Toshiba RBC-AMS51E-ES Installation Manual
|
Toshiba RBC-AMS51E-ES, – 9 – Lite-Vision plus Remote Controller Installation Manual For first use It takes some time before the remote controller becomes operable when the remote controller is used for the first time. This is not a malfunction. <When the power is turned on for the first t ime after installation> It takes about 5 minutes before the remote controller becomes operable. <When the power is turned on from the second time> It takes about 1 minute before the remote controller becomes operable. Note For the operation of switching the room temperature sensor or th
Toshiba RBC-AMS51E-ES, – 13 – Lite-Vision plus Remote Controller Installation Manual To adjust the clock 2. Name of room Set the name of the room or place where the remote controller is installed. (Operations of the air conditioner are possible without this setting.) 1 Push the [ ∧ ] / [ ∨ ] button to select “1. Clock” on the “Initial setting” screen, then push the “ Set” [ F2] button. 2 Push the [ ∧ ] / [ ∨ ] button to select the year, month, date, and time. ÆPush the “ -” [ F1] / “ +” [ F2] button to set the value. 3 Push the [ MENU] button. The clock display appears on the upper right of the screen. • The clock display blinks if the clock setting has be
Toshiba RBC-AMS51E-ES, – 3 – Lite-Vision plus Remote Controller Installation Manual Accessory Parts No. Part name Quantity (1) Remote controller 1 (2) Screws (small) M4 x 20 2 (3) Wood screws M3.8 x 16 2 (4) Owner’s Manual 1 (5) Installation Manual (This manual) 1 (6) CD-ROM 1 +00EH97062701_00EN.book Page 3 Thursday, March 17, 2011 5:29 PM
– 7 – Lite-Vision plus Remote Controller Installation Manual Wire the remote controller Wiring diagram Terminal block for the remote control wiring on the indoor unit Requirements for wiring of group control • To make wiring of group control for indoor units of 4-way cassette type and other types, set the 4-way cassette type as the header unit; otherw
Toshiba RBC-AMS51E-ES, – 14 – Lite-Vision plus Remote Controller Installation Manual EN 3. Screen contrast Adjust the contrast of the LCD. To delete a character, highlight “Del” and push [ MENU] button. To confirm the name, highlight “Fix” and push [ MENU] button. ÆThe screen returns to the “Initial setting” screen. 1 Push the [ ∧ ] / [ ∨ ] button to select “3. Screen contrast” on the “Initial setting” screen, then push the “ Set” [ F2] button. 2 Push the “ -” [ F1] / “ +” [ F2] button to adjust. 3 Push the [ MENU] button. ÆThe screen returns to the “Initial setting” scree
Toshiba RBC-AMS51E-ES, – 22 – Lite-Vision plus Remote Controller Installation Manual EN Entering information manually Entering the contact number for service 1 Push the [ ∧ ] / [ ∨ ] button to select “2. Register service info” on the field setting menu screen. 2 Push the “ Set” [ F2] button. ÆThe setting screen for entering information appears. 3 Enter the information with the “ ←” [ F1] / “ →” [ F2] button and [ ∧ ] / [ ∨ ] button. Item Function 1. Service contact tel No. Enter the contact number
– 17 – Lite-Vision plus Remote Controller Installation Manual 7. Language Select a language for the screen text. 1 Push the [ ∧ ] / [ ∨ ] button to select “7. Language” on the “Initial setting” screen, then push the “ Set” [ F2] button. 2 Push the [ ∧ ] / [ ∨ ] button to select a language. 3 Push the [ MENU] button. The screen text changes to the selected lan
Toshiba RBC-AMS51E-ES, – 20 – Lite-Vision plus Remote Controller Installation Manual EN 1 Push the [ ∧ ] / [ ∨] button to select “1. Test Mode” on the “Field setting menu screen, then push the “ Set” [ F2] button. ÆPushing the “ Yes” [ F1] button sets the test mode and the screen returns to the field se tting menu screen. Push [ CANCEL] twice, the screen (2) appears. 2 Push the [ ON / OFF] button to start the test mode. The screen (1) shown in the left appears. (The screen (2) app
Toshiba RBC-AMS51E-ES, – 24 – Lite-Vision plus Remote Controller Installation Manual EN Selecting the model name and serial No. 2 Push the [ ∧ ] / [ ∨ ] button to select “1. Manual model name input” on the “ Outdoor model name” screen, then push the “ Set” [ F2] button. ÆSelect “1. Manual serial No. input” to enter the serial number of the outdoor unit. ÆSe lect “1. Manual model name input” to enter the model name of the indoor unit. ÆSe lect “1. Manual serial No. input” to enter the serial number
Toshiba RBC-AMS51E-ES, – 11 – Lite-Vision plus Remote Controller Installation Manual Monitor screen Check the current usage status. NOTE Total running hour • The Total running hour is recorded on the remote controller. • The time is not recorded during Self cleaning operation or fan operation. Outdoor temp. • Displays the temperature around the vent of the outdoor unit. • The displayed temperature may differ from the actual outdoor temperature. Others • The Header status appears during group connection. 1 Push [ MONITOR] button. The monitor screen appears. 2 Push [ CANCEL] button to return. (1) Displays the set temperature. (2) Displays the temperature measured by the indoor tem pera
Toshiba RBC-AMS51E-ES, – 5 – Lite-Vision plus Remote Controller Installation Manual ◆ Remote control wiring and inter-unit wiring between remote controllers Do not allow the wire for the remote controller (communication wire) and the wire for AC220-240 V to come into contact or put them together in one electrical conduit; otherwise, the control system may have trouble due to noise. * Varies depending on the type of remote controller used. ◆ Installation of multiple remote controllers To install two or more
Toshiba RBC-AMS51E-ES, – 21 – Lite-Vision plus Remote Controller Installation Manual Using the Service monitor with the [ MONITOR] button during the test mode 2. Register service info Register information about the contact number for service, model name and serial number of the indoor unit and outdoor unit. • Enter information manually for a Light commercial outdoor unit. Information data of Light commercial indoor unit, multi indoo r unit, and VRF outdoor unit is loaded automatically. Automatic loading is not available for some models. In this case, enter
– 10 – Lite-Vision plus Remote Controller Installation Manual EN Part Names and Functions Switching between the normal display and detailed display Push and hold the [ CANCEL] button and [ MONITOR] button at the same time for more than 4 seconds to switch the display mode. The normal display mode is selected as factory default setting. Normal display mode (factory default) De
Toshiba RBC-AMS51E-ES, – 8 – Lite-Vision plus Remote Controller Installation Manual EN Basic wiring diagram NOTE Terminals of A and B have no polarity. To diverge from the indoor unit To diverge from the header remote controller To operate a group control of multiple indoo r units by two remote controllers * The header or follower remote controller can be connected to any indoor unit. Remote control wiring (Locally procured) 0.5 mm 2 to 2.0 mm 2 . Remote controller (header) Remote controller (follower) (Sold
Toshiba RBC-AMS51E-ES, – 23 – Lite-Vision plus Remote Controller Installation Manual Entering the model name and serial number Enter the model name and serial number manually for a Light commercial outdoor unit. Information data is loaded automatically for Light commercial indoor units, VRF indoor units (excluding large capacity air discharge type and duct type), and VRF outdoor units. Enter the model name and serial number manually after replacing the circuit board to the service circuit board (unless entering information manually before replacement
Toshiba RBC-AMS51E-ES, – 18 – Lite-Vision plus Remote Controller Installation Manual EN 8. Press & hold 4sec. Set the “press and hold” operation for the [ ON / OFF] button. 1 Push the [ ∧ ] / [ ∨ ] button to select “8. Press & hold 4sec.” on the “Initial setting” screen, then push the “ Set” [ F2] button. 2 Push the [ ∧ ] / [ ∨ ] button to select “ON” or “OFF”. 3 Push the [ MENU] button. ÆWhen “ON” is selected, the air-conditioner starts / stops running when the [ ON / OFF] button is pressed and hold 4 seconds. ÆW hen “OFF” is selected, the air-conditioner starts / stop
Toshiba RBC-AMS51E-ES, – 27 – Lite-Vision plus Remote Controller Installation Manual 5. DN setting Perform the advanced settings for the air conditioner. Carry out the setting operation while the indoor unit is sto pped. (Turn off the air conditioning unit before starting the setting operation.) 1 Push the [ ∧ ] / [ ∨ ] button to select “5. DN setting” on the “Field setting menu” screen, then push the “ Set” [ F2] button. ÆThe fan and louver of the indoor unit operate. When the group control is used, the fan and louver of the selected indoor unit operate. ÆMove the cursor to sel
Toshiba RBC-AMS51E-ES, – 28 – Lite-Vision plus Remote Controller Installation Manual EN .................................................................................................. .................................................................................................. .................................................................................................. .................................................................................................. .................................................................................................. .................................................................................................. .......
– 26 – Lite-Vision plus Remote Controller Installation Manual EN 4. Monitor function The sensor temperature or operational status of indoor unit, outdoor unit, or remote controller can be monitored. 1 Push the [ ∧ ] / [ ∨ ] button to select “4. Monitor function” on the “Field setting menu” screen, then push the “ Set” [ F2] button. ÆPush the [ ∧ ] / [ �
Toshiba RBC-AMS51E-ES, – 1 – Lite-Vision plus Remote Controller Installation Manual Contents Precautions for Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Accessory Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Requirements to install the remote controller. . . . . . . . . . . . . . . . . . . . . . . . . . .
Toshiba RBC-AMS51E-ES, – 12 – Lite-Vision plus Remote Controller Installation Manual EN Initial setting 1. Clock Set the year, month, date, and time. 1 Push the [ MENU] button to display the menu screen. 2 Push the [ ∧ ] / [ ∨ ] button to select “10.Initial setting”on the menu screen, then push the “ Set” [ F2] button. 3 Push the [ ∧ ] / [ ∨ ] button to select an item on the “Initial setting” screen. 4 Push the “ Set” [ F2] button. ÆThe selected menu setting screen will be displayed. 5 Push the [ CANCEL] button to return. ÆThe screen returns to the menu screen. 1 Push the [ ∧ ] / [ ∨ ] button to select
Toshiba RBC-AMS51E-ES, – 19 – Lite-Vision plus Remote Controller Installation Manual Field setting menu 1. Test Mode Set for the test operation after installation. Before the test mode • Perform the followings before turning on the power: 1) By using 500 V-megger, check that resistance of 1 MΩ or more exists between the terminal block of the power supply and the earth (earthing). If resistance of less than 1 MΩ is d etected, do not run the unit. 2) Check all valve of the outdoor unit is opened fully. • To protect the compressor at the time of startup,
Toshiba RBC-AMS51E-ES, – 2 – Lite-Vision plus Remote Controller Installation Manual EN Precautions for Safety • Read these “Precautions for Safety” carefully before installation. • The precautions described below include important items regarding safety. Observe them without fail. Understand the following details (indications and symbols) b efore reading the body text, and follow the instructions. • Ask customer to keep this Manual at accessible place for future reference. Indication Meaning of Indication WARNING Text
Toshiba RBC-AMS51E-ES, Toshiba XXXXXXX(X/X) Installation Manual English Lite-Vision plus Remote Controller Model name: RBC-AMS51E-ES RBC-AMS51E-EN • Read this manual before using the RBC- AMS51E-ES, RBC-AMS51E-EN remote controller. • Refer to the Installation Manual supplied with the indoor unit for any installation instructions other than operations of the remote controller. Installation Manual +00EH97062701_00EN.book Page 1 Thursday, March 17, 2011 5:29 PM
Toshiba RBC-AMS51E-ES, – 25 – Lite-Vision plus Remote Controller Installation Manual Checking the model name or serial number The model name or serial number to be displayed on the Ou tdoor (Indoor) model name or Outdoor (Indoor) unit serial No. screen is displayed. 3. Alarm history List of latest 10 alarm data: error information of check code, date, time, and unit, is displayed. Deleting the alarm history 1 Push the [ ∧ ] / [ ∨ ] button to select “3. Alarm history” on the “Field setting menu” screen, then push the “ Set” [ F2] button. List of latest 10 Al
DOWNLOAD |
Toshiba RBC-AMS51E Remote Control Quick reference manual
RBC-AMS51E |
Toshiba RBC-AMS41UL Remote Control Owner's manual
RBC-AMS41UL |
Toshiba RS-TX60 Remote Control Specification sheet
RS-TX60 |
Toshiba RBC-AX22CE Remote Control Owner's manual
RBC-AX22CE |
Toshiba TCB-AX21U-E Remote Control Owner's manual
TCB-AX21U-E |
Toshiba NG-ATH18 Remote Control Operation & user’s manual
NG-ATH18 |
Toshiba RS-TX60 Remote Control Viewer's manual
RS-TX60 |
Toshiba RBC-IR2-PE Remote Control Owner's manual
RBC-IR2-PE |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Ultra Start | 1500 SERIES | Installation manual | ultra-start/1500-series-2DG.pdf | 20 Oct 2022 | 12 | 0.59 Mb |
2 | Lexmark | T420 | User reference | lexmark/t420-SLG.pdf | 01 Feb 2024 | 159 | |
3 | Husqvarna | 1365GN | Owner's manual | husqvarna/1365gn-K4Z.pdf | 23 Mar 2023 | 25 | |
4 | 2N | ATEUS | Operation & user’s manual | 2n/ateus-ZWI.pdf | 25 Dec 2022 | 58 | 1.84 Mb |
5 | Backyard Creations | 272-4027 | Instruction manual | backyard-creations/272-4027-KM3.pdf | 06 Mar 2023 | 2 | |
6 | Stairville | Crazy Par Bundle4 8x5W RGBWAP | Operation & user’s manual | stairville/crazy-par-bundle4-8x5w-rgbwap-FC4.pdf | 16 Jul 2022 | 60 |
Rosslare
AY-L23 and SA-23-B2/B4 Outdoor Long-Range RF Reader and Remote Controls Installation and Operation Manual 1 1. Introduction The AY-L23 is an outdoor long-range RF reader that acts as a receiver. It is compatible with Rosslare’s SA-23 wireless remote control transmitters: SA-23-B2 – 2-Button Remote Control SA-23-B4 – 4-Button Remote Control T …
SA-23-B4(4 pages) |
ARC
Version 2. pecification: Function: 3 sets On / Off / Dimmer 1 set of Group On/Off Frequency: 433.92MHz Battery: 3V CR2032 lithium cell battery verview: Control your lighting with a single touch and take control under your own hands. Slim 8 button remote control with 3 sets of ON/OFF button and 1 set of group ON/OFF function. airing: Pairin …
PBT-707(4 pages) |
Vaillant
en Safety instructionscs Bezpečnostní pokynyda Sikkerhedsanvisningerde Sicherheitshinweiseel Υποδείξεις ασφαλείαςes Notas de advertenciaet Ohutusjuhisedfi Turvaohjeetfr Consignes de sécuritéhu Biztonsági utasításokhr Sigurnosni naputakit Avvertenze di sicurezzako 안전 지침lt Saugos nuorodoslv Drošības norādījuminl Veiligheid …
VR 920(176 pages) |
Carrier
My-Comfort ControllerNTC42GW----K42N (NTC)42JW---KOWNER’S MANUALBEDIENING EN ONDERHOUDMANUALE DELL’UTENTE O MANUEL DE L’UTILISATEUR MANUAL DO UTILIZADORGEBRAUCHSANWEISUNGDRIFT- OCH SKÖTSELINSTRUKTIONMANUAL DEL USUARIO KÄYTTÄJÄN KÄSIKIRJA
…
NTC(64 pages) |
Sony
Help GuideRemote CommanderRMT-P1BTUse this Help Guide when you have issues or questions on how to use your Remote Commander.Supported camera modelsIdentifying the partsPreparationsUnpackingInserting the batteryConnecting the Remote Commander and a camera with the Bluetooth® functionPreventing unintentional operationsShootingShooting a still imageShooting a …
RMT-P1BT(24 pages) |
Satel
® MPT-300 REMOTE CONTROL KEYFOB mpt300_en 03/12 The MPT-300 keyfob enables you to operate the MICRA security system (firmware version 2.02 or newer). Information on adding keyfobs and functions that can be run with their assistance is contained in the MICRA alarm module manual. 1. Features Transmissions secured by KeeLoq code hopping. 5 buttons …
MPT-300(2 pages) |
Miele Oven DGC 5080 XLOven #E211G3 DGC 5080 XL, 64 |
O2 Handhelds OrbitPDF User Manual (@4W26L7), O2 Orbit Handhelds (27.11.2023) Orbit, 206 |
Hisense Refrigerator RB403N4EW1Hisense RB403N4EW1 Guide (Doc Type: Refrigerator User's operating manual) RB403N4EW1, 19 |
GE Ranges JSP26Ranges #3E5CFQ JSP26, 12 |
Bosch Blender MSM6 seriesMSM6 series (Blender ePDF Guide, #R59C2B) MSM6 series, 48 |
HELIX Other SPXL 12HELIX SPXL 12 Manual (Doc Type: Other Datasheet) SPXL 12, 1 |
Kenwood Transceiver TS-770Kenwood Transceiver Operating manual (File: kenwood-ts-770-operating-manual-27, 12th Jan 2024) TS-770, 27 |
Planar Monitor PQ1910MPlanar Product User Guide: PQ1910M PDF Operation & user’s manual - 3IY9VN PQ1910M, 20 |
IEI Technology Motherboard Kino-9454#Q2M562: Kino-9454 Motherboard Operation & user’s manual Kino-9454, 168 |
Boss Audio Systems Car Receiver 514CABoss Audio Systems Car Receiver Operation & user’s manual (File: boss-audio-systems-514ca-car-receiver-10, 22.01.2024) 514CA, 10 |
Rotronic Measuring Instruments CF1 SeriesRotronic CF1 Series Measuring Instruments Short instruction manual CF1 Series, 4 |
Godox Camera Flash V350NGodox Camera Flash V350N Instruction manual V350N, 14 |