Manualios.com

Samsung SSA-P102 Operation & User’s Manual

Samsung SSA-P102 Manual Online:

4.3, 773 votes
Samsung SSA-P102 User Manual
Samsung SSA-P102 User Guide
Samsung SSA-P102 Online Manual

Text of Samsung SSA-P102 User Guide:

  • Samsung SSA-P102, Access Control Panel user manual SSA-P102 SSA-P102T imagine the possibilities Thank you for purchasing this Samsung product. To receive more complete service, please visit our website. www.samsungsecurity.com

  • Samsung SSA-P102, 2_ safety information safety information CAUTION RISK OF ELECTRIC SHOCK. DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK) NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. This symbol indicates that dangerous voltage consisting a risk of electric shock is present within this unit. This exclamation point symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. WARNING To reduce the risk of fi re or electric shock, do not expose this appliance to rain or moisture. WARNING

  • Samsung SSA-P102, English _ 3 SAFETY INFORMATION Keep out of direct sunlight and heat radiation sources. It may cause fi re. Install it in a place with good ventilation. Avoid aiming the controller directly towards extremely bright objects such as sun. Apparatus shall not be exposed to dripping or splashing and no objects fi lled with liquids, such as vases, shall be placed on the apparatus. The Mains plug is used as a disconnect device and shall stay readily operable at any time. FCC Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions

  • Samsung SSA-P102, 4_ contents contents PRODUCT INTRODUCTION 5 5 FeatureS 6 What’s included 9 Cable Selection INSTALLATION AND EXTERNAL CONNECTION 10 10 Connecting the termination resistor and diode 11 Earth-grounding the communication cables 12 Power, Reader, and I/O Connection 15 Communication Line Connection INITIALIZATION 19 19 System Initialization 19 Reader Input Bit Setup 20 Board ID Setting 20 Communication Speed Setup TROUBLESHOOTING 21 21 Troubleshooting PRODUCT SPECIFICATIONS 23 23 Product Specifi cations

  • English _ 5 PRODUCT INTRODUCTION FEATURES This is a state-of-the-art single door access controller device that provides a high level security system in an affordable price, meeting the needs in the security industry. With its user-friendly interface, this product enables user manipulation easy and simple for whatever you want to perform in a high level of s

  • Samsung SSA-P102, 6_ product introduction product introduction Time Scheduling You can specify a time range during which a specifi c operation is performed. You can specify a specifi c time range for a schedule code, which will be transferred to the applicable device. You can specify up to 5 different time ranges for a day, ranging from Monday to Sunday including holidays. Each time schedule code can be applied with a single different (or same) holiday code. Door Open Alarm and Forced Door Open Alarm The Door Open Alarm function notifi es the administrator that the door is still

  • English _ 7 PRODUCT INTRODUCTION Main Board 1 Fixing Hole Used to attach SSA-P102 to the closure using a metal supporter. (Ensure that you use the metal supporter to prevent the EMI.) 2 2Pin DIP Switch Used to set the type of a connected reader to either 26bit Wiegand or 34bit Wiegand. 3 8Pin DIP Switch The device address and communication speed specifi ed by th

  • Samsung SSA-P102, 8_ product introduction product introduction 10 Input #3 Input Port: The fl ashing LED indicator denotes that a signal is sensed by the port. 11 Input #2 Input Port: The fl ashing LED indicator denotes that a signal is sensed by the port. (connected to the Door Contact Sensor.) All other sensors are not allowed. 12 Input #1 Input Port: The fl ashing LED indicator denotes that a signal is sensed by the port. (connected to the Exit button.) All other input sources are not allowed. 13 MCU Module Connection Port MCU module connection port. Do not disass

  • Samsung SSA-P102, English _ 9 PRODUCT INTRODUCTION CABLE SELECTION Item Cable Type 1 DC 12V Product Power  This product Belden #9409, 18 AWG 2 Conductor, Unshielded 2 Reader (Power and Data) External Reader  This product Belden #9512, 22 AWG 4 Conductor, Shielded Belden #9514, 22 AWG 8 Conductor, Shielded 3 Door Contact Sensor Exit Button Sensor Input Input  This product Belden #9512, 22 AWG 4 Conductor, Shielded Belden #9514, 22 AWG 8 Conductor, Shielded 4 Door Lock Alarm Device Lock (Alarm)  This product Belden #9409, 18AWG 2 Conductor, Unshielded 5 RS-232 Cable Converter  Host P.C. Belden #9829, 24 AWG 2-twisted pair, Shie

  • Samsung SSA-P102, 10_ installation and external connection installation and external connection CONNECTING THE TERMINATION RESISTOR AND DIODE Termination Resistor A resistor is inserted for matching the line’s impedance to prevent distortion and reduction in RS-422 or RS-485 long distance data communications, which is referred to as termination resistor. Note that termination resistors of lower than 90 are not allowed, neither more than one termination resistor is accepted for the communications system. Bypass Diode Connection If y

  • Samsung SSA-P102, English _ 11 INSTALLATION AND EXTERNAL CONNECTION EARTH-GROUNDING THE COMMUNICATION CABLES We recommend you to use a proper grounding system for the communication cables. The best grounding method is to earth-ground the shield wire of the communication cable. However, the earth-grounding of the communication cable is not easy at all, and it also causes an increased installation cost. There are three grounding points available for installation: 1. Earth Ground 2. Chassis Ground 3. Power Ground The most important thing about t

  • Samsung SSA-P102, 12_ installation and external connection installation and external connection POWER, READER, AND I/O CONNECTION Power Connection Check the location of the power port. - Connect the plus (+) line of DC 12V to the corresponding port (+12V). - Connect the plus (-) line of DC 12V to the GND (-) port. Reader Connection - You can safely use other power sources for the reader than supplied from the specifi ed port; however, all power sources should be connected to the common GND port. Failure of the GND grounding will cause a transfer error of Wigand data to the controller due to a voltage difference. Connect Wiegand Data Output 0 of the proximity reader

  • English _ 13 INSTALLATION AND EXTERNAL CONNECTION Input Connection - The Input #1 and Input #2 ports have the Exit button and the Door Contact Sensor installed, while Input #3 to Input #5 can be confi gured to your preference. - Exit Button Connection Connect one line of the Exit button to IN 1. Connect the other line of the Exit button to GND. - Door Contact Sensor Connection

  • 14_ installation and external connection installation and external connection Output Connection - According to the operation mode, the Door Lock type is classifi ed in two: NC (Normal close) and NO (Normal Open). Make the connection as appropriate. - To prevent a risk of voltage surge during the lock operation, it is recommended to use the bypass diode. - If the Door Lock type is POWER FAIL S

  • English _ 15 INSTALLATION AND EXTERNAL CONNECTION COMMUNICATION LINE CONNECTION RS-232 Communication Port Connection A 9-pin connector for serial communication is required to make connection to the PC. Connect the 9 pin connector for RS-232 communications as follows: Connect RS-232-TX to pin #2 of the 9-pin connector. Connect RS-232-TX to pin #3 of the 9-pin connector. Con

  • Samsung SSA-P102, 16_ installation and external connection installation and external connection RS-422 Communication Port Connection (Standalone) The RS-422/RS-232 converter is required to establish RS-422 communications. Connect the 9-pin connector of the RS-422/RS-232 converter as follows: Connect RS-422-TX(-) to the RX(-) port of the converter. Connect RS-422-TX(+) to the RX(+) port of the converter. Connect RS-422-RX(-) to the TX(-) port of the converter. Connect RS-422-RX(+) to the TX(+) port of the converter. Connect the 9-pin connector of the RS-422/RS-232 converter to the serial COM port of the computer.

  • Samsung SSA-P102, English _ 17 INSTALLATION AND EXTERNAL CONNECTION RS-422 Communication Port Connection (Multiple Units) The RS-422/RS-232 converter is required to establish RS-422 communications with SSA-P102. - Follow the guidelines below to make connection between devices. Connect TX(-) of one device to TX(-) of other one. Connect TX(+) of one device to TX(+) of other one. Connect RX(-) of one device to RX(-) of other one. Connect RX(+) of one device to RX(+) of other one. Set a unique board ID for each product. - Fol

  • Samsung SSA-P102, 18_ installation and external connection installation and external connection TCP/IP Communication Port Connection 1) TCP/IP Communication Connection SSA-P102T is required to establish TCP/IP communications. 2) Cabling Connect the LAN cable to the TCP/IP RJ-45 jack as shown. Connect the RJ45 jack of the unit to the RJ45 plug, the LAN cable of the network system. Set a unique communication address (COMM ADDR) for each unit Install and launch the application (SAMS). J  1. 2. 3. PC TCP / IP TCP / IP HUB

  • Samsung SSA-P102, English _ 19 INITIALIZATION Initialization SYSTEM INITIALIZATION Initializing the system using the Initialize switch Apply the power and initialize the system by using the initialization switch. Locate the Initialize switch ( ) on the upper right corner and press both switches simultaneously. Pressing both of the switches at the same time for about 2 seconds will sound initialization ready beep. Releasing both switches will stop the beep, and restarts the system after the initialization. Initializing the system restores all your settin

  • Samsung SSA-P102, 20_ initialization initialization BOARD ID SETTING Each device in the multi-serial communication connection is assigned with a unique number to identify each other. The initial value of the switch is “0”, and all of the 8 switches are defaulted to OFF. Each switch has a unique value, and the board ID is the sum of the values of the switches. You can specify a value between 0 and 31 for the board ID. Refer to the example below for the board ID. Example 1 Example 2 Example 3 1 2 4 8 16 9600 bps KS022H ON 12345678 1 2 4 8 16 38400 bps KS022H ON 12345678 1 2 4 8 16 115200 bps KS022H ON 12345678 Board ID: 0 (default) Board ID: 2+4 = 6 Board ID: 1+16 = 17 The board ID becomes the addr

  • Samsung SSA-P102, English _ 21 TROUBLESHOOTING troubleshooting TROUBLESHOOTING If the product does not function properly, please see the below for trouble shooting. If the trouble persists, please contact the SAMSUNG Customer Service near you. Problem Action Can I specify RF only or RF+P/W mode differently according to the card? 1) It is not available. 2) The mode is defi ned for each reader device, not the card. Thus, you can not specify the mode for each card differently. Ever since I mass-transferred data using the PC application, some cards are not allowed for access. 1) You might have not saved card information to the PC, but just to the

  • Samsung SSA-P102, 22_ troubleshooting troubleshooting The reader reads a card normally but no reaction is made to SSA-P102 or an irrelevant card number is displayed. 1) Check the power source of the reader. (Check if the LED indicator of the reader is blinking when it has read a card.) 2) Check if the reader works properly. (Disconnect the reader from the system and use a measuring device such as an oscilloscope to measure the output port of the reader.) 3) Check if the reader is properly connected to the system

  • Samsung SSA-P102, English _ 23 product specifi cations PRODUCT SPECIFICATIONS Item SSA-P102 SSA-P102T Users 10,000 ~ 50,000 Users (Default: 10,000) Event Buffer 50,000 ~ 100,000(Default: 50,000) Power / Current DC 12V / Max.120mA Reader Port 2ea : 26bit/ 34bit Wiegand(Selectable), 4 / 8bit Burst for PIN Door Open Time 00~99 Sec. (Default 3Sec.) Communication RS232 / RS422 / RS485 RS232 / RS422 / RS485 / TCP/IP Baud Rate(bps) 4800/ 9,600/ 19,200/ 38,400/ 57,600(default)/ 115,200(selectable) Input Port 5ea : Exit Button, Door Sensor, Au

  • Samsung SSA-P102, AB82-02555A Correct disposal of batteries in this product (Applicable in the European Union and other European countries with separate battery return systems.) This marking on the battery, manual or packaging indicates that the batteries in this product should not be disposed of with other household waste at the end of their working life. Where marked, the chemical symbols Hg, Cd or Pb indicate that the battery contains mercury, cadmium or lead above the reference levels in EC Directive 2006/66. If

Related Products and Documents (Security System):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Marantz SR4400 Operation & user’s manual marantz/sr4400-J47.pdf 20 Sep 2023 37
2 Quidel Sofia Operation & user’s manual quidel/sofia-NOL.pdf 11 Jan 2023 58
3 VDO Cyclecomputing MC1.0 Instruction manual vdo-cyclecomputing/mc1-0-OCE.pdf 01 Mar 2023 37 0.88 Mb
4 IBM PC 300GL Software manual ibm/pc-300gl-97Z.pdf 23 Jun 2023 46
5 PSG 15 Kw Installation and operating instructions manual psg/15-kw-QN9.pdf 16 Oct 2022 37
6 Advantech AIMB-760 Startup manual advantech/aimb-760-L61.pdf 21 Aug 2022 3

Similar Resources:

  • Panasonic

    BB-HCS301A - Network Camera Server

    (4 pages)
    2005 Panasonic Communications Co., Ltd. All Rights Reserved.PSQX3859ZB KK0605YT2056Getting StartedNetwork Camera ServerModel No.BB-HCS301A•Please read the Installation manual before using. •This Getting Started explains how to connect and set up this product.See the Operating Instructions on the Setup CD-ROM for details about the features.•If you cann …
  • ADT

    Security Manager 3000EN

    (32 pages)
    Safewatch Pro Safewatch Pro Safewatch Pro Safewatch Pro ® 3000EN3000EN3000EN3000EN Entrepreneur 3000ENEntrepreneur 3000ENEntrepreneur 3000ENEntrepreneur 3000EN Security Manager 3000ENSecurity Manager 3000ENSecurity Manager 3000ENSecurity Manager 3000EN Security SystemsSecurity SystemsSecurity SystemsSecurity Systems Programming Guide an …
  • Telguard

    TG-4

    (27 pages)
    56033504 © 2007 Telular Corporation TELGUARD® DIGITAL TG-4 Residential Primary & Small Business Cellular Alarm Communicator Cellular Alarm Transmission System Using GSM Digital Cellular Technology P/N: TG4G0001 INSTALLATION AND OPERATING INSTRUCTIONS For use by TELGUARD® customers only. Distribution to others strictly prohibited. COMPANY …
  • Toa

    N-8000 SERIES

    (503 pages)
    OPERATING INSTRUCTIONSPACKET INTERCOM SYSTEMN-8000 SERIESThank you for purchasing TOA's Packet Intercom system. Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment. …
  • DSC

    Power632

    (52 pages)
    Installation ManualWARNINGThis manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully read.This panel will not operate if installed outside of North America. See section 1.1 for details.PC1555MXSoftware Version 2.3DLS-3 v1.3 an …
  • GeoVision

    GV-NVR System Lite V2 Series

    (29 pages)
    Quick Start GuideQuick Start GuideGV-NVR System Lite V2 (Rev. B)The Vision of SecurityRoHSThank you for purchasing GV-NVR System Lite V2. This guide is designed to assist the new user in getting immediate results from the GV-NVR System Lite V2. For advanced information on how to use the GV-NVR System Lite V2, please refer to GV-NVR System Lite V2 User's …

Comments, Questions and Opinions: