Manualios.com

Samsung SDM-090 Operation & User’s Manual

Samsung SDM-090 Manual Online:

4.8, 2624 votes
Samsung SDM-090 User Manual
Samsung SDM-090 User Guide
Samsung SDM-090 Online Manual

Text of Samsung SDM-090 User Guide:

  • Samsung SDM-090, Digital Multiplexer 5-2 - The following screen is displayed if pressing the “ENTER” button with the blinking position placed at the “DUTY SET ….”. ¥ The blinking indication moves if pressing “ ”, “ ” button. ¥ The setting value is changed if pressing “ ”, “ ” button:OFF,1~5. ¥ The relevant channel is not recorded if the setting value is “OFF”. ¥ The changed setting value is stored if pressing the “SET” button.You can return to the main menu. - The following screen is displayed if pressing the “ENTER

  • Samsung SDM-090, Appendix B Checking points in trouble There may be a case not to use system properly since unexpected status occurs while using the system. In this case, such status is actually caused by a critical error in system but a simple first-aid can solve this status in the most case. The following items must be checked when problem occurs in the use of this unit. When power does not turn on. ¥ Ensure power cord is properly inserted. When screen does not appear though the power cord is inserted. ¥ Ensure connection to the camera, monitor output terminal is properly performed. When record is not done. ¥ Ensure the connection between the video-in terminal of V

  • Samsung SDM-090, Digital Multiplexer 5-4 - The following is displayed if pressing the “ENTER” button with the blinking position placed at the “SPOT OUT...”: ¥ You can set the sequence time of SPOT output. ¥ The blinking indication moves if pressing “ ”, “ ” button. ¥ The setting value is changed if pressing “ ”, “ ” button. CH1~CH9 : 0 to 30 seconds. Alarm S/W TIME : 01 to 30 seconds. ¥ The changed setting value is stored if pressing the “SET” button and you can return to the “MON OUT SET” menu. ✴ The channel of LOSS or “ 0 ” of sequence time will be skipped in the SPOT output sequence. ✴ SPOT OUTPUT on alarm

  • Digital Multiplexer 4-5 When desiring to see in the PIP screen The PIP (picture in picture) screen may be seen using the “PIP” button on the FULL screen in the LIVE mode. The size of the PIP sub-screen is set in the “PIP SIZE” of the “2. MON OUT SET” on the program menu. The sub-screen is automatically and sequentially converted if pressing the “SEQUENC

  • Samsung SDM-090, 2. Setting of display mode You can set LIVE/PB display type, PIP size, sequence, and border color, PB IN, etc.. The following screen is displayed if pressing the “ENTER” button with the blinking position placed at the “2. MON OUT SET” by pressing “MOVE” button on the main menu. - The blinking indication moves if pressing “ ”, “ ” button. - The setting value is changed if pressing “ ”, “ ” button. LIVE DISPLAY: ALL ↔ TITLE ↔ DATE/TIME ↔ NONE ↔ ALL PB DISPLAY : ALL ↔ TITLE ↔ D

  • Samsung SDM-090, REAR PANEL A. CAMERA INPUT / LOOP THROUGH OUT Up to 9 camera signals can be input.When transmitting camera signals to external devices, OUT terminal can be used. B. ALARM IN / ALARM OUT / VTI TERMINAL -VTI: TRIGGER Output Connection terminal of VCR -ALARM IN: Up to 9 ALARM Sensors can be connected. “G” indicates grounding terminal connected to ALARM Input, and should be connected to grounding terminal of sensors. -ALARM OUT (HOT/COLD): When ALARM is activated, ACTIVE MAKE Signal is generated. -ALARM RESET : Connected to RESET terminal of VCR, and when ALARM is deactivated, PULSE is generated. C. VCR IN/OUT (BNC) Indicates terminal for connecting t

  • Samsung SDM-090, Digital Multiplexer 7-1 Chapter 7. Occurrence and handling of alarm, loss, motion 1. Alarm occurrence conditions The following events occur if alarm occurs since the sensor is connected to the alarm input terminal on the backside: 1) Warning sounds (if buzzer turns “ON”). 2) Alarm information (date and time when alarm occurs) is recorded on the alarm list. 3) “RESET” LED blinks. 4) The alarm output (HOT, COLD) signal is active for the alarm hold time. 5) The record times of the channel that alarm occurs increase. 6) Screen is converted to the channel that alarm occurs. 7) Display character of “ALARM” or “A” appe

  • Samsung SDM-090, Digital Multiplexer 3-3 4. Connecting to ALARM SENSOR 1. Connect the ALARM terminal on the Unit’s Rear Panel to the SENSOR CORRESPONDING TO camera number. 2. Connect grounding wires. 3. Connect the HOT terminal on the Unit’s Rear Panel to the ALARM IN terminal on the VCR. 4. Connect the COLD terminal on the Unit’s Rear Panel to the COM terminal on the VCR. 5. Connect the A/R terminal on the Unit’s Rear Panel to the RESET terminal on the VCR. CAUTIONS Depending on the kinds of TIME LAPSE VCR, the name of REC TRIGGER OUT terminal may be different, so be sure

  • Samsung SDM-090, When desiring to see the stop screen The monitor screen (full screen and division) may be seen with a temporary stop. A desired screen may be temporarily stopped selectively in the division screen indication mode. 1. FREEZE setting of FULL screen The LED turns on and monitor image stops and “FREEZE” character is indicated on the screen if pressing the “FREEZE” button in the FULL screen mode. The LED turns off and the stop mode is released if pressing the “FREEZE” button once again. 2. FREEZE setting of

  • Samsung SDM-090, Appendix A Specifications 1) Image input Camera: 9 input (BNC Type, Loop Through) 1.0Vp-p, 75 Ω automatic termination, CVBS VCR : 2 input (VCR Playback input) VBS entry (BNC Type),1.0Vp-p, 75Ω terminations S-VHS Y/C input – Y: 1.0Vp-p, 75Ω terminations – C: 0.286Vp-p(NTSC), 0.3Vp-p(PAL) 75 Ω terminations – SDM-090M/SDM-090MP:Not used. 2) Image output Monitor: 3 output SPOT output (BNC Type),1.0Vp-p, 75Ω termination Main monitor output (BNC Type),1.0Vp-p, 75 Ω terminations S-VHS Y/C output –

  • Samsung SDM-090, 5. Remote Control by connecting to PC A. Connecting to RS-232C The unit can be remote-controlled by connecting to PC in which terminal emulation program is built. At this time, RS-232C Cable is used for connection. When connecting to the PC by RS-232C, some keys on the PC keyboard can be used as Function Buttons on the Unit’s Front Panel. RS-232C Terminal(D-SUB 9PIN) RS-232C 9PIN(Connector Allocation) PIN NUMBER PIN SPECIFICATIONS 2 TXD(TRANSMITTEDDATA) 3 RXD(RECEIVEDDATA) 5 SG(SIGNALGROUND) 1, 4, 6~ 9

  • Samsung SDM-090, 3. Connecting to TIME LAPSE VCR When connecting the unit to the TIME LAPSE VCR, set “TLV” in “REC TYPE” after selecting “1.REC OUT SET” of SETUP MENU. 1. Connect a S-JACK cable to the VTI terminal on the Unit’s Rear Panel and to the REC TRIG OUT terminal on the VCR. 2. Connect a S-JACK cable to the ‘G’ terminal on the Unit’s Rear Panel and to the ‘G’ terminal on the VCR. 3. Connect a cable to the VCR IN terminal on the Unit’s Rear Panel and to the VCR OUT terminal on the VCR. Likewise, connect a cable to the VCR IN terminal on the Unit’s Rear Panel and to the VCR OUT terminal on the VCR. CAUTIONS Depending on the

  • 5. Setting of alarm Set operation when alarm occurs. The following screen is displayed if pressing the “ENTER” button with the blinking indication placed at the “5.ALARM SET” by pressing the “MOVE” button on the main menu screen: - The blinking character moves if pressing “ ”, “ ” button. - The setting value is changed if pressing “ ”, “ �

  • Samsung SDM-090, Name of parts and Function FRONT PANEL A. POWER SWITCH Power ON/OFF. B. MULTI SCREEN DISPLAY - MULTI SCREEN You are in the multi-screen mode. Each press of the MULTI SCREEN Button shows the picture displayed. - REC CHECK LIVE MODE: VCR output is displayed on the monitor. P.B MODE: VCR input is displayed on the monitor. This mode flashes during REC CHECK operation. - LIVE/P. B. Button for selecting either LIVE MODE or Playback MODE. LIVE MODE will be flashed. - TRIPLEX Button for selecting TRIPLEX MODE. Flashes during TRIPLEX operation. - PIP Button for selecting PICTURE-IN-PICTURE. C. CAMERA SELECT Button for selecting proper CHANNEL. D. ALARM - RE

  • Samsung SDM-090, Digital Multiplexer 3-1 CHAPTER 3. Connecting to Other Devices This unit can be connected to other devices such as monitor, camera, VCR, and PC. This chapter describes how to connect the unit to other devices. CAUTIONS Be sure that voltages higher than 2 VDC should not be input to the input terminal of Camera and Video. 1. Connecting to normal VCR and Monitor When connecting to a normal VCR, Select ‘NOR’ in “REC TYPE” of “1. REC OUT SET” in SETUP MENU. 1. Connect a BNC cable to the VCR IN terminal on the Unit Rear Panel and to the OUT terminal of the VCR. 2. Connect a BNC cable to the V

  • Digital Multiplexer ii IMPORTANT SAFEGUARDS 1. Read instructions: All the safety and operating instructions should be read before the appliance is operated. 2. Retain instructions: The safety and operating instructions should be retained for future reference. 3. Heed warnings: All warnings on the appliance and in the operating instructions should be adhered to. 4. Follow inst

  • Samsung SDM-090, When desiring to see in the FULL screen The FULL screen may be seen in the live and tape replay mode, available for 9 channels from No.1 through No.9. ➢ Method to use. Press the camera select button of the desired channel. ➢ The camera select button does not operate in the following cases: - In setting of program mode - In displaying ALARM/LOSS LIST on screen - In setting FREEZE in the division screen - In resetting of channel in the division screen When desiring to see in the division screen The division screen may be seen in the live replay mode and triplex mode and the division mode of 2, 4, 7, 9 e

  • Samsung SDM-090, Digital Multiplexer 4-1 Chapter 4. Basic Method to use Initial operation 1.Turn on power switch. A 4-division screen appears on the monitor if firstly operating after purchase. In this case, the channel with- out inputting appears in the blue background on the screen and a video loss occurs. (The current operation status is memorized when the power turns off after completing the initial setting and thus the unit operates in the operation status when the power turns off if turning power on.) 2. Setup a recording channel. Set the channel withou

  • Samsung SDM-090, Chapter 5. Setting of Program Menu <MAIN MENU> The following main menu is displayed on the monitor screen if pressing “MENU” button, the “MENU” LED turns on. The LED turns off if pressing the button and it returns to the previous status. < SUB MENU> - Select item 1~6 of the main menu using the “MOVE” button ( , ). - Press the “ENTER” button to move to the sub-menu. 1.Record setting of each camera You can set record mode and record duty, ON/OFF, reservation of each channel.The following screen is displayed on

  • Samsung SDM-090, CHAPTER 5. SETTING OF PROGRAM MENU .................... 5-1~ 5-9 Record setting of each camera........................................................................5-1 Setting of display mode....................................................................................5-3 Setting of title by channel.................................................................................5-5 Setting of display mode for current time, year, month and date .....................5-6 Setting of alarm................................................................................................5-7 System setting............................................................................

Related Products and Documents (Multiplexer):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 US Robotics USR8001 Quick installation manual us-robotics/usr8001-DTZ.pdf 03 Feb 2024 66 1.35 Mb
2 Westone Universal Monitor Operation & user’s manual westone/universal-monitor-9T9.pdf 10 Dec 2022 6 0.16 Mb
3 Singer 147-121 Instructions for using manual singer/147-121-4N3.pdf 30 Aug 2022 10 0.52 Mb
4 BMW 325 1986 Electrical troubleshooting manual bmw/325-1986-13R.pdf 11 Jan 2023 125 21.96 Mb
5 Nikon Zoom-Nikkor 35-105mm f/3.5-4.5 Instruction manual nikon/zoom-nikkor-35-105mm-f-3-5-4-5-522.pdf 27 Aug 2023 40
6 Zanussi ZFC 77/31 FF Instruction booklet zanussi/zfc-77-31-ff-638.pdf 03 Dec 2022 20 1.23 Mb

Similar Resources:

  • Comnet

    FVT401

    (4 pages)
    INS_FVT/FVR401_REV–03/01/12PAGE 1INSTALLATION AND OPERATION MANUAL FVT/FVR4014-CHANNEL DIGITAL VIDEO MULTIPLEXER10-BIT DIGITAL/SHORT-HAULThe ComNet™ FVT/FVR401 multiplexer simultaneously transmits four channels of video over one optical fiber utilizing state-of-the-art 10-bit digital encoding and decoding for high-quality video transmission that meets th …
  • Viessmann

    5229

    (16 pages)
    GebrauchsanleitungManual5229Multiplexerfür Lichtsignale mit Multiplex-TechnologieMultiplexerfor daylight signals with multiplex-technology1. Wichtige Hinweise ...................................... 22. Einführung / Eigenschaften ........................ 23. Anschluss ................................................... 34. Kon guration …
  • Siemens

    DF8000

    (46 pages)
    DF8000 Input / Output Multiplexing System Installation Function & Configuration Commissioning Safety Regulations Fire Safety & Security ProductsBuilding Technologies …
  • Moog

    Focal 903

    (96 pages)
    MOOG PROPRIETARY AND CONFIDENTIAL INFORMATION THIS TECHNICAL DATA/DRAWING/DOCUMENT CONTAINS INFORMATION THAT IS PROPRIETARY TO, AND IS THE EXPRESS PROPERTY OF MOOG INC., OR MOOG INC. SUBSIDIARIES EXCEPT AS EXPRESSLY GRANTED BY CONTRACT OR BY OPERATION OF LAW AND IS RESTRICTED TO USE BY ONLY MOOG EMPLOYEES AND OTHER PERSONS AUTHORIZED IN WRITING BY MOOG OR …
  • Renu Electronics

    FP4101 Series

    (2 pages)
    Power (Base) 24VDC(+20%, -15%), 250mA, 6W (for T-E module) 24VDC (+20%, - 15%), 270mA, 6.48W (for TN-E module) Power (with 5 Expansions) 24VDC(+20%, -15%), 500mA, 12W (for T-E module) 24VDC(+20%, -15%), 520mA, 12.48W (for TN-E module) Display 10.1”, 1024 x 600pixels, WVGA color TFT with 4-wire analog resistive touch screen LEDs 1 RAM Mem …
  • IRT Electronics

    MMM-4230

    (23 pages)
    4230-mmm & 4230-mmx.ib.rev4.doc Page 1 of 17 17/10/2007 IRT Eurocard Types MMM-4230 & MMX-4230 4 Channel ASI to G.703 Multiplexer / De-Multiplexer I R T Electronics Pty Ltd A.B.N. 35 000 832 575 26 Hotham Parade, ARTARMON N.S.W. 2064 AUSTRALIA National: Phone: (02) 9439 3744 Fax: (02) 9439 7439 International: +61 2 9439 3744 +61 2 …

Comments, Questions and Opinions: