  • Toshiba 4200FA, 4200FA Installation and Operation Manual 33 5.0 Specifications 5.1 4200FA 15 / 25 kVA @ 208 VAC Input/ 208 VAC Output - No Internal Batteries or Transformer Model Number C42F3F150XAXXN C42F3F150XAMXN, -S C42F3F150FAMXN, -S C42F3F250XAXXN C42F3F250XAMXN, -S C42F3F250FAMXN, -S Rated Output Capacity 15 kVA 25 kVA External Dimensions W x D x H (cm) w/ casters: 20.0” x 36.3” x 59.7”(50.8 cm x 92.2 cm x 151.6 cm) w/o casters: 20.0” x 36.3” x 60.0”(50.8 cm x 92.2 cm x 152.4 cm) Input Rated Voltage 208

  • Toshiba 4200FA, 4200FA Installation and Operation Manual 55 the UPS and to any attached loads. All LED lamps are "off" and the LCD screen will display the following message: - OUTPUT SHUT DOWN - OUTPUT VOLTAGE= 0 V CURRENT=LOW/LOW/LOW% 6.17 Maintenance Bypass Procedure NOTE: The 25-50kVA 4200 Base models do not come with an internal mechanical MBS. Transferring to Maintenance Bypass will result in loss of power to the critical load unless an external MPS is installed. To safely set the unit in Maintenance Bypass, the UPS is

  • Toshiba 4200FA, 22 4200FA Installation and Operation Manual 4.1.4 Power Connection Cable Routing and Conduit Placement 15/25/30 kVA The following illustrates the proper cable routing that should be followed during the power connection process of the 15/25/30 kVA. Note: 1) Input and Output conductors shall be installed in separate conduits, and installed in accordance with the latest edition of NEC and the Local Authority having jurisdiction. 2) Battery conductors shall be installed in a separate cond

  • 2 4200FA Installation and Operation Manual EQUIPMENT WARNING LABELS DO NOT attempt to install, operate, maintain or dispose of this equipment until you have read and understood all of the product warnings and user directions that are contained in this instruction manual. Shown below are examples of warning labels that may be found attached to the equipment. DO NOT remove or

  • Toshiba 4200FA, 4200FA Installation and Operation Manual 23 4.2 Control Circuit and External Battery Interface Connections 15/25/30 kVA The following illustrates the wiring connections of the Control Circuits, and Battery Interface Circuits. NOTE: Control circuit wiring should be routed in its own conduit. Do not route control circuit wiring through conduit containing UPS power cables. (1) Low Battery (2) Battery Discharge (3) Fault (4) Not Used

  • Toshiba 4200FA, 10 4200FA Installation and Operation Manual 2.0 Product Unpacking / Inspection / Storage / Disposal 2.1 Unpack the Premium 15/25/30 kVA UPS (with Casters) (EXCLUDING Seismic and Base versions – See 2.2) Carefully inspect the UPS for shipping damage. Units shipped within North America and NAFTA are shrink wrapped. 3. Place the tie brackets in the slots at the lower end of the ramps. SLOWLY roll the unit down the ramp. 4. Save the loading rails for seismic anchoring of the UPS. See pg. 14. DANGER TOP HEAVY EQUIPMENT. IMPROPER LIFTING CAN RESULT IN INJURY OR DEATH. LIFT AND MOVE CAREFULLY AND ONLY WITH ADEQUATE EQ

  • Toshiba 4200FA, 32 4200FA Installation and Operation Manual DB9 Female connector outline (facing connector) 5 4 3 2 1 9 8 7 6 The connector pin assignment and female connector outline are illustrated below. 4.5.3 UPS Shutdown (via RS-232C) When the UPS is operating from its internal batteries, a 'shutdown' order can be sent to the UPS instructing it to turn OFF after a user-specified amount of time. This function can allow you to stop discharging the UPS batteries after an orderly system shutdown has been completed.

  • Toshiba 4200FA, 4200FA Installation and Operation Manual 11 2.2 Unpack the Base and Seismic model 15/25/30 kVA UPS (without Casters) (4200FA Base, P/N C42F3FnnnXAXXN and C42F3FnnnXAXBN) (4200FA Seismic, P/N C42F3F250XAMX0S) Carefully inspect the UPS for shipping damage. Units shipped within North America and NAFTA are shrink-wrapped. 1. Remove the shrink wrap from the UPS and Pallet. 2. Unbolt the UPS from the shipping pallet. 3. Use a forklift/pallet jack to lift the UPS off the pallet. Insert the lifting forks through the lifting fork access ports. 4. Use a forklift/floor jack to position the UPS on the pre-drilled mounting holes. See Section 2.7 fo

  • Toshiba 4200FA, 4200FA Installation and Operation Manual 39 5.7 4200FA 50kVA @ 208 VAC Input/ 208 VAC Output - No Internal Batteries, No Internal Transformer Model Number T42F3F500XAXXN T42F3F500XAMXN, -S T42F3F500FAMXN, -S Rated Output Capacity 50 kVA External Dimensions W x D x H (cm) w/ casters: 35.5” X 38.3” X 59.3” (90.1 cm x 97.2 cm x 150.6 cm) w/o casters: 35.5” X 38.3” X 59.7” (90.1 cm x 97.2 cm x 151.6 cm) Input Rated Voltage 208 VAC Voltage Variation 4,5 +10% to -15%; (-10% to -15%) 4 , (-15 to -30%) 5 Rated Frequency 50 / 60 Hz Input Cables Required 3 phase ; 4

  • 28 4200FA Installation and Operation Manual 4.4 Control Circuit and External Interface Connections 50 kVA The following illustrates the wiring connections of the Control Circuits, and Battery Interface Circuits for the 50kVA. NOTE: Control circuit wiring should be routed in it’s own conduit. Do not route control circuit wiring through co

  • Toshiba 4200FA, 4200FA Installation and Operation Manual i TABLE OF CONTENTS TABLE OF CONTENTS ..................................................................................................... i GENERAL SAFETY INSTRUCTIONS .............................................................................. 1 EQUIPMENT WARNING LABELS ................................................................................... 2 IMPORTANT SAFETY INSTRUCTIONS .......................................................................

  • Toshiba 4200FA, 4200FA Installation and Operation Manual 5 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during the installation, maintenance, and operation of the UPS and its batteries to assure safe and proper operation 1. Turn off, lockout, and tagout all power sources before connecting the power wiring to the equipment or when performing maintenance. 2. Hardwire type UPS units are not equipped with an over-current protection device, nor do they have an output disconnect for the a

  • Toshiba 4200FA, 4200FA Installation and Operation Manual 3 4200FA THREE-PHASE 15/25/30/50 kVA UNINTERRUPTIBLE POWER SYSTEM USER’S MANUAL FOR all 15 – 50 kVA MODELS: TOSHIBA INTERNATIONAL CORPORATION INDUSTRIAL DIVISION 13131 West Little York Road Houston, TX 77041-9990

  • 52 4200FA Installation and Operation Manual Note: 1) Line-4 will be blank when the BATT key is pressed during Battery Backup Mode with normal battery voltage. 3) The # symbol signifies numerical values or other information supplied by the UPS. 6.13 Menu Tree This is an overview of the menu tree for the LED display on the UPS detailed in the following p

  • 4200FA Installation and Operation Manual 5 IMPORTANT NOTICE The Instructions contained in this manual are not intended to cover all of the details or variations in equipment or to provide for every possible contingency to be met in connection with installation, operation, or maintenance. Should further information be required or should particular

  • Toshiba 4200FA, 4200FA Installation and Operation Manual 29 * Remote Run and Remote Stop must be enabled via the front panel. Once remote mode is enabled, the key switch on the front panel is rendered inoperable until remote mode is disabled via the front panel. 4.4.1 Recommended Wire Size and Torque Requirements UPS Control and Battery Interface 50 kVA Minimum Wire Size and Torque Requirements UPS Control and Battery Interface Circuits USE MINIMUM 75 °C COPPER WIRING TERMINAL (TERMINAL #) 50 kVA AWG* TIGHTENING TORQUE UPS CONTROL CIRCUITS (1-24)* 14

  • Toshiba 4200FA, 4200FA Installation and Operation Manual 1 GENERAL SAFETY INSTRUCTIONS DO NOT attempt to install, operate, maintain or dispose of this equipment until you have read and understood all of the product safety information and directions that are contained in this manual. Safety Alert Symbol The Safety Alert Symbol indicates that a potential personal injury hazard exists. The symbol is comprised of an equilateral triangle enclosing an exclamation mark. Signal Words Listed below are the signal words that are used throughout this manual followed by their descriptions and associated symbols. When the words DANGER, WARNING and ATTENTION are u

  • Toshiba 4200FA, 24 4200FA Installation and Operation Manual * Remote Run and Remote Stop must be enabled via the front panel. Once remote mode is enabled, the key switch on the front panel is rendered inoperable until remote mode is disabled via the front panel. 4.2.1 Recommended Wire Size and Torque Requirements UPS Control and Battery Interface 15/25/30 kVA *Indicates Class 1 wiring methods are to be used. Maximum Wire Size for Control Circuits is 12 AWG. Maximum for Battery is 1 AWG. No. TERMINAL FUNCTION 1 Low Batt (Dry Contact) Closed when battery voltage drops below minim

  • Toshiba 4200FA, 82 4200FA Installation and Operation Manual Installation Planning Guide for 15-50kVA UPS Standard System: 380V Input, 380/220 V Output For Maximum cable sizes, see Note 7. General Mechanical Information UPS kVA/ kW Rating Dimensions (W x D x H) Weight Lbs. Approximate Full-Load Heat Loss Inches kBTU’s / Hr 15 kVA/12 kW 20 x 36.3 x 59.7 988 7.2 25 kVA/ 20 kW 20 x 36.3 x 59.7 998 10.5 30 kVA/ 24 kW 20 x 36.3 x 59.7 1003 14.3 50 kVA/ 40 kW 35.5 x 38.3 x 59.3 1941 22.6 Primary AC Input (380V 3-

  • Toshiba 4200FA, 84 4200FA Installation and Operation Manual Installation Planning Guide for 15-50kVA UPS Standard System: 480v Input, 480/277V Output For Maximum cable sizes, see Note 7. General Mechanical Information UPS kVA/ kW Rating Dimensions (W x D x H) Weight Lbs. Approximate Full-Load Heat Loss Inches kBTU’s / Hr 15 kVA/12 kW 20 x 36.3 x 59.7 988 7.2 25 kVA/ 20 kW 20 x 36.3 x 59.7 998 10.5 30 kVA/ 24 kW 20 x 36.3 x 59.7 1003 14.3 50 kVA/ 40 kW 35.5 x 38.3 x 59.3 1941 22.6 Primary AC Input (480V 3-Phase / 3-Wire) Maximum Input Power Demand Suggested External Feeder Brea

  • Toshiba 4200FA, 6 4200FA Installation and Operation Manual The maximum ambient temperature in which the Uninterruptible Power System (UPS) should be operated is 104 °F (40 °C) without batteries and 89 °F (32 °C) if the battery cabinet is subject to the same ambient temperature as the UPS. The nominal battery voltage for all internal battery models is 288 VDC. The nominal battery voltage for all external battery models is 288 VDC. An Authorized TOSHIBA Representative who is knowledgeable of batteries and the required precautions should perform service on the batteries. Keep unauthorized personnel away from batteri

  • Toshiba 4200FA, 66 4200FA Installation and Operation Manual Press the F1 key again to display the record relating to each subsequent discharge event. BACKUP HISTORY ( #) #MIN##SEC VB=324V BT *PF OL >∆/∇: EXIT F1: NEXT Press the ‘up’ or ‘down’ arrow keys to return to the Battery Discharge Count screen. BATT DISCHARGE COUNT # TIMES > F1: FOR DETAILS >∆/∇: TO SCROLL Press the ‘up’ or ‘down’ arrow keys to display the Fault Count screen. TOTAL FAULT COUNT ## TIMES > F1: FOR DETAILS >∆/∇: TO SCROLL Press the F1 key to display the record relating

  • Toshiba 4200FA, 4200FA Installation and Operation Manual 19 14) Additional warnings and notifications shall be posted at the equipment installation location as deemed required by Qualified Personnel. CAUTION When the UPS is in the Inverter mode, turning the breaker to the OFF position will cause the unit to go into the battery backup mode. The UPS will continue to provide power to the load. The unit must be in Bypass mode and then the breaker turned to the OFF position for the UPS to shut down power to the load. CAUTION Do not EPO (Emergency Power OFF) the UPS and then reset the breaker until the UPS has been fully discharged. The UPS could be damaged if the unit i

Related Products and Documents (UPS):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Weider 354.156340 Assembly instructions manual weider/354-156340-896.pdf 03 Sep 2023 14 1.28 Mb
2 Campbell COM210 Instruction manual campbell/com210-3V1.pdf 20 Aug 2022 28 0.46 Mb
3 Agri-Fab 45-0357 Owner's manual agri-fab/45-0357-49L.pdf 20 Oct 2022 8 0.37 Mb
4 Dacor PHG30 Use and care manual dacor/phg30-91I.pdf 16 Jan 2023 12 1.14 Mb
5 Aiwa SX-C300 Operating instructions aiwa/sx-c300-629.pdf 14 Feb 2024 2 0.08 Mb
6 Zte Connected Car Start manual zte/connected-car-PNY.pdf 02 Jun 2023 18

Similar Resources:

  • Staco Energy

    FirstLine

    (43 pages)
    The FIRSTLINE UPS 25KVA, 30KVA, AND 37.5KVA Form No.003-2323 Rev B 09/04/2009 301 Gaddis Boulevard • Dayton, Ohio 45403 U.S. Toll Free 866-261-1191 (937) 253-1191 • Fax: (937) 253-1723 Web site: www.stacoenergy.com User’s Manual …
  • Tycon Power Systems

    UPS-ST12

    (8 pages)
    UPS-ST12 / 24 / 48 UPSPro™ Backup Power System ▫ Wireless Base Stations ▫ Surveillance Cameras ▫ Remote Gate Control ▫ Electric Fence ▫ Up to 120W loads Congratulations! on your purchase of the UPSPro™ outdoor backup power system. Please take a moment to review this Qwik Install Guide before assembly or battery installation. DANGER! A …
  • Tripp Lite

    SU6000RT4UHV

    (7 pages)
    Tripp Lite1111 West 35th StreetChicago, IL 60609 USATelephone: +(773) 869 1234E-mail: [email protected] #: SU6000RT4UHVSmartOnline 6kVA On-Line Double-Conversion UPS, 4U Rack/Tower, 200-240V NEMA outlets HighlightsCompletely user hot-swappable—no service call or technician needed Protects rackmount servers, telecom systems and other networkinge …
  • GE

    TLE Scalable Series

    (53 pages)
    Critical Power Installation Guide Uninterruptible Power Supply GE Consumer & Industrial SA General Electric Company CH – 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91 / 850 52 52 www.gecriticalpower.com imagination at work TLES_040-120_S1_UPS_GE_Floor_01 …
  • Energizer

    ER-HM650

    (2 pages)
    ER-HM650Congratulations on your new Energizer® ER-HM650 UPS Power Protection system. This product is specifically designed for personal computer and workstation applications. With the newest technology, this series can operate under a wide range of input utility power while maintaining steady output voltage. Why is this important? Some equipment require …
  • CyberPower

    Value Pro 700VA

    (2 pages)
    Copyright © 2019 Cyber Power Systems, Inc. All rights reserved. …

Comments, Questions and Opinions: