Text of Fortinet FortiGate FortiGate-5001A User Guide:

  • Fortinet FortiGate FortiGate-5001A, FortiGate-5000 Series Hardware Guide 38 01-00000-0293-20060315 Inserting FortiGate-5000 and FortiSwitch-5000 modules into a FortiGate-5050 chassis FortiGate-5050 chassis 1 Attach the ESD wrist strap to your wrist and to an ESD socket or to a bare metal surface on the chassis or frame. 2 Loosen the screws and remove the protection plate. 3 Insert the black -48V and red RTN wires through the power wire fixture (see Figure 23). 4 Connect the black -48V power wire from the FortiGate-5053 power converter tray

  • Fortinet FortiGate FortiGate-5001A, FortiGate-5000 Series Hardware Guide 68 01-00000-0293-20060315 Inserting a FortiGate-5001FA2 module into a chassis FortiGate-5001FA2 security system 7 Turn both extraction levers to their fully-closed positions. The extraction levers should hook into the sides of the chassis slot. Closing the extraction levers draws the FortiGate-5001FA2 module into place in the chassis slot and into contact with the chassis backplane. The FortiGate-5001FA2 front panel should be in contact with the chassis front panel. When the extraction levers are fully-closed

  • Fortinet FortiGate FortiGate-5001A, FortiGate-5000 Series Hardware Guide 30 01-00000-0293-20060315 Connecting the FortiGate-5050 chassis to Data Center DC power and Data Center ground FortiGate-5050 chassis The FortiGate-5140 chassis must be mounted in a standard 19-inch rack. The chassis requires 5U of vertical space in the rack. If you install the FortiGate-5050 chassis in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient temperature. Make sure the operating ambient temperature does not exceed the manufacturer's maximum rated a

  • Fortinet FortiGate FortiGate-5001A, FortiGate-5000 Series Hardware Guide 86 01-00000-0293-20060315 Front panel LEDs and connectors FortiSwitch-5003 module Front panel LEDs and connectors From the FortiSwitch-5003 font panel you can view the status of the module LEDs to verify that the module is functioning normally. You also connect the FortiSwitch-5003 module in one chassis to a FortiSwitch-5003 module in another chassis through the front panel ethernet connections. The front panel also includes and out of band management ethernet interface and the RJ-45 console port for connecting to the FortiSwitch-5003 CLI. Figure 40: FortiSwitch-5003 front panel LEDs Tabl

  • FortiGate-5000 Series Hardware Guide 8 01-00000-0293-20060315 About the FortiGate-5000 series modules Introduction FortiGate-5020 chassis You can install one or two FortiGate-5000 series modules in the two slots of the FortiGate-5020 ATCA chassis. The FortiGate-5020 is a 4U chassis that contains two redundant AC to DC power supplies that connect to AC powe

  • FortiGate-5000 Series Hardware Guide 92 01-00000-0293-20060315 Troubleshooting FortiSwitch-5003 module 7 Carefully slide the module completely out of the slot. Troubleshooting This section describes the following troubleshooting topics: • FortiSwitch-5003 does not startup FortiSwitch-5003 does not startup Positioning of FortiSwitch-5003 extraction levers may prevent a

  • Fortinet FortiGate FortiGate-5001A, FortiGate-5140 chassis FortiGate-5140 chassis back panel FortiGate-5000 Series Hardware Guide 01-00000-0293-20060315 13 FortiGate-5140 chassis back panel Figure 2 shows the back panel of the FortiGate-5140 chassis. The back panel includes two hot-swappable redundant -48V/-60 VDC power entry modules (PEMs) labelled PEM A and PEM B. Fortinet ships the FortiGate-5140 chassis with PEM A and PEM B installed. The PEMs provide redundant DC power connections for the FortiGate-5140 chassis and distribute DC power to

  • Fortinet FortiGate FortiGate-5001A, FortiGate-5000 Series Hardware Guide 18 01-00000-0293-20060315 Connecting the FortiGate-5140 chassis to AC power using the FortiGate-5053 power converter tray FortiGate-5140 chassis To connect the FortiGate-5140 chassis to Data Center ground You need the following tools and equipment to connect the FortiGate-5140 chassis to ground: • A number 2 Phillips screwdriver. • An electrostatic discharge (ESD) preventive wrist or ankle strap with connection cord. • Two green AWG-14 stranded wires with terminal lugs attached. Figure 4: Connecting a

  • Fortinet FortiGate FortiGate-5001A, FortiGate-5020 chassis FortiGate-5020 front panel FortiGate-5000 Series Hardware Guide 01-00000-0293-20060315 41 FortiGate-5020 chassis The FortiGate-5020 chassis is a 4U 19-inch rack mount ATCA chassis that includes two slots to install up to two FortiGate-5000 series modules. You can install the same or different FortiGate modules in each slot. If both slots contain FortiGate-5001SX modules, the FortiGate-5020 chassis provides a total of 16 Gigabit ethernet FortiGate interfaces. If you install the same FortiGate-5000 series module in both slots, you can configure the modules to operate as an H

  • Fortinet FortiGate FortiGate-5001A, FortiGate-5000 Series Hardware Guide 24 01-00000-0293-20060315 Connecting the FortiGate-5140 chassis to AC power using the FortiGate-5053 power converter tray FortiGate-5140 chassis 1 Attach the ESD wrist strap to your wrist and to an ESD socket or to a bare metal surface on the chassis or frame. 2 Loosen the screws and remove the protection plate from the FortiGate-5140 PEM. 3 Connect the wires. For example, to connect power zone 3 (see Figure 11): • Connect a black DC power wire from the FortiGate-5053 power converter tray V- termi

  • Fortinet FortiGate FortiGate-5001A, FortiGate-5000 Series Hardware Guide 4 01-00000-0293-20060315 Contents FortiGate-5050 chassis.................................................................... 27 FortiGate-5050 front panel.............................................................................. 27 FortiGate-5050 back panel.............................................................................. 28 Physical description of the FortiGate-5050 chassis .................................... 29 Mounting the FortiGate-5050 chassis............................................................ 29 Air flow ........................................................................

  • Fortinet FortiGate FortiGate-5001A, FortiGate-5140 chassis Connecting the FortiGate-5140 chassis to AC power using the FortiGate-5053 power converter tray FortiGate-5000 Series Hardware Guide 01-00000-0293-20060315 23 Connecting a FortiGate-5140 chassis to the FortiGate-5053 power converter tray To use a FortiGate-5053 power converter tray with the FortiGate-5140 chassis you need to make DC power connections between the FortiGate-5140 chassis and the FortiGate-5053 power converter tray. You also need to the connect the FortiGate-5140 chassis to Data Center ground. If you are connecting both PEMs

  • Fortinet FortiGate FortiGate-5001A, FortiGate-5140 chassis Connecting a FortiGate-5140 chassis to Data Center DC power and Data Center ground FortiGate-5000 Series Hardware Guide 01-00000-0293-20060315 17 Figure 3: Connecting a FortiGate-5140 PEM to Data Center DC power 1 Attach the ESD wrist strap to your wrist and to an ESD socket or to a bare metal surface on the chassis or frame. 2 Loosen the screws and remove the protection plate. 3 Connect the power wires. For example, to connect power zones 1 and 2 (see Figure 3): • Connect a black -4

  • Fortinet FortiGate FortiGate-5001A, FortiGate-5002FB2 security system Troubleshooting FortiGate-5000 Series Hardware Guide 01-00000-0293-20060315 83 FortiGate-5002FB2 does not startup Positioning of FortiGate-5002FB2 extraction levers may prevent a FortiGate-5002FB2 module for starting up correctly. All chassis: left extraction lever not contacting power switch The left extraction lever activates the FortiGate-5002FB2 module power switch. Figure 39: Location of FortiGate-5002FB2 power switch If the left extraction lever is damaged or positioned incorrectly the FortiGate-5002FB2 module does not receive power and will not

  • FortiGate-5000 Series Hardware Guide 58 01-00000-0293-20060315 Troubleshooting FortiGate-5001SX security system If the shelf manager is not installed or not operating correctly, when you insert a FortiGate-5001SX module, the module attempts to communicate with the shelf manager. If the FortiGate-5001SX module cannot communicate with the shelf manager, the module will

  • FortiGate-5140 chassis Connecting a FortiGate-5140 chassis to Data Center DC power and Data Center ground FortiGate-5000 Series Hardware Guide 01-00000-0293-20060315 15 Connecting a FortiGate-5140 chassis to Data Center DC power and Data Center ground Connect the FortiGate-5140 chassis to Data Center DC power (also called battery power) using the redundant power entry modules (PEMs). Forti

  • Fortinet FortiGate FortiGate-5001A, Introduction Warnings and cautions FortiGate-5000 Series Hardware Guide 01-00000-0293-20060315 9 Warnings and cautions Only trained and qualified personnel should be allowed to install or maintain FortiGate-5000 series hardware. Read and comply with all warnings, cautions and notices in this document. • Turning off all power switches may not turn off all power to the FortiGate unit. Disconnect the FortiGate unit from its power source, telecommunications links and networks before installing, removing FortiGate components, or performing other maintenance task

  • Fortinet FortiGate FortiGate-5001A, FortiGate-5000 Series Hardware Guide 42 01-00000-0293-20060315 FortiGate-5020 back panel FortiGate-5020 chassis Figure 24: FortiGate-5020 front panel with two FortiGate-5001SX modules FortiGate-5020 back panel Figure 25 shows the back of a FortiGate-5020 chassis. The chassis back panel includes two redundant AC power connectors and provides access to the hot swappable cooling fan tray. Each AC power connector includes a 25 Amp circuit breaker that also functions as the on/off switch for the AC power connector. You can use the power wire fixtures to secure AC power wires to prevent the power wires from being accidently disconnected. Figure 25: FortiGate-5020 chassis back pane

  • Fortinet FortiGate FortiGate-5001A, FortiGate-5000 Series Hardware Guide 22 01-00000-0293-20060315 Connecting the FortiGate-5140 chassis to AC power using the FortiGate-5053 power converter tray FortiGate-5140 chassis Figure 9: Redundant FortiGate-5053 power converter trays Figure 10: Redundant FortiGate-5053 power converter trays and 2 + 1 redundant FortiGate-5140 power supplies PWR ACC STA IPM CONSOLE USB 1 2 3 4 5 6 7 8 PWR ACC STA IPM CONSOLE USB 1 2 3 4 5 6 7 8 PWR ACC STA IPM CONSOLE USB 1 2 3 4 5 6 7 8 PWR ACC STA IPM CONSOLE USB 1 2 3 4 5 6 7 8 PWR ACC STA IPM CONSOLE USB 1 2 3 4 5 6 7 8 PWR ACC STA IPM CONSOLE USB 1 2 3 4 5 6 7 8 PWR ACC STA IPM CONSOLE USB 1

  • Fortinet FortiGate FortiGate-5001A, FortiGate-5050 chassis Connecting the FortiGate-5050 chassis to AC power using the FortiGate-5053 power converter tray FortiGate-5000 Series Hardware Guide 01-00000-0293-20060315 33 Figure 17: Front panel of the FortiGate-5053 power converter tray with one power supply removed The back panel of the FortiGate-5053 (shown in Figure 18) includes one DC power connector terminal consisting of a RTN connector and a -48VDC connector. The -48VDC connector is labelled -V. The RTN connector is not labelled. Figure 18: Back panel of the FortiGate-5053 power converter tray The back panel also includes three AC power connectors numb

Related Products and Documents (Network Router):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Philips 14PT1686/01P Product manual philips/14pt168601p-KQ3.pdf 15 Mar 2023 16
2 Black & Decker DIGITAL ADVANTAGE D2000 Use and care book manual black-decker/digital-advantage-d2000-325.pdf 11 Sep 2023 13 0.35 Mb
3 Yamaha WR250F(W) Owner's service manual yamaha/wr250f-w-56M.pdf 09 Apr 2023 912 25.2 Mb
4 Cisco 6921 Administration manual cisco/6921-RU3.pdf 13 Dec 2022 14 0.26 Mb
5 Poulan Pro 530164603 Instruction manual poulan-pro/530164603-3SI.pdf 16 Mar 2023 18
6 C-SCOPE CS440XD Manual  c-scope/cs440xd-513.pdf 20 Jan 2024 4

Similar Resources:

  • Intellinet

    525268

    (3 pages)
    Wireless 300N Dual-Band Router300 Mbps Wireless 802.11a/b/g/n, 2.4 + 5 GHz, 2T2R MIMO, QoS, 4-Port LAN SwitchPart No.: 525268Wireless 300N Dual-Band Router - The Ultimate in Wireless PerformanceThe Intellinet Wireless 300N Dual-Band Router, model 525268, is the latest in wireless networkingtechnology. Wireless bandwidth never peaked higher and wireless s …
  • D-Link

    DVG-7044S

    (7 pages)
    ©2005 D-Link Systems, Inc. All rights reserved. Trademarks or registered trademarks are the property of their respective holders. Software and specifications subject to change without notice. DVG-7044S FXS+FXO VoIP Router Before You Begin You must have at least the following: ‧ A subscription with bundled service provider included in this package � …
  • Comset

    CM950W

    (111 pages)
    CM950W User Manual 1 www.comset.com.au Industrial 5G Router CM950W User Manual Comset: 37/ 125 Highbury R …
  • Nortel

    Passport 8600 Series

    (150 pages)
    Nortel Ethernet Routing Switch 8600Installing Ethernet RoutingSwitch 8600 ModulesATTENTIONClicking on a PDF hyperlink takes you to the appropriate page. If necessary,scroll up or down the page to see the beginning of the referenced section.NN46205-304 312749-K Rev 02. …
  • Panasonic

    PN28160A

    (165 pages)
    1  Thank you for purchasing our product.  This manual provides important information about safe and proper operations of this Switching Hub.  Please read the "Important Safety Instruction" on pages 2 to 3.  Any problems or damage resulting from disassembly of this Switching Hub by customers are not covered by the warranty. …
  • NETGEAR

    FVX538v2 - ProSafe VPN Firewall Dual WAN

    (3 pages)
    Application Note Generating a Self Certificate Request Using OpenSSL for an FVX538 or FVS338 ProSafe® VPN Firewall Summary This application note describes how to configure a self certificate request (CSR) on one WAN interface of a NETGEAR FVX538 or FVS338 ProSafe VPN Firewall using OpenSSL to create the certificate authority. The procedure is the same fo …

Comments, Questions and Opinions: