  • E6581160 25 3 (3) Setting the frequency using external signals to terminal board (= or ) ■ Frequency setting 1) Setting the frequency using external potentiometer : Setting frequency using potentiometer ★Potentiometer Setting frequency using the potentiometer (1k-10kΩ, 1/4W) Frequency 60Hz 0 MIN MAX * The input terminal VIA can be used in th

  • Toshiba TOSVERT VF-S11, E6581160 13 2 2. Connection 2.1 Standard connections 2.1.1 Standard connection diagram 1 This diagram shows a standard wiring of the main circuit. MCCB *1 R/L1 S/L2 T/L3 U/T1 V/T2 W/T3 I M FLA FLB FLC RY RC PLC Motor F R RES S1 S2 S3 CC P24 OUT NO CC FM PLC CC VIA VIB PP + + - - P0 PA/+ PB PC/- Meter Voltage signal: 0-10V (Current signal: 4-20mA) External potentiometer (1k~10kΩ) (or input voltage signal across VIB-CC terminals: 0-10V) Control circuit Operation panel Protective function activation output Ry VF-S11 Frequency meter

  • Toshiba TOSVERT VF-S11, E6581160 21 2 ★ The examples of connection are shown below when VIA and VIB are used as contact input terminals. ■ Logic switching/Voltage-current output switching (slide switch) (1) Logic switching Use SW1 to switch between logics. Switch between logics before wiring to the inverter and without supplying power. If switching between sink, source and PLC is done when power is turned on after switching or when the inverter is supplied with power, the inverter might become damaged. Confirm it before supplying power. (2) Voltage-current output switching Use the FM swit

  • E6581160 54 7 7. Table of parameters and data For details on the function of each parameter, refer to the full version of English manual (E6581158). 7.1 User parameters Title Function Unit Minimum setting unit Panel/Comm unication Adjustment range Default setting User setting Reference E6581158  Operation frequency of operation panel Hz 0.1/0.01 - 0

  • Toshiba TOSVERT VF-S11, E6581160 72 7 ■ Table of input terminal functions 3 Function No. Code Function Action 54 STN Coast stop (gate off) ON: Coast stop (gate off) 55 RESN Inversion of RES ON: Acceptance of reset command OFF→ ON: Trip reset 56 F+ST Combination of forward run and standby ON: Simultaneous input from F and ST 57 R+ST Combination of reverse run and standby ON: Simultaneous input from R and ST 58 AD3 Acceleration/deceleration 3 selection ON: Acceleration/deceleration 3 OFF: Acceleration/deceleration 1 or 2 59 F+AD3 Combinati

  • Toshiba TOSVERT VF-S11, E6581160 9 ⎯⎯ Contents ⎯⎯ I Safety precautions.........................................................................................................................................................1 1. Read first ....................................................................................................................................................................... 10 1.1 Check product purchase....................................................................................................................................10 1.2

  • Toshiba TOSVERT VF-S11, E6581160 56 7 Title Communication No. Function Unit Minimum setting unit Panel/Commun ication Adjustment range Default setting User setting Reference E6581158  0015 V/F control mode selection - - 0: V/F constant 1: Variable torque 2: Automatic torque boost control 3: Vector control 4: Energy-saving 5: Dynamic energy-saving (for fans and pumps) 6: PM motor control 2 5.11  0016 Torque boost value 1 % 0.1/0.1 0.0-30.0 * 1 5.12  0600 Motor electronic- thermal protection level 1 % (A) 1/1 10-100 100 5.13 6.19.1

  • E6581160 74 7 ■ Table of output terminal functions 2 Function No. Code Function Action 22 PAL Pre-alarm One of the following is turned on: ON POL, POHR, POT, MOFF, UC, OT, LL stop, COT, and momentary power failure slowdown stop. or ,, issues an alarm All the following are turned off: OFF POL, POHR, POT, MOFF, UC, OT, LL stop, COT, and moment

  • Toshiba TOSVERT VF-S11, E6581160 19 2 Terminal symbol Input/output Function Electrical specifications Inverter internal circuits RY RC Output Multifunction programmable relay contact output. Standard default settings detect and output low-speed signal output frequencies. Multifunction output terminals to which two different functions can be assigned. 250Vac-1A (cosφ=1) : at resistance load 30Vdc-0.5A 250Vac-0.5A (cosφ=0.4) ■ SINK (Negative) logic/SOURCE (Positive) logic (When the inverter's internal power supply is used) Current flowing out turns c

  • E6581160 42 5 5.1.2 Display of detailed information on a past trip Details on a past trip (of trips 1 to 4) can be displayed, as shown in the table below, by pressing the key when the trip record is selected in the status monitor mode. Unlike the "Display of detailed trip information at the occurrence of a trip" in 5.2.2, details on a past trip can

  • Toshiba TOSVERT VF-S11, E6581160 4 I Warning Instruction • Electrical installation work must be done by a qualified expert. Connection of input power by someone who does not have that expert knowledge may result in fire or electric shock. • Connect output terminals (motor side) correctly. If the phase sequence is incorrect, the motor will operate in reverse and that may result in injury. • Wiring must be done after installation. If wiring is done prior to installation that may result in injury or electric shock • The following steps must be performed before wiring. (1) Turn off all input power. (2) Wait

  • Toshiba TOSVERT VF-S11, E6581160 24 3 3.1.2 How to set the frequency [Example of a  setting procedure] Key operated LED display Operation  Displays the operation frequency (operation stopped). (When standard monitor display selection = [Operation frequency])  Displays the first basic parameter [History ()].  Press either the key or key to select “”.  Press ENTER key to display the parameter setting. (Default setting: ).  Change the parameter to  (Operation panel) by pressing the key. �

  • Toshiba TOSVERT VF-S11, E6581160 32 4 4.2 How to set parameters The standard default parameters are programmed before the unit is shipped from the factory. Parameters can be divided into 4 major categories. Select the parameter to be changed or to be searched and retrieved. Basic parameters : The basic parameters that must be programmed before the first use. (See 4.2.1) Extended parameters : The parameters for detailed and special setting. (See 4.2.2) User parameters (automatic edit function) : Indicates pa

  • Toshiba TOSVERT VF-S11, E6581160 22 3 3. Operations 3.1 Simplified Operation of the VF-S11 The procedures for setting operation frequency and the methods of operation can be selected from the following. Start / Stop : (1) Start and stop using the operation panel keys (2) Run and stop using external signals to terminal board Setting the frequency : (1) Setting using the potentiometer on the inverter main unit (2) Setting using the operation panel (3) Setting using external signals to the termina

  • Toshiba TOSVERT VF-S11, E6581160 38 4 4.2.6 Returning all parameters to standard default setting Setting the standard default setting parameter =, all parameters can be returned to the those factory default settings. Note: For more details on the standard default setting parameter , see 5.6. Notes on operation • We recommend that before this operation you write down on paper the values of those parameters, because when setting =, all parameters with changed values will be returned to standard factory default setting. • Note that , , , f470-f473,  and  will no

  • Toshiba TOSVERT VF-S11, Simplified manualIndustrial Inverter TOSVERT VF-S11 2 1 3 4 5 6 7 8 9 9 10 11 12 13 14 15 16 E6581160 Connection I Safety precautions Contents Read first Operations Basic VF-S11 operations Monitoring the operation status Measures to satisfy the standards Table of parameters and data Specifications Before making a service call Measures to satisfy the standards Peripheral devices Table of parameters and data Specifications Before making a service call - Trip information and remedies Inspection and maintenance Warranty Disposal of the inverter NOTICE 1.Make sure that this instruction manual is delivered to the

  • Toshiba TOSVERT VF-S11, E6581160 7 I  Disposal Caution Instruction • If you dispose of the inverter, have it done by a specialist in industry waste disposal(*). If you dispose of the inverter in an inappropriate way, this can result in explosion of capacitor or produce noxious gases, resulting in injury. (*) Persons who specialize in the processing of waste and known as "industrial waste product collectors and transporters" or "industrial waste disposal persons". If the collection, transport and disposal of industrial waste is done by someone who is not licensed for that job, it is a punishable violation of the law

  • Toshiba TOSVERT VF-S11, E6581160 12 1 1.2 Contents of the product Explanation of the name plate label. Always shut power off first then check the ratings label of inverter held in a cabinet. Type Form VFS11S - 2007PLE- WN -A22 Model name TOSVERT VF-S11series Number of power phases S: sin g le- p hase None: three- p hase Applicable motor capacity 002 : 0.2kW 004 : 0.4kW 005 : 0.55kW 007 : 0.75kW 015 : 1.5kW 022 : 2.2kW 037 : 3.7kW 055 : 5.5kW 075 : 7.5kW 110 : 11kW 150 : 15kW Additional functions I

  • Toshiba TOSVERT VF-S11, E6581160 5 I ■ Operations Warning Prohibited • Do not touch inverter terminals when electrical power is going to the inverter even if the motor is stopped. Touching the inverter terminals while power is connected to it may result in electric shock. • Do not touch switches when the hands are wet and do not try to clean the inverter with a damp cloth. Such practices may result in electric shock. • Do not go near the motor in alarm-stop status when the retry function

  • Toshiba TOSVERT VF-S11, E6581160 39 5 5. Monitoring the operation status Refer to 4.1 about flow of monitor. 5.1 Status monitor mode 5.1.1 Status monitor under normal conditions In this mode, you can monitor the operation status of the inverter. To display the operation status during normal operation: Press the key twice. Setting procedure (eg. operation at 60Hz) Item displayed Key operated LED display Communic ation No. Description . The operation frequency is displayed (Operation at 60Hz). (When standard monitor display selection  is set at 0 [operation frequency]) Parameter setting mode  The first ba

  • Toshiba TOSVERT VF-S11, E6581160 66 7 • Operation panel parameters Title Communication No. Function Unit Minimum setting unit Panel/Commun ication Adjustment range Default setting User setting Reference E6581158  0700 Prohibition of change of parameter settings - - 0: Permitted 1: Prohibited 0 6.21.1  0701 Unit selection - - 0: % 1: A (ampere)/V (volt) 0 6.21.2  0702 Free unit selection Times 0.01/0.01 0.00: Free unit display disabled (display of frequency) 0.01-200.0 0.00  0705 Inclination characteristic of free unit display - - 0: Negative inclination (downward slope) 1: Positive inclination (upward slope

  • Toshiba TOSVERT VF-S11, E6581160 34 4 4.2.2 How to set extended parameters The VF-S11 has extended parameters to allow you to make full use of its functions. All extended parameters are expressed with  and three digits. Basic parameters  ~ ENT Press the MODE key once and use the VW key to select  from the basic parameters. Press the V key or the W key to change the set value. Pressing the ENTER key allows the reading of parameter setting. MODE [Steps in key entry for extended parameters] : switches to the setting monitor mode.(Displays ) : Selects the extended parameter whose setting needs to be changed. : Changes the pa

  • Toshiba TOSVERT VF-S11, E6581160 82 9 9. Before making a service call - Trip information and remedies 9.1 Trip causes/warnings and remedies When a problem arises, diagnose it in accordance with the following table. If it is found that replacement of parts is required or the problem cannot be solved by any remedy described in the table, contact your Toshiba dealer. [Trip information] Error code Failure code Problem Possible causes Remedies   0001 0025 Overcurrent during acceleration Overcurrent flowing in element during acceleration • The acceleration time  is too short. • The V/F sett

  • Toshiba TOSVERT VF-S11, E6581160 6 I  When sequence for restart after a momentary failure is selected (inverter) Caution Instruction • Stand clear of motors and mechanical equipment. If the motor stops due to a momentary power failure, the equipment will start suddenly after power recovers. This could result in unexpected injury. • Attach warnings about sudden restart after a momentary power failure on inverters, motors and equipment for prevention of accidents in advance.  When retry function is s

Related Products and Documents (Inverter):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Roland Boss NS-50 Owner's manual roland/boss-ns-50-7Y2.pdf 17 May 2023 8 0.23 Mb
2 Radio Shack 40-1426 Owner's manual radio-shack/40-1426-119.pdf 27 Jan 2023 2 0.06 Mb
3 KitchenAid YKGRT507 Use and care manual kitchenaid/ykgrt507-7ZI.pdf 29 Mar 2024 71
4 Moxa Technologies NPort IA 5250 series Operation & user’s manual moxa-technologies/nport-ia-5250-series-834.pdf 22 Sep 2022 108
5 Crestron CNXENET+ Operations & installation manual crestron/cnxenet-ZVV.pdf 26 May 2023 12 0.58 Mb
6 Intel D915GVWB Specification update intel/d915gvwb-322.pdf 15 Sep 2023 14

Similar Resources:

  • Agilent Technologies

    33120A

    (146 pages)
    Service GuidePublication Number 33120-90017 (order as 33120-90104 manual set) Edition 6, March 2002© Copyright Agilent Technologies, Inc. 1994-2002For Safety information, Warranties, and Regulatory information,see the last page in this manual.Agilent 33120A15 MHz Function / Arbitrary Waveform Generator Cover Page for Web Version ONLY (Service Guide) …
  • Toshiba

    DEV002Z

    (20 pages)
    E6581295⑥ TOSVERT VF-AS1/PS1 Option Instruction Manual DEV002Z-1 * The data given in this manual are subject to change without notice. © Toshiba Schneider Inverter Corporation 2005 All rights reserved. NOTICE 1. Make sure that this instruction manual is delivered to the end user of the DeviceNe …
  • TECO-Westinghouse

    A510

    (2 pages)
    OUT of the Box Startup – OverviewThis document is intended as a quick start guide to get familiarity with keypad navigation, changing parameters, and setting the A510 drive up for external start/stop and external potentiometer signal. Please note this document is not a substitute for the A510 User Manual and it is important that you reference the A510 user …
  • Kisae

    MW 1210

    (12 pages)
    Modified Sinewave Power Inverter 1000/1500 MW 1210, MW1215 True Sinewave Power Inverter 1000/2000 SW 1210, SW 1220 Owner’s Manual  Modified Sinewave Series True Sinewave Series …
  • Siemens

    880

    (4 pages)
    RGB ELEKTRONIKA AGACIAK CIACIEKSPÓŁKA JAWNA Jana Dlugosza 2-6 Street51-162 WrocławPoland [email protected] +48 71 325 15 05www.rgbautomatyka.plwww.rgbelektronika.plDATASHEETwww.rgbautomatyka.plwww.rgbelektronika.pl OTHER SYMBOLS:6FX1120-4BB026FX11204BB02, 6FX1120 4BB02, 6FX1120-4BB02SIEMENS …
  • Hosola

    1000TL

    (28 pages)
    Hosola Smart SeriesGrid tied InverterOperation GuideHosola New Energy Co., Ltd.Hosola-SM-V1-ENHosola New Energy Co., Ltd.Add: NO.328 Xinghu Road,Suzhou Industrial Park,China,215123Tel:+86 512 6281 5763Fax:+86 512 6281 5763-1888E-mail:[email protected] rights reserved by Hosola …

Comments, Questions and Opinions: