32
3 Boston Acoustics XB6 Operation & user’s manual boston-acoustics/xb6-3EC.pdf 09 Mar 2023 24 0.95 Mb
4 Medialink MWN-WAPR150N Questions medialink/mwn-wapr150n-3QN.pdf 11 May 2023 15
5 Alamo Industrial Hydraulic Flex Wing Cutter Falcon 10 - 15 Parts manual alamo/hydraulic-flex-wing-cutter-falcon-10-15-2QX.pdf 26 Nov 2023 76 25.5 Mb
6 D-Link DSP-W115 Quick start manual d-link/dsp-w115-F1E.pdf 05 Feb 2024 80

Similar Resources:

  • MasterFlow

    MF-1040

    (2 pages)
    2018 Edition MF-1040 Portable Air Compressor Owner’s Manual PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATING YOUR COMPRESSOR. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE BEFORE OPERATING THE UNIT, IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT US ONLY YOU CAN PREVENT INJURIES MasterFlowAir.com DESCRIPTION: This inflator is designed to inflate truck, …
  • EUFAB

    21068

    (12 pages)
    REIFENDICHTMITTELWARNUNGLesen Sie die Bedienungsanleitung vor Inbetriebnahme sorgfältig durch und beachten Sie alle Sicherheitshinweise! Nichtbeachtung kann zu Personenschäden, Schäden am Gerät oder Ihrem Eigentum führen! Bewahren Sie die Originalverpackung, den Kaufbeleg sowie diese Anleitung zum späteren Nachschlagen auf! Bei der Weitergabe des Produ …
  • Scheppach

    HC24V

    (36 pages)
    HC24VNachdrucke, auch auszugsweise, bedürfen der Genehmigung. Technische Änderungen vorbehalten. Abbildungen beispielhaft!Art.Nr.5906117904AusgabeNr.5906117852Rev.Nr.01/04/2020DEKompressorOriginalbedienungsanleitung4GBCompressorTranslation of original instruction manual14FRCompresseurTraduction des instructions d’origine22 …
  • SchraderAir

    SA315240H346

    (14 pages)
    Compressor Operating and Maintenance Manual TWO STAGE 15 HP PUMP MODEL: _________________________ SERIAL #_________________________ …
  • Ingersoll-Rand

    Doosan C185WKUB-T2 Export

    (56 pages)
    Doosan Infracore Portable Power 1293 Glenway DriveStatesville, N.C. 28625www.doosanportablepower.comBook: 46555713 (1-28-2011) Rev B This manual contains important safety information.Do not destroy this manual.This manual must be available to the personnel who operate and maintain this machine. OPERATION, MAINTENANCE, COMPRESSOR MODELC185WKUB-T2 …
  • Harbor Freight Tools

    38898

    (9 pages)
    4 Gallon, 2 HP PeakPancake CompressorModel 38898ASSEMBLY and OPERATING INSTRUCTIONSCopyright© 1999 by Harbor Freight Tools®. All Rights Reserved.No portion of this manual or any artwork contained herein may be reproducedin any shape or form without the express written consent of Harbor Freight Tools.For technical questions and replacement parts, please cal …

Comments, Questions and Opinions: