  • Toshiba DEV002Z, E6581295⑥ TOSVERT VF-AS1/PS1 Option Instruction Manual DEV002Z-1 * The data given in this manual are subject to change without notice. © Toshiba Schneider Inverter Corporation 2005 All rights reserved. NOTICE 1. Make sure that this instruction manual is delivered to the end user of the DeviceNet option for the VF-AS1/PS1. 2. Read this manual before installing or operating the DeviceNet option for the VF-AS1/PS1. And keep it in a safe place

  • E6581295⑥ - 1 - Safety precautions On the inverter and in its instruction manual, important information is contained for preventing injuries to users and damages to assets and for proper use of the device. Read the instruction manual attached to VF-AS1/PS1 along with this instruction manual for completely understanding the safety precautions and adhere to the c

  • Toshiba DEV002Z, E6581295⑥ - 2 - ■ General Operation Danger Disassembly prohibited ▼ Never disassemble, modify or repair. Doing so could result in electric shock, fire and injury. For repairs, call your sales agency. Prohibited ▼ Do not attach this option to any inverter other than the VF-AS1/PS1. Doing so could result in electric shock or fire. ▼ When the inverter is energized, never detach the this option from the VF-AS1/PS1. Doing so could result in electric shock. ▼ Don't place or insert any kind of object into the DEV002Z (electrical wire cuttings, rods,

  • Toshiba DEV002Z, E6581295⑥ - 3 - ■ Wiring Danger Mandatory ▼ Shut off power when installing and wiring this option. Wait at least 15 minutes and check to make sure that the charge lamp (VF-AS1/PS1) is no longer lit. ▼ Tighten the screws on the terminal block to the specified torque (Refer to Section 4.1). If the screws are not tightened to the specified torque, it may lead to fire. ▼ Electrical construction work must be done by a qualified expert. Installation or connection of input power by someone who does not have that expert knowledge may result in fire or electric shock. ■ Operations Danger P

  • Toshiba DEV002Z, E6581295⑥ - 4 - Introduction Thank you for purchasing a “VF-AS1/PS1 DeviceNet Option (DEV002Z),” for TOSVERT VF-AS1/PS1 inverter. Installing this option in the VF-AS1/PS1 and using it together, data communication can be made with a host computer or other device via DeviceNet. Please read the entire manual carefully before attempting to control your inverter via DeviceNet connection. Besides this instruction manual, the “DEV002Z Function Manual” is required to develop software communicating with VF-AS1/PS1. In such a case, please get in touch with our branch offices or sales offices. (“DEV002Z Function Manual”: E6581281). This manual is also aimed at the operator

  • Toshiba DEV002Z, E6581295⑥ - 5 - Contents 1. OVERVIEW ..............................................................................................................................................6 2. EXTERIOR FEATURES...........................................................................................................................7 2.1. DeviceNet connector.......................................................................................................................7 2.2. DeviceNet indicator .....................................................................................................................

  • E6581295⑥ - 6 - 1. Overview The DEV002Z interface allows the VF-AS1/PS1 inverter to be connected into a DeviceNet network. DeviceNet supports a maximum of 64 nodes, allowing for the Master unit and the configuration tool a maximum of 62 devices can be connected to the network. Master (PLC, etc.) VF-AS1/PS1 VF-AS1/PS1 VF-AS1/PS1

  • Toshiba DEV002Z, E6581295⑥ - 7 - 2. Exterior features The external view of this option and the name of each part are shown below: Danger Prohibited ▼ Do not change the switch setting when the power is on. It could lead to electric shocks, or the option might breaks down or get damaged. 2.1. DeviceNet connector Used to connect DeviceNet network cables. The terminal is a plug-type and the signal of each terminal is as follows. Size of connectable wire: 0.3 to 1.5mm 2

  • Toshiba DEV002Z, E6581295⑥ - 8 - 2.2. DeviceNet indicator The DEV002Z option has a two-color (red and green) LED as a means of indicating the MNS (module/network status), which works basically in accordance with DeviceNet specifications. LED Status Item displayed Off Not Powered/Not On–line Device is not on-line. - The DEV002Z has not completed the Dup_MAC_ID test yet. - The DEV002Z may not be powered. Lights green. Device Operational AND On–line, Connected The DEV002Z is operating in a

  • Toshiba DEV002Z, E6581295⑥ - 9 - 3. Installing the DEV002Z Install the DeviceNet option to VF-AS1/PS1 as follows: * When this option is used together with the IO card option, attach this option to the front panel side. (1) Turn off input power of VF-AS1/PS1 and wait for at least 15 minutes and then check that the CHARGE lamp on VF-AS1/PS1 is no longer lit. (2) Securing the option to the inverter a) Insert a flat-blade screwdriver in each of the two holes at the upper part of the front panel, release the panel mounting tab

  • Toshiba DEV002Z, E6581295⑥ - 10 - 4. Connecting to the network 4.1. Installation method (1) Attach DeviceNet cable to DeviceNet connector. (Refer to Section 2.1). (Be careful not to short-circuit adjacent terminals on DeviceNet connector). <Recommended cable> Thin branch cables: DeviceNet-specific thin cable. <Tightening torque> 0.5 - 0.6 N·m Recommended screwdriver: Small flat-blade screwdriver (blade thickness: 0.6mm, blade length: 3.5mm or less) (2) Please set the terminating resistance if needed. <Terminating resistance specification> 1/4 W - 121 ohm, 1% Metal Film (3) Using t

  • Toshiba DEV002Z, E6581295⑥ - 11 - 4.2. Network Grounding Please note the following points regarding the grounding of a DeviceNet network. - Do not connect the G/E terminal to a power ground or any other potential noise-producing ground connection (such as a drive’s “E” terminal). Connect to a close, clean ground to provide RF termination of the DeviceNet cable. - Do not make connections to unstable grounds (paint-coated screw heads, grounds that are subjected to inductive noise, etc.) To prevent ground loops, the DeviceNet network should be earth grounded in only one location. No significant current flow between V- and earth ground may occur via any

  • E6581295⑥ - 12 - 4.3. Setting a MAC ID number and a network baud rate Configure MAC ID and network baud rate by the dip switch on the DeviceNet option. • MAC ID configuration The MAC ID must be unique and not match any other device on the network. 3 4 5 6 7 8 3 4 5 6 7 8 SW ID MAC ID SW ID MAC ID 0 OFF OFF OFF OFF OFF OFF 32 ON OFF OFF OFF OFF OFF 1

  • Toshiba DEV002Z, E6581295⑥ - 13 - 5. Communications-related parameters On the network, the VF-AS1/PS1 (including the DEV002Z) serves as a slave device. Using the parameters listed below, set the slave device on the network and its mode of operation. These settings can also be made by the use of configuration tools and the EDS file. The EDS file can be downloaded from the following web site. http://www.inverter.co.jp/product/inv/vfas1/dev/index_i.htm Parameter Function Adjustment range Default setting f830* Communication option setting 1 Assembly Object 0: Instance 20/70 1: Instance 21/71 2: Instance 100/150 3: Instance 101/151 4: Instance 102/152 0 f851 Inve

  • E6581295⑥ - 14 - 5.1. f851: Communication Loss Action Setting (Network breaks) This parameter sets up the VF-AS1/PS1 response to a loss of communications with the DeviceNet network. 0: Stop and Communication release The inverter decelerates the motor to a stop and gives an  alarm (the leftmost LED  flashes). Commands entered through the network are canceled, and the command

  • Toshiba DEV002Z, E6581295⑥ - 15 - 5.3. f830: Assembly Object Setting The Input/Output Instance of DEV002Z is set up by this parameter. The DEV002Z supports both the standard DeviceNet AC Drive profile Instances 20/70, 21/71 and user defined Instances 100/150, 101/151, 102/152. * For an explanation of f830 = 0 (Instance 20/70), 1 (Instance 21/71), 3 (Instance 101/151) and 4 (Instance 102/152), refer to the function manual (E6581281). f830=2 (Instance 100/150) * Drive Reference Speed command value A frequency should be specified in

  • Toshiba DEV002Z, E6581295⑥ - 16 - Data composition of output instance 100 Byte bit Specifications 0 1 Supplement 0 0 Preset speed #1* 1 0 1 Preset speed #2* 1 0 2 Preset speed #3* 1 0 3 Preset speed #4* 1 Preset speed OFF: 0000, Preset speed #1-#15: 0001 to 1111 A combination of 4 different bits is used to select a preset speed from among preset speed operation OFF and preset speed #1 to #15. 0 4 Motor #1/#2 (THR2 selection) Motor #1 (THR1) Motor #2 (THR2) Used to select a motor electronic-thermal protection level. 0: Protection level #1 (thr) 1: Protection level #2 (f173) 0 5 PI control Normal operation PI control off - 0 6 Ac

  • Toshiba DEV002Z, E6581295⑥ - 17 - Data composition of output instance 150 Byte bit Specifications 0 1 Supplement 0 0 Fault FL No output Output - 0 1 Fault No trip Tripped The rtry status and the trip retention status are also regarded as tripped statuses. 0 2 Alarm No alarm Alarm issued - 0 3 (Reserved) - - - 0 4 Motor #1/#2 (THR2 selection) Motor #1 (THR1) Motor #2 (THR2) Indicates the motor electronic-thermal protection level selected. 0: Protection level #1 (thr) 1:

  • Toshiba DEV002Z, E6581295⑥ - 18 - 6. DeviceNet Local/Remote Operation The example below shows how to configure the VF-AS1/PS1 for local / remote operation. <Terminal function> F terminal ............ Operating command R terminal............ DeviceNet/Local (Terminal in this example) switching RR/S4 terminal.... Operation frequency command <Wiring> VF-AS1/PS1 F R CC PP RR/S4 Variable resistor for adjustment 1 - 10k ohm DeviceNet/Local Switch Operation command SINK SW1 SOURCE CCA <Parameter setting> cmod (Command mode selection) = 0 (Terminal board) fmod (Frequency setting mode selection 1) = 2 (RR/S4) f

  • Toshiba DEV002Z, E6581295⑥ - 19 - 7. Specifications Item Specifications Model number DEV002Z DeviceNet Device type: AC drive Connector: Plug type Indicator: MNS (Module / Network status) MAC ID setup: DIP switch Baud-rate setup: DIP switch Baud-rate: 125kbps, 250kbps, 500kbps Use environments Indoors, an altitude of 3,000m or less, where the product will not be exposed to direct sunlight, corrosive or explosive gases, vapor, coarse particulates including dust, and where there is no grinding fluid or grinding oil nearby Ambient temperature -10 to +60°C Storage temperature -25 to +65°C Relative humidity 20 to 93% (no condensation and absence of vapor) Vibrati

Related Products and Documents (Network Card):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Heat & Glo XLR-PLUS-PB-AU Owner's manual heat-glo/xlr-plus-pb-au-122.pdf 09 Sep 2023 77 12.18 Mb
2 Vortex ZC24L Owner's manual & installation instructions vortex/zc24l-VCF.pdf 31 Aug 2022 20
3 Heritage Belle Operation & user’s manual heritage/belle-666.pdf 01 Aug 2023 6 2.79 Mb
4 Optoma EP761 Datasheet optoma/ep761-MB9.pdf 04 Mar 2024 1
5 Crestron TPMC-10-MS Datasheet crestron/tpmc-10-ms-156.pdf 29 Mar 2023 2 0.15 Mb
6 Planet Technology UE-9500 Operation & user’s manual planet-technology/ue-9500-11K.pdf 14 Feb 2024 7

Similar Resources:

  • Cisco

    12000 - Series Chassis Modular Expansion Base

    (62 pages)
    CHAPTER2-1Cisco 12000 Series Router SIP and SPA Hardware Installation GuideRelease 12.0(33)S, OL-8831-01, Rev. G92Overview: Cisco 12000 Series Router Shared Port AdaptersRelease 12.0(33)S, OL-8831-01, Rev. G9This chapter describes the shared port adapters (SPAs) that are supported on the Cisco 12000 Series Router and contains the following sections:• SPA S …
  • Laserworld

    ShowNET

    (24 pages)
    Manual / BedienungsanleitungLaserworld ShowNETNetwork InterfacePlease read this manual carefully prior to product operation!Bitte lesen Sie diese Bedienungsanleitung vor Inbetriebnahme des Produkts!11/2015 EnglishDeutsch …
  • Renesas

    M16C FAMILY

    (103 pages)
    REJ10J0143-0401Z USB Flash WriterUser's ManualRENESAS SINGLE-CHIP MICROCOMPUTER M16C FAMILY / 740 FAMILY Rev.4.01 Renesas Solutions Corp.Revision date: Dec 24, 2004 www.renesas.com …
  • Aiphone

    IX SERIES

    (11 pages)
    For more details about the features and information above, please contact Technical Support.Aiphone Corporation | www.aiphone.com | [email protected] | (800) 692-0200IX SERIESIP Network-Compatible SystemIXW-MA Programming GuideThis is an abbreviated programming manual addressing basic IXW-MA program settings using IX Support Tool. A complete set of instruc …
  • Panasonic

    MA3X786 (MA786)

    (3 pages)
    Schottky Barrier Diodes (SBD)1Publication date: April 2004 SKH00085CEDMA3X786 (MA786)Silicon epitaxial planar typeFor super high speed switchingFor small current rectification■ Features• Forward current (Average) IF(AV) = 100 mA rectification ispossible• Optimum for high frequency rectification because of its shortreverse recovery time trr• Low forwa …
  • Furman

    PB48

    (12 pages)
     …

Comments, Questions and Opinions: