Manualios.com

DIS CCS 7800 Operation & User’s Manual

DIS CCS 7800 Manual Online:

3.5, 2592 votes
DIS CCS 7800 User Manual
DIS CCS 7800 User Guide
DIS CCS 7800 Online Manual

Text of DIS CCS 7800 User Guide:

  • DIS CCS 7800, Danish Interpretation Systems CP 7851 User Manual Manual 02 19 78510 10 12. Camera Presets The screen is used to save the preset for each microphone. How to save presets: 1. Turn on one microphone (the seat number will be shown in the “Seat Number” field for that microphone). 2. Select the camera to use. 3. Move the camera to a desired position by camera control 4. Press “Save”. The Preset for the seat is now saved. A disk icon is now showed on the camera no. where the seat preset has been saved 5. Repeat step 2-5 for more camera presets for the sam

  • DIS CCS 7800, Danish Interpretation Systems CP 7851 User Manual Manual 02 19 78510 40 Changing of Wireless Router Channel # Description Comment or picture 42. Connect a PC to the Wireless Router using one of the four LAN ports and turn on power to the Linksys. Can also be connected via the wireless connection by a PC or the iPad. 43. Open a browser and type the following in the address line: http://192.168.10.1 When asked for username and password type: Login: (leave empty) Password: admin This will open a login screen on the Router 44. Select “Ba

  • DIS CCS 7800, Danish Interpretation Systems CP 7851 User Manual Manual 02 19 78510 4 Introduction CP 7851 Package CP 7851 Camera Control Package consists of the following items: • iPad touch with preloaded SW 7810 Microphone and Camera Control Software • Camera System Control Unit with preloaded SW 7820 Camera Control Software • Wireless Router The CP 7851 Camera Control Package is part of the CCS 7800 Camera Control System. Further products might be added to the Camera Control System Product Description The Camera Control Package con

  • DIS CCS 7800, Danish Interpretation Systems User Manual Copyright © 2012 DIS CP 7851 USER MANUAL - REV E.DOC 29-10-2012 No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the publisher. List of Contents List of Contents ......................................................... 3 Introduction .............................................................. 4 CP 7851 Package .................................................. 4 Product Description ............................................ 4 Part List ................................................................... 5 Important ......................................

  • DIS CCS 7800, Danish Interpretation Systems CP 7851 User Manual Manual 02 19 78510 24 Setting up the system for TCP/IP mode # Description Comment or picture 30 Connect the system as shown in above schematic ‘Single Camera, TCP/IP connection’. The Visca cable from the Camera shall be connected to PORT 2 on the SCU. 31 Turn on the CU 5905 in the DDS 5900 system 32 Use the 5-button keypad on CU5905 to navigate to the LAN setup. Change the following settings to: See ‘DDS 5900 User Manual’ for more information on how to change setting on the CU 5905. Aquire IP addr. : Static IP Address: 192.168.10.110 Subnet mask: 255.255.255.0

  • DIS CCS 7800, Danish Interpretation Systems CP 7851 User Manual Manual 02 19 78510 27 40. Camera Presets The screen is used to save the preset for each microphone. How to save presets: 9. Turn on one microphone (the seat number will be shown in the “Seat Number” field for that microphone). 10. Select the camera to use. 11. Move the camera to a desired position by camera control 12. Press “Save”. The Preset for the seat is now saved. A disk icon is now showed on the camera no. where the seat preset has been saved 13. Repeat step 2-5 for more cam

  • DIS CCS 7800, Danish Interpretation Systems CP 7851 User Manual Manual 02 19 78510 17 24. Camera Operation The “Camera Operation” is used for operating the cameras manual if desired. Select which camera to operate using the camera buttons in lower left corner (up to four cameras). The camera can now be operated using the arrow buttons for UP/Down and Left/Right movement. The speed of the movement as well as Zoom In/Out can be adjusted. NOTE: No camera position can be stored from this menu.

  • Danish Interpretation Systems CP 7851 User Manual Manual 02 19 78510 28 41. Setup System No. of Cameras Select the number of cameras connected (1 to 4) Max. NOM to Overview Select the Number Of Microphones (1 to 8) which can be opened before the system switches to the overview picture Overview delay (sec) Adjusting the delay before switching to the ov

  • DIS CCS 7800, Danish Interpretation Systems CP 7851 User Manual Manual 02 19 78510 7 Setting up the system for ECA Mode # Description Comment or picture 1. Connect the system as shown in above schematic ‘Single Camera, ECA connection’, using the RS 232 cables supplied. IMPORTANT: The RS 232 connector on the PC running the ECA shall be connected to PORT 1 on the SCU using the supplied RS 232 cable plus the RS232 adapter. NOTE that the adaptor has to be mounted in the PC end of the RS-232 cable. The Visca

  • Danish Interpretation Systems CP 7851 User Manual Manual 02 19 78510 13 Use with CU 60xx, direct CU connection Schematic Single Camera, CU 6005/11 Connection Single Camera, CU 6005/11 Connection

  • DIS CCS 7800, Danish Interpretation Systems CP 7851 User Manual Manual 02 19 78510 22 29. Exchange a conference unit Be sure that either Automatic or FIFO has been selected as Operation Mode in the Conference menu before Seat Setup is selected. How to exchange a microphone unit: 1. Select Seat Setup in the System Setup menu. 2. Activate the new microphone unit. The unit serial no will be shown in Mic On (S/N). 3. Then select Start Setup. When asked Confirm Clear Seat Data then select C

  • DIS CCS 7800, Danish Interpretation Systems CP 7851 User Manual Manual 02 19 78510 29 After the system is setup After having set up all camera presets and saved the Layout (s) the system is ready to use. The iPad (IPC) and the Wireless Router (WR) can be switched Off as they are only needed for setting up the system. However the iPad can be used to control the DDS 5900 browser interface, see more in the DDS 5900 User Manual. If for any reason controlling of the camera(s) is needed during the meeting, the IPC a

  • DIS CCS 7800, Danish Interpretation Systems CP 7851 User Manual Manual 02 19 78510 12 After the system is setup After having set up all camera presets and saved the Layout (s) the system is ready to use. The iPad (IPC) and the Wireless Router (WR) can be switched Off as they are only needed for setting up the system. If for any reason controlling of the camera(s) is needed during the meeting, the IPC and the WR shall not be switched Off.

  • DIS CCS 7800, Danish Interpretation Systems CP 7851 User Manual Manual 02 19 78510 20 27. Seat Setup This page is used to assign a seat number to each microphone unit. Be sure that either Automatic or FIFO has been selected as Operation Mode in the Conference menu before seat setup is started. The ‘Status Assigned’ info will show the number of connected microphone and how many of those which has been assigned a seat number: assigned/total number of microphones How to assign seats: 1. Select “Start Setup” to start the assignment 2. Select “Clear” at “Confirm Clear Seat Data?” and old seat

  • DIS CCS 7800, Danish Interpretation Systems CP 7851 User Manual Manual 02 19 78510 15 Using the iPad Control in Direct CU Mode 17. Turn on power to the iPad and select Wi-Fi in Settings 18. Choose the: DIS CP 7851-xxxA Network. The ‘xxx’ is the system serial no. Password for the network: 123456789 DO NOT select the DIS CP 7851-xxxB network. The Linksys has to be powered up and connected to the Camera Control Unit with LAN cable 19. Start “iRidium HD” on the iPad. Touch the screen to Start. Select “Direct CU Mode” in the “System Setup" menu. Wh

  • DIS CCS 7800, Danish Interpretation Systems CP 7851 User Manual Manual 02 19 78510 14 Setting up the system for Direct CU Mode # Description Comment or picture 14 Connect the system as shown in above schematic ‘Single Camera, CU 6005/11 connection’, using the cables supplied. IMPORTANT: The RS 232 connector on the CU 6005/11 shall be connected to PORT1 on the SCU using the supplied RS 232 cable. The Visca cable from the Camera shall be connected to PORT 2 on the SCU. 15 On the CU 60xx do the following setting: Set Baud Rate: 19200 for RS 232 setting by using the co

  • DIS CCS 7800, Danish Interpretation Systems CP 7851 User Manual Manual 02 19 78510 39 In the Basic Setup under Setup select TCP/IP. Under IPv4 select “Use the following IP Address” and then type in: • IP address: 192.168.10.91 • Subnet mask: 255.255.255.0 • Default router: 192.168.10.1 Press save and ok twice. Wait approx. 30 sec and then the IP Address has been changed on the AXIS M7001 and it is ready to be used with camera system. If the IP address 192.168.10.91 is typed in a browser address line then you will have the video streaming in the browser window. Use username “root” and password “1234” without quotes.

  • DIS CCS 7800, Danish Interpretation Systems User Manual Copyright © 2012 DIS CP 7851 USER MANUAL - REV E.DOC 29-10-2012 No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the publisher.

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Raveon RV-M8S Technical manual raveon/rv-m8s-A5S.pdf 02 Dec 2022 39
2 Hussmann B4X-E Technical data sheet hussmann/b4x-e-VXC.pdf 01 Jan 2023 11
3 marklin 37925 Operation & user’s manual marklin/37925-15Y.pdf 25 May 2023 40
4 Sanus Systems MF203 Manual  sanus-systems/mf203-52S.pdf 24 Oct 2023 20 3.76 Mb
5 Victor 1460-4 Quick start manual victor/1460-4-UU6.pdf 20 Dec 2023 1 0.05 Mb
6 Dell E2213 Messaging brief dell/e2213-VLL.pdf 31 Jan 2023 12 0.33 Mb

Similar Resources:

  • Bosch

    B925F

    (2 pages)
    1 | OverviewCommand Function[CMD] 0 Bypass[CMD] 0 0 Unbypass[CMD] 1 All on (with delay)[CMD] 1 1 All On, Instant[CMD] 2 Part On, Instant[CMD] 3 Part On (with delay)[CMD] 4 Silence Trouble Sounders[CMD] 4 0 See Alarms[CMD] 4 1 Test Report[CMD] 4 2 Status Report[CMD] 4 3 RPS Answer[CMD] 4 4 Intrusion Walk Test[CMD] 4 5 Date and Time[CMD] 4 6 Door Control Menu[ …
  • Acroprint

    TimeQ+ Biometric

    (24 pages)
    BIOMETRIC FINGERPRINT TECHNOLOGYInstallation GuideNOTE: This equipment has been tested and found to comply with the limits for a Class B digitaldevice, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonableprotection against harmful interference in a residential installation. This equipment generates,uses and can radiate radio …
  • Lenser

    LS-GSM-006

    (26 pages)
    -1-GSMGSMGSMGSM Home/BusinessHome/BusinessHome/BusinessHome/Business AlarmAlarmAlarmAlarm SystemSystemSystemSystemUserUserUserUser ManualManualManualManual(LS-GSM-006)(LS-GSM-006)(LS-GSM-006)(LS-GSM-006)ProfileProfileProfileProfileFor a better understanding of this product, please read this user manual thoroughly before using it. …
  • Code 3

    XCEL Series

    (12 pages)
    Page 1 of 12Installation and Operation InstructionsIMPORTANT! Read all instructions before installing and using. Installer: This manual must be delivered to the end user.WARNING!Failure to install or use this product according to manufacturer’s recommendations may result in property damage, serious injury, and/or death to those you are seeking to protect! …
  • Satel

    Versa

    (32 pages)
    INSTRUCTIONS FOR OPERATING CONTROL PANEL FROM LED KEYPAD SATEL sp. z o.o. ul. Budowlanych 66 80-298 Gdańsk POLAND tel. +48 58 320 94 00 www.satel.eu versa_led_en 11/17 Alarm Control Panel Firmware Version 1.09 …
  • DUAL LITE

    LZ Series

    (2 pages)
    Final AssemblyEnergize unit. Charge a minimum of 24 hours prior to testing.4.Aim lamp heads towards center of unit and dress wires neatly to prevent pinching.1.➤2. Align housing slots over back plate tabs. Pivot housing and snap closed.3.Press test switch and hold. Aim lamp heads for proper light distribution.5.TROUBLE SHOOTINGAC-On Light does not illu …