Manualios.com

United States Stove LOGWOOD 2421 Owner's Manual

United States Stove LOGWOOD 2421 Manual Online:

3.25, 518 votes
United States Stove LOGWOOD 2421 User Manual
United States Stove LOGWOOD 2421 User Guide
United States Stove LOGWOOD 2421 Online Manual

Text of United States Stove LOGWOOD 2421 User Guide:

  • United States Stove LOGWOOD 2421, CAUTION! Read All Instructions Care- fully Before Starting The In- stallation or Operating This Heater. DO NOT USE THIS HEATER IN A MOBILE HOME OR TRAILER SAVE THIS MANUAL FOR FUTURE REFERENCE THIS MANUAL WILL HELP YOU TO OBTAIN EFFICIENT, DEPENDABLE SERVICE FROM THE HEATER, AND ENABLE YOU TO ORDER REPAIR PARTS CORRECTLY. KEEP IN A SAFE PLACE FOR FUTURE REFERENCE. UNITED STATES STOVE COMPANY 227 Industrial Park Road P.O. Box 151 South Pittsburg, TN 37380 (423) 837-2100 C O M P A N Y U N I T E D S T A T E S S T O V E C S S U 851094D Owners ManualOwners

  • CONGRATULATIONS! You've purchased a heater from North America's oldest manufacturer of wood burning products. By heating with wood you're helping to CONSERVE ENERGY! Wood is our only Renewable Energy Resource. Please do your part to preserve our wood supply. Plant at least one tree each year. Future generations will thank you. Tools and Materials Needed TOOLS Pencil 6 Foot Folding

  • United States Stove LOGWOOD 2421, 3 Safety Rules SAFETY NOTICE: If this heater is not properly installed a house fire may result. For your safety, follow the installation directions. Contact local building or fire officials about restrictions and installation inspection requirements in your area. Read these rules and the instructions carefully. Check with local codes. The installation comply with their rulings. Observe closely the clearances to combustibles (page 4). Do not install this heater in a mobile home or trailer. Always connect this heater to a chimney and vent to the outside. Never vent to another room or inside a buildin

  • United States Stove LOGWOOD 2421, 4 Place the heater on solid masonry or solid concrete. When the heater is used on a combustible floor, use an Underwrit- ers Listed floor protector. The floor protector must comply with UL Standards.The base should extend at least 16" beyond the door of the heater and should extend under the flue pipe if it is elbowed towards a wall (Fig. 5). CAUTION! KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIALS AWAY FROM THE HEATER. MINIMUM CLEARANCE TO COMBUSTIBLE WALLS Installation FLOOR PROTECTOR FLOOR PROTECTOR FIG. 2 (60" MIN.) 18" FIG. 3 Uncrate and/or unpack the heater, removing all pack- ing material, being car

  • United States Stove LOGWOOD 2421, 5 Operation of the Heater BE SURE TO PUT A LAYER OF SAND OR FIREBRICK APPROXIMATELY 1 1/2" THICK IN THE BOTTOM OF THE STOVE BEFORE STARTING FIRE. Burn wood or wood products only. The wood should be air dried for at least six months prior to use for maximum effi- ciency. After the fire has been started and is burning satisfactorily, adjust the rate of burning by opening or closing the draft damper wheel on the feed door. Never build extremely large fires in this type of heater as damage to the heater or smoking may result. Provide air into the room for combustion. Do Not touch the heater after firing until it has cooled

  • CONNECTION OF CHIMNEY CONNECTOR TO A MASONRY CHIMNEY THROUGH A COMBUSTIBLE WALL Figure 8 shows how to connect the chimney connector of a heater to a masonry chimney through a combustible wall. There are five allowable ways that a chimney connector can be connected to a masonry chimney by passing through a combustible wall. NFPA Standard 211 allows the following wall pass-t

  • United States Stove LOGWOOD 2421, MINIMUM 12 IN. TO COMBUSTIBLES PART A, FIGURE 8 (FIGURE 5 CONTIUED ON NEXT PAGE) 1. Use a minimum 3-1/2" thick brick masonry wall framed into the combustible wall. A fireclay liner (ASTM C315 or equivalent) having a 5/8" minimum wall thickness must be used and it must be at least 12" away from any material that could catch fire. The inside diameter of the fireclay liner shall be sized for the proper snug fit of a 6" diameter chimney connector pipe. The fireclay liner shall run from the outer surface of the brick wall to, but not beyond, the

  • United States Stove LOGWOOD 2421, CONNECTION OF CHIMNEY CONNECTOR TO A MASONRY CHIMNEY WHEN CHINEY CONNECTOR DOES NOT PASS THROUGH A COMBUSTIBLE WALL PART E - (Figure 8) In addition to the methods shown by A, B, C, and D of Figure 8, a listed factory-built wall pass-through system may be purchased and installed according to the instructions packaged with it to provide a safe method of passing chimney connector through a combustible wall for a connection to a masonry chimney. If the chimney connector does not have to pass through a combustible wall to

  • United States Stove LOGWOOD 2421, CAUTION! NEVER USE GASOLINE, GASOLINE-TYPE LANTERN FUEL, KEROSENE, CHARCOAL LIGHTER FLUID, OR FLAMMABLE LIQUIDS TO START OR "FRESHEN UP" A FIRE IN THE HEATER. CAUTION! USE WOOD OR WOOD-LIKE MATERIALS ONLY. DO NOT USE COAL OR CHARCOAL. COAL OR CHARCOAL WILL DESTROY THE FIREBOX. DO NOT USE DRIED LUMBER OR TREATED WOOD. 9 WARNING! NEVER STORE FLAMMABLE LIQUIDS, ESPECIALLY GASOLINE. IN THE VICINITY OF THE HEATER. CAUTION! OVERFIRING THE APPLIANCE MAY CAUSE A HOUSE FIRE. IF A UNIT OR CHIMNEY CONNECTOR GLOWS, YOU ARE OVERFIRING. WARNING! NEVER OPERATE THIS HEATER WITH THE FUEL DOOR OPEN. NOTE: DO NOT ELEVATE FIRE OR USE WI

  • United States Stove LOGWOOD 2421, 10 Model 2421 Repair Parts 20 18 19 21 22 15 11 12 16 14 10 1 3 2 6 7 13 17 9 8 5 4 KEY 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 * PART NO. 40319 40319 40320 40321 40322 40323 40324 40325 40326 40327 40329 40330 40331 40332 D6 83427 40334 89971 89972 89973 89974 89975 851094 DESCRIPTION REAR LEG FRONT LEG MAIN BOTTOM MAIN SIDE MAIN BACK HEARTH PLATE SLIDING DRAFT PLATE DOOR FRAME DOOR MAIN TOP LID LID SUPPORT LID LIFTER FLUE COLLAR SOLID FLUE DAMPER DOOR PINS DRAFT CONTROL KNOB HANDLE LATCH NUTS HANDLE EXTENSION HANDLE BRACKET OWNERS MANUAL QNTY. 2 2 1 2 1 1

  • United States Stove LOGWOOD 2421, HOW TO ORDER REPAIR PARTS THIS MANUAL WILL HELP YOU OBTAIN EFFICIENT, DEPENDABLE SERVICE FROM THE HEATER, AND ENABLE YOU TO ORDER REPAIR PARTS CORRECTLY. KEEP IN A SAFE PLACE FOR FUTURE REFERENCE. WHEN WRITING, ALWAYS GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE ATTACHED TO THE BACK OF THE HEATER. WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION AS SHOWN IN THIS LIST: 1. The PART NUMBER 2. The PART DESCRIPTION 3. The MODEL NUMBER: 2421 4. The SERIAL NUMBER: UNITED STATES STOVE COMPANY 227 Industrial Park Road P.O. Box 151 South Pittsburg, TN 37380 (423) 837-2100 www.USSTOVE.com

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Samsung CS20V10MJOXAWE Service manual samsung/cs20v10mjoxawe-549.pdf 15 Jul 2023 61
2 Chevrolet 2005 Silverado 1500 Pickup Owner's manual chevrolet/2005-silverado-1500-pickup-1DZ.pdf 29 May 2023 582 3.65 Mb
3 Behringer B-CONTROL DEEJAY BCD2000 Operation & user’s manual behringer/b-control-deejay-bcd2000-188.pdf 07 Nov 2023 17 1.19 Mb
4 Triarch Indoor Lighting 60142 Assembling instructions triarch/indoor-lighting-60142-155.pdf 23 Nov 2022 1 0.16 Mb
5 Tennant 6080 Operator's manual tennant/6080-152.pdf 26 Jul 2022 54
6 TerraTec Sync Xtension EWS ClockWork Quick reference terratec/sync-xtension-ews-clockwork-3DK.pdf 08 Sep 2022 14 0.85 Mb

Similar Resources:

  • Midea

    MTB1T-96CWN1

    (111 pages)
    Midea R410A T3 50Hz Split Type Top-discharge Series Technical Service Manual Applicable Model: Indoor unit Outdoor unit MTB1T-96C(H)WN1 MOVTA-96C(H)N1-R MHB1T-96C(H)WN1 MFA3T-96C(H)RN1 Midea reserves the right to discontinue, or change specification or designs at any time without notices and without incurring obligations. …
  • Swegon

    PARASOL Zenith 1200

    (36 pages)
    Variant Supply air PerformanceSize Air connectionPa* l/s m3/h Total cooling capacity (W)**Sound level (dB(A))1200 Ø160 50 20 72 763 <201200 Ø160 50 40 144 112 3 221200 Ø160 50 60 216 1329 261200 Ø160 75 20 72 835 211200 Ø160 75 40 144 1243 251200 Ø160 75 60 216 1482 281800 Ø160 50 20 72 884 <201800 Ø160 50 50 180 1463 241800 Ø160 50 80 288 17 …
  • Dirna

    bycool Dinamic 1.1

    (84 pages)
    Instrucciones de MontajeMounting InstructionsInstructions de MontageMontageanweisungenIstruzioni di Montaggio220.AA1.1008ESSpanishEnglishFrenchGermanItalianENFRGEITDINAMIC 1.112 Vdirna, s.a.Acondicionadores de aire para vehículos …
  • Hitachi

    RAK-60NHA1

    (24 pages)
    – 1 –ENGLISHSPLIT TYPE AIR CONDITIONERINDOOR UNITMODELRAK-60NHA1RAK-70NHA1INDOOR UNITRAK-60NHA1RAK-70NHA1Instruction manual Page 1~24To obtain the best performance and ensure years of trouble free use, please read this instruction manual completely.(EN1) RAK-60-70NHA1 1(EN1) RAK-60-70NHA1 1 3/27/14 6:24 PM3/27/14 6:24 PM …
  • Mitsubishi Electric

    MSZ-AS90VGD

    (8 pages)
    JG79J842H01Required Tools for InstallationPhillips screwdriverLevelScale8WLOLW\NQLIHRUVFLVVRUV75 mm hole saw7RUTXHZUHQFKWrench (or spanner)4 mm hexagonal wrenchFlare tool for R32, R410AGauge manifold for R32, R410AVacuum pump for R32, R410ACharge hose for R32, R410APipe cutter with reamerSPLIT-TYPE AIR CONDITIONERSINSTALLATION MANUALENGLISHModel …
  • Fujitsu

    ASYG24LFCC

    (20 pages)
    SPLIT TYPEROOM AIR CONDITIONERWALL MOUNTED TYPEIndoor unit Outdoor unitASYG24LFCC AOYG24LFCCCONTENTSSPECIFICATIONS. . . . . . . . . . . . . . . . . . .1DIMENSIONS . . . . . . . . . . . . . . . . . . . . . .2REFRIGERANT SYSTEM DIAGRAM. . . .3CIRCUIT DIAGRAM . . . . . . . . . . . . . . . . .4ERROR DETECTION . . . . . . . . . . . . . . .5INDOOR PCB CIRCUIT DIAG …

Comments, Questions and Opinions: