  • Delta Electronics Ethernet Communication Module DVPEN01-SL, Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 44 3. In “Subject and Mail” page, enter the address of SMTP server, subject of E-Mail, and E-mail address of the recipient. 4. Switch to “Select Recipients” page. Check all the boxes of “Recipient 1”. Click on “OK” to complete the setting.

  • Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 13 registers (CR) in the extension module. Numbering of the modules: Every extension module connected to PLC MPU has a No. to allow you to know which module is which when compiling the PLC program. The first extension module attached at the left hand side of the PLC MPU is numbered as K100, the s

  • Delta Electronics Ethernet Communication Module DVPEN01-SL, Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 12 CR#116: Modbus TCP Status Explanations: Displaying the current communication status of Modbus TCP mode. When the CR value is set as”0” Æ the data have not yet been received; when the CR value is set as “1” Æ the data exchange is in progress; when the CR value is set as “2” Æ the data exchange is successful; when the CR value is set as “3” Æ the data exchange fails. CR value Data exchange status 0

  • Delta Electronics Ethernet Communication Module DVPEN01-SL, Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 15 3. Searching by IP address • Set the transmission type as “Ethernet” first. Next click on the “Static IP Search” icon (circled) to search for the designated IP. • Press the “search” icon and you will open the window for entering the IP address. Enter the IP of DVPEN01-SL you would like to search in the IP address column, or click on the IP address in the IP list. Press “OK" to start the searching. • The DVPEN01-SL searched is displayed in the left c

  • Delta Electronics Ethernet Communication Module DVPEN01-SL, Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 48 Explanations: • The data exchange will be executed every one second. • Write “0” into CR#28, and PLC_B will use CR#25 ~ CR#26 as the IP address of the destination PLC. • Write the IP address of PLC_A into CR#25 and CR#26. The first two IP codes (192.168 = H’C0A8) should be written into CR#26, and the last two IP codes (0.4 = H’0004) into CR#25. • Write the data in RTC into CR#29 ~ CR#35. • Write “1” into CR#13 to start the data exchange. • CR#14 = 2 refers to successful execution. CR#14 = 3 refers to failed execution.

  • Delta Electronics Ethernet Communication Module DVPEN01-SL, Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 38 4. Open the setup page again, and DVPEN01-SL is now locked by the password. You cannot open any of the settings now. Click on “Unlock” to leave the entering password window. 5. Enter the password to temporarily unlock the protection and modify the parameters. If you close the setup page, the locking will automatically be recovered.

  • Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 45 5. After all the settings in DVPEN01-SL are completed, compile the ladder diagram in the MPU and download it to the MPU. See below for the program design: END X0 T0 K100 K3 K1 K4 K5 K6 K1 X0 T0 K100 K1 K1 T0 K100 K1 K1 T0 K100 K1 K1 Y0 Y0 Explanations: • If the rising-edge of X0 is triggered, X0

  • Delta Electronics Ethernet Communication Module DVPEN01-SL, Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 49 END SET M2 M1RST K100 K1 M2 K14 D14 RST M2 RST M2 = D14 K2 = D14 K3 FROM K100 K1TOP K100TOP K1 K1 K0K14 K13 K100TOP K1 K86 H1064 Explanations: • The data exchange will be executed every one second. • Write “0” into CR#28, and PLC_B will use CR#25 ~ CR#26 as the IP address of the destination PLC. • Write the IP address of PLC_A into CR#25 and CR#26. The first two IP codes (192.168 = H’C0A8) should be written into CR#26, and the last two IP codes (0.4 = H’0004) into CR#25. • Write the Modbus address of D0 (H’1000) in PLC_A into CR#81 and CR#84. • Write the Mo

  • Delta Electronics Ethernet Communication Module DVPEN01-SL, Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 39 6. To clear the password, simply leave the password columns blank. Click on “OK” to clear the password. 7. After the password is cleared, you can modify the parameters. 6.5 When the Password is Lost (Returning to Default Setting by RS-232) Application Returning to default setting by RS-232 Network requirement (1) DVPEN01-SL is set with a password. (2) The password is forgotten. 1. Use DVPACAB2A30 cable to connect the PC and DVPEN01-SL and open

  • Delta Electronics Ethernet Communication Module DVPEN01-SL, Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 5 2.3 LED Indicators Indicator Color Indication POWER Green Power indication RS-232 Red Communication status of the series port 100M Orange Network connection status LINK Green Network communication speed 2.4 RJ-45 PIN Definition RJ-45 sketch Terminal No. Definition Explanation 1 Tx+ Positive pole for data transmission 2 Tx- Negative pole for data transmission 3 Rx+ Positive pole for data receiving 6 Rx- Negative pole for data receiving 4, 5, 7, 8 - N/C 3 Inst

  • Delta Electronics Ethernet Communication Module DVPEN01-SL, Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 8 CR# HW LW Attribute Content Explanation #119 R/W Modbus TCP data length Setting up the data length for Modbus TCP transaction #219 ~ #120 R/W Modbus TCP data buffer Data buffer of Modbus TCP for storing sending/receiving data #248 ~ #220 - Reserved #251 R Error code Displaying the errors. See table of error codes in the following section for more information. #255 ~ #252 - Reserved Symbols “R” re

  • Delta Electronics Ethernet Communication Module DVPEN01-SL, Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 32 8. Enter IP address: 192.168.0.4; Netmask: 255.255.255.0; Gateway: 192.168.0.1. Press “OK” to complete the setup, and WPLSoft will automatically search for DVPEN01-SL. 9. The IP of DVPEN01-SL has been modified into the new setting (DELTA DVPEN01-SL: 192.168.0.4). 10. Click on DELTA DVPEN01-SL, and WPLSoft will be able to communicate with the MPU. 6.2 Connecting the PC with DVPEN01-SL through LAN Application Setting up network parameters of DVPEN01-SL by WPLSoft through LAN. Network requirement (1) Connect the PC and DVPEN01-SL by using DHCP server through LAN. (2) IP of

  • Delta Electronics Ethernet Communication Module DVPEN01-SL, Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 27 Check “Default Setting” box and click on “Yes”. Note: If you set up DVPEN01-SL by RS-232, you can return the setting to default setting whether the password is locked or not. It takes approximately 10 seconds to return to default setting, so DO NOT switch off the power within the 10 seconds. 5.10 Export & Import of DVPEN01-SL Files After you set up all the settings in DVPEN01-SL, you can export you settings and save them into files. You can also

  • Delta Electronics Ethernet Communication Module DVPEN01-SL, Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 40 2. Check the “Default Setting” box and the “Warning” dialog box will appear. Click on “Yes” to return to default setting (in approx. 5 ~ 10 seconds), and the password will be cleared as well. 3. After the searching, all the parameters have already returned to their default settings. 6.6 IP Filter Protection Application Setting up IP filter protection Network requirement (1) IP of DVPEN01-SL: 192

  • Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 34 4. Click on “Auto-Search” icon to search for all DVPEN01-SL modules in the network. Follow “View Æ Workspace Æ Communication” or “View Æ Workspace Æ Project” to find the detected DVPEN01-SL module (default module name: DELTA DVPEN01-SL, IP: 192.168.1.5) in the window. 5. Design

  • Delta Electronics Ethernet Communication Module DVPEN01-SL, Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 35 6. Open the setup page. You can modify the module name for easier identification. 7. Next, set up the new IP of DVPEN01-SL. First switch to “Network” setup page. If there is a DHCP server in the LAN, select DHCP in “IP Configuration”. If there is no DHCP server in the LAN, you can set a static IP. Please be noted that the settings of subnet mask and gateway have to be the same as the settings in the same LAN. Press “OK” to complete the setting, and WPLSoft wi

  • Delta Electronics Ethernet Communication Module DVPEN01-SL, Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 3 1 Introduction Thank you for choosing DVPEN01-SL module. To correctly install and operate DVPEN01-SL, please read the manual carefully before using the module. DVPEN01-SL is an Ethernet communication module for remote setting and communication through WPLSoft. DVPEN01-SL is able to send E-mails, automatically correct the RTC in DVP28SV11R/T and exchange data. It supports Modbus TCP communication protocol and can conduct remote monitoring by using SCADA (Supervisor Control And Data Acqusition) software or HM

  • Delta Electronics Ethernet Communication Module DVPEN01-SL, Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 28 1. Export: Save all the settings of DVPEN01-SL into *.eni files. The exported files do not include the password. 2. Import: Select a file and the file will be imported to all the settings. 5.11 Recording IP Address When DVPEN01-SL is searching for a designated IP, there is a list for you to directly select and designate a module to be searched. “Recording IP address” function is to add a DVPEN01-SL module into the list for you to see the module in the searching. 

  • Delta Electronics Ethernet Communication Module DVPEN01-SL, Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 26 1. Modify: Check the box to modify the password. 2. New Password: Maximum 4 characters are allowed. Leave the column “blank” to disable the password protection function. 3. Confirm Password: Enter the new password again. 4. See “Application Examples Section 6.4” for more details. Note: After the password is locked, all the pages cannot be set up unless you unlock the password. However, if you set up DVPEN01-SL by RS-232, you can return the setting to default setting whe

  • Delta Electronics Ethernet Communication Module DVPEN01-SL, Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 20 IP Explanation Static The user enters the IP address, subnet mask and gateway. DHCP DHCP server offers the IP address, subnet mask and gateway. • IP address: IP address is the location of the equipment in the network. Every equipment connected to the network has to have an IP address. Incorrect IP address will result in connection failure on the equipment or even other equipment. Ask your ISP for questions about IP address setup. The default IP for DVPEN01-SL is 192.168.1.5. • Subnet mask: Subnet mask is an important parameter for setting up the subnet, used for seei

  • Delta Electronics Ethernet Communication Module DVPEN01-SL, Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 37 • Use TO instruction to write the network setting parameters D0 ~ D7 into CR#69 ~ #75 in DVPEN01-SL. DVPEN01-SL is the first extension module numbered K100 attached at the left hand side of PLC. (See 4.3 for more details.) • After the program is being executed, all the previous network settings in DVPEN01-SL will be modified into new settings. 3. If DVPEN01-SL is damaged, please change to a new DVPEN01-SL. The default IP for DVPEN01-SL is 192.168.1.5. 4. Execute STOP → RUN in the new DVPEN01-SL and search for it again. We can see

  • Delta Electronics Ethernet Communication Module DVPEN01-SL, Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 51 • Write the length of the instrcution into CR#119. • Write “1” into CR#115 to start the execution of Modbus TCP instrcution. • CR#116 = 2 refers to successful execution. CR#116 = 3 refers to failed execution. • If the execution is successful, Y0 on PLC_A will go between On and Off every one second.

  • Delta Electronics Ethernet Communication Module DVPEN01-SL, Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 16 4. Opening DVPEN01-SL setup page by RS-232` • Select “RS232" as the transmission type in communication setting. You will have to designate a communication port. When DVPEN01-SL is searched by RS-232, you do not need to set up the parameters (i.e. data length, parity, stop bits and baud rate). • After setting up the communication port, press “RS-232 search” icon (circled). If the searching is successful, the setup page for DVPEN01-SL will open automatically. 5.2 Basic Settings The basic settings include parameters as module name

  • Delta Electronics Ethernet Communication Module DVPEN01-SL, Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 9 CR value E-Mail status 10 Fail to connect to SMTP-Server 11 Incorrect recipient E-Mail address 12 SMTP-Server communication error 13 Exceeding the max. number of TCP connection 3 ~ 9, 14 ~ 255 Reserved CR#9 ~ 12: E-Mail 1 ~ 4 Additional Message Explanations: The user fills in the code, and the code will be stored in the title of the E-Mail and sent out with the E-Mail.  Data Exchange CR#13: Data Exchange Trigger Explanations: When the CR is set as “0”, the data in data exchange area will not be transmitt

Related Products and Documents (Network Card):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Smailo HD 4.3 Operation & user’s manual smailo/hd-4-3-XC9.pdf 10 May 2023 174
2 Panasonic KV-S1045C Operating manual panasonic/kv-s1045c-3P6.pdf 04 Sep 2022 51 1.51 Mb
3 Daewoo KOR-6L051A Operating instructions & cook book daewoo/kor-6l051a-118.pdf 15 Jan 2024 22 0.21 Mb
4 Clarion DB165 Owner's manual clarion/db165-RFP.pdf 11 Aug 2022 13 0.37 Mb
5 Electrolux ASL67050 Operation & user’s manual electrolux/asl67050-GT7.pdf 25 Nov 2023 28 3.56 Mb
6 Nikon AF-S Zoom-Nikkor ED 24-70mm/F2.8G (IF) Repair manual nikon/af-s-zoom-nikkor-ed-24-70mmf28g-if-K9X.pdf 23 Nov 2023 97

Similar Resources:

  • Dialogic

    DM/V1200-4E1-PCI

    (2 pages)
    Dialogic®DM/V1200-4E1-PCI Voice Board Quick Install Card Part Number 64-0071-02 Copyright © 2003-2007 Dialogic Corporation. All Rights Reserved. Before You Begin Protecting the Board from Damage Caution! All computer boards are sensitive to electrostatic discharge (“ESD”). Handle all static-sensitive boards and components at a static-safe work are …
  • D-Link

    DFE-530TX

    (5 pages)
    Contents of Package:Contents of Package:Contents of Package:Contents of Package: DFE-530TX+ Fast Ethernet Adapter Quick Install Guide CD-ROM, which includes driver software If any of the above items are missing, please contact your reseller. PrePrePrePre----installation Procedures:installation Procedures:installation Procedures:installation Procedures: …
  • Onkyo

    UWF-1

    (11 pages)
    Wireless USB adapterUWF-1Instruction ManualManuel d’instructionsManual de InstruccionesManuale di istruzioniBedienungsanleitungGebruiksaanwijzingBruksanvisning使用手冊使用手册取扱説明書EnglishFrançaisEspanõlItalianoDeutschNederlandsSvenska繁體中文简体中文日 本 語En Fr Es De It Nl Sv Ct Cs Ru Ja ArUWF-1.book Page 1 Tuesday, …
  • Abocom

    BTM100H

    (2 pages)
    Bluetooth™ module The BTM1000H is a miniature device for use in embedded systems that provides short-range wireless connectivity between Bluetooth-enabled devices for applications such as file transfer, ad-hoc networking, device synchronization, peripheral connectivity and a bridge to the Internet. The BTM1000H uses radio frequency, hence, voice and data …
  • HP

    ProCurve J8766A

    (124 pages)
    iRelease Notes:Version L.11.09 Softwarefor the ProCurve Series 4200vl SwitchesRelease L.11.09 supports these switches:■ ProCurve Switch 4204vl (J8770A), 4208vl (J8773A), 4202vl-72 (J8772A), 4202vl-48G (J8771A), 4204vl-48GS (J9064A), 4208vl-72GS (J9030A), 4208vl-96 (J8775A), and 4208vl-64G (J8774A).These release notes include information on the followin …
  • ADTRAN

    T200 H2TU-R

    (22 pages)
    61222026L7-5B Section 61222026L7-5, Issue 2 1Section 61222026L7-5BIssue 2, June 2001CLEI Code #T1L3W71A _ _T200 H2TU-R Circuit Pack2-Wire HDSL (HDSL2) Remote UnitInstallation and Maintenance1. GENERALThe ADTRAN 2-wire T200 HDSL2 transceiver unitfor the remote end (H2TU-R), P/N 1222026L7, is anetwork terminating unit used to deploy an HDSL2 T1circuit using 2 …

Comments, Questions and Opinions: