Samsung SDM-090 Operation & User’s Manual
|
Samsung SDM-090, Digital Multiplexer 5-2 - The following screen is displayed if pressing the “ENTER” button with the blinking position placed at the “DUTY SET ….”. ¥ The blinking indication moves if pressing “ ”, “ ” button. ¥ The setting value is changed if pressing “ ”, “ ” button:OFF,1~5. ¥ The relevant channel is not recorded if the setting value is “OFF”. ¥ The changed setting value is stored if pressing the “SET” button.You can return to the main menu. - The following screen is displayed if pressing the “ENTER
Samsung SDM-090, Appendix B Checking points in trouble There may be a case not to use system properly since unexpected status occurs while using the system. In this case, such status is actually caused by a critical error in system but a simple first-aid can solve this status in the most case. The following items must be checked when problem occurs in the use of this unit. When power does not turn on. ¥ Ensure power cord is properly inserted. When screen does not appear though the power cord is inserted. ¥ Ensure connection to the camera, monitor output terminal is properly performed. When record is not done. ¥ Ensure the connection between the video-in terminal of V
Samsung SDM-090, Digital Multiplexer 5-4 - The following is displayed if pressing the “ENTER” button with the blinking position placed at the “SPOT OUT...”: ¥ You can set the sequence time of SPOT output. ¥ The blinking indication moves if pressing “ ”, “ ” button. ¥ The setting value is changed if pressing “ ”, “ ” button. CH1~CH9 : 0 to 30 seconds. Alarm S/W TIME : 01 to 30 seconds. ¥ The changed setting value is stored if pressing the “SET” button and you can return to the “MON OUT SET” menu. ✴ The channel of LOSS or “ 0 ” of sequence time will be skipped in the SPOT output sequence. ✴ SPOT OUTPUT on alarm
Digital Multiplexer 4-5 When desiring to see in the PIP screen The PIP (picture in picture) screen may be seen using the “PIP” button on the FULL screen in the LIVE mode. The size of the PIP sub-screen is set in the “PIP SIZE” of the “2. MON OUT SET” on the program menu. The sub-screen is automatically and sequentially converted if pressing the “SEQUENC
Samsung SDM-090, 2. Setting of display mode You can set LIVE/PB display type, PIP size, sequence, and border color, PB IN, etc.. The following screen is displayed if pressing the “ENTER” button with the blinking position placed at the “2. MON OUT SET” by pressing “MOVE” button on the main menu. - The blinking indication moves if pressing “ ”, “ ” button. - The setting value is changed if pressing “ ”, “ ” button. LIVE DISPLAY: ALL ↔ TITLE ↔ DATE/TIME ↔ NONE ↔ ALL PB DISPLAY : ALL ↔ TITLE ↔ D
Samsung SDM-090, REAR PANEL A. CAMERA INPUT / LOOP THROUGH OUT Up to 9 camera signals can be input.When transmitting camera signals to external devices, OUT terminal can be used. B. ALARM IN / ALARM OUT / VTI TERMINAL -VTI: TRIGGER Output Connection terminal of VCR -ALARM IN: Up to 9 ALARM Sensors can be connected. “G” indicates grounding terminal connected to ALARM Input, and should be connected to grounding terminal of sensors. -ALARM OUT (HOT/COLD): When ALARM is activated, ACTIVE MAKE Signal is generated. -ALARM RESET : Connected to RESET terminal of VCR, and when ALARM is deactivated, PULSE is generated. C. VCR IN/OUT (BNC) Indicates terminal for connecting t
Samsung SDM-090, Digital Multiplexer 7-1 Chapter 7. Occurrence and handling of alarm, loss, motion 1. Alarm occurrence conditions The following events occur if alarm occurs since the sensor is connected to the alarm input terminal on the backside: 1) Warning sounds (if buzzer turns “ON”). 2) Alarm information (date and time when alarm occurs) is recorded on the alarm list. 3) “RESET” LED blinks. 4) The alarm output (HOT, COLD) signal is active for the alarm hold time. 5) The record times of the channel that alarm occurs increase. 6) Screen is converted to the channel that alarm occurs. 7) Display character of “ALARM” or “A” appe
Samsung SDM-090, Digital Multiplexer 3-3 4. Connecting to ALARM SENSOR 1. Connect the ALARM terminal on the Unit’s Rear Panel to the SENSOR CORRESPONDING TO camera number. 2. Connect grounding wires. 3. Connect the HOT terminal on the Unit’s Rear Panel to the ALARM IN terminal on the VCR. 4. Connect the COLD terminal on the Unit’s Rear Panel to the COM terminal on the VCR. 5. Connect the A/R terminal on the Unit’s Rear Panel to the RESET terminal on the VCR. CAUTIONS Depending on the kinds of TIME LAPSE VCR, the name of REC TRIGGER OUT terminal may be different, so be sure
Samsung SDM-090, When desiring to see the stop screen The monitor screen (full screen and division) may be seen with a temporary stop. A desired screen may be temporarily stopped selectively in the division screen indication mode. 1. FREEZE setting of FULL screen The LED turns on and monitor image stops and “FREEZE” character is indicated on the screen if pressing the “FREEZE” button in the FULL screen mode. The LED turns off and the stop mode is released if pressing the “FREEZE” button once again. 2. FREEZE setting of
Samsung SDM-090, Appendix A Specifications 1) Image input Camera: 9 input (BNC Type, Loop Through) 1.0Vp-p, 75 Ω automatic termination, CVBS VCR : 2 input (VCR Playback input) VBS entry (BNC Type),1.0Vp-p, 75Ω terminations S-VHS Y/C input – Y: 1.0Vp-p, 75Ω terminations – C: 0.286Vp-p(NTSC), 0.3Vp-p(PAL) 75 Ω terminations – SDM-090M/SDM-090MP:Not used. 2) Image output Monitor: 3 output SPOT output (BNC Type),1.0Vp-p, 75Ω termination Main monitor output (BNC Type),1.0Vp-p, 75 Ω terminations S-VHS Y/C output –
Samsung SDM-090, 5. Remote Control by connecting to PC A. Connecting to RS-232C The unit can be remote-controlled by connecting to PC in which terminal emulation program is built. At this time, RS-232C Cable is used for connection. When connecting to the PC by RS-232C, some keys on the PC keyboard can be used as Function Buttons on the Unit’s Front Panel. RS-232C Terminal(D-SUB 9PIN) RS-232C 9PIN(Connector Allocation) PIN NUMBER PIN SPECIFICATIONS 2 TXD(TRANSMITTEDDATA) 3 RXD(RECEIVEDDATA) 5 SG(SIGNALGROUND) 1, 4, 6~ 9
Samsung SDM-090, 3. Connecting to TIME LAPSE VCR When connecting the unit to the TIME LAPSE VCR, set “TLV” in “REC TYPE” after selecting “1.REC OUT SET” of SETUP MENU. 1. Connect a S-JACK cable to the VTI terminal on the Unit’s Rear Panel and to the REC TRIG OUT terminal on the VCR. 2. Connect a S-JACK cable to the ‘G’ terminal on the Unit’s Rear Panel and to the ‘G’ terminal on the VCR. 3. Connect a cable to the VCR IN terminal on the Unit’s Rear Panel and to the VCR OUT terminal on the VCR. Likewise, connect a cable to the VCR IN terminal on the Unit’s Rear Panel and to the VCR OUT terminal on the VCR. CAUTIONS Depending on the
5. Setting of alarm Set operation when alarm occurs. The following screen is displayed if pressing the “ENTER” button with the blinking indication placed at the “5.ALARM SET” by pressing the “MOVE” button on the main menu screen: - The blinking character moves if pressing “ ”, “ ” button. - The setting value is changed if pressing “ ”, “ �
Samsung SDM-090, Name of parts and Function FRONT PANEL A. POWER SWITCH Power ON/OFF. B. MULTI SCREEN DISPLAY - MULTI SCREEN You are in the multi-screen mode. Each press of the MULTI SCREEN Button shows the picture displayed. - REC CHECK LIVE MODE: VCR output is displayed on the monitor. P.B MODE: VCR input is displayed on the monitor. This mode flashes during REC CHECK operation. - LIVE/P. B. Button for selecting either LIVE MODE or Playback MODE. LIVE MODE will be flashed. - TRIPLEX Button for selecting TRIPLEX MODE. Flashes during TRIPLEX operation. - PIP Button for selecting PICTURE-IN-PICTURE. C. CAMERA SELECT Button for selecting proper CHANNEL. D. ALARM - RE
Samsung SDM-090, Digital Multiplexer 3-1 CHAPTER 3. Connecting to Other Devices This unit can be connected to other devices such as monitor, camera, VCR, and PC. This chapter describes how to connect the unit to other devices. CAUTIONS Be sure that voltages higher than 2 VDC should not be input to the input terminal of Camera and Video. 1. Connecting to normal VCR and Monitor When connecting to a normal VCR, Select ‘NOR’ in “REC TYPE” of “1. REC OUT SET” in SETUP MENU. 1. Connect a BNC cable to the VCR IN terminal on the Unit Rear Panel and to the OUT terminal of the VCR. 2. Connect a BNC cable to the V
Digital Multiplexer ii IMPORTANT SAFEGUARDS 1. Read instructions: All the safety and operating instructions should be read before the appliance is operated. 2. Retain instructions: The safety and operating instructions should be retained for future reference. 3. Heed warnings: All warnings on the appliance and in the operating instructions should be adhered to. 4. Follow inst
Samsung SDM-090, When desiring to see in the FULL screen The FULL screen may be seen in the live and tape replay mode, available for 9 channels from No.1 through No.9. ➢ Method to use. Press the camera select button of the desired channel. ➢ The camera select button does not operate in the following cases: - In setting of program mode - In displaying ALARM/LOSS LIST on screen - In setting FREEZE in the division screen - In resetting of channel in the division screen When desiring to see in the division screen The division screen may be seen in the live replay mode and triplex mode and the division mode of 2, 4, 7, 9 e
Samsung SDM-090, Digital Multiplexer 4-1 Chapter 4. Basic Method to use Initial operation 1.Turn on power switch. A 4-division screen appears on the monitor if firstly operating after purchase. In this case, the channel with- out inputting appears in the blue background on the screen and a video loss occurs. (The current operation status is memorized when the power turns off after completing the initial setting and thus the unit operates in the operation status when the power turns off if turning power on.) 2. Setup a recording channel. Set the channel withou
Samsung SDM-090, Chapter 5. Setting of Program Menu <MAIN MENU> The following main menu is displayed on the monitor screen if pressing “MENU” button, the “MENU” LED turns on. The LED turns off if pressing the button and it returns to the previous status. < SUB MENU> - Select item 1~6 of the main menu using the “MOVE” button ( , ). - Press the “ENTER” button to move to the sub-menu. 1.Record setting of each camera You can set record mode and record duty, ON/OFF, reservation of each channel.The following screen is displayed on
Samsung SDM-090, CHAPTER 5. SETTING OF PROGRAM MENU .................... 5-1~ 5-9 Record setting of each camera........................................................................5-1 Setting of display mode....................................................................................5-3 Setting of title by channel.................................................................................5-5 Setting of display mode for current time, year, month and date .....................5-6 Setting of alarm................................................................................................5-7 System setting............................................................................
Paradyne 9161 Multiplexer Reference manual
9161 |
Raisecom RCMS2504-120 Multiplexer Operation & user’s manual
RCMS2504-120 |
Lynx P MX 3312 D Multiplexer Reference manual
P MX 3312 D |
Samsung SDM-090P Multiplexer Operation & user’s manual
SDM-090P |
Raisecom RCMS2201 Multiplexer Operation & user’s manual
RCMS2201 |
Panasonic WJ-FS109 Multiplexer Operating instructions manual
WJ-FS109 |
Samsung SDM-160 Multiplexer Operation & user’s manual
SDM-160 |
Quintum AS Series ASM200 Multiplexer Release note
AS Series ASM200 |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | US Robotics | USR8001 | Quick installation manual | us-robotics/usr8001-DTZ.pdf | 03 Feb 2024 | 66 | 1.35 Mb |
2 | Westone | Universal Monitor | Operation & user’s manual | westone/universal-monitor-9T9.pdf | 10 Dec 2022 | 6 | 0.16 Mb |
3 | Singer | 147-121 | Instructions for using manual | singer/147-121-4N3.pdf | 30 Aug 2022 | 10 | 0.52 Mb |
4 | BMW | 325 1986 | Electrical troubleshooting manual | bmw/325-1986-13R.pdf | 11 Jan 2023 | 125 | 21.96 Mb |
5 | Nikon | Zoom-Nikkor 35-105mm f/3.5-4.5 | Instruction manual | nikon/zoom-nikkor-35-105mm-f-3-5-4-5-522.pdf | 27 Aug 2023 | 40 | |
6 | Zanussi | ZFC 77/31 FF | Instruction booklet | zanussi/zfc-77-31-ff-638.pdf | 03 Dec 2022 | 20 | 1.23 Mb |
Comnet
INS_FVT/FVR401_REV–03/01/12PAGE 1INSTALLATION AND OPERATION MANUAL FVT/FVR4014-CHANNEL DIGITAL VIDEO MULTIPLEXER10-BIT DIGITAL/SHORT-HAULThe ComNet™ FVT/FVR401 multiplexer simultaneously transmits four channels of video over one optical fiber utilizing state-of-the-art 10-bit digital encoding and decoding for high-quality video transmission that meets th …
FVT401(4 pages) |
Viessmann
GebrauchsanleitungManual5229Multiplexerfür Lichtsignale mit Multiplex-TechnologieMultiplexerfor daylight signals with multiplex-technology1. Wichtige Hinweise ...................................... 22. Einführung / Eigenschaften ........................ 23. Anschluss ................................................... 34. Kon guration …
5229(16 pages) |
Siemens
DF8000 Input / Output Multiplexing System Installation Function & Configuration Commissioning Safety Regulations Fire Safety & Security ProductsBuilding Technologies
…
DF8000(46 pages) |
Moog
MOOG PROPRIETARY AND CONFIDENTIAL INFORMATION THIS TECHNICAL DATA/DRAWING/DOCUMENT CONTAINS INFORMATION THAT IS PROPRIETARY TO, AND IS THE EXPRESS PROPERTY OF MOOG INC., OR MOOG INC. SUBSIDIARIES EXCEPT AS EXPRESSLY GRANTED BY CONTRACT OR BY OPERATION OF LAW AND IS RESTRICTED TO USE BY ONLY MOOG EMPLOYEES AND OTHER PERSONS AUTHORIZED IN WRITING BY MOOG OR …
Focal 903(96 pages) |
Renu Electronics
Power (Base) 24VDC(+20%, -15%), 250mA, 6W (for T-E module) 24VDC (+20%, - 15%), 270mA, 6.48W (for TN-E module) Power (with 5 Expansions) 24VDC(+20%, -15%), 500mA, 12W (for T-E module) 24VDC(+20%, -15%), 520mA, 12.48W (for TN-E module) Display 10.1”, 1024 x 600pixels, WVGA color TFT with 4-wire analog resistive touch screen LEDs 1 RAM Mem …
FP4101 Series(2 pages) |
IRT Electronics
4230-mmm & 4230-mmx.ib.rev4.doc Page 1 of 17 17/10/2007 IRT Eurocard Types MMM-4230 & MMX-4230 4 Channel ASI to G.703 Multiplexer / De-Multiplexer I R T Electronics Pty Ltd A.B.N. 35 000 832 575 26 Hotham Parade, ARTARMON N.S.W. 2064 AUSTRALIA National: Phone: (02) 9439 3744 Fax: (02) 9439 7439 International: +61 2 9439 3744 +61 2 …
MMM-4230(23 pages) |
Seagate Storage ST200FM0002PDF Manual (@258293), Seagate ST200FM0002 Storage (30.10.2023) ST200FM0002, 82 |
Peavey Amplifier CS 200X#16S6S5: CS 200X Amplifier Operating manual CS 200X, 12 |
ANALOG OUTFAnalog Outfitters Music Mixer ORGANIC 30 COMBOMusic Mixer Owner's manual (ANALOG OUTFAnalog Outfitters ORGANIC 30 COMBO) ORGANIC 30 COMBO, 4 |
Gefen Extender DVI-1000ST#3KEF5G DVI-1000ST: Gefen Extender Owner Documentation DVI-1000ST, 13 |
JUMO Control Unit mTRON TmTRON T Operating manual - E687P1 mTRON T, 76 |
Fagor Other FQ8925XFQ8925X (Other ePDF Manual, #76Q289) FQ8925X, 48 |
HP Laptop DeskJet 900HP Laptop Reference manual (File: hp-deskjet-900-reference-manual-145, 01/11/2023) DeskJet 900, 145 |
Kenmore Freezer 253.18502Kenmore Freezer Use & care manual (File: kenmore-253-18502-use-care-manual-10, 27th Sep 2023) 253.18502, 10 |
Eelink GPS GPT19-HEelink Product Guide: GPT19-H PDF Operation & user’s manual - QWB518 GPT19-H, 20 |
Sigma Bicycle Accessories ROX 5.0Sigma ROX 5.0 Manual (Doc Type: Bicycle Accessories Installation instructions) ROX 5.0, 2 |
KitchenAid Grill KFRU368TPDF User Guide (@BIJ574), KitchenAid KFRU368T Grill (26/10/2023) KFRU368T, 64 |
DSPPA Speakers DSP5505RUser Manual: DSPPA DSP5505R (A1V552, Upd.13.08.2023) DSP5505R, 5 |