  • Toshiba TOSVERT VF-AS1 Series, E6581301 F-65 6 6.35 Adjustment parameters 6.35.1 Pulse train output for meters H : Logic output/pulse output selection (OUT1) H : Pulse output function selection H : Selection of number of pulses H : Constant at the time of filtering H : FM output filter • Function Pulse trains can be sent out through the OUT1-NO output terminals. To do so, it is necessary to select a pulse output mode and specify the number of pulses. Set the SW4 to pulse output (PULS). Ex.) When operations freque

  • Toshiba TOSVERT VF-AS1 Series, K-9 E6581301 11 [6] Speed/torque reference gain/bias setup [2/2] Vector control Title Communi cation No. Function Adjustment range Minimum settin g unit ( Panel/Communi cation) Default settin g Write durin g runnin g Speed control Tor que control PM control V/f Reference H 0212 RR/S4 input point 2 setting 0~100% 1/1 100 Enabled ●/●●/●●●7. 3. 1 CXH 0213 RR/S4 input point 2 frequenc y 0.0~HJ Hz 0.1/0.01 *4 Enabled ●/● - ● ● 5. 11 H 0214 RR/S4 input point 1 rate 0~250% (for torque control etc.) 1/0.01 0 Enabl

  • Toshiba TOSVERT VF-AS1 Series, E6581301 L-5 12 12.2 Outside dimensions and mass ■ Outside dimensions and mass Dimensions (mm) Voltage class Applicable motor (kW) Inverter type WHDW1H1W2H2H3H4 Drawing Approx. weight (kg) 0.4 VFAS1-2004PL 3 0.75 VFAS1-2007PL 3 1.5 VFAS1-2015PL 130 230 152 114 220 - - - - A 3 2.2 VFAS1-2022PL 4 3.7/4.0 VFAS1-2037PL 155 260 164 138 249 - - - - B 4 5.5 VFAS1-2055PL 175 295 164 158 283 - - - - C 5.5 7.5 VFAS1-2075PL 210 295 191 190 283 - - - - D 7.5 11 VFAS1-2110PM 14 15 VFAS1-2150PM 230 400 191 210 386 - - - - E 14 18.5 VFAS1-2185PM 21 22 VFAS1-222

  • Toshiba TOSVERT VF-AS1 Series, E6581301 E-22 5 ■ Setting of motor electronic thermal protection level 1 VJT If the capacity of the motor is smaller than the capacity of the inverter, or the rated current of the motor is smaller than the rated current of the inverter, adjust the electronic thermal protection level 1 VJT so that it fits the motor's rated current. VJT×0.6 VJT ×1.0 Output frequency [Hz] Output current reduction factor [%]/[A] 0 30Hz Note:The motor overload starting level is fixed at 30Hz. If necessary, set QNO to ~. (See the following section.) [Example of setting: When the VFAS1-2007PL is running with a 0.4kW motor having 2A rated current] Key operated LED display Operati

  • K-6 E6581301 11 [3] Terminal function selection Vector control Title Communi cation No. Function Adjustment range Minimum settin g unit ( Panel/Communi cation) Default settin g Write durin g runnin g Speed control Tor que control PM control V/f Reference H 0110 Alwa y s ON function selection 1 0~135 *1 1/1 *3 Disabled ●/●●/●●●6. 3. 1

  • Toshiba TOSVERT VF-AS1 Series, K-10 E6581301 11 [7] Operation frequency Vector control Title Communi cation No. Function Adjustment range Minimum settin g unit ( Panel/Communi cation) Default settin g Write durin g runnin g Speed control Tor que control PM control V/f Reference H 0240 Starting frequency setting 0.0~10.0Hz 0.1/0.01 0.1 Enabled ●/● - ●●6. 7. 1 H 0241 Operation start frequency 0.0~HJ Hz 0.1/0.01 0.0 Enabled ●/● - ●●6. 7. 2 H 0242 Operation start frequency hysteresis

  • Toshiba TOSVERT VF-AS1 Series, E6581301 E-29 5 Meter adjustment Adjustment level Fixed output 1 HOUN(COUN)= Fixed output 2 HOUN(COUN)= Fixed output 3 HOUN(COUN)= (a) HJ 54% 40% (b) 185% 100% 74% (c) 150% 81% 60% (d) 250% 135% 100% Note: The 100% value of input/output power is the product of √3×200V (400V) × inverter’s rated current. [Example: Procedure of calibrating the meter connected to the terminal AM to which “output current” is assigned.] Key operated LED display Operation –  Displays the operation frequency. (Perform during operation stopped.) (When standard monitor display selection H= [Output frequency]) CWJ The first basic parameter

  • Toshiba TOSVERT VF-AS1 Series, E6581301 A-24 1 ■ Panel designing taking into consideration the effects of noise The inverter generates high frequency noise. When designing the control panel setup, consideration must be given to that noise. Examples of measures are given below. ・Wire so that the main circuit wires and the control circuit wires are separated. Do not place them in the same conduit, do not run them parallel, and do not bundle them. ・Provide shielding and twisted wire for control circuit wiring. ・Separate the input (power) and output (motor) wires of the main circuit. Do not place them in the same conduit, do not run them parallel, and do not bundle them. ・Ground the inverter

  • Toshiba TOSVERT VF-AS1 Series, E6581301 F-56 6 6.33.4 Output phase failure detection H : Output phase failure detection selection • Function This parameter detects inverter output phase failure. If the inverter detects an open phase failure, the tripping function and the FL relay will be activated. At the same time, the trip information GRJQ will also be displayed. Set H =  to open the motor-inverter connection by switching commercial power operation to inverter operation. H=: No tripping H=: With the power on, the phase failure detection is enabled only at the start of the first operation. The inverter will trip if the inverter detects an open phase

  • Toshiba TOSVERT VF-AS1 Series, E6581301 E-20 5 5.13 Selecting forward and reverse runs (operation panel only) HT : Forward/reverse run selection [Parameter setting] Title Function Adjustment range Default setting HT Forward/reverse run selection : Forward run : Reverse run : Forward run (F/R switching possible) : Reverse run (F/R switching possible)  +Check the direction of rotation on the status monitor. HTH: Forward run HTT: Reverse run ⇒ For monitoring, refer to Section 8.1. +When the F and R terminals are used for switching between forward run and stop from the terminal board, the HT forwar

  • Toshiba TOSVERT VF-AS1 Series, K-25 E6581301 11 [26] Meter output Vector control Title Communi cation No. Function Adjustment range Minimum settin g unit ( Panel/Communi cation) Default settin g Write durin g runnin g Speed control Tor que control PM control V/f Constan t Reference CO 0671 AM terminal meter ad j ustment - 1/1 - Enabled ●/● ●/● ● ● 5. 16 H 0672 MON1 terminal meter selection 0~64 *1 1/1 4 Enabled ●/●●/●●● *2 H 0673 MON1 terminal meter adjustment - 1/1 - Enabled ●/●●/●●● *2 H 0674 MON2 terminal meter selection 0~64 *1 1/1 5 Enabled ●/●●/●●● *2 H 0675 MO

  • E6581301 E-5 5 5.4 Setting parameters by operating method CW : Automatic function setting [Parameter setting] Title Function Adjustment range Default setting CW Automatic function setting :Disabled :Frequency setting by means of voltage :Frequency setting by means of current :Voltage/current switching from external terminal : Frequency setting on operation

  • Toshiba TOSVERT VF-AS1 Series, E6581301 G-5 7 ■ Sink logic/source logic Switching between sink logic and source logic (input/output terminal logic) is possible. ⇒ For details, refer to the Section 2.3.2. 7.2.2 Functions of output terminals (incase of sink logic) Use the above parameters to send various signals from the inverter to external equipment. By setting parameters for the OUT1, OUT2 and FL (FLA, FLB and FLC) terminals on the terminal board, you can use 0~255 functions and functions obtained by combining them. [Control terminal board] ■ How to use Function of OUT1・・・・To be s

  • K-16 E6581301 11 [18] Motor constant [2/2] Vector control Title Communi cation No. Function Adjustment range Minimum settin g unit (Panel/Communi cation) Default settin g Write durin g runnin g Speed control Tor que control PM control V/f Constan t Reference H 0401 Slip frequency gain 0~150% 1/1 70 Enabled ●/● ---6. 22 H 0402 Auto-tuning 2 0:No tuning 1:Self-cool

  • E6581301 E-4 5 1) Increasing torque automatically according to the load Set the automatic torque boost CW= (automatic torque boost+auto-tuning 1) Automatic torque boost CW= detects load current in all speed ranges and automatically adjusts voltage output from inverter. This gives steady torque for stable runs. Note 1: The same characteristic can be

  • Toshiba TOSVERT VF-AS1 Series, E6581301 I-8 9 (2) Do not connect two or more wires to the main circuit earth terminal of the inverter.If necessary, install an additional earth terminal on the noise cut plate on which the inverter is installed and connect another cable to it. (Refer to Fig. 4.) See the Table 5 for earth cable sizes. (3) Install a non-fuse circuit breaker on the input side of the inverter. Noise cut plate Inverter Grounding terminal Install an earth terminal. Fig. 4 9.2 Measures to be taken to satisfy the UL/CSA standards All VF-AS1 series inverters are certified by UL and CSA, and have nameplates with UL and CSA markings. 9.2.1 Caution in inst

  • Toshiba TOSVERT VF-AS1 Series, E6581301 L-6 12 ■ Outline drawing (Installation dimension) (Installation dimension) (Installation dimension) (Installation dimension) Fig. A Fig. B (Installation dimension) (Installation dimension) (Installation dimension) (Installation dimension) Fig. C Fig.D (Installation dimension) (Installation dimension) (Installation dimension) (Installation dimension) Fig. E Fig. F

  • Toshiba TOSVERT VF-AS1 Series, E6581301 F-33 6 [Timing chart (example)] Set frequency Commercial power/inverter switching frequency H MC output for inverter operation Commercial power/inverter switching output 1 (P24-OUT1) MC output for commercial power operation Commercial power/inverter switching output 2 (P24-OUT2) Commercial p ower switchin g si g nal ( S3-CC ) ON Commercial power-side switching waiting time H Inverter-side switching waiting time H Detection time Commercial power switching frequency holding time H ON ON ON Operation standby signal (S

  • Toshiba TOSVERT VF-AS1 Series, E6581301 N-3 14 ■ Replacement of expendable parts The inverter is composed of a large number of electronic parts including semiconductor devices. The following parts deteriorate with the passage of time because of their composition or physical properties. The use of aged or deteriorated parts leads to degradation in the performance or a breakdown of the inverter. To avoid such trouble, the inverter should be checked periodically. Note: Generally, the life of a part depends on the ambient temperature and the conditions of use. The life spans listed below are applicable to parts when used under normal environmental conditions. 1) Cooling fan The fan, w

  • Toshiba TOSVERT VF-AS1 Series, E6581301 F-82 6 6.40 Traverse function H : Traverse selection H : Traverse acceleration time H : Traverse deceleration time H : Traverse step H : Traverse jump step ⇒ For details, refer to Instruction Manual (E6581337) specified in Section 6.41. 6.41 Instruction manuals for optionally available devices and special functions For details, refer to the instruction manual for each optional device or function. No. Description Model number Instruction Manual No. Remarks 1 Light-load high-speed operation function – E6581327 2 PID control operation function – E6581329 3 Torque control operation function – E6581331 4 Cu

  • Toshiba TOSVERT VF-AS1 Series, E6581301 C-5 3 4) Setting the frequency using input voltage (0~10Vdc) [Parameter setting] 5) Setting the frequency using input voltage (0~±10Vdc) The direction can be changed by switching between positive and negative signals. [Parameter setting] Set the “basic parameter frequency setting mode selection 1” parameter HOQF  to  . Note: Set reference frequency priority selection H to  (HOQF/H terminal switching, default setting). Changing the settings of two speed command parameters at a time, refer to Section 6.6. [Example of setting: To set the frequency by applying a current of 4(0)-20mA

  • Toshiba TOSVERT VF-AS1 Series, E6581301 F-72 6 1) To acquire trace data at the occurrence of tripping: H= (Examples of current waveforms output) :Trace data Trace data 1 Trip Failure FL signal Current waveforms output 2) To acquire trace data at the time of triggering: H= Trace data 1 Trigger input Ex.) When using the RR/S4 terminal as the tracing back trigger signal terminal Title Function Adjustment range Example of setting H Input terminal function selection 8 (RR/S4) ~  Note 1: If the inverter trips when no trigger signal is given, trace data is overwritten with tripping data. Note 2: Trace data is o

  • Toshiba TOSVERT VF-AS1 Series, E6581301 C-1 3 3. Operations This section explains the basics of operation of the inverter. Check the following again before starting operation. 1) Are all wires and cables connected correctly? 2) Does the supply voltage agree with the rated input voltage?   Danger Prohibited ・Do not touch inverter terminals when electrical power is applied to the inverter even if the motor is stopped. Touching the inverter terminals while power is connected to it may result in electric shock. ・Do not touch switches when the hands are wet and do not try to clean the inverter with a damp cloth. Such practices may result in electric shock. ・Do not go ne

  • Toshiba TOSVERT VF-AS1 Series, E6581301 E-25 5 5.15 Changing the display unit % to A (ampere)/V (volt) FURW : Current/voltage display mode ■ Example of setting During the operation of the VFAS1-2037PL (rated current 16.6A) at the rated load (100% load), units are displayed as follows: 1) Display in percentage terms 2)Display in amperes/volts [ E E [ Output current: 16.6 A DC voltage: 200V (Converted into A C voltage) DC voltage: 100% Output current: 100%   [Parameter setting] Title Function Adjustment range Default setting FURW Current/voltage unit selection :[%] :[%] → A (ampere)/V (volt)  •Function These paramete

  • Toshiba TOSVERT VF-AS1 Series, E6581301 M-3 13 (Continued) Error code Description Possible causes Remedies GGR EEPROM erro r •A data writing error occurs. •Turn off the inverter, then turn it a g ain. If it does not recover from the error, make a service call. GGR Initial read erro r •Some internal data is corrupted. •Make a service call. GGR Initial read erro r •Some internal data is corrupted. •Make a service call. GH GH Ground fault •A current leaked from an output cable or the motor to ground. •Check the cable and the motor for g round faults. * GRJ Output phase failure •A phase failure occurred in the output line of the main circuit

  • Toshiba TOSVERT VF-AS1 Series, E6581301 F-10 6 ■ Setting of switching terminals The V/f1, V/f2, V/f3 and V/f4 switching function is not yet assigned to any terminal. Therefore, it is necessary to assign them to unused terminals. Ex.) Assigning the V/f switching 1 function to S1 and the V/f switching 2 function to S2. Title Function Adjustment range Example of setting H Input terminal function selection 5 (S1) ~  (V/f switching 1) H Input terminal function selection 6 (S2) ~  (V/f switching 2) S1: V/f switching 1 S2: V/f switching

Related Products and Documents (Inverter):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Sony NWZ-E436FBLU Marketing Specifications (Blue) Specifications sony/nwz-e436fblu-marketing-specifications-blue-T82.pdf 01 Nov 2023 2 0.42 Mb
2 Eiki 7070C How to use manual eiki/7070c-15E.pdf 24 Feb 2023 16
3 RightWay RW355 Operation & user’s manual rightway/rw355-1J9.pdf 30 Mar 2023 120 4.5 Mb
4 Toshiba SDP75SWN Owner's manual toshiba/sdp75swn-X5P.pdf 17 Jul 2022 80 1.12 Mb
5 Epson DFX-9000 Specifications epson/dfx-9000-EYO.pdf 09 Jul 2022 2 0.77 Mb
6 Patton electronics 3054 Operation & user’s manual patton-electronics/3054-495.pdf 19 Dec 2023 9 0.21 Mb

Similar Resources:

  • Sincro

    EK2MCL

    (20 pages)
    SERIE EKManuale di uso e manutenzioneUse and Maintenance manualManuel d’utilisation et de maintenanceBedienungs- und WartungsanleitungenManual de uso y mantenimiento103626REV0108/2018 …
  • Schumacher Electric

    PID-750

    (13 pages)
    00-99-000724/0208Power Inverter PID-750Converts DC Battery Power to AC Household PowerIncludes Battery CablesOWNER’S MANUALCAUTION:Read all Safety Rules and Operating Instructions, and follow them with each use of this product.Schumacher Electric CorporationMount Prospect, IL 60056 U.S.A.Send Warranty Product Repairs to:Customer Service ReturnsP.O. Box …
  • Growatt

    MAX Series

    (6 pages)
    Basic Configuration of the MAX inverter 1. Configuration tool USB-WiFi The small USB-WiFi is small tool for local configuration. Use USB-WiFi module and ShinePhone can do the reading and setting via local WiFi network, no need communication cable anymore. 2. Connection After finished the inverter installation, then can go to the c …
  • Victron energy

    Phoenix MultiPlus 48/3000/35

    (11 pages)
    2020-11-12 10:43 1/11 Victron Energy and Discover AES BatteriesVictron Energy - https://www.victronenergy.com/live/Victron Energy and Discover AES BatteriesThe Discover AES range of Lithium Iron Phosphate batteries is compatible with Victron products invarious systems.These instructions are intended to be used in conjunction with the product manual(s) suppli …
  • Siemens

    MICROMASTER 420

    (44 pages)
    MICROMASTER 420/430/440, Getting Started Guide 10/14 - A5E02779537A3 1 MICROMASTER 420/430/440 English Warnings, Cautions and Notes The following Warnings, Cautions and Notes are provided for your safety and as a means of preventing damage to the product or components in the machines connected. Specific Warnings, Cautions and Notes that apply to particular …
  • SunSynk

    Hybrid Parity Inverter

    (52 pages)
    Web: www.sunsynk.com Email: [email protected] Parity (Super) InverterWITH STORAGE V 1.02USER MANUALGlobal Tech China Ltd, 3 Floor, Wai Yip Industrial Building.171 Wai Yip Street, Kwun Tong, Kowloon, Hong Kong.Tel: +852 2884 4318 Fax: +8522884 4816www.sunsynk.com [email protected] www.globaltechhk.com8.8KW PLUS PARALLEL VERSION …

Comments, Questions and Opinions: