Manualios.com

England's Stove Works 10-CDV Installation And Operation Manual

England's Stove Works 10-CDV Manual Online:

3.15, 2444 votes
England's Stove Works 10-CDV User Manual
England's Stove Works 10-CDV User Guide
England's Stove Works 10-CDV Online Manual

Text of England's Stove Works 10-CDV User Guide:

  • England's Stove Works 10-CDV, 13 OPERATING INSTRUCTIONS CAUTION: DO NOT OPERATE WITH THE DOOR OPEN. If door is left open (approximately) two minutes, unit will stop feeding and fire will go out. Do not burn trash (paper bags, etc.) in this unit. This stove has an induced draft system and is designed to operate continuously, as frequent shutdown is not required. The setting of the “Heat Range” touch pad will control the heat output and the amount of fuel the unit will burn (see “Control Board” section and Illustration 4). Note: This stove is using solid fuel and will not restart automatically. * NOTE: Blower Speed will automatically be adjusted to the desired Heat Range that you selec

  • 22 ACCESSORY ITEMS The following accessories can be added to your unit at anytime after purchase; however, let the unit cool down before adding any accessories. Thermostat WALL: An external wall thermostat (such as our Part # GU-1E30-914) can be used on our corn/pellet units as long as it is a low-voltage that works with millivolt systems. After

  • 28 TROUBLE SHOOTING (Unit must be OFF, unplugged and cool before any maintenance) PROBLEM CAUSE: Too rich air/fuel mixture Fire burns with a lazy, orange flame and/or fuel builds up in the firepot. Glass may become dirty. Flue or intake is restricted. Make sure glass door is shut and sealed tightly. If not, adjust door handle or replace gasket if necessary. Ve

  • England's Stove Works 10-CDV, CIRCUIT BOARD FUNCTIONS COMPONENT OPERATION START OPERATION END Exhaust Blower Starts Immediately Will continue until shutdown. Shutdown will occur when the operating temp. is below 90 degrees. Agitator Three minutes after starting, the agitator will begin to turn. Will continue intermittently, as determined by the Heat Setting, until Shutdown Auger Three minutes after starting, the auger will begin to turn. The auger will continue at the feed rate determined by the Heat Setting. NOTE: Safety switch, Hi Limit and Vac

  • England's Stove Works 10-CDV, 18 MAINTENANCE CAUTION: UNPLUG THE UNIT PRIOR TO ANY SERVICE WORK! SEE EXPLODED DIAGRAM (ILLUSTRATION 6) FOR PARTS REFERENCE Note: To do any service on this unit the rear access sheet metal panel must be removed. One (1) screw holds this panel to the rear of the stove. Parts Orders: (800) 516-3636 www.englanderstoves.com Questions: (800) 245-6489 Visit our web site for information that details and illustrates the following maintenance tasks. Auger Motors The Auger Mot

  • England's Stove Works 10-CDV, Ash Pan Latch Illustration 8 Dimensions of your corn/pellet unit: 28”W x 33”H x 28”D 350 lbs. (Approx.18” height from floor to center of exhaust) Illustration 9 Base Options and Details DIRECTIONS FOR INSTALLATION OF LEGS OR PEDESTAL: (Stove must be cooled and all ashes cleaned out) * Remove bricks, disconnect flue, and turn stove on its back. * If you are replacing existing legs or pedestal, disconnect the existing legs or pedestal.

  • England's Stove Works 10-CDV, 15 E-Codes “E-Codes,” or Error Codes, are codes that will appear in the Heat Range and Blower Speed windows of the Control Board if your unit experiences problems. If you receive these codes, wait until the unit is cooled completely down before trying to restart your unit. If the unit continues to display any E-Code(s), please contact Customer Service at (800) 245-6489 before further attempting to restart your unit. E-2 = Fail to Start NOTE: “E-0” indicates “No Error” First Fire: When you push the “ON” button, the Control Board w

  • England's Stove Works 10-CDV, A letter from our Technical Support department: Thank you for purchasing this fine product from England’s Stove Works! England's Stove Works was started, and is still owned by, a family that believes strongly in a "Do It Yourself" spirit – that’s one reason you found this product at your favorite “Do It Yourself” store. We intentionally design and build our stoves so that any homeowner can maintain his or her unit with basic tools, and we're always more than happy to show you how to do the job as easily and as inexpensively as possible. From our free, downloadable service sheets; to our Corn and Pellet Servi

  • REPLACEMENT PARTS, ACCESSORIES AND OPTIONS ITEM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 PART NUMBER CA-13C AC-G10 AC-GGK AC-DGKNC CU-GS CU-CFB CU-BP CA-FS CU-SC CA-DS CU-MC CU-AFC CU-RCP CU-047042 CU-CB05 CU-VS CU-AP CU-BR PU-103-50 PU-CBG PU-076002B CU-LCP CA-AT CU-RGN C

  • 9 BURNING SOLID FUELS Ashes will need to be removed from the unit periodically. See Ash Removal section. You can minimize cleaning required and maximize efficiency by maintaining the proper draft. This unit has been designed to burn dry shelled corn or premium hardwood pellets that meet the association of pellet fuel industry standards. Shelled corn (dry, preferably corn with 11

  • England's Stove Works 10-CDV, 12. Horizontal runs should not exceed four feet (4’) with a maximum vertical flue height of thirty five feet (35’). At fifteen feet (15’), the pipe should be increased to four inch (4”) corn vent pipe. 13. This unit should be turned off and allowed to cool prior to cleaning. Any ashes should be kept in an airtight metal container and not disposed of until they are completely cooled. 14. Read the instructions thoroughly, including instructions concerning the digital control board, and save them for future reference. 15. Do not allow paint, chemicals or constru

  • England's Stove Works 10-CDV, INSTALLATION & OPERATION MANUAL MODEL NUMBERS: 10-CDV 49-TRC22 49-SHC22 Thank you for purchasing this product from a fine line of heating equipment. We wish you many years of safe heating pleasure with your new heating appliance. Save These Instructions. IMPORTANT: IF YOU HAVE A PROBLEM WITH THIS UNIT DO NOT RETURN IT TO THE DEALER. CONTACT CUSTOMER SERVICE @ 1-800-245-6489. Mobile Home Use: These freestanding corn/pellet units are approved for mobile home or doublewide installation with outside combustion air hook-up. See “Flue System” section of manual. Mobile home ins

  • England's Stove Works 10-CDV, Notes on termination of Vent Pipe (see also “FLUE SYSTEM” section of manual): 1. Not less than three (3) feet above any forced air inlet located within ten (10) feet. 2. Not less than four (4) feet below, four (4) feet horizontally from, or one (1) foot above any door, window or gravity air inlet into any building. 3. Not less than two (2) feet from an adjacent building, and not less than seven (7) feet above grade where located adjacent to public walkways. The exhaust exit shall be arranged so that the flue gases are not directed so that it will affect people, overheat co

  • England's Stove Works 10-CDV, 17 ASH REMOVAL AND DISPOSAL IMPORTANT: While the amount of ash generated by this unit is not excessive compared to log-burning woodstoves, keeping the unit clean and free of ash is essential for peak performance. Too much ash build-up hampers airflow and reduces the unit’s efficiency, and can cause smoke-back. Daily Ash Maintenance Press the “OFF” touch pad and allow the stove to burn for five (5) minutes prior to opening the door. A long-handled screwdriver or long-handled putty knife can be used to scrape off any build-up or crust in the burn pot area. This can then be pushed to the left o

  • England's Stove Works 10-CDV, Finish This new unit has been painted with High-Temperature Paint that should retain its original look for years. If the unit should get wet and rust spots appear, the spots can be sanded with plain steel wool and repainted. We recommend this paint, as others may not adhere to the surface or withstand the high temperatures. Glass This unit has a ceramic glass (Part # AC-G10, comes with gasket) in the viewing door. Surface scratches are acceptable, but if this glass becomes cracked in any area, the unit should be shut down and

  • England's Stove Works 10-CDV, CORN START-UP PROCEDURE When starting the stove with corn, push the “AIR ON TEMP” button and hold, which will rotate the stirrer mechanism in the burn pot. Release the button when the stirrer is strait up (in the “12:00” position) before following the above instructions concerning placing the handful of pellets in the fire pot and starting your fire. Changing from Corn to Pellets Your unit was primarily designed to burn corn, but will also burn hardwood pellets. Your unit comes ready to burn corn by default; if you wood like to burn pellets in your unit, follow the steps below. WARNING: Do not open the door on this unit if the stirrer is still

  • England's Stove Works 10-CDV, 3 IMPORTANT INFORMATION 1. Installation of this pellet/corn unit should be performed by a professional only. Check local installation codes for your area. Call your Homeowner’s Insurance representative for inspection of your stove’s installation. 2. Read and comply with the instructions in this manual. 3. This unit should be tested (dry run) for 20 minutes before loading corn or pellets. The stove should automatically shut itself off after the 20-minute dry run. 4. Your stove is designed to burn Premium Pellet

  • England's Stove Works 10-CDV, UNIT PREPARATION 1. Attach the spring handle to the door by turning it counterclockwise. Important: Also check hopper latch – must be tight so that the top is sealed to prevent back-burn. 2. Test your 110-volt outlet for current and then plug in the unit. (We highly recommend a surge protector for our unit, as the control panel is electronic). 3. Be sure to “dry run” your unit for 20 minutes before connecting it to the flue. During this time the blowers and auger will operate at different times throughout the 20-min

  • England's Stove Works 10-CDV, Control Board The Control Board (Part # CU-CB05) is a digital read-out board. This board offers a wide variety of settings to operate the unit. This part can be removed from the unit by loosening the two outside screws and pulling the board back to the inside of the stove. The rear access panel should be removed prior to removing the control board. A 6-amp “quick-blow” fuse is used on this Control Board. NOTE: The bottom three control buttons are preset at the factory and should not require any changes. See “Operating Instructions” and “Daily Operation” section of the manual for instructions on other Control Board se

  • England's Stove Works 10-CDV, Through the Ceiling When venting the stove through the ceiling, the pipe is connected the same as through the wall, except the clean out tee is always on the inside of the house, and a 3” adapter is added before the clean-out tee. You must use the proper ceiling support flanges and roof flashing supplied by the pipe manufacturer -- follow the pipe manufacturer’s directions and Illustration 1 in this manual. It is important to note that if your vertical runs of pipe are more than fifteen feet (15’) at this p

  • England's Stove Works 10-CDV, Adjusting your Hopper Lid Latch The seals around the top of the pellet hopper are important to safe an efficient operation of the unit. The latch installed on these units is designed to pull the hopper lid tight against this seal. Over the course of operation as these seals “wear in” and compress, the tension of the latch should be tested periodically, and adjusted if necessary. To adjust the lid latch, the following tools will be needed; two ½ inch wrenches, or a ½ inch wrench and a ½ inch socket. In order to adjust the latch, first open the hopper lid and then lock the latch in its closed position. Then take the ½ inch wrench an

  • England's Stove Works 10-CDV, 31 WARRANTY REGISTRATION for England’s Stove Works Purchased by (Name) ______________________________________________ Address _________________________________________________________ City ________________________ State __________ Zip _________________ Telephone _______________________________________________________ Email Address ___________________________________________________ DEALER INFORMATION Purchased From (Dealer) ___________________________________________ Address _________________________________________________________ City _______________

  • England's Stove Works 10-CDV, 1. If 3” flue pipe exceeds 15’ in length, increase to 4” flue pipe for remaining flue connections. 2. Total flue length should not exceed 35’. 3. Horizontal run not to exceed 4’. 4. Floor protector required: Min. size 36” x 36”. 5. If the total run of outside air connection exceeds 6’, if more than 2 elbows are used, or if a basement install, use 3” metal pipe (and coupler) instead. 6. Outside Air is mandator y f or p ro p er sa f e o p eration. Freestanding Corn/Pellet Installation Caution: Follow the pipe manufacturer’s installation i

  • England's Stove Works 10-CDV, 16 DAILY OPERATION Refueling the Unit Always press the “OFF” touch pad before refueling. This stove has a approximately 80-lb. hopper, and should be refilled when the hopper level drops to three or four inches. Note: The hopper lid will be warm; therefore, you should always use some type of hand protection. NEVER place your hand near the auger while the stove is operating. Note: Always ensure that all corn and pellet matter is cleared from the hopper lid gasket before closing. Be sure to close and latch ho

  • England's Stove Works 10-CDV, 8 • Distance from bottom of termination and grade - one foot (1 ft.) minimum. This is conditional upon the plants and nature of the grade surface. The exhaust gases are hot enough to ignite grass, plants, shrubs, etc. located in the vicinity of the termination. The grade must not be a lawn. Distance from bottom of termination and public walkways is seven feet (7 ft.) minimum. • Distance to combustible materials – two feet (2 ft.). This includes adjacent buildings, fences, protruding parts of the structure, roof overhang, plants and shrubs, etc. • The installation must include a cleanout tee to enable the collection of fly ash an

  • England's Stove Works 10-CDV, FLUE SYSTEM Caution: Follow the pipe manufacturer’s installation instructions and directions for passing through combustible walls and ceilings. Be sure to check local codes in your area. NOTE: See the installation drawing later in this manual (Illustration 1). This unit is equipped with a negative draft system that pulls combustion air through the burn pot and pushes the exhaust air out of the dwelling. If this unit is connected to the flue system other than the way explained in this manual, it will not function properly. For any of these installations, keep in mind that each elbow used reduces draft by up to 30%; it is good practice to add 3�

  • England's Stove Works 10-CDV, 27 TROUBLE-SHOOTING GUIDE WARNING: TO AVOID ELECTRICAL SHOCK ALWAYS DISCONNECT THE UNIT FROM THE POWER SOURCE BEFORE ATTEMPTING ANY REPAIR. IF THIS GUIDE DOES NOT CORRECT THE PROBLEM CALL YOUR LOCAL DEALER OR OUR CUSTOMER SERVICE AT 1-800-245-6489. Problem Cause Solution 1. Auger not turning 1. Loose set screw 1. Tighten setscrew on collar 2. Bad gear motor 2. Replace auger motor 3. Foreign matter in auger 3. Remove pellets and object 4. Vacuum sensor (Top Auger) 4. Check exhaust blower 5. Carbon buildup in feed auger tube 5. Remove carbon by scraping 2. Smoke sme

Related Products and Documents (Cooktop):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Black Box Agility Zero-U ACR500DP-T Quick start manual black-box/agility-zero-u-acr500dp-t-6FX.pdf 25 Sep 2023 12
2 Indesit K3C36/G Instructions for installation and use manual indesit/k3c36-g-7J3.pdf 09 Jul 2022 16
3 Icom IC-7400 Service manual icom/ic-7400-T5Q.pdf 15 Dec 2023 92
4 APW Wyott XTRM-1 120V Specification sheet apw-wyott/xtrm-1-120v-SB6.pdf 23 Jul 2022 2 0.42 Mb
5 Audio SC-60A Operation manual audio/sc-60a-VO7.pdf 12 Mar 2024 14
6 McCulloch PM55 Instruction manual mcculloch/pm55-93F.pdf 25 Feb 2023 68

Similar Resources:

  • Wolf

    CG304P/S/LP

    (2 pages)
    MODEL OPTIONSNatural Gas CG304P/SLP Gas CG304P/S/LP30" Gas Cooktop—Professionalwolfappliance.comACCESSORIES• Stainless steel, signature red and black control knobs.• Two-burner wok grate—wok covers one burner only.• High altitude conversion kit for LP gas above 8,600'. For natural gas above 10,250', contact Wolf customer servic …
  • Kenmore

    3248 - Elite 30 in. Gas Cooktop

    (20 pages)
    iNSTALLATiON AND SERVICE MUST BE PERFORMED BY A QUALiFiED iNSTALLER.iMPORTANT: SAVE FOR LOCAL ELECTRICAL iNSPECTOR'S USE.READ AND SAVE THESE iNSTRUCTiONS FOR FUTURE REFERENCE._r_ If the information in this manual is not followed exactly, a fire or explosion may resultcausing property damage, personal injury or death.FOR YOUR SAFETY:-- Do not store or us …
  • Aroma

    Professional AID-513FP

    (19 pages)
    Aroma’s customer service experts are happy to help. Call us toll-free at 1-800-276-6286.Instruction ManualInduction CooktopAID-513FPQuestions or concerns about your Induction Cooktop?Before returning to the store...Answers to many common questions can be found online. Visit www.AromaCo.com/Support. …
  • Falcon

    G9440

    (26 pages)
    1 F900 SERIES User, installation and servicing instructions GAS CHARGRILL G9440, G9460, G9490, G94120 Read these instructions before use T100873DATE PURCHASED: MODEL NUMBER: SERIAL NUMBER: DEALER: SERVICE PROVIDER: REV. 4 Published: 23/08/2016 …
  • Thermador

    Professional PRO-HARMONY PRD30

    (135 pages)
    CARE AND USE MANUALFor Thermador Professional ®PRO-GRAND TM Dual Fuel RangesGUIDE D'UTILISATION ETD'ENTRETIENPour cuisiniere & combustion jumeleeProfessional ®PRO-GRANDTM deThermadorMANUAL DE USO YCUIDADOPara Estufas de Todo Tipo de GasProfessional ®PRO-GRANDTM deThermadorModels/Modeles /Modelos:PRD30PRD36PRD48 …
  • Awanti

    BCT115J1B-IS

    (48 pages)
    1 ELECTRIC COOKTOP COCINA ELECTRICA CUISINIÈRE ÉLECTRIQUE INSTRUCTION MANUAL MANUAL DE INSTRUCCIONES MANUEL D’INSTRUCTIONS Model Modelo Modelé BCT115J1B-IS Actual design / color may vary./ Diseño / color puede variar / Design / Couleur peut varier BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS. Avanti has a …

Comments, Questions and Opinions: