DIS DCS-6000 Technical Specifications
|
DIS DCS-6000, Danish Interpretation Systems Technical Specifications Printed in Denmark 21 4.3.5 Messages in Voting_CONTROL_GRP The following control messages controls voting sessions and attendance check sessions in the CU. Again, the message format descriptions have the same meaning as in section 3.4.3. COMMAND_ITEM_VOTING_CONTROL_TYPE_OF_VOTING Command item value: 1 Message format: <START> ‘j’ <ID> <0> <MSB addr> <LSB Addr> <52> <1> <Type of Voting> <0> <CRC> <STOP> The Type of Voting parameter defines, which type of voting session is to take place. Type of Voting is defined prior to execution o
DIS DCS-6000, Danish Interpretation Systems Technical Specifications Printed in Denmark 15 MICROPHONE_CONTROL_CLEAR_REQUEST_LIST Command item value: 8 Message format: <START> ‘j’ <ID> <0> <MSB addr> <LSB Addr> <18> <8> <0> <0> <CRC> <STOP> Clears the request list. MICROPHONE_CONTROL_SET_MAXSPEAKERS Command item value: 12 Message format: <START> ‘j’ <ID> <0> <MSB addr> <LSB Addr> <18> <12> <Max Speakers> <0> <CRC> <STOP> Set the m
Danish Interpretation Systems Technical Specifications Printed in Denmark 23 Message format: <START> ‘j’ <ID> <0> <MSB addr> <LSB Addr> <52> <14> <0> <0> <CRC> <STOP> Once an attendance check has been completed successfully, the external control unit can request the attendance check result. The attendance chec
DIS DCS-6000, Danish Interpretation Systems Technical Specifications Printed in Denmark 35 AUDIO_STATUS_MU_LINEIN_TO_LINEOUT Command item value: 9 Message format: <START> 'c' <ID> <MSB addr> <LSB addr> <29> <2> <9> <Gain Level> <CRC> <STOP> This message signifies that the gain setting of amplifier 3 has been changed to Gain Level dB. A setting of –41dB means the amplifier is switched off. AUDIO_STATUS_MU_LINE_IN_LEVEL Command item value: 14 Message format: <START> 'c' <ID> <MSB addr> <LSB addr> <29> <2> <14> <Gain Level> <CRC> <STOP> Th
DIS DCS-6000, Danish Interpretation Systems Technical Specifications Printed in Denmark 41 The votes of a delegate is only valid, if the address is not 0 and the Vote is not 0: Example: Imagine, that the CU has received a Yes-vote from address 3 and a No-vote from address 20. The CU ‘packs’ the votes of both units into the same message. <START> 'c' <ID> <15> <173> <69> <8> <0> <19> <1> <52> <0> <0> <0> <18> <CRC> <STOP> For Address 1 w
Danish Interpretation Systems Technical Specifications Printed in Denmark 27 Messages in MAIN_GRP The following subsections describe each of the messages in the group. The message format descriptions have the same meaning as in section 3.4.4. MAIN_FOUND_UNIT Command item value: 26 Message format: <START> 'c' <ID> <MS
DIS DCS-6000, Danish Interpretation Systems Technical Specifications Printed in Denmark 42 EXTERNAL_HEART_BEAT_REQUEST 3 Request to external control units to confirm RS232 communication MICROPHONE_STATUS_GRP (=23): Command Item value Comment MICROPHONE_STATUS_DELEGATE_OFF_ACTIVE 1 Delegate Off is active MICROPHONE_STATUS_DELEGATE_OFF_INACTIVE 2 Delegate Off is no longer active MICROPHONE_STATUS_DELEGATE_MUTE_ACTIVE 3 All speaking delegates are muted MICROPHONE_STATUS_DELEGATE_MUTE_INACTIVE 4 Speaking delegates are no longer muted MICROPHONE_STATUS_MICROPHONE_IN_REQUEST 7 A delegate is in request MICROPHONE_STATUS_MICROPHONE_IN_SPEAK 8 A
DIS DCS-6000, Danish Interpretation Systems Technical Specifications Printed in Denmark 43 delegates to LineOut AUDIO_STATUS_MU_LINEIN_TO_SPEAKER 8 Audio level from LineIn to delegate loudspeakers AUDIO_STATUS_MU_LINEIN_TO_LINEOUT 9 Audio level from LineIn to LineOut AUDIO_STATUS_MU_LINE_IN_LEVEL 14 LineIn level. AUDIO_STATUS_MU_STATUS_START 20 Start of Audio status stream AUDIO_STATUS_MU_STATUS_STOP 21 End of Audio status stream VOTING_STATUS_GRP (=53): Command Item value Comment VOTING_STATUS_TYPE_OF_VOTING 1 3-Button voting or 5-Button voting
DIS DCS-6000, Danish Interpretation Systems Technical Specifications Printed in Denmark 24 followed by the message VOTING_STATUS_VOTING_CLOSED. Notice, the order of these messages is opposite to the attendance check. VOTING_CONTROL_REQUEST_VOTING_DETAILS Command item value: 21 Message format: <START> ‘j’ <ID> <0> <MSB addr> <LSB Addr> <52> <21> <0> <0> <CRC> <STOP> Also, the result of a voting session remains in the CU until start of the next voting session or reset of the CU. With this command the CU is requested to deliver the details of the latest completed
DIS DCS-6000, Danish Interpretation Systems Technical Specifications Printed in Denmark 34 AUDIO_STATUS_MU_SPEAKER_OFF Command item value: 4 Message format: <START> 'c' <ID> <MSB addr> <LSB addr> <29> <1> <4> <CRC> <STOP> The CU sends this message when the speakers on the delegate microphones are switched off. AUDIO_STATUS_MU_LINEOUT_VOLUME Command item value: 5 Message format: <START> 'c' <ID> <MSB addr> <LSB addr> <
DIS DCS-6000, Danish Interpretation Systems Technical Specifications Printed in Denmark 5 2 Introduction and document overview The DCS 6000 system offers the possibility of controlling the microphones from a PC, AMX or other external control unit via a serial connection. This text documents how this feature is used; how external control of the DCS 6000 system is executed. The protocol used on the cable between the central unit (CU) of the DCS 6000 system and the external control unit is described in general in section 3. Parts of this protocol encapsulate the protocol used on the DCS 6000 bus and thus enable the CU and the external control unit to communicate as if
DIS DCS-6000, Danish Interpretation Systems Technical Specifications Printed in Denmark 32 The CU sends this message to tell that a complete update on the status of the microphone control application will be sent. MICROPHONE_STATUS_UPDATE_STOP Command item value: 20 Message format: <START> 'c' <ID> <MSB addr> <LSB addr> <23> <1> <20> <CRC> <STOP> The CU sends this message to tell that it has just finished sending a complete update on the status of the microphone control application. MICROPHONE_STATUS_MICROPHONE_ACTIVITY_STATUS Command item value: 22 Message format:
DIS DCS-6000, Danish Interpretation Systems Technical Specifications Printed in Denmark 12 4 DCS 6000 Messages The RS232 binary protocol is used to transfer DCS 6000 system commands between the CU and the external control unit. General definitions for the communication are described in sections 3.4.3 and 3.4.4. This section describes the details for the commands that can be sent via the RS232 protocol. 4.1 Addresses in the DCS 6000 system Units, connected to the CU and provided with ability to initiate communica
DIS DCS-6000, Danish Interpretation Systems Technical Specifications Copyright © 2006 DIS DCS6000 RS232 MANUAL REV I.DOC 12-09-2006 No part of this publication may be reproduced or utilized in any form or by any means without permission in writing from the publisher 1 List of Contents 1 List of Contents ............................................................................................................................ 2 1.1 Revision history................................................................................................................... 4 2 Introduction and document overview......................................................
Danish Interpretation Systems Technical Specifications Printed in Denmark 25 MICROPHONE_CONTROL_MICROPHONE_ON 14 Turn on a delegate microphone. MICROPHONE_CONTROL_MICROPHONE_OFF 15 Turn off a delegate microphone MICROPHONE_CONTROL_REQUEST_ON 16 Set a delegate in the request list MICROPHONE_CONTROL_REQUEST_OFF 17 Remove a delegate from the request list MICROPHONE_CONTR
DIS DCS-6000, Danish Interpretation Systems Technical Specifications Printed in Denmark 13 • The MICROPHONE_CONTROL_GRP with messages regarding switching microphone on/off, controlling the request queue etc. The value corresponding to MICROPHONE_CONTROL_GRP is 18. • The VOTING_CONTROL_GRP with messages to start and stop attendance check and voting sessions, and to request voting results. The value corresponding to VOTING_CONTROL_GRP is 52. The following sections describe the messages from each message group. 4.3.1 Messages in EXTERNAL_CONTROL_GRP The following subsections describe each of the messages in the group. The message format descriptions have the s
DIS DCS-6000, Danish Interpretation Systems Technical Specifications Printed in Denmark 37 <START> 'c' <ID> <MSB addr> <LSB addr> <53> <1> <13> <CRC> <STOP> This message informs that an attendance is cancelled by the CU. This only happens in case of communication problems. After cancellation of an attendance check, the CU does not store any attendance check result. VOTING_STATUS_INTERIM_ATTENDANCE_RESULT Command item value: 14 Message format: <START> 'c' <ID> <MSB addr> <LSB addr> <53
DIS DCS-6000, Danish Interpretation Systems Technical Specifications Printed in Denmark 50 6 Additional detailed example 6.1 Example - Registration with the CU The first example shows how registration with the CU is done from AMX. The AMX equipment is connected to the CU via the RS232 connection. The CU has already been powered up. Three steps must be passed: - Step (1) - The CU must be put in Microphone Control Mode - Step (2) – A registration request must be transmitted from AMX - Step (3) – The registration reply is received in AMX 6.1.1 Step (1) – Entering Microphone Control Mode Entering t
DIS DCS-6000, Danish Interpretation Systems Technical Specifications Printed in Denmark 44 5 Controlling Microphones The purpose of this section is to give a short summary of how the methods described in the rest of the manual can be used to control the system. 5.1 CRC Calculation 5.1.1 CU Reset message When the CU is powered up, the very first control message to send to the external control unit is a ‘CU reset’ message. It has the format: <START> ‘r’ <ID> <CRC> <STOP> The CRC-checksum is calculated from the bytes ‘r’ <ID> Wit
DIS DCS-6000, Danish Interpretation Systems Technical Specifications Printed in Denmark 6 3-Button voting sessions provide the delegates with the option to make a selection among three alternatives: (typically Yes, Abstain and No), whereas 5-button voting sessions offer 5 alternatives (typically ++, +, 0, - and --). During an Open voting session, the votes are captured by the voting units, and the voting units show to the delegate, which button was pressed. If a voting session is defined as Secret, the voting units still register, when the delegates vo
DIS DCS-6000, Danish Interpretation Systems Technical Specifications Printed in Denmark 8 3 Serial Protocol All communication between the CU and the external control unit is done through a serial connection either via RS232 or RS422. The format of the serial data is 8 data bits, 1 stop bit and no parity. Possible bit rates are 2400, 4800, 9600, 19200, 38400, 57600 and 115200 bits/s. The default is 115200 bits/s. Hardware flow control is used on the serial port. The CU provides a possibility to save the settings in a configuration. Whenever the
DIS DCS-6000, Danish Interpretation Systems Technical Specifications Printed in Denmark 26 VOTING_CONTROL_MU (=52): Command Item value Comment VOTING_CONTROL_TYPE_OF_VOTING 1 3-Button or 5-Button voting. VOTING_CONTROL_SECET_VOTING 3 Open or Secret voting. VOTING_CONTROL_START_ATTENDANCE_CHECK 11 Start an attendance check VOTING_CONTROL_STOP_ATTENDANCE_CHECK 12 Stop an attendance check VOTING_CONTROL_REQUEST_ATTENDANCE_RESULT 14 Request the CU to deliver the results of the most rece
Danish Interpretation Systems Technical Specifications Printed in Denmark 36 Type of Voting Value Description 3-Button Voting 3 Three voting alternatives will be available – typically Yes, Abstain and No. 5-Button Voting 5 Five voting alternatives will be available – typically ++, +, 0, - and --. VOTING_STATUS_SECRET_VOTING Command item value: 3 Messa
DIS DCS-6000, Danish Interpretation Systems Technical Specifications Printed in Denmark 31 MICROPHONE_STATUS_MAX_SPEAKERS Command item value: 15 Message format: <START> 'c' <ID> <MSB addr> <LSB addr> <23> <2> <15> <Max Speakers Value> <CRC> <STOP> Sent to signify that the maximum number of simultaneous active delegate microphones has been set to Max Speakers Value. The message is sent both when the value has been changed and as part of the system status. MICROPHONE_STATU
DIS DCS-6000, DCS 6000 Technical specifications Danish Interpretation Systems DIS Digital Conference System DCS 6000 External Microphone Control RS232 protocol Please refer to ‘Revision History’ at page 4 for compatibility to releases prior to Release 5.1.
DIS DCS-6000, Danish Interpretation Systems Technical Specifications Printed in Denmark 10 3.4 Message types The following sections describe the types of messages that are sent between the CU and the external control unit. For each message type the format of the messages of this type is shown, this description excludes the start/stop delimiters and the CRC. The field <ID> in the following descriptions refers to the identifier byte introduced in section 3.1. 3.4.1 CU reset (CU external) When the CU powers up, it transmits a binary message on the serial interface, in order to inform external control units, that the DCS
DIS DCS-6000, Danish Interpretation Systems Technical Specifications Printed in Denmark 17 4.3.3 MICROPHONE_PRIORITY This message is used to setup the speak priority for microphone units (chairman units and delegate units). Message format: <START> 'j' <ID> <0> <MSB addr> <LSB Addr> <25> <Microphone Addr MSB> <Microphone Addr LSB> <Speak Priority> <CRC> <STOP> The message defines the microphone speak priority for the microphone unit, which has the address 256* Microphone Addr MSB + Microphone Addr LSB to the value of
DIS DCS-6000, Danish Interpretation Systems Technical Specifications Printed in Denmark 22 <START> ‘j’ <ID> <0> <MSB addr> <LSB Addr> <52> <11> <0> <0> <CRC> <STOP> An attendance check (or presence check) among delegates is conducted in order to determine, how many are actually participating the meeting – how many votes can be cast from the present delegates. This command is sent to the CU to start an attendance check. If the CU accepts the command to start an attendance check, it issues the VOTING_STATUS_ATTENDANCE_CHECK_STARTED message of the VOTING_STATUS_G
Danish Interpretation Systems Technical Specifications Printed in Denmark 38 Message format: <START> 'c' <ID> <MSB addr> <LSB addr> <53> <1> <18> <CRC> <STOP> This message informs that a voting session is closed in the CU. Immediately before this message, the CU has distributed the final
Altigen AltiConsole Microphone Manual
AltiConsole |
Fujitsu fi-4340C Microphone Cleaning and maintenance
fi-4340C |
DIS DDS 5900 Microphone Operation & user’s manual
DDS 5900 |
Sennheiser SR 2000 IEM Microphone Instruction manual
SR 2000 IEM |
DIS DCS-6000 Microphone Installation manual
DCS-6000 |
DIS CDS-4000 Microphone Operation & user’s manual
CDS-4000 |
Vinotemp WINE-MATE WM-2500SSV Microphone Installation, operation & care manual
WINE-MATE WM-2500SSV |
DIS Central Unit CU 6010 Microphone Operation & user’s manual
Central Unit CU 6010 |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Euroterm | 2604 | Installation and wiring instructions | euroterm/2604-43E.pdf | 06 Sep 2023 | 2 | |
2 | Dell | dxcwrk1 - XPS - One | Owner's manual | dell/dxcwrk1-xps-one-7G8.pdf | 26 Jun 2023 | 166 | 6.32 Mb |
3 | NEC | NP1000 | Network setup manual | nec/np1000-YF1.pdf | 06 Mar 2024 | 40 | |
4 | Ronda | 505.24D | Operation & user’s manual | ronda/50524d-8GZ.pdf | 27 Feb 2024 | 2 | |
5 | Fujitsu | D2660-C BTX | Datasheet | fujitsu/d2660-c-btx-5N8.pdf | 29 Mar 2023 | 2 | 0.35 Mb |
6 | Oster | OGG61403 | Operation & user’s manual | oster/ogg61403-681.pdf | 26 Jan 2024 | 17 |
KAM
KAM KWM6 & KWM11VHF WIRELESS MICROPHONE KITSINSTRUCTION MANUALKAM KWM6 & KWM11VHF WIRELESS MICROPHONE KITSMICROPHONE TRANSMITTER(s)q POWER ON / OFF SWITCHw POWER ON INDICATOR LIGHTe LOW BATTERY INDICATOR LIGHT - when lit you haveapproximately one hour left of useful operation. Ideallychange the battery when lit.r MUTE / ON SWITCH - mutes the output o …
KWM6(1 pages) |
Avsl
U-MIC Item ref: 171.806UK, 171.807UK USB Powered UHF Wireless Microphone User Manual Version 1.0 Caution: Please read this manual carefully before operating Damage caused by misuse is not covered by the warranty
…
QTX U-MIC 171.806UK(4 pages) |
Sennheiser
Miniature CameraMicrophone Rugged metal housing Maximum side noise rejection, optimized for video recordings Switchable sensitivity for long and short distances Switchable wind noise filter More than 300 hrs operating time ( from a single AAA battery) Battery condition LED Integral shock-mount for rejection of handling …
MKE 400(2 pages) |
Conrad
Version 07/02Konferenz-Mikrofon „Business“ °Best.-Nr. 30 09 07Bestimmungsgemäße VerwendungDas Mikrofon dient zur Umwandlung von akustischen Signalen (Schallwellen) inelektrische Signale.Das niederpegelige Audioausgangssignal darf nur an geeignete Mikrofoneingängevon Audiogeräten angeschlossen werden.Das Mikrofon darf nur über eine Batterie (Typ sie …
30 09 07(2 pages) |
ETS
SM5-EQ-PSSE Microphone kit Instructions The SM5-EQ-PSSE is a single channel audio equalizer and microphone interface designed for use in acoustically difficult environments such as interrogation rooms. The SM1-PSSE High performance, tamper resistant, very low noise microphone with an automatic gain control circuit is included with the kit. Note- …
SM5-EQ-PSSE(2 pages) |
Audio Technica
Architects and Engineers SpecificationsThe microphone shall be a multiple-pattern capacitor with afrequency response of 20 Hz to 20,000 Hz. Polar pattern shall beswitchable to cardioid, omnidirectional or figure-of-eight. It shalloperate from an external 48V DC (±4V) phantom power source. Thedual-diaphragm element shall be internally shock mounted.Nominal o …
AT4050(2 pages) |
Samsung Cell Phone SGH-T849#68876U: SGH-T849 Cell Phone Manual del usuario SGH-T849, 158 |
Samsung Projection TV HL-R4656WSamsung HL-R4656W User Manual (Doc Type: Projection TV Owner's instructions manual) HL-R4656W, 96 |
Symmons Plumbing Product Origins 9600-PLRUser Guide: Symmons Origins 9600-PLR (L3L4M2, Upd.Sunday 07-01-2024) Origins 9600-PLR, 15 |
Telex Intercom System BP-2000BP-2000 Operating instructions manual - Q1ZIMR BP-2000, 20 |
Novus Security Camera NVIP-7000 seriesNovus NVIP-7000 series Guide (Doc Type: Security Camera Operation & user’s manual) NVIP-7000 series, 108 |
Mase Portable Generator FM 3000 SPortable Generator PDF Use and maintenance manual FM 3000 S, 21 |
Frigidaire Cooktop FFGS3025LBCooktop PDF Product specifications FFGS3025LB, 2 |
Huawei Other CR52-SFUAHuawei CR52-SFUA Other Specifications CR52-SFUA, 1 |
Makita Grinder 906Makita 906 User Manual (Doc Type: Grinder Instruction manual) 906, 40 |
Altronix Power Supply AL802ULADAPower Supply Installation manual (Altronix AL802ULADA) AL802ULADA, 12 |
EVGA Motherboard 141-GT-E770-A1Guide: EVGA 141-GT-E770-A1 (18K7G8, Upd.Thu 12.2023) 141-GT-E770-A1, 2 |
Lexmark Printer C720Lexmark Printer Quick reference (File: lexmark-15w0003-c-720-color-laser-printer-quick-reference-2, 08/09/2023) C720, 2 |