Toshiba ESTIA A09-01P Quick Reference
|
Toshiba ESTIA A09-01P, Quick Reference Guide - Page 11 Pump operation / configuration Change Pump speed, so that water flow is always greater than the minimum flow rate. If water flow is lower than the minimum rate during operation, the unit detects error. Water charging Charge water until the pressure gauge shows 0.2 MPa (2 bar). Hydraulic pressure may drop when the trial run begins. In that case, add water. Air may enter if the charged hydraulic pressure is low. Loosen the purge valve cap by two turns to release air. Loosen the cap of the pressure relief valve to release air. Water may come out of the pressure relief valve. Rele
Quick Reference Guide - Page 15 Input line specifications Description Input Maximum length Emergency stop control Non-voltage 12 m Cylinder thermostat input Non-voltage 12 m Cooling thermostat input Non-voltage 12 m Heating thermostat input Non-voltage 12 m CAUTION Earthing arrangements The Hydro Unit and related equipment must be earthed in ac
Toshiba ESTIA A09-01P, Quick Reference Guide - Page 20 Hydro Unit Remote Control Buttons and Functions 1. TEMP. button: Changes the set temperature for each operation mode (ZONE1/2 hot water) by 1°C step. 10. NIGHT button: Controls the night set back operation. 2. SCHEDULE button: Sets the current time and scheduled weekly operation. 11. AUTO TEMP. button: Switches setting temperature automatically according to outside temperature. (Pressing this button long changes the mode to data setting mode). 3. TIME button: Changes time for current time setting and scheduled week
Quick Reference Guide - Page 4 Installation Examples Space Cooling and Space Heating with Domestic Hot Water When both cooling and heating are used, install a 2-way valve (for cooling) to the pipe to the room for heating only.
Toshiba ESTIA A09-01P, Quick Reference Guide - Page 19 Setting DIP Switches on the Board in the Hydro Unit • Detach the front cover and the electric parts box cover of the Hydro Unit. • Set the DIP switches on the main board. Switch mode SW10 Description Default setting Alternate 1 Internal pump P1 operating mode Continuous operation OFF ON HP synchronized 3 External P2 pump operation Continuous operation OFF ON Interlocked with the internal pump synchronized with P1. Switch mode SW11 Description Default setting Alternate 1 Internal backup heater operation Operate OFF ON Not operate 2
Toshiba ESTIA A09-01P, Quick Reference Guide - Page 22 Display Explanation (cont.) 19: TIMER 21: OPERATION Display Description Display Description Clock: Displays the current time (AM or PM). Lights while internal pump (P1) or external pump (P2) is driven. Displays days of the week (Sunday to Saturday). Lights during backup operation only by the heater. Lights when the NIGHT button is pressed and goes out when the button is pressed again. Lights when the unit enters the data set mode and goes out when the unit exits the data set mode. Lights when night time quiet operation is set. Lights when
Toshiba ESTIA A09-01P, Quick Reference Guide - Page 31 Outdoor Fault Diagnosis You can perform fault diagnosis of the outdoor unit with the LED's on the P.C. board of the outdoor unit in addition to check codes displayed on the wired remote controller of the hydro unit. Use the LED’s and check codes for various checks. Check of the current abnormal status 1. Check that DIP switch SW803 is set to all OFF. 2. Jot down the states of LED800 to LED804. (Display mode 1) 3. Press SW800 for at least one second. The LED status changes to d
Toshiba ESTIA A09-01P, Quick Reference Guide - Page 25 Function Code List (cont.) Function Code Number Function Hydro Unit C Range Default Remote ontroller Outside temperature T1 °C 29 - -15 ~ 0 -10 Outside temperature T2 °C - - 0 0 Outside air temperature T3 °C 2B 0 ~ 15 - 10 Setting temperature A at -20 °C 2C - 20 ~ 55 40 Setting temperature B at T1°C 2D - 20 ~ 55 35 Setting temperature C at T2°C 2E - 20 ~ 55 30 Setting temperature D at T3°C 2F - 20 ~ 55 25 Setting temperature E at +20°C 30 - 20 ~ 55 20 Ratio of Zone 2 in Zone 1 Auto mode (%) 31 - 0 ~ 100 80 Heating Auto Curve Settings Temperatu
Toshiba ESTIA A09-01P, Quick Reference Guide - Page 10 Checking water volume and initial pressure of expansion vessel The expansion vessel of the Hydro Unit has a capacity of 12 litres. The initial pressure of the expansion vessel is 0.1 MPa (1 bar). The suggested initial water charge is 0.2MPa (2 bar). The pressure of the safety valve is 0.3 MPa (3 bar). Verify whether the capacity of the expansion vessel is sufficient using the following expression. If the volume is insufficient, install an appropriate external ex
Toshiba ESTIA A09-01P, Quick Reference Guide - Page 26 Function Code List (cont.) Function Code Number Function Hydro Unit Remote Controller Range Default Remote Controller Indication 24 hour or 12 hour remote control display. 0=24hr; 1=12hr - 05 0 ~ 1 0 0 = Function invalid 1 = Function valid - 09 0 ~ 1 0 Start time (hour) - 0A 0 ~ 23 22 Outdoor Night Time Low Noise Operation End time (hour) - 0B 0 ~ 23 06 Alarm Tone Tone Switching 0: OFF, 1: ON 11 0 ~ 1 1 Pump P2 remote controller Display 0 = Not Shown; 1 = Shown 42 - 0 ~ 1 0 Outdoor Forced Defrost Mode 0 = Forced Defrost OFF; 1 = Forced Defrost ON 46 - 0 ~ 1 0 Optional ON/OF
Toshiba ESTIA A09-01P, Quick Reference Guide - Page 23 ) Setting Hot Water Temperature Range (function code 18 to 1F) ot water. tion code 20 and 21) rature. It ction code 24 and 25) rature when the hot water T WATER BOOST Main setting items (1 • Set the temperature range for heating (zone 1, zone 2), cooling, and h • The upper-limit and lower-limit temperatures of each mode can be set. ) Setting Heat Pump Operation Conditions for Hot Water Supply (func(2 • Set the heat pump start water temperature and heat pump stop wate
Quick Reference Guide - Page 29 Alarm Indications Alarm indication Alarm description and generation/reset conditions E03 Regular communication error between hydro unit and remote controller (system controller) If there is no regular communication from the remote controller for three minutes, the hydro unit regards it as no remote controller. If there is no communication
Toshiba ESTIA A09-01P, Quick Reference Guide - Page 17 2-way valve (for cooling) connection Required Valve Specification: Electrical Specification: 230 V; 50 Hz; <100 mA Return Mechanism: 2-wire spring return. • The Hydro Unit has the facility to connect a 2-way valve to isolate Space Conditioning Units that do not perform cooling, when Cooling Mode is selected. • Connect the 2-way valve in accordance with the diagram (opposite):- 3-way valve (diverter) connection Required Valve Specification:
Toshiba ESTIA A09-01P, Quick Reference Guide - Page 9 Water Piping • Install water pipes according to the regulations of respective countries. • Install water pipes in a freeze-free place. • Make sure that water pipes have sufficient pressure resistance (The setting value of the pressure relief valve is 0.3 MPa). • Do not use zinc plated water pipes. When steel pipes are used, insulate both ends of the pipes. Water Connections • Install a strainer with 30 to 40 meshes (procure locally) at the water inlet of the Hydro Unit. • Install drain cocks (procure locally) for water charge and
Toshiba ESTIA A09-01P, Quick Reference Guide - Page 7 Refrigerant Piping Refrigerant Pipe Lengths and Height The length and height of the refrigeration pipe must be within the following values. Minimum Pipe Length HWS-802H-E : 5 m HWS-1102H-E : 3 m HWS-1402H-E : 3 m Maximum Pipe Length and Height H: Max. ±30 m (above or below) L: Max. 30 m Note The maximum pipe length cannot be increased using additional refrigerant. Refrigeration and Water Cycle Diagrams Hydro Unit Pressure relief Air vent valve Pressure Gauge valve Expansion vessel THO Sensor TWI Sensor TWO Sensor TC Sensor Thermal Protector Hi_P_Switch Pump Water O
Toshiba ESTIA A09-01P, Quick Reference Guide - Page 30 Alarm Indications (cont) A09 Overheat preventive operation malfunction Auto-reset: When operation mode is changed A11 Release preventive operation malfunction This alarm occurs when the Hydro Unit enters the forced- stop zone 10 times. P31 Self-hydro unit is stopped due to alarm of other hydro unit. When alarm occurs in an hydro unit in the group, other hydro units must also be stopped with refrigerant control. When alarm E03, L03 or L07 occurs in the header unit in the group, other hydro units must also be stop
Toshiba ESTIA A09-01P, Quick Reference Guide - Page 6 Hydro Unit – Exploded View 1 : Expansion vessel 2 : Hi pressure switch (4.15 MPa) 3 : Temperature sensor (for Heat pump outlet -TWO) 4 : Pressure sensor 5 : Heat exchanger 6 : Flow switch (13.0 L/min 17.5 L/min) 7 : Temperature sensor (for refrigerant -TC) 8 : Temperature sensor (for water inlet -TWI) 9 : Drain nipple 10 : Water inlet connection 11 : Refrigerant liquid connection 12 : Air relief valve 13 : Pressure relief valve (0.3 MPa (3 bar)) 14 : Thermal prot
Toshiba ESTIA A09-01P, Quick Reference Guide - Page 24 1)Setting 2-Way Valve (for Cooling) Operation (function code 3C) unit only for heating (such as floor 2)Setting 3-Way Valve Operation (function code 54) this setting to invert the logic circuit in case ports 3)Mixing valve types and setting full open of the 2-zone control mixing valve. Set a value that is 1/10 of 4)Setting Heating/Hot Water Switching when Boiler Is Used (function code 3E) the boiler. 5)Setting Heat Pump Operating Time for Hot Water Supply Operation rgization at the beginning of hot 6)Sett
Toshiba HWS-P805XWHM3-E Heat Pump Service manual
HWS-P805XWHM3-E |
Toshiba Carrier MMD-AP0074SPH2UL Heat Pump Installation manual
Carrier MMD-AP0074SPH2UL |
Toshiba HWS-803XWHM3-E Heat Pump Installation manual
HWS-803XWHM3-E |
Toshiba MMU-AP0091H Heat Pump Owner's manual
MMU-AP0091H |
Toshiba HWS-802H-E Heat Pump Installation manual
HWS-802H-E |
Toshiba HWS-802XWHM3-E Heat Pump Owner's manual
HWS-802XWHM3-E |
Toshiba MMU-AP0091H Heat Pump Installation manual
MMU-AP0091H |
Toshiba Carrier MMC-AP0181H2UL Heat Pump Service manual
Carrier MMC-AP0181H2UL |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Danfoss | ECL Comfort 210 | Operating manual | danfoss/ecl-comfort-210-I86.pdf | 02 Feb 2023 | 157 | |
2 | Solar Infra Systems | C50M 2436 | Operating instructions | solar-infra-systems/c50m-2436-7HW.pdf | 02 Sep 2023 | 2 | |
3 | Electrolux | Swissline L EWF 1090 | Instruction booklet | electrolux/swissline-l-ewf-1090-245.pdf | 17 Jul 2023 | 23 | 1.91 Mb |
4 | Clarion | VRX925VD | Installation and wire connection manual | clarion/vrx925vd-9LI.pdf | 01 Oct 2022 | 12 | 0.16 Mb |
5 | Lexmark | C520 | Technical reference | lexmark/c520-41G.pdf | 04 Aug 2023 | 435 | |
6 | Philips | FW12 | Manual | philips/fw12-57F.pdf | 02 Oct 2022 | 15 |
Mammoth
Important: These instructions are for the use ofspecially trained personnel, experienced in the installation of this equipment and related systemcomponents. Some states require licensing ofinstallation and service personnel. Unqualifiedindividuals should not attempt to interpret theseinstructions or install this equipment. Readinstructions carefully before u …
G-141-MHC(20 pages) |
Astralpool
SWIMMING POOL HEAT PUMP User and service manualPOMPE À CHALEUR POUR PISCINE Manuel d’installation et d’utilisationZWEMBAD WARMTEPOMP Gebruiker en service manualBOMBA DE CALOR PARA PISCINA Manual del usuario y de servicioSCHWIMMBAD - WÄRMEPUMPE Benutzer - und WartungshandbuchPISCINA POMPA DI CALORE Istruzioni per l'uso e di servizioBOMBA DE CALOR D …
PRO ELYO INVERBOOST NN(57 pages) |
Dimplex
Order no.: DOK4SVxxDEN EN · FD 9912M Flex AirM Flex Air PlusInstallation and Operating InstructionDomestic Ventilation Unit3VSHCS3VSHCEGlenDimplexDeutschlandDimplex
…
M Flex Air(56 pages) |
Immergas
AUDAX TOP18 - 21 ErPTRKullanım ve uyarılar kılavuzu*1.040572TUR*ESManual de instrucciones y advertencias*1.040572SPA*SKPríručka pokynov a upozornení*1.040572SLO*PTManual de instruções e advertências*1.040572POR*PLInstrukcja montażu i obsługi*1.040572POL*Használati útmutató és gyelmeztetésekHU*1.040572HUN*GRΕγχειρίδιο οδηγ� …
AUDAX TOP 21 ErP(72 pages) |
York
SPLIT-SYSTEM HEAT PUMPS13 SEER – R-410A – Single PhaseMODELS:GHGD18 THRU 60(1.5 THRU 5 NOMINAL TONS)Due to continuous product improvement, specifications are subject to change without notice.Visit us on the web at www.york.comAdditional rating information can be found at www.ahridirectory.orgWARRANTY5-year limited parts warranty.5-year limited compressor …
GHGD18(34 pages) |
Ducane
2hp14 FeaturesB ModelL ModelSplit System Heat Pump14seer•Durablescrollcompressors,withinternalpressure reliefvalvesandinherentthermalprotection•High-qualitycondenser coilwithcoppertubing andenhancedlouvered finformaximumheat transfercapacity•Topdischargedirects� …
2HP14(8 pages) |
Philips Cell Phone Accessories SHB7100/00#GO9BQ1 SHB7100/00: Philips Cell Phone Accessories Owner Documentation SHB7100/00, 107 |
Indesit Washer IWSC 61253#AI3S26 IWSC 61253: Indesit Washer Owner Documentation IWSC 61253, 72 |
La Crosse Weather Station WS-7025ULa Crosse WS-7025U Guide (Doc Type: Weather Station Instruction manual) WS-7025U, 25 |
Unitech Scanner MS336Scanner #935XS8 MS336, 57 |
Braun Coffee Maker NC1000NC1000 (Coffee Maker ePDF Manual, #C2K9VC) NC1000, 20 |
Meicheng Media Converter HD-521P-AHD-521P-A (Media Converter ePDF User Manual, #ZMGM1K) HD-521P-A, 8 |
Rohde & Schwarz Gateway VoxellRohde & Schwarz Gateway Voxell Installation manual Voxell, 51 |
ATIKA Paper Shredder MHA 2800ATIKA Product User Manual: MHA 2800 PDF Original instructions manual - MOGKXH MHA 2800, 140 |
Amana Air Conditioner DRY 093Gxxx series XXXAir Conditioner Operation & user’s manual (Amana DRY 093Gxxx series XXX) DRY 093Gxxx series XXX, 8 |
Vector Vacuum Cleaner VEC248Vacuum Cleaner #AP68F9 VEC248, 8 |
DeWalt Power Screwdriver DW250DeWalt Power Screwdriver Instruction manual (File: dewalt-dw250-instruction-manual-7, Tuesday 14-11-2023) DW250, 7 |
Metz Camera Flash mecablitz 52 AF-1Metz mecablitz 52 AF-1 Camera Flash Operating instruction mecablitz 52 AF-1, 286 |