Manualios.com

Eneo KBD-NSC-100 Installation And Operating Manual

  • KBD-NSC-100 Network Card
  • mapBpIsCtQ2RI
  • Installation And Operating Manual
  • PDF / Adobe Acrobat Reader
  • 40

Eneo KBD-NSC-100 Manual Online:

4.8, 2127 votes
Eneo KBD-NSC-100 User Manual
Eneo KBD-NSC-100 User Guide
Eneo KBD-NSC-100 Online Manual

Text of Eneo KBD-NSC-100 User Guide:

  • Eneo KBD-NSC-100, 32 – ID: Assign a unique ID from 1 to 100 to the macro. When giving a ‘macro ID’ –> command, the network keyboard performs the actions registered on the macro. – Name: Enter a macro name. – No.: Displays the order of the macro. The network keyboard takes actions according to the order when performing the macro. – Button: Double click the field, and then click a button on the network keyboard image in the left to assign the operation to perform. – Dwell Time: Enter dwell time (sec.) for the action to last. Button • Button: Displays the function button of the network keyboard. • Function: Select the function to perform when pressing t

  • Eneo KBD-NSC-100, 26 5. Remote Configuration The Remote Setup allows you to change all settings of the network keyboard. Run the INIT program, select a network keyboard to change settings and click the Setup icon on the Main screen. Select Remote Setup from the Setup menu and the Remote Setup screen appears. Clicking a menu in the left of the Remote Setup screen displays the current settings for that menu in the right of the screen. Clicking a submenu under each menu allows you to change the settings. Clicking the OK button closes the Remote Setup screen and applies the changes. 5.1 System You can change system informatio

  • Eneo KBD-NSC-100, 4 1.2 Typical Applications PTZ Camera Control You can control PTZ cameras via RS-485 connection. Refer to Chapter 2 – Installation, 2.1 PTZ Camera Registration for details. DVR System Control via RS-485 Connection You can control DVRs and PTZ cameras connected to the DVRs via RS-485 connection. Refer to Chapter 2 – Installation, 2.2 DVR System Registration, Basic Mode and Chapter 3 – Operation, 3.3 DVR System Control for details on installation and operation. PTZ Cameras RS485 PTZ Network Keyboard Cameras 1 ~ 16 RS485 DVR Network Keyboard

  • Eneo KBD-NSC-100, 19 Example II (Advanced Mode) Cameras 1 ~ 16 DVR Video Out 1. Press the monitor ID. 2. Press the button. You can control the DVR that the monitor is connected by using device control buttons if the monitor is a main monitor. 3. Press the camera ID. 4. Press the button. Video from the camera is displayed in the selected monitor, and you can control the camera by using PTZ control buttons if the camera is a PTZ camera. 3.4 MMX System Control You can control MMXs, DVRs connected to the MMX and PTZ cameras connected to the DVRs via network connection. It is required to log in a user with the authority over the function to control depending on the function when controlling D

  • 27 Button • Beep: Check the box to beep when pressing the buttons of the network keyboard. • Lock: The buttons of the network keyboard will be locked when there is no action in the network keyboard during the preset time since the last action. Unlocking the buttons requires entering the User password. This function does not work if the User pass

  • Eneo KBD-NSC-100, 14 5.3. Click the Digital Video Recorder pull-down menu in the device list, and then the registered DVR’s pull-down menu. A list of monitors and cameras supported in the DVR is displayed. • [ID] Main Monitor: Displays the monitor ID and type. • [ID] Spot Monitor No.: Displays the monitor ID, monitor type and the Spot Out number of the DVR. • [ID] „Camera Name”: Displays the ID and name of the camera. 5.4. Click a camera in the list

  • Eneo KBD-NSC-100, 29 5.3 Device General You can set up the setup mode and register PTZ cameras, network cameras, network video transmitters, network receivers, DVRs and MMXs to control by using a network keyboard. • Setup type: Select Basic or Advanced when controlling devices via RS-485 connection only, or select Advanced when controlling devices via network and RS-485 connections. – Port: Select the device to control via RS-485 connection from the drop-down list, and set up the port information for RS-485 communication. The port information is set up separately for PTZ cameras and DVRs. If

  • Eneo KBD-NSC-100, 5 DVR System Control via Network Connection You can control DVRs and PTZ cameras connected to the DVRs via network connection. Refer to Chapter 2 – Installation, 2.2 DVR System Registration, Advanced Mode and Chapter 3 – Operation, 3.3 DVR System Control for details. Cameras 1 ~ 16 Network Keyboard Spot Monitor Main Monitor Spot Out Video Out Video In DVR DVR Cameras 1 ~ 16 RS-485 Video In RS-485 Spot Out Video Out Spot Monitor Main Monitor

  • Eneo KBD-NSC-100, 33 7. Technical Specifications Type KBD-NSC-100 Art. No. 74746 Operation mode Single operation Audio inputs 1 (Microphone) Audio output 1x Loudspeaker (mono/stereo, 3.5mm jack) Joystick 3-axis proportional joystick for manual control of variable speed Site control (direct mode operation) Keys select cameras and monitors, operate presets, patterns, auxiliaries and sequences. Camera functions: pan, tilt, zoom, focus, iris for fixed or variable speed control of the camera series Fastrax, Minitrax Contr

  • Eneo KBD-NSC-100, 10 2. Installation A device should be registered on the network keyboard properly for control by a network keyboard. The Basic mode and Advanced mode are supported for registration and control of the device, and the device is controllable only in the mode which the device is registered on. When controlling devices via RS-485 connection only, you can register the devices in the Basic mode or in the Advanced mode. When controlling devices via network and RS-485 connections, you can register the devices in the Advanced mode only. Both the LCD menu and the INIT program are

  • Eneo KBD-NSC-100, 30 General – Advanced Mode You can control devices via network and RS-485 connections when registering the devices in the Advanced mode. • Scan, Add, Edit: See below. • Remove, Remove All: Select a device in the list and click the Remove button to delete it. Clicking the Remove All button deletes all devices from the list. • Scan: Click to find and list up devices connected to a network. (Network cameras, network video transmitters, network video receivers and MMXs only) – Auto Scan: Click to reload the list of the device networked via LAN. – Manual Scan: Click the button and enter the IP address of the de

  • Eneo KBD-NSC-100, 38 Button Designation Operation Enable Speaker / Mic • : Receives audio from the remote site through the speaker when controlling a camera. Pressing the button again disables the function. • & : Sends audio to the remote site through the microphone when controlling a camera. Pressing the button again disables the function. • Receiving and sending audio is available only when controlling a device that supports two-way audio communication via network connection. Also, the audio channels for two-way audio communication should be set up when registering the device. This might not work properly if the network keyboard performs other functions

  • Eneo KBD-NSC-100, 9 1.5 Top Panel No. Designation Details 1 Joystick Controls pan and tilt of a PTZ camera by using the stick or zoom of a PTZ camera by using the shuttle ring. 2 PTZ Camera Control Buttons Controls the PTZ camera by setting up presets or expanded PTZ features. Refer to Appendix 2 – Buttons, PTZ Camera Control for details. 3 LCD Screen Displays operation commands or LCD menus. Refer to Chapter 3 – Operation and Chapter 4 – LCD Menu Configuration for details. 4 Device Control Buttons Controls remote devices including DVRs. Refer to Appendix 2 – Buttons, Device Cont

  • 35 APPENDIX 2 Buttons NOTE: In the operation explanation for each button, „ –> ” indicates that the buttons are pressed sequentially, and „&” indicates the buttons are pressed together. Operation Command NOTE: Devices should be registered on the network keyboard and set up properly to perform the commands. Button Designation Operation Number (1 to 9) • Device numbe

  • 17 Locking Buttons Pressing the and buttons together locks the buttons of the network keyboard. You can set up the buttons to be locked by using the LCD menu or the INIT program when there is no action on the network keyboard during the preset time since the last action. This function does not work if the User password is not set up or the button lock

  • Eneo KBD-NSC-100, 2 Contents Safety Instructions / Maintenance .............................................................................................................................................................................................3 1. Introduction ................................................................................................................................................................................................................... 3 1.1 Features .........................................................

  • Eneo KBD-NSC-100, 12 5. Go to the following menus: Setup –> Remote Setup –> Device –> Setup 5.1. Click Digital Video Recorder in the device list, and then the Add button to register the DVR. 5.2. Set up the registration information and click the OK button. • ID: The network keyboard assigns the ID automatically when the DVR is registered, and you can change the ID. The ID will be used to distinguish the DVR from other devices when controlling the DVR by using a network keyboard, so each device should have its own unique ID. • Connection: Select RS-485 or Ethernet depending on the connection

  • Eneo KBD-NSC-100, 8 1.4 Bottom Panel No. Designation Details 1 Joystick Bracket Use to attach the joystick provided with the network keyboard body to the network keyboard body. The joystick can be attached either to the left or to the right of the network keyboard body. 2 Factory Reset Switch Returns all settings to the original factory settings. Refer to Factory Reset for details. 3 Joystick Input Port Connect a joystick cable. A joystick cable should be connected while the network keyboard is powered down. 4 RS485 DVR Termination (1) Set the switch to ON if RS-485 communication environment is not good and the connection is not made when controlling a DVR via RS-485 connection. 5 RS485 PTZ

  • Eneo KBD-NSC-100, 11 2.2 DVR System Registration You can register a DVR to control via RS-485 or network connection. In the Basic mode, the DVR’s system ID set in each DVR is required to control DVRs. In the Advanced mode, the user-defined ID registered on the network keyboard is required to control DVRs. Basic Mode You can control a DVR with the DVR’s system ID after setting up the port information for the RS-485 communication without registering the DVR. Refer to Chapter 5 – Remote Configuration, 5.3 Device for details on the remote setup. The following is about th

  • Eneo KBD-NSC-100, 15 6.3. Click a monitor in the list, and then the Edit button. Set up the monitor ID. The network keyboard assigns the ID automatically when the MMX is registered, and you can change the ID. The ID will be used to distinguish the monitor from other monitors when controlling it by using a network keyboard, so each monitor should have its own unique ID. 6.4. Click a camera in the list, and then the Edit button. • When the camera is connected to the Video In port of the MMX through th

  • Eneo KBD-NSC-100, 34 APPENDIX 1 RS-485 Connector Pin Outs RS485 PTZ Connector RS485 DVR Connector Master Unit Slave Unit + –> to –> TX+/RX+ – –> to –> TX–/RX– Master Unit Slave Unit + –> to –> TX+/RX+ – –> to –> TX–/RX–

Related Products and Documents (Network Card):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 MTD 648D Owner's manual mtd/648d-8SD.pdf 04 Dec 2022 12
2 Omega Freedom 400 Owner's manual omega/freedom-400-RQC.pdf 09 Feb 2024 34
3 Fiat 500c Manual  fiat/500c-NLT.pdf 28 Jun 2023 40
4 Apple XSERVE Xserve G5 Technology overview apple/xserve-xserve-g5-364.pdf 05 Oct 2023 30 1.09 Mb
5 Harbinger HPX215 - BBE Owner's manual harbinger/hpx215-bbe-9IT.pdf 15 May 2023 16
6 Hatco TK-72 Datasheet hatco/tk-72-344.pdf 19 Nov 2023 1 0.1 Mb

Similar Resources:

  • D-Link

    DWL-G630 - AirPlus G 802.11g Wireless PC Card

    (56 pages)
    WIRELESS G NOTEBOOK ADAPTERDWL-G630QUICK INSTALLATION GUIDEINSTALLATIONSANLEITUNGGUIDE D’INSTALLATIONGUÍA DE INSTALACIÓNGUIDA DI INSTALLAZIONEINSTALLATIEHANDLEIDINGINSTRUKCJA INSTALACJIINSTALAČNÍ PŘÍRUČKATELEPÍTÉSI SEGÉDLETINSTALLASJONSVEILEDNINGINSTALLATIONSVEJLEDNINGASENNUSOPASINSTALLATIONSGUIDEGUIA DE INSTALAÇÃOΟΔΗΓΌΣ ΓΡΉΓΟ� …
  • Patton electronics

    IM1/K

    (11 pages)
    USERMANUALMODELS IM1/K and IM2RC/KG.703/G.704 QuikConnect™and Rear Card ModulesSALES OFFICE(301) 975-1000TECHNICAL SUPPORT(301) 975-1007http://www.patton.comPart# 07MIM1/K-CDoc# 090131UCRevised 08/01/00CERTIFIEDAn ISO-9001CertifiedCompany …
  • StarTech.com

    ST1000SPEXD2

    (9 pages)
    Manual Revision: 07/18/2011For the most up-to-date information, please visit: www.startech.comDE: Bedienungsanleitung - de.startech.comFR: Guide de l'utilisateur - fr.startech.comES: Guía del usuario - es.startech.comIT: Guida per l'uso - it.startech.comNL: Gebruiksaanwijzing - nl.startech.comPT: Guia do usuário - pt.startech.comST1000SPEXD2Dual …
  • CyberData

    VoIP Card Reader/Network Device Module

    (2 pages)
    Stand-AloneVoIP Card Reader/Network Device ModuleFeatures 3-track Magnetic Card Reader RFID Reader Optional hand scanner interface Pass-through Ethernet 10/100Mbps hub Mounts onto Cisco 7xxx series phone foot stand Stand-alone desktop stand Low Profile and Small Footprint Field upgradeable firmware LED indicator provides status of …
  • TRENDnet

    TEW-441PC - 108Mbps Wireless PC Card TEW-441PC

    (9 pages)
    i Regulatory notes and statements Wireless LAN, Health and Authorization for use Radio frequency electromagnetic energy is emitted from Wireless LAN devices. The energy levels of these emissions however are far much less than the electromagnetic energy emissions from wireless devices like for example mobile phones. Wireless LAN devices are safe for use frequ …
  • SMC Networks

    SMC6224M

    (522 pages)
    TigerStack 10/10024/48-Port 10/100Mbps Stackable Managed SwitchManagement Guide◆ 24/48 auto-MDI/MDI-X 10BASE-T/100BASE-TX ports◆ 2 Gigabit RJ-45 ports shared with 2 SFP transceiver slots◆ 2 Gigabit stacking ports that act as Ethernet ports in standalone mode◆ Stacks up to 8 units (SMC6224M) ◆ Stacks up to 4 units (SMC6248M)◆ Non-blocking switchin …

Comments, Questions and Opinions: