Manualios.com

Ultra Start KE-6 Install Manual

Ultra Start KE-6 Manual Online:

4.25, 2856 votes
Ultra Start KE-6 User Manual
Ultra Start KE-6 User Guide
Ultra Start KE-6 Online Manual

Text of Ultra Start KE-6 User Guide:

  • KE-6 REV.2009.04.10 ADVANCED KEYLESS ENTRY SYSTEM INSTALL GUIDE TM FCC ID NOTICE This device complies with Part 15 of the FCC rules. Operation is subject to the following conditions: 1. This device may not cause harmful interference, and 2.This device must accept any interference received, including interference that may cause undesired operation. CAUTION: Changes o

  • Ultra Start KE-6, Wire Diagram..................................................................Page 3 Quick View Programing Chart.......................................Page 4 Program Menu 1 Page 4 Program Menu 2 Page 4 Transmitter Programming.............................................Page 5 System Wiring................................................................Page 6-9 10 Pin Connector Page 6-7 3 Pin Power Connector Page 6-7 Door Lock Connector Page 8-9 Entering Program Mode................................................Page 8 System Reset.................................................................Page 9 System Programming....................................

  • Ultra Start KE-6, Wire Diagram..................................................................Page 3 Quick View Programing Chart.......................................Page 4 Program Menu 1 Page 4 Program Menu 2 Page 4 Transmitter Programming.............................................Page 5 System Wiring................................................................Page 6-9 10 Pin Connector Page 6-7 3 Pin Power Connector Page 6-7 Door Lock Connector Page 8-9 Entering Program Mode................................................Page 8 System Reset...............................

  • Ultra Start KE-6, SETTING # LED FLASHES 1 2 3 VALET SETTINGS SECURE VALET 15 SECONDS STANDARD VALET 8 SECONDS OPTION 3 3 HONK OPTION 1 1 HONK OPTION 2 2 HONK PARK LIGHT OUTPUT HORN/ AUX OPTIONS OPTIONS 30 SECOND ON FOR DISARM AUX OUTPUT 0.75 SEC PULSED POS TRUNK RELEASE OUTPUT AUX OUTPUT ACTIVE WHEN HELD NORMAL OPERATION HORN OUTPUT SETTING DESCRIPTION SETTING # LED FLASHES 1 2 3 4 5 6 7 IGNITION AUTO-LOCK IGNITION AUTO-LOCK & UNLOCK ENABLED IGNITION AUTO-LOCK ONLY OPTION 3 3 HONK IGNITION AUTO-LOCK DISABLED OPTION 1 1 HONK OPTION 2 2 HONK HORN SETTINGS DOOR LOCK OPTIONS DOOR LOCK PULSE TIMES HORN OUTPUT TIMING PASSIVE ARMING PASSIVE DOOR LOCKS HORN HONK DISABLED D

  • SETTING # LED FLASHES 1 2 3 VALET SETTINGS SECURE VALET 15 SECONDS STANDARD VALET 8 SECONDS OPTION 3 3 HONK OPTION 1 1 HONK OPTION 2 2 HONK PARK LIGHT OUTPUT HORN/ AUX OPTIONS OPTIONS 30 SECOND ON FOR DISARM AUX OUTPUT 0.75 SEC PULSED POS TRUNK RELEASE OUTPUT AUX OUTPUT ACTIVE WHEN HELD NORMAL OPERATION HORN OUTPUT SETTING DESCRIPTION SETTING # LED FLASHES 1 2 3 4 5 6 7 IGNITION AUTO-LOCK IGNI

  • Ultra Start KE-6, OUTPUT TO ACTIVATE SIREN (+) 2amp GRAYOUTPUT FOR TRUNK RELEASE (-) OUTPUT TO ACTIVATE HORN/ AUX (-) STARTER DISABLE (-) WHEN LOCKED DOME LIGHT (-) WHEN DISARMED (30sec) WHT/GRNSECOND UNLOCK OUTPUT (-) BLUEN/A GREENN/A PURPLEN/A YELLOWSWITCHED IGNITION INPUT (+) WHT/BLUE ORANGE BLK/WHT BROWN WHITEPOSITIVE PARK LIGHT OUTPUT (+15amp) SYSTEM CHASSIS GROUND INPUT RED CONSTANT 12 VOLT INPUT (20AMP) BLACK 10 PIN CONNECTOR 3 PIN POWER CONNECTOR FOR MORE DETAILED INFORMATION ON PROGRAMMING, WIRING DIAGRAMS, DOOR LOCK CONFIGURATION AND OTHER INFORMATION, PLEASE VISIT WWW.ULTRASTARTERS.COM SYSTEM PROGRAMMING - Menu 1 PAGE 6 KE-6 INSTALL MANUAL

  • Ultra Start KE-6, OUTPUT TO ACTIVATE SIREN (+) 2amp GRAYOUTPUT FOR TRUNK RELEASE (-) OUTPUT TO ACTIVATE HORN/ AUX (-) STARTER DISABLE (-) WHEN LOCKED DOME LIGHT (-) WHEN DISARMED (30sec) WHT/GRNSECOND UNLOCK OUTPUT (-) BLUEN/A GREENN/A PURPLEN/A YELLOWSWITCHED IGNITION INPUT (+) WHT/BLUE ORANGE BLK/WHT BROWN WHITEPOSITIVE PARK LIGHT OUTPUT (+15amp) SYSTEM CHASSIS GROUND INPUT RED CONSTANT 12 VOLT INPUT (20AMP) BLACK 10 PIN CONNECTOR 3 PIN POWER CONNECTOR FOR MORE DETAILED INFORMATION ON PROGRAMMING, WIRING DIAGRAMS, DOOR LOCK CONFIGURATION AND OTHER INFORMATION, PLEASE VISIT WWW.ULTRASTARTERS.COM SYSTEM PROGRAMMING - Menu 1 PAGE 6 KE-6 INSTALL MANUAL SYSTEM WIRING Pin 1- Brown Wi

  • Ultra Start KE-6, 3 PIN KEYLESS CONNECTOR This connector is used when installing the optional keyless entry feature. If the door lock type of the vehicle is not negative see the following pages for the appropriate door lock diagram. Pin 1- Green Wire- Negative Lock Output Connect to lock wire from the switch on vehicles with a negative type switch. **LOW CURRENT ONLY** Pin 2- 12volt Output for Door Lock Module This output will supply 12volts for a plug-in type door lock module. Do not use this input to power-up relays **LOW CURRENT ONLY** Pin 3- Blue Wire- Negative Unlock Output Connect to lock wire from the sw

  • Ultra Start KE-6, 3 PIN KEYLESS CONNECTOR This connector is used when installing the optional keyless entry feature. If the door lock type of the vehicle is not negative see the following pages for the appropriate door lock diagram. Pin 1- Green Wire- Negative Lock Output Connect to lock wire from the switch on vehicles with a negative type switch. **LOW CURRENT ONLY** Pin 2- 12volt Output for Door Lock Module This output will supply 12volts for a plug-in type door lock module. Do not use this input to power-up relays **LOW CURRENT ONLY** Pin 3- Blue Wire- Negative Unlock Output Connect to lock wire from the switch on vehi

  • Cycle the Ignition Key ON/OFF ON/OFF ON (Leaving the key ON) Press and release the Program Switch 1 time. HORN will chip to confirm program mode entered Press Lock Button on Remote to Select Menu 1 1 HONK SETS OPTION 1 – AUTO-LOCK & UNLOCK ENABLED- The doors will lock when the key is turned on and unlock the when the key is turned off. SETS OPTION 2 – AUTO LOCK ONLY ENABLED- Th

  • Ultra Start KE-6, Cycle the Ignition Key ON/OFF ON/OFF ON (Leaving the key ON) Press and release the Program Switch 1 time. HORN will chip to confirm program mode entered Press Lock Button on Remote to Select Menu 1 1 HONK SETS OPTION 1 – AUTO-LOCK & UNLOCK ENABLED- The doors will lock when the key is turned on and unlock the when the key is turned off. SETS OPTION 2 – AUTO LOCK ONLY ENABLED- The doors will lock when the key is turned on but will not unlock when te key is turned off. SETS OPTION 3 – AUTO LOCK DISABLED- The doors will not lock or unlock when the key is turned on or off. SETS OPTION 1 – HORN DISAB

  • Ultra Start KE-6, Cycle the Ignition Key ON/OFF ON/OFF ON (Leaving the key ON) Press and release the Program Switch 1 time. HORN will chip to confirm program mode entered Press Unlock Button on Remote to Select Menu 2 1 HONK SETS OPTION 1 – SECURE VALET - The LED/ Program Switch must be held for 15 seconds to place the system into Valet Mode. SETS OPTION 2 – STANDARD VALET- The LED/ Program Switch must be held for 5 seconds to place the system into Valet Mode. SETS OPTION 1 – 30 SECOND- The park light output will flash for all functions and will stay active for 30 seconds when

  • Ultra Start KE-6, Cycle the Ignition Key ON/OFF ON/OFF ON (Leaving the key ON) Press and release the Program Switch 1 time. HORN will chip to confirm program mode entered Press Unlock Button on Remote to Select Menu 2 1 HONK SETS OPTION 1 – SECURE VALET - The LED/ Program Switch must be held for 15 seconds to place the system into Valet Mode. SETS OPTION 2 – STANDARD VALET- The LED/ Program Switch must be held for 5 seconds to place the system into Valet Mode. SETS OPTION 1 – 30 SECOND- The park light output will flash for all functions and will stay active for 30 seconds when unlock is pressed. SETS OPTION 2 – Trunk Release- The park

  • Ultra Start KE-6, SETTING # LED FLASHES 1 2 3 VALET SETTINGS TRUNK RELEASE SECURE VALET 15 SECONDS STANDARD VALET 8 SECONDS OPTION 3 3 HONK OPTION 1 1 HONK OPTION 2 2 HONK PARK LIGHT OUTPUT AUX OUTPUT AUX CHANNEL 5 OPTIONS STARTER DISABLEDOOR LOCKS 30 SECOND ON FOR DISARM AUX OUTPUT 0.75 OUTPUT POS TRUNK RELEASE OUTPUT AUX OUTPUT AS LONG AS HELD NORMAL OPERATION HORN OUTPUT (-) SETTING DESCRIPTION SETTING # LED FLASHES 1 2 3 4 5 6 7 IGNITION AUTO-LOCK AUTO-LOCK & UNLOCK ENABLED IGNITION AUTO- LOCK ONLY OPTION 3 3 HONK IGNITION AUTO- LOCK DISABLED OPTION 1 1 HONK OPTION 2 2 HONK HORN SETTINGS DOOR LOCK OPTIONS D

  • Ultra Start KE-6, SETTING # LED FLASHES 1 2 3 VALET SETTINGS TRUNK RELEASE SECURE VALET 15 SECONDS STANDARD VALET 8 SECONDS OPTION 3 3 HONK OPTION 1 1 HONK OPTION 2 2 HONK PARK LIGHT OUTPUT AUX OUTPUT AUX CHANNEL 5 OPTIONS STARTER DISABLEDOOR LOCKS 30 SECOND ON FOR DISARM AUX OUTPUT 0.75 OUTPUT POS TRUNK RELEASE OUTPUT AUX OUTPUT AS LONG AS HELD NORMAL OPERATION HORN OUTPUT (-) SETTING DESCRIPTION SETTING # LED FLASHES 1 2 3 4 5 6 7 IGNITION AUTO-LOCK AUTO-LOCK & UNLOCK ENABLED IGNITION AUTO- LOCK ONLY OPTION 3 3 HONK IGNITION AUTO- LOCK DISABLED OPTION 1 1 HONK OPTION 2 2 HONK HORN SETTINGS DOOR LOCK OPTIONS DOOR LOCK PULSE TIMES HORN OUTPUT PASSIVE ARMING PASSIVE DOOR

More Instructions:

DOWNLOAD

Related Products and Documents (Car Alarm):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Ninja CT682SP Owner's manual ninja/ct682sp-1N9.pdf 11 Mar 2024 2
2 YASKAWA SGD7C-***AMAA*** Product manual yaskawa/sgd7c-amaa-2BA.pdf 16 Nov 2022 669
3 Henkelman DT 60 Operation & user’s manual henkelman/dt-60-75S.pdf 13 Jul 2022 70
4 Palm Tungsten W Start here palm/tungsten-w-T97.pdf 10 Jun 2023 2
5 Sennheiser e835 fx Instruction manual sennheiser/e835-fx-HP8.pdf 06 Sep 2022 12 1.13 Mb
6 Toyota Corolla guide Quick reference manual toyota/corolla-guide-UHZ.pdf 17 Oct 2023 12 1.06 Mb

Similar Resources:

  • Code Alarm

    CA2LED5

    (12 pages)
    1CA2LED5 / AS9234E 4280852 Owners rev A.IMPORTANT NOTE: The operation of the Security and Convenience System as described in this manual is applicable to most vehicles. However, due to the conguration of some vehicles, some functions AND/OR SAFETY PRECAUTIONS may not apply. Please see your installing dealer for more information.PROFESSIONALSERIESOwner’ …
  • Ultra Start

    1271M

    (20 pages)
    OWNER’S GUIDEThe system must be placed into Service Mode before any service work is started on the vehicle. It is the sole responsibility of the vehicle owner to ensure that this is done. The manufacturer accepts no liability or responsibility for accidental starting of the vehicle. CARBON MONOXIDE - Never Start in an Enclosed Building (Garage, Warning!! …
  • Code Alarm

    CA611

    (21 pages)
    1CA 611 Installation InstructionsAvoid mounting components or routing wires nearhot surfacesAvoid mounting components or routing wires nearmoving partsTape or loom wires under hood for protection andappearanceUse grommets when routing wires through metalsurfacesUse a Digital Multi Meter for testing and verifyingcircuits. DO NOT USE A TEST LIGHT, OR"COM …
  • Code Alarm

    CA 420

    (4 pages)
    CA 420 Owners ManualCAUTION!Be certain that the vehicle is outdoors before using this or any re-mote vehicle starting device. A running engine produces dangerouscarbon monoxide fumes which can be harmful or fatal if prolongedexposure occurs. DO NOT remote start the vehicle if the car isgaraged …
  • Brazel's RV Performance

    UltraTrac UTF53V8R

    (3 pages)
    UTF53V8R InstructionsFord F-53 – 14,000, 16,000 & 18,000 GVW Motor Home Chassis Rear Bar Page 1 of 3Bolt Size Grade 5 Grade 81/4” 10 145/16” 19 293/8” 33 477/16” 54 781/2” 78 1195/8” 154 2303/4” 257 380Torque in Foot-Pounds for Inch Bolts Torque in Foot-Pounds for Metric Bolts Bolt Size Grade 8.8 Grade 10.96MM 6 88MM 16 2210MM 31 4012MM 5 …
  • Omega

    MARS-22

    (20 pages)
    COPYRIGHT: OMEGA RESEARCH & DEVELOPMENT 2004DELUXE KEYLESS ENTRY & REMOTE STARTERFOR AUTOMATIC TRANSMISSION VEHICLES ONLYMARS-22Products manufactured and sold by OMEGA RESEARCH & DEVELOPMENT, INC. (the Company),are warranted to be free from defects in materials and workmanship under normal use. If a productsold by the Company proves to be defect …

Comments, Questions and Opinions: