Manualios.com

Toshiba RKP002Z Instruction Manual

Toshiba RKP002Z Manual Online:

4.85, 1442 votes
Toshiba RKP002Z User Manual
Toshiba RKP002Z User Guide
Toshiba RKP002Z Online Manual

Text of Toshiba RKP002Z User Guide:

  • Toshiba RKP002Z, E6581277c Remote Keypad Instruction Manual RKP002Z NOTICE 1. Make sure that this instruction manual is delivered to the end user of Remote Keypad. 2. Read this manual before installing or operating the Remote Keypad. Keep it in a safe place for reference. 3. All information contained in this manual are subject to change without notice. Please confirm the latest information on our web site “www.inverter.co.jp”.

  • Toshiba RKP002Z, E6581277c - 1 - Safety precautions On the inverter and in its instruction manual, important information is contained for preventing injuries to users, damages to assets, and for proper use of the device. Read the instruction manual attached to the inverter along with this instruction manual to completely understand the safety precautions, the symbols and indications shown below. Please adhere to the contents of these manuals at all times. Explanation of markings Marking Meaning of marking Danger Indicates that errors in operation may lead to death or serious injury. Warning Indicates that errors in opera

  • E6581277c - 2 -  Limitation of use Safety precaution Never use this unit with any device other than TOSVERT series inverters. Doing so may cause an accident.  Handling in general Danger Never Disassemble Never disassemble, modify or repair the product. Disassembling the product may cause electric shocks, fire or injuries. For repairs, call your sales/repair agency. Pro

  • Toshiba RKP002Z, E6581277c - 3 -  Operations Danger Prohibited Do not apply a dropping shock or other physical shocks. Otherwise, damage or malfunction will result. Do not pull on the cable and connector It may cause damage or error. Even if this product is deactivated by an unusual event such as tripping, an operating error, power outage, etc. do not bring any regions of your body into contact with the inverter terminals when power is supplied to the inverter. Contact during the power-on status of the inverter can result in electric shock. Mandatory Use an additional safety device with your inverter or system to prevent a serious accident due to the unit malfunctions. Usage without an additional

  • Toshiba RKP002Z, E6581277c - 4 - Preface Thank you for purchasing Remote Keypad (RKP002Z ) for TOSVERT series inverters. Using this product, panel operation, display and adjustment of the inverter can be remotely controlled from up to 5 meters away. You can copy data from one place to another and then execute data comparison between the inverter and the memory of Remote Keypad or between the memories of Remote Keypad itself. Before using Remote Keypad, carefully read this instruction manual in order to completely and correctly utilize Remote Keypad’s excellent performance. After reading this instruction manual, please keep it hand

  • Toshiba RKP002Z, E6581277c - 5 - Table of contents 1. Overview・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 6 2. Names and functions of main parts ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 7 3. Connection and start-up�

  • Toshiba RKP002Z, E6581277c - 6 - 1. Overview The following seven functions are available with Remote Keypad. 1. Function to serve as remote operation panel. Remote Keypad can be used as a remote operation panel for the inverter. 2. Copying function Data can be copied from one memory to another memory among the four memories, three (memories A, B, C) on Remote Keypad and one on the inverter. (i) Data copy from Remote Keypad to inverter (ii) Data copy from inverter to Remote Keypad (iii) Data copy from one memory to another memory on Remote Keypad 3. Simple copying function

  • Toshiba RKP002Z, E6581277c - 7 - 2. Names and functions of main parts The drawings below show names and functions of main parts.  Front view 8((8 COPY MODE RUN PRG MON EASY Hz % RUN A STOP B MODE ESC ENT EASY Hz lamp *1 Lights when displayed values are Hz. % lamp *1 Lights when displayed values are %. Operation keys  In “REMOTE KEYPAD MODE”, the key functions are the same as that o f the inverter. See the inverter instruction manual.  In “COPY MODE”, refer to the next page about the key functions. MON lamp Lights when the inverter

  • Toshiba RKP002Z, E6581277c - 8 -  Operation keys and their functions in “COPY MODE” The operation key’s functions in “COPY MODE” are explained in the following table. O p eration key Function O p eration key Function RUN A Memory A key (Exclusive key for simple copying) In the simple copying function, this key is used to specify memory A of Remote Keypad as the origin of transmission data. (In “REMOTE KEYPAD MODE”: RUN key) STOP B Memory B key (Exclusive key for simple copying) In the simple copying function, this key is used to specify memory B of Remote Keypad as the origin of

  • Toshiba RKP002Z, E6581277c - 9 - 4. Functions in detail Remote Keypad can be used as remote operation panel (“REMOTE KEYPAD MODE”) or parameter back-up device (“COPY MODE”). When the “COPY MODE” lamp is lit when turning power on, Remote Keypad operates in “COPY MODE”, otherwise in “REMOTE KEYPAD MODE”. 4.1. Procedure to switch the operation mode According to the procedure described in “3. Connection and start-up”, turn on the power of Remote Keypad while holding down the [ENT] key of Remote Keypad. Operation mode changes. 4.2. “REMOTE KEYPAD MODE” In “REMOTE KEYPAD MODE”, operation is the same as operation on the

  • Toshiba RKP002Z, E6581277c - 10 - 4.3.1. Copying function “copy” The data stored in a memory can be copied to another memory selected from among four memories (the inverter's memory and Remote Keypad memories A, B, and C). Remote Keypad can not be used to copy parameters from one inverter to another inverter of a different series. N.B.: To copy the data to the inverter’s memory, do it when the inverter has stopped . If you copy the data to the inverter while the inverter is running, some of the parameters fail to be copied. Operating procedure Key LED indication Key operation and description ⎯⎯⎯⎯ “copy” < Selecting a desired function > Select “c0py” (copying functio

  • Toshiba RKP002Z, E6581277c - 11 - 4.3.2. Simple copying function The data stored in the memory A, B or C of Remote Keypad can be copied to the inverter's memory with simple operation of two keys to select one of the memories A, B and C. Use this function to set the same parameters to more than two inverters. Remote Keypad can not copy parameters to from one inverter to another inverter of a different series. What differs from the “Copying function” in Section 4.3.1 is the key operation and the contents of parameters to be copied are the same for both functions. It i

  • Toshiba RKP002Z, E6581277c - 12 - 4.3.3. Comparing function “comp” This function enables the operator to compare data stored in two memories selected from among four memories (the inverter’s memory and Remote Keypad memories A, B, and C) as well as to search for parameters that differ from each other. The comparing function cannot be used for editing parameters because it is provided only for searching parameters that differ from each other. Use the “REMOTE KEYPAD MODE” function described in section 4.2 to edit parameters. Operating procedure Key LED indication Key operation and description SF

  • Toshiba RKP002Z, E6581277c - 13 - 4.3.4. Memory protection function “prot” The memory protection function protects the selected memory from being overwritten. When this function is initiated copying data to the memory is prohibited. Reading the memory data is permitted. When all the memories are initialized by memory initialization function (clr), the LED indications are as follows: “in”, “a”, “b”, “c” = “off”, “sup” = “on” This is also the default setting at the time of shipment. Operating procedure Key LED indication Key operation and de

  • Toshiba RKP002Z, E6581277c - 14 - 4.3.5. Memory initializing function clr A selected one of the memories either memory A, B, C of Remote Keypad is enable to be initialized with this function. In addition, all memories including system memory of Remote Keypad is also enable to be initialized. Operating procedure Key LED indication Key operation and description SFT “copy” → “comp” → “prot” → “clr” < Selecting a desired function > Select “clr” (memory initializing function) with the [SFT] key. ENT “clr” → “a” < Entering the selected function > Af

  • Toshiba RKP002Z, E6581277c - 15 - 4.3.6. Remote Keypad parameter editing function This function allows the user to edit the parameters of Remote Keypad. Remote Keypad parameter list Title Function Description f-01 Software version displaying Display shows the software version of Remote Keypad. f-02 Automatic comparing function Automatic comparing function can be turned on or off. 0: Not executing comparison after copying 1: Executing comparison after copying (default) Warning It is recommended to set the automatic comparing

  • Toshiba RKP002Z, E6581277c - 16 - 5. Before making a service call If a problem arises, please see the following trouble-shooting tables. If the problem can not be solved, please contact a Toshiba distributor. 5.1. Error message Malfunction indications: Indicated by flashing LED display Error Code Problem and Solutions raMe RAM built in Remote Keypad is abnormal. If the same indication appears after resetting Remote Keypad, it needs to be repaired. roMe ROM built in Remote Keypad is abnormal. If the same indication

  • E6581277c - 17 - 5.3. Warning indications Warning indications: Indicated by flashing LED display. Warning Code Problem and Solutions prot The target memory to copy data or to initialize is write protected. Copying any data to the memory or initializing the memory cannot be executed. Press the [ESC] key to cancel. deVe The type of device is different (diff

  • E6581277c - 19 -  Mounting Mount Remote Keypad on the front of the panel board as illustrated below. On the front of the panel board, cut the area shown below for mounting Remote Keypad. Then, fix Remote Keypad on the panel board with the mounting screws (M3 x 12) supplied as accessories. (M3 screw tightening torque: 0.6 Nּm) Unit: mm (The front view of the panel b

  • E6581277c - 20E - 7. Specifications Item Specifications Part number RKP002Z Applicable model Model with either an RS485 (2-wire type) connector or a common serial connector (optional) with a baud rate of 9600, 19200 or 38400bps. Communication Automatic search: Baud rate: 9600, 19200, 38400bps Parity: even, odd, none Communication method: RS485 (2-wire type) or Common Seri

Related Products and Documents (Remote Control):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Philips 1335 series Quick start manual philips/1335-series-QX5.pdf 12 Oct 2022 10
2 Supermicro PDSLA Operation & user’s manual supermicro/pdsla-U55.pdf 10 Dec 2023 79
3 Amana NGD7200TW10 Top and console parts amana/ngd7200tw10-SQH.pdf 19 Jun 2023 9 1.09 Mb
4 Grandstream Networks GXE5024 Operation & user’s manual grandstream-networks/gxe5024-534.pdf 04 Jul 2023 10 0.51 Mb
5 Emerson XR530D Installing and operating instructions emerson/xr530d-G86.pdf 27 May 2023 4 0.19 Mb
6 Philips HB568/01 Operation & user’s manual philips/hb568-01-FTO.pdf 22 Jan 2024 96 1.11 Mb

Similar Resources:

  • Atlas

    WHISPERTOUCH DWT-8

    (2 pages)
    © 2001 Atlas Sound LP Printed in U.S.A. 000801 PN 389516 SL4-15702651601 JACK MCKAY BLVD. / ENNIS, TEXAS 75119 U.S.A. / TELEPHONE: (800) 876-3333 / FAX (800) 765-3435"ORIGINAL" WHISPERTOUCH®8-OHM STEREO VOLUME CONTROLSDWT-8* uffix model with color: ivory(-I), white (-W). ***E.O. Box by others. Carlon Model B120A or equivalent recomme …
  • ADB

    FOCUS 3-MODE

    (8 pages)
    Remote ControlInstructionBookletTable Of ContentsKey Code ListSetting up the Focus 3-ModeTo Search for your Television CodeCode Blink OutQuick Code ReferenceVolume Punch ThroughTo Set Up a MacroTo Clear a Macro SetupFeature Reset (980)TroubleshootingBrand Setup Code List...............................................................Page 2.................... …
  • AJAX

    GlassProtect

    (16 pages)
    GlassProtect User manualUpdated June 8, 2020GlassProtect is a wireless indoor glass break detector recognizing the sound ofshattering the glass at a distance of up to 9 meters. GlassProtect can operateup to 7 years from a pre-installed battery and has a socket for connecting athird-party wired detector.GlassProtect connects to the Ajax security system via th …
  • SOMFY

    Nina IO

    (61 pages)
    Ref.SUMMARY1Naturally Intuitive Naturally AttractiveInstructionsWELCOME PAGE 21. SAFETY 32. NINA IO REMOTE CONTROL 53. USE NINA IO 13Control an item of equipment 13My function 15Natural Control function 19Load a scenario 22Alarm function 234. CUSTOMIZE NINA IO 25Customize equipments 25Customize groups 29Customize scenarii 35Customize the remote …
  • Nibe

    POOL 40

    (92 pages)
    InstallatörshandbokPooluppvärmningSEInstaller manualPool heatingGBInstallateurhandbuchPoolerwärmungDEAsentajan käsikirjaAllaslämmitysFIIHB 1940-12031432POOL 40LEKS1155 / S1255 / SMO S40F1145 / F1245 / F1155 / F1245 / F1345 / F1355 / SMO 40 …
  • THOMSON

    DHD 4000

    (33 pages)
    User ManualDHD 4000DHD 4000ModelTHOMSON Sales UK Ltd30 Tower View - Kings HillWest Malling - Kent ME19 4NQEnglandhttp://www.thomson-europe.comDealer's address3573160A00 © Copyright THOMSON 2003Contents1 Introduction2 Safety Information3 Accessories3 Remote Control Handset5 Connections8 Basic OperationTurning on and off and changing channels9 Using the …

Comments, Questions and Opinions: