  • Toshiba H9, H9 ASD Installation and Operation Manual 139 Synchronized Acceleration Time Program ⇒ Protection ⇒ Undervoltage/Ridethrough In the event that the Ridethrough function activates in a multiple-motor application it will be necessary to manage the accelerating motors synchronously as not to damage the product being processed (e.g., wire spools, bobbin winder for textile machines, etc.). This parameter is used to minimize the product breakage during a momentary power outage. This function orchestrates the acceleration of multiple machines simultaneously or makes them reach their respective command freq

  • Toshiba H9, 210 H9 ASD Installation and Operation Manual Communications Option (DeviceNet/Profibus) Setting 2 Program ⇒ Communications ⇒ Communication Settings While using the DeviceNet/Profibus communications protocol, parameters F831 – F836 allow the user to select the ASD memory location that holds the Command/Frequency/Monitoring instructions to be applied to the ASD for Communications Option Settings 2 – 7, respectively. See the DeviceNet Option Instruction Manual (P/N 58683) for more information on this parameter. Settings: 0 — Disabled 1 — FA06 (ALCAN Command 1) 2 — FA23 (ALCAN Command 2) 3 — FA07 (ALCAN Frequency

  • Toshiba H9, H9 ASD Installation and Operation Manual 87 Input Terminal Priority Program ⇒ Terminal ⇒ Input Special Functions This parameter is used to allow the Jog and DC Injection Braking input signals to control the ASD when received via the Terminal Board even though the system is in the Local mode. With this parameter enabled, a Jog command or a DC Injection Braking command received from the Terminal Board will receive priority over commands from the EOI. See F260 for more information on using the Jog function. See F250 – F252 for more information on DC Injection Braking. Settings: 0 — Disabled 1 — Enabled Direct Access N

  • Toshiba H9, 52 H9 ASD Installation and Operation Manual UTILITIES Version (read-only) CPU Code Revision N/A MC Version MC Revision Main Board EEPROM Version Main Monitor Selections Monitor #1 Monitor #2 View Trace Data View Trace Data PROTECTION Protection Abnormal Speed Settings Abnormal Speed Detection Time F622 Over-speed Detection Frequency Upper Band F623 Over-speed Detection Frequency Lower Band F624 Base Frequency Voltage Supply Voltage Correction F307 DC Injection Braking DC Injection Braking Start Frequency F250 DC Injection Braking Current F251 DC Injection Braking Time F252 Forward/Reverse DC Injection Braking Priority F253 Motor Shaft Stationary Control F254 Dynamic Braking Dynamic B

  • Toshiba H9, 232 H9 ASD Installation and Operation Manual Virtual Input Terminal 1 Selection Program ⇒ Terminal ⇒ Input Terminals This parameter is used to set the functionality of the Virtual Input Terminal 1. As a virtual terminal, it exists only in memory and is considered to always be in its True (connected to CC) state. It is often practical to assign a function to this terminal that the user desires to be maintained regardless of external conditions or operations. This parameter sets the programmable Virtual Input Terminal 1 terminal to one of the functions that are listed in Table 5 on pg

  • Toshiba H9, H9 ASD Installation and Operation Manual 197 FM Bias Adjustment Program ⇒ Terminal ⇒ Analog Output Terminals This parameter setting is used to ensure that a zero-level input signal produces a zero-level output at the FM terminal. Set the function of F005 to zero and then set this parameter to zero for proper operation. See F005 for more information on this setting. Direct Access Number — F683 Parameter Type — Numerical Factory Default — 0.0 Changeable During Run — Ye s Minimum — -10.0 Maximum — +100.0 Units — % AM Output Gradient Characteristic

  • 156 H9 ASD Installation and Operation Manual Reverse Speed Limit Input Program ⇒ To rq ue ⇒ Torque Control This parameter Enables/Disables the Reverse Speed Limit Input control function. When enabled and operating in the Torque Control mode, the reverse speed limit is controlled by the terminal selected here. If Setting is selected, the value set at F428 is used as the Reverse Sp

  • H9 ASD Installation and Operation Manual 173 Pattern Group 1 Selection 2 Program ⇒ Pattern Run ⇒ Speeds This parameter allows the user to select 1 of 15 configured Preset Speeds as the number 2 Selection to be included in Pattern Group 1. Skip may be selected to ignore this Selection. Setting 0 — Skip 1 – 15 Preset Speed Number See F523 for more information on this parameter. Direc

  • Toshiba H9, 174 H9 ASD Installation and Operation Manual Pattern Group 1 Selection 6 Program ⇒ Pattern Run ⇒ Speeds This parameter allows the user to select 1 of 15 configured Preset Speeds as the number 6 Selection to be included in Pattern Group 1. Skip may be selected to ignore this Selection. Setting 0 — Skip 1 – 15 Preset Speed Number See F523 for more information on this parameter. Direct Access Number — F528 Parameter Type — Selection List Factory Default — Skip Changeable During Run — No Pattern Group 1

  • Toshiba H9, H9 ASD Installation and Operation Manual 135 Retry Selection Program ⇒ Protection ⇒ Retry/Restart After a trip has occurred, this parameter sets the number of times that an automatic system restart is attempted for a qualified trip. The trip conditions listed below will not initiate the automatic Retry/Restart function: • Input Phase Loss (Input Phase Failure) • Output Phase Loss (Output Phase Failure) • Output Current Protection Fault • Output Current Detector error • Load side overcurrent at start • Earth Fault (Ground Fault) • Overcurrent During Acceleration • Arm Overcurrent at start-up • DBR Resistor Overcurrent •Low Current • Voltage Drop In Main Circuit

  • H9 ASD Installation and Operation Manual 35 Keypad Remote Mounting using the ASD-MTG-KIT Note: See Figure 26 for the dimensions and the item locations referenced in steps 1 through 6. 1. At the keypad mounting location, mark the 4.60” by 4.50” hole and the four 11/32” screw holes. 2. Cut the 4.60” by 4.50” rectangular hole. 3. Drill the four 11/32” holes for the Bez

  • Toshiba H9, 136 H9 ASD Installation and Operation Manual Dynamic Braking Program ⇒ Protection ⇒ Dynamic Braking This parameter Enables/Disables the Dynamic Braking system. Settings: 0 — Off 1 — On with Overload Detection 2 — On without Overload Detection Dynamic Braking uses the transistor IGBT7 to dissipate the bus voltage when required. IGBT7 is a standard item on the 25 HP and below H9 ASD 230-volt systems and is standard on the 400 HP and below for the for the 460-volt systems. IGBT7 is optional for all remaining systems. Dynamic Braking Dynamic Braking is used to prevent over-voltage faults during rapid decelerati

  • 106 H9 ASD Installation and Operation Manual V/I Input Point 1 Frequency Program ⇒ Frequency ⇒ Speed Reference Setpoints This parameter is used to set the gain and bias of the V/I input terminal when the V/I terminal is used as the control input while operating in the Speed Control mode. This parameter sets V/I Input Point 1 Frequency and is the frequency that is associated

  • Toshiba H9, 10 H9 ASD Installation and Operation Manual Motor Characteristics Listed below are some variable speed AC motor control concepts with which the user of the H9 Adjustable Speed Drive should become familiar. Motor Autotuning Motor production methods may cause minor differences in the motor operation. The negative effects of these differences may be minimized by using the Autotune feature of the H9 ASD. Autotuning is a function of the H9 ASD that measures several parameters of the connected motor and places these readings in a stored table. The software uses the information in th

  • Toshiba H9, H9 ASD Installation and Operation Manual 279 RX2 (AI1) Input Bias, 163 RX2 (AI1) Input Gain, 163 RX2 (AI1) Input Point 1 Frequency, 117 RX2 (AI1) Input Point 1 Rate, 118 RX2 (AI1) Input Point 1 Setting, 116 RX2 (AI1) Input Point 2 Frequency, 117 RX2 (AI1) Input Point 2 Rate, 119 RX2 (AI1) Input Point 2 Setting, 117 S S/L2, 16 S1, 21, 22 S2, 21, 22 S3, 21, 22 S4, 21, 22 Save User Settings, 75 Second Speed Loop Proportional Gain, 160 Second Speed Loop Stabilization Coefficient, 161 Send Wait Time (2-wire), 206 Setpoints, 59 Short Circuit Detection At Start, 185 Short Circuit Protection, 267 Simple Positioning Completion Range, 151 Sink, 24 Sink/Source Setting Error, 250, 251 Sl

  • Toshiba H9, 228 H9 ASD Installation and Operation Manual Analog Input Function Target 11 Program ⇒ My Function ⇒ My Function Analog This parameter plays a role in the setup of the My Function feature by selecting the functionality of the programmable Analog Input Function Target 11 terminal. The function selected at F961 may be adjusted using the input analog control signal selected here. Settings: 0 — Disabled (None) 1 — V/I 2 — RR 3 — RX 4 — Optional RX2+, RX2- 5 — Optional V/I Direct Access Number — F959 Parameter Type — Selection List Factory Default — 0 (Disabled) Changeable During Run — Ye s Analog Function Assigned Object 11 Program ⇒ My Function �

  • Toshiba H9, H9 ASD Installation and Operation Manual 133 Preset Speed 15 Program ⇒ Frequency ⇒ Preset Speeds This parameter assigns an output frequency to binary number 1111 and is identified as Preset Speed #15. The binary number is applied to S1 – S4 of the Terminal Board to output the Preset Speed (see F018 for more information on this parameter). Direct Access Number — F294 Parameter Type — Numerical Factory Default — 0.00 Changeable During Run — Ye s Minimum — Lower Limit (F013) Maximum — Upper Limit (F012) Units — Hz PWM Carrier Frequency Program ⇒ Special ⇒ Carrier Frequen

  • Toshiba H9, 108 H9 ASD Installation and Operation Manual V/I Input Point 2 Rate Program ⇒ To rq ue ⇒ Setpoints This parameter is used to set the gain and bias of the V/I input terminal when the V/I terminal is used as the control input while operating in the Torque Control mode. Torque Control is accomplished by establishing an associated V/f output pattern for a given V/I input level. This parameter sets V/I Input Point 2 Rate and is the output torque value that is associated with the setting of V/I Input Point 2 Setting when operating in

  • Toshiba H9, H9 ASD Installation and Operation Manual 77 Command Mode Program ⇒ Fundamental ⇒ Standard Mode Selection The Command Mode Selection establishes the source of the command input for the ASD. Command inputs include Run, Stop, Forward, etc. The Override feature may supersede the Command Mode Selection setting (see Command Mode and Frequency Mode Control on pg. 36). Settings: 0 — Terminal Block 1 — Not Used 2 — EOI Keypad 3 — RS485 4 — Communication Option Board Direct Access Number — F003 Parameter Type — Selection List Fa

  • Toshiba H9, 120 H9 ASD Installation and Operation Manual BIN Input Point 1 Setting Program ⇒ Frequency ⇒ Speed Reference Setpoints This parameter is used to set the gain and bias of the BIN input terminals when the BIN terminals are used as the control input while operating in the Speed Control mode. The discrete input terminals of the Terminal Board are used as the BIN terminals. BIN Input Speed Control Setup Perform the following setup to allow the system to receive Speed control input at the BIN input terminals: • Program ⇒ Fundamental ⇒ Standard Mode Selection ⇒ Freque

More Instructions:

DOWNLOAD

Related Products and Documents (Network Card):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 GE Profile PEB1590DM Dimensions and installation information ge/profile-peb1590dm-65W.pdf 21 Nov 2022 2 0.13 Mb
2 Cisco SPA 501G Quick start manual cisco/spa-501g-63M.pdf 16 Jan 2024 2 2.19 Mb
3 Alarko ACK2 Operation manual alarko/ack2-X21.pdf 13 Apr 2023 42
4 Holux GPSmile240 Specifications holux/gpsmile240-FQ2.pdf 24 Feb 2024 3 0.14 Mb
5 C. Crane CCRadio plus Instruction manual c-crane/ccradio-plus-V4Y.pdf 11 Aug 2022 27 0.25 Mb
6 Yamaha TX16W Operating manual yamaha/tx16w-D2W.pdf 01 Jan 2023 44 2.86 Mb

Similar Resources:

  • Ringdale

    Minit 5250E

    (43 pages)
    Copyright  2006 Ringdale User Manual, 62-400310001 Page 1 MinIT 5250E Users Guide User Manual Version 2.4 Copyright Ringdale, Inc. Part number: 62-400310001 …
  • Polycom

    VS4000

    (2 pages)
    VS4000 QuickStartwww.polycom.comAzionare la VS4000servendosi dei tastiseguenti:1. CHIAMA-RIAGGANCIA2. Telecamera LONTANO3. DIAPOSITIVE4. SELEZIONARE5. VOL, volume6. MUTE7. INFO, aiuto8. MENU9. ZOOM10. ISTANTANEA11. freccia12. AUTO13. Telecamera VICINOVerwenden Sie folgendeKnöpfe zur Bedienungder VS4000:1. RUF AUFHÄNGEN2. FERN-Kamera3. DIAS4. AUSWÄHLEN5. L …
  • Crestron

    4 Channel Fan Speed Control Module CLX-1FAN4

    (1 pages)
    ButtonsSETUP: Used for manual channel activation and TSIDLED IndicatorsPWR: (green) Indicates line power is applied to the LINE terminalNET: (yellow) Indicates communication with the control system1 – 4: (red x4) Indicates state of each channelSETUP: (red) Indicates unit is in setup/manual modeEnvironmentalTemperature: 32° to 104°F (0° to 40°C) Humidit …
  • Hi-Link

    HLK-RM04

    (12 pages)
    深圳市海凌科电子有限公司 ShenzhenShenzhenShenzhenShenzhen Hi-LinkHi-LinkHi-LinkHi-Link ElectronicElectronicElectronicElectronic Co.,LtdCo.,LtdCo.,LtdCo.,LtdHttp : //www.hlktech.com Tel : 0755-83575155 Fax : 0755-83575189ShenzhenShenzhenShenzhenShenzhen Hi-LinkHi-LinkHi-LinkHi-Link ElectronicElectronicElectronicElectronic Co.,LtdCo.,LtdCo.,LtdCo., …
  • Moxa Technologies

    Moxa Smartio C168H

    (102 pages)
    Smartio C168H/HS User’s ManualUniversal 8 Port Serial BoardMay 1999 (6th Edition)The content of this manual is also available in CD-ROM and at Moxa Web Site.Moxa Technologies Co., Ltd.Tel: +866-2-8665-6373Fax: [email protected]
  • StarTech.com

    PEX1000SFP

    (10 pages)
    Manual Revision: 08/14/2012For the most up-to-date information, please visit: www.startech.comDE: Bedienungsanleitung - de.startech.comFR: Guide de l'utilisateur - fr.startech.comES: Guía del usuario - es.startech.comIT: Guida per l'uso - it.startech.comNL: Gebruiksaanwijzing - nl.startech.comPT: Guia do usuário - pt.startech.comPEX1000SFPPCI Exp …