Whirlpool GXW6530DXS2 Installation Instructions And Use & Care Manual
|
Whirlpool GXW6530DXS2, 1. Using 2 or more people, hang range hood on 2 mounting screws through the mounting slots on back of hood. / ?C S / A. Mounting screws B. Mounting slots C. Lower mounting screws 2. Remove the grease filter. See "Range Hood Care" section. 3. Level the range hood and tighten upper mounting screws. 4. Install 2 - 5 x 45 mm lower mounting screws and tighten. For vented installations only: 1. Fit vent system over the exhaust outlet. 2. Seal connection with clamps. 3. Check that backdraft dampers work properly. 2. Measure from the bottom of the air deflector to the bottom of the hood outlet. ........................ A. A
Whirlpool GXW6530DXS2, WHIRLPOOLCORPORATIONMAJORAPPLIANCEWARRANTY LIM ITED WARRANTY For one year from the date of purchase, when this major appliance is operated and maintained according to instructions attached to or furnished with the product, Whirlpool Corporation or Whirlpool Canada LP (hereafter "Whirlpool") will pay for Factory Specified Parts and repair labor to correct defects in materials or workmanship. Service must be provided by a Whirlpool designated service company. This limited warranty is valid only in the United States or Canada and applies only when the major appliance is used in the country in which it was purchased. Outside the 50 Uni
Whirlpool GXW6530DXS2, 2. Mesurer la distance entre le bas du deflecteur d'air et le bas C. X = Iongueur _ laquelle couper le conduit d'_vacuation D. Conduit d'_vacua tion E. Sortie d'_vacuation 3. Tailler le conduit & la taille mesuree (X). 4. Retirer le deflecteur d'air. 5. Faire coulisser le conduit sur le bas du deflecteur d'air. 6. Placer le deflecteur d'air et le conduit assembles sur la sortie d'evacuation de la hotte. 7. Reassembler le deflecteur d'air sur la bride de cache-conduit & I'aide des 4 vis d'assemblage. 8. Assurer I'etanch6it6 des connexions avec une bride de conduit. 3= 4= Oter I'opercule arrachable du boitie
WIRINGDIAGRAM GND _ N / (_ Y BU Motor (Ohms) Resistance Blue 37.7 Red Blue 30.3 Gray Blue Black 20.8 (MAX) Blue 45.1 (MAX) White Room 73°F (23°0) Temp. R O H W O_" / !J__1L / _ Switch Operation oLr_#oj_o _ "_ Position Connection o. .oCoooec,,oo _L _ High Speed L-Black (3) capacitor Med Speed L-Red (2) -4 r¢ r¢ CD m m r¢ q Low Speed L-White (1) Lamps L-Yello
Whirlpool GXW6530DXS2, TABLEOF CONTENTS RANGE HOOD SAFETY ................................................................. 2 INSTALLATION REQUIREMENTS ................................................ 4 Tools and Parts ............................................................................ 4 Location Requirements ................................................................ 4 Venting Requirements .................................................................. 5 Electrical Requirements ............................................................... 6 INSTALLATION INSTRUCTIONS ..............................................
Whirlpool GXW6530DXS2, ASSISTANCEORSERVICE When calling for assistance or service, please know the purchase date and the complete model and serial number of your appliance. This information will help us to better respond to your request. If you need replacement parts If you need to order replacement parts, we recommend that you use only factory specified parts. Factory specified parts will fit right and work right because they are made with the same precision used to build every new appliance. To locate factory specified replacement parts in your area, call us or your nearest designated service center. Call the Whirlpool Customer eXperience Center toll free: 1-800-253-1301 or visit our websit
Whirlpool GXW6530DXS2, £_6S,e Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock. 1. Disconnect power. 2. Remove terminal box cover. 3. Remove the knockout in the terminal box cover and install a UL listed or CSA approved 1/2"strain relief. 4. A A. Knockout B. Terminal box cover Run home power supply cable through strain relief, into terminal box. A D 5. Use UL listed wire connectors and connect black wires (C) together. 6. Use UL listed wire connectors and connect white wires (E) together. Electr
Whirlpool GXW6530DXS2, Secure the bottom of the duct with 2 - 4 x 8 mm screws. 1. For non-vented (recirculating) installations only, install charcoal filters over metal grease filter. See the "Range Hood Care" section. 2. Install metal filters. See the "Range Hood Care" section. 3. Check the operation of the range hood blower and light. See the "Range Hood Use" section. NOTE: To get the most efficient use from your new range hood, read the "Range Hood Use" section. RANGEHOODUSE The range hood is designed to remove smoke, cooking vapors and odors from the cooktop area. For best results, start t
Whirlpool GXW6530DXS2, # # • SECURITEDELAHOTTEDECUISINIERE Votre securite et celle des autres est tres importante. Nous donnons de nombreux messages de s_curit_ importants dans ce manuel et sur votre appareil m_nager. Assurez-vous de toujours lire tous les messages de s_curit_ et de vous y conformer. Voici le symbole d'alerte de s_curit& Ce symbole d'alerte de s_curit_ vous signale les dangers potentiels de d_c_s et de blessures graves & vous et & d'autres. Tousles messages de s_curit_ suivront le symbole d'alerte de s_curi
Whirlpool GXW6530DXS2, llVIPORTANTES iNSTRUCTiONS DE Sl CURITl AVERTISSEMENT : POUR REDUIRE LE RISQUE D'INCENDIE, CHOC ¢:LECTRIQUE OU DOMMAGES CORPORELS, RESPECTER LES INSTRUCTIONS SUIVANTES : m Utiliser cet appareil uniquement dans les applications envisag6es par le fabricant. Pour toute question, contacter le fabricant. m Avant d'entreprendre un travail d'entretien ou de nettoyage, interrompre I'alimentation de la hotte au niveau du tableau de disjoncteurs, et verrouiller le tableau de disjoncteurs pour emp6cher tout r6tablissement accidentel
Whirlpool GXW6530DXS2, # A SCHEMADECABLAGE Terre _ z Neu / JA BU Resistance moteur (ohms) Bleu 37.7 Rouge Bleu 30.3 Gris Bleu Noir 20,8 (MAX.) Bleu 45,1 (MAX.) Blanc Temp. ambiante 73°F (23°C) g q Vitesse Ph-Rouge moyenne (2) Vitesse Ph-Blanc (1) basse Lampes Ph-Jaune (LA) Caract@istiques de moteur Alimentation electrique 120 V CA Frequence 60 Hz Puissance 240 W absorbee 26
iMPORTANT SAFETY iNSTRUCTiONS WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: [] Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. [] Before servicing or cleaning the unit, switch power off at service panel and lock the service disconnecting means to prev
Whirlpool GXW6530DXS2, T 173/1_'' (43.7 cm) *For non-vented (recirculating)installations **For vented installations *'28W1_" (72.9 cm) rain. *'483/4" (123.8 cm) max. "321/8" (81.6 cm) rain. "527/8" (134.3 cm) max. Cabinet Dimensions 10" (25.4 cm) rain. 13" (33.0 cm) max. m,n.* 91/2'' 24 1 cm _'-'_'_ _Z_:_ 9 ( . ) _>. 1"'.....................! : ' .....................Vent and power 10,,(25.4 .................................soppJycabJe 13"(33.0 " i 1 entry location .......... I 20"(50.8ore)*rain.
Remplacement d'une lampe €:teindre la hotte; attendre le refroidissement de la lampe. Pour 3. Retirer le protege-ampoule et le mettre de c6te avec la vis. eviter d'endommager ou de reduire la Iongevit6 de I'ampoule neuve, ne pas toucher I'ampoule avec les doigts nus. Remplacer I'ampoule en la manipulant avec un mouchoir de papier ou de
Whirlpool GXW6530DXS2, 30" AND 36" (76.2 CM AND 91.4 CM) WALL- MOUNT CANOPY RANGE HOOD For questions about features, operation/performance parts, accessories or service, call: 1-800-253-1301. In Canada, call for assistance 1-800-461-5681, for installation and service, call: 1-800-807-6777 or visit our website at... www.whirlpool.com or www.whirlpool.com/canada HOI'I'E D'EXTRACTION A MONTAGE MURAL DE 30" ET 36" (76,2 CM ET 91,4 CM) Au Canada, pour assistance, composez le 1-800-461-5681, pour installation ou service 1-800-807-6777 ou visitez notre site web www.whirlpool.ca Table of Contents/Table des matieres .............
Whirlpool GXW6530DXS2, ASSISTANCEOUSERVICE Lors d'un appel pour assistance ou service, veuillez connaYtre la date d'achat, le numero de modele et le numero de serie complets de I'appareil. Ces renseignements nous aideront & mieux repondre a votre demande. Si vous avez besoin de pi_ces de rechange Si vous avez besoin de commander des pieces de rechange, nous vous recommandons d'employer uniquement des pieces specifiees par I'usine. Les pieces specifiees par I'usine conviendront et fonctionneront bien parce qu'elles sont fabriquees avec la meme precision utilisee dans la fabrication de c
Whirlpool GXW6530DXS2, • La Iongueur du circuit d'evacuation et le nombre de coudes doit _tre reduit au minimum pour fournir la meilleure performance. Pour un fonctionnement efficace et silencieux : • Ne pas utiliser plus de trois coudes a 90°. • Veiller ace qu'il y ait une section droite de conduit de 24" (61,0 cm) ou plus entre deux coudes, si on doit utiliser plus de un raccord coud& • Ne pas connecter 2 coudes ensemble. • Au niveau de chaque jointure du circuit d'evacuation, assurer I'etanch6it6 avec les brides de serrage. • Le circuit d'evacuation doit comporter un clapet anti-reflux. Si la bouche de decharge murale ou par le toit comporte un
Whirlpool GXW6530DXS2, 10. Installer les 2 vis de montage de 5 x 45 mm. Laisser un espace de 1/4"(6,4 mm) entre lemur et I'arriere de la t_te de vis pour faire glisser la hotte et la mettre en place. v4"_ t_ (6,4 ram) _ Installation de la bride de cache-conduit 11. Fixer la bride du cache-conduit au mur en affleurement avec le plafond & I'aide de 2 vis de 5 x 45 mm. / / / / / / / / / / / / t" A. Plafond B. Mur C. Axe central Achever la preparation 1. Determiner et effectuer tousles decoupages necessaires dans lemur pour le passage du circuit d'evacuation. Installer le circuit d'evacuation avant la hotte. Voir la section "Exigence
Whirlpool GXW6530DXS2, Dimensions du produit Dimensions du placard 10%" (27,6 cm) 13¾o" 36"(91,4cm) ] 17¾o" (43,7 cm) *'28W16" (72,9 cm) rain. **48¾" (123,8 crn) max. "321/8" (81,6 crn) rnin. *52%" (134,3 crn) max. *Installations sans decharge a I'exterieur (recyclage) **Installations avec decharge a I'exterieur 10" (25,4 crn) rnin. Pointa'entr e rn n i :: ..........................................du circuit 10" (25,4 crn) max _ _ i ::'d&apos
Whirlpool GXW6530DXS2, For Non-Vented (recirculating) Installations If it is not possible to vent cooking fumes and vapors to the outside, the hood can be used in the non-vented (recirculating) version, fitting a charcoal filter and the deflector. Fumes and vapors are recycled through the top grille. Roof Venting Wall Venting Non-vented (recirculating) .................A AJ A A. Roof cap A. Wall cap A. Deflector B. 6" (15.2 cm) B. 6" (15.2 cm) B. 6" (15.2 cm) round vent round vent round vent Calculating
Whirlpool GZ7736XGS Ventilation Hood Limited warranty
GZ7736XGS |
Whirlpool RH2336XJQ0 Ventilation Hood Parts list
RH2336XJQ0 |
Whirlpool YMH1150XM Ventilation Hood Use & care manual
YMH1150XM |
Whirlpool RH2636XJ Ventilation Hood Parts list
RH2636XJ |
Whirlpool GXI6536DXS2 Ventilation Hood Installation instructions and use & care manual
GXI6536DXS2 |
Whirlpool GXU7130DXB Ventilation Hood Installation instructions and use and care manual
GXU7130DXB |
Whirlpool Microwave Hood Combination Ventilation Hood Installation instructions manual
Microwave Hood Combination |
Whirlpool GZ7930XHS1 Ventilation Hood Parts manual
GZ7930XHS1 |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | M&S Systems | dmc1 | Instructions manual | m-s-systems/dmc1-KY2.pdf | 22 Dec 2022 | 16 | |
2 | Thermal Arc | 300GTSW Pro-Wave | Service manual | thermal-arc/300gtsw-pro-wave-413.pdf | 25 Nov 2022 | 130 | |
3 | Exergen | TAT-2000C | Instructions for use & warranty | exergen/tat-2000c-56E.pdf | 12 May 2023 | 2 | |
4 | Power Wheels | Automobile Parts | Instructions manual | fisher-price/automobile-parts-67R.pdf | 04 Feb 2023 | 48 | 0.43 Mb |
5 | MegaLite | axis xtra 17R | Operation & user’s manual | megalite/axis-xtra-17r-673.pdf | 24 Jan 2023 | 16 | |
6 | Focal | DUAL MANAGER | Manual | focal/dual-manager-811.pdf | 15 Nov 2023 | 36 | 3.75 Mb |
Cata
Manual de instalación, uso y mantenimiento de campanas decorativas ESHandbuch zu Installation, Bedienung und Wartung von dekorativen Abzugshauben DEManuel d’installation, d’utilisation et d’entretien des hottes décoratives FRManual for the installation, use and maintenance of decorative hoods ENManuale di installazione, uso e manutenzione di cappa as …
omega(8 pages) |
Smeg
INSTRUCTIONS FOR INSTALLATION AND USEMONTAGE- UND GEBRAUCHSANWEISUNGINSTRUCTIONS POUR L'INSTALLATION ET L’UTILISATIONISTRUZIONI PER L'INSTALLAZIONE E L’USOINSTRUCCIONES PARA INSTALACIÓN Y USOINSTRUÇÕES DE INSTALAÇÃO Y UTILIZAÇÃOAANWIJZING VOOR GEBRUIK EN INSTALLATIE
…
K24SLM90(20 pages) |
Amana
30" AND 36" (76.2 AND 91.4 CM) RANGE HOODInstallation Instructions and Use & Care GuideHOTTE DE CUISINIÈRE DE 30" ET 36" (76,2 ET 91,4 CM)Instructions d’installation et Guide d’utilisation et d’entretienTable of Contents/Table des matières .....................................2IMPORTANT: READ AND SAVE THESE INSTRUCTIONS. …
UXT5530AAS(28 pages) |
Faber
Version 07/11- Page 1CYLINDRAWall Mount RangehoodREAD AND SAVE THESE INSTRUCTIONS� …
Cylindra(18 pages) |
Salda
La société se réserve le droit de modier les données techniques sans préavis. Änderungen in Konstruktion und Design sind vorbehaltenПроизводитель оставляет за собой право усовершенствования технических данных Subject to technical modicationVSA 3.0_P0071_AL_0001TOURELLESКРОВ� …
VSA 220 M 3.0(12 pages) |
FALMEC
INSTRUCTIONS BOOKLETIT LIBRETTO ISTRUZIONIEN INSTRUCTIONS BOOKLETDE GEBRAUCHSANWEISUNGFR MODE D'EMPLOIES MANUAL DE INSTRUCCIONESRU ɂɇɋɌɊɍɄɐɂɂPL INSTRUKCJA OBSŁUGINL HANDLEIDINGPT MANUAL DE INSTRUÇÕESDK BRUGSANIVSNINGERSE INSTRUKTIONSBOKFI OHJEKIRJANO BRUKSANVISNINGLuminaPlaneIsland/Isolafalmec.comMADE IN VITTORIO VENETO (TV) - ITALY
…
Lumina Series(80 pages) |
Philips Boiler GC6002/03Philips GC6002/03 Boiler Operation & user’s manual GC6002/03, 56 |
Pioneer Music Mixer CDJ-900#EJI435: CDJ-900 Music Mixer Operating instructions manual CDJ-900, 32 |
Motorola Pager 6881029B15-AGuide: Motorola 6881029B15-A (FFG7V5, Upd.Monday 27-11-2023) 6881029B15-A, 33 |
Acson Remote Control OM-G8-0501-OM-G8-0501- Operating instructions manual - KW6G5K OM-G8-0501-, 16 |
NETGEAR Wireless Router WN2000RPTv1NETGEAR WN2000RPTv1 Guide (Doc Type: Wireless Router Installeringsveiledning) WN2000RPTv1, 2 |
Jiffy Electric Steamer Esteam#6UTRX2: Esteam Electric Steamer Owner's manual Esteam, 84 |
HAI Thermostat RC-80 OmnistatThermostat #K8V79L RC-80 Omnistat, 16 |
AEG Cooktop 24" HK654070XBAEG 24" HK654070XB Guide (Doc Type: Cooktop Operation & user’s manual) 24" HK654070XB, 19 |
RIDGID Pressure Washer KJ-5000RIDGID Product User Manual: KJ-5000 PDF Manual - IJQ6TJ KJ-5000, 19 |
HEIDENHAIN Control Unit TNC 151 QHEIDENHAIN TNC 151 Q Manual (Mounting instructions), @D76PPG TNC 151 Q, 119 |
Yealink IP Phone W52PYealink W52P IP Phone Quick start manual W52P, 28 |