  • Frymaster 17EC, 6-2 6.2 Accessing Equipment for Servicing DANGER Moving this equipment while it is filled with hot water may cause spilling or splattering of the hot water. Always drain the cookpot before attempting to relocate this equipment for servicing. 1. Disconnect the unit from the electrical power supply and from the water supply. 2. Remove any attached restraining devices. 3. Relocate the unit for service accessibility. 4. After servicing is complete, reconnect the unit to the water supply, reattach restraining devices, and reconnect the un

  • Frymaster 17EC, 4-1 ELECTRIC COOKER MODELS 17EC, 17ECS, ESW AND EWBS CHAPTER 4: PREVENTIVE MAINTENANCE Daily Preventive Maintenance It is normal for a coating of starch to form on the elements, sensors, and temperature probes during operation. If the coating is allowed to build-up, it will adversely affect the operation of the equipment. The preventive maintenance routines below should be performed at least daily to keep your equipment functioning at peak efficiency. Inspect Equipment and Accessories for Damage Look for loose or frayed wires and cords, leaks, foreign material in cookpot or inside cabinet, and any other indications that the equipmen

  • Frymaster 17EC, 3-1 ELECTRIC COOKER MODELS 17EC, 17ECS, ESW AND EWBS CHAPTER 3: OPERATING INSTRUCTIONS 3.1 Spaghetti Magic III Controller (As Used on 17EC and 17ECS Units) 1 5432 7 8 9 6 1 Numeric Keypad 6 Skim Switch (w/Autoskim only) 2 Boil Mode Indicator 7 Timer Start Switch 3 Boil Mode Switch 8 Simmer Mode Switch 4 Power Switch 9 Simmer Mode Indicator 5 LED Display 3.1.1 Introduction CAUTION The Spaghetti Magic III (SMS III) computer used in 17EC/17ECS units is specially configured for them. The programming and operation of the 17EC/17ECS SMS III computer are different than those of the SMS III computers used in other products. The

  • Frymaster 17EC, 6-7 3. If replacing the regulator, adjust the replacement regulator output pressure to not more than 40 PSI (28.15 kg/cm 2 ) before installation in the cooker. 4. Recover the fittings from the failed component (regulator or solenoid valve) and install them on the replacement, using thread sealer on all connections. 5. Reverse Steps 1 and 2 to complete the procedure, being sure to apply thread sealer to all connections. NOTE: The regulator must be rotated approximately 45 degrees to clear the drain plumbing (see illustration at Step 2). 6.3.8 Replacing the Water Faucet 1. Drain the cookpot and disconnect the cooker from the

  • Frymaster 17EC, 3-2 LOW WATER SENSING automatically de-energizes the heating element if the water in the cookpot drops too low. When the water level in the cookpot is below the sensor probes, such as when draining and cleaning the cookpot, the controller display will read LO. NORMAL WATER LEVEL SENSING, on units configured with the AutoFill feature, automatically adds water during or after a cooking cycle if the water level is low. With this automatic filling feature, the water level does not have to be continuously monitored. The cookpot always has the correct amount of water. 3.1.2 Operating Instructions CAUTION If this is the first time the unit is being used after installation, refer t

  • Frymaster 17EC, 7-3 7.2 Accessing Equipment for Servicing DANGER Moving this equipment while it is filled with hot water may cause spilling or splattering of the hot water. Always drain the cookpot before attempting to relocate this equipment for servicing. 1. Disconnect the unit from the electrical power supply and from the water supply. 2. Remove any attached restraining devices. 3. Relocate the unit for service accessibility. 4. After servicing is complete, reconnect the unit to the water supply, reattach restraining devices, and reconnec

  • Frymaster 17EC, 7-14 required to maintain the temperature at the setpoint programmed into the computer or set on the thermostat knob. The contactor is the terminal block to which the element leads are connected and where actual contact is made between the leads and the line voltage. Built into the contactor is a 24VAC coil that energizes when signaled by the computer or interface board that the water temperature is below the setpoint. When it energizes, contact is made between the incoming line voltage and the element leads, and line voltage is supplied to the element. The element is a resistive heating device

  • Frymaster 17EC, 1-2 WARNING boxes contain information about actions or conditions that may cause or result in damage to your equipment, and which may cause your equipment to malfunction. DANGER DANGER boxes contain information about actions or conditions that may cause or result in injury to personnel, and which may cause damage or malfunctioning of your equipment 1.3 Equipment Description The automatic, high-volume Electric Cooker models ESW and EWBS are specifically designed for rethermalizing pre-cooked packaged foods, boi

  • Frymaster 17EC, 6-5 5. Loosen the small compression nut in the large fitting on the replacement thermostat so that the large fitting will move freely on the capillary tube (the thin, flexible tube). Carefully insert the replacement thermostat into the cookpot, being careful not to bend the thermostat tube. Position the tube along the inside of the left leg of the element (as viewed from the front of the cooker) and secure it in place with two metal wire ties. Apply thread sealer to the large fitting and screw the fitting securely into the cookpot. When the large fitting is tight, pull gently on the capillary tube to remove any slack, then screw the small compression nut into th

  • 6-29 6.6 Wiring Diagram (17ECS) TYPE 5AMP NO NC NC NO COM 132 BASKET LIFT SHOWN IN UP POSITION 53C GEAR MOTORS RELAY 24vdc BASKET LIFT LINE 12 4 653 987 10 11 12 151413 21 3 5641079 14131211 15 C1 C2 CNC HI LIMIT SOLENIOD 24 VAC OPTIONAL AUTOFILL COMPUTER CONTROL ALL READINGS REFERENCED TO GROUND WITH THE COMPUTER OPERATING S HOT COM POWER IN 24vac GND HEAT WATER FILL NO VOLTAGE WHEN HEATI

  • Frymaster 17EC, 6-19 6.5 Parts List 1 2 3 4 5 6 7 8 ITEM PART # COMPONENT 1 823-2939 Cooking Basket 2 823-2936 Starch Diverter 3 803-0268 Basket Support Rack * 210-5068 Pan Insert 4 910-7540 Cookpot/Rinse Tank Top Connecting Strip 5 823-2938 Rinse Basket 6 826-0900 Chain Restraint Kit 7 826-1117 Caster without Brake, 5-Inch (includes mounting hardware) 8 826-1118 Caster with Brake, 5-Inch (includes mounting hardware) ACCESSORIES

  • Frymaster 17EC, 1-1 ELECTRIC COOKER MODELS 17EC, 17ECS, ESW AND EWBS CHAPTER 1: GENERAL INFORMATION 1.1 Parts Ordering and Service Information In order to assist you as quickly as possible, the Frymaster Factory Authorized Service Center (FASC) or Service Department representative requires certain information about your equipment. Most of this information is printed on a data plate affixed to the inside of the door. Parts orders may be placed directly with your local FASC or distributor. Included with cookers when shipped from the factory is a list

  • Frymaster 17EC, 3-3 When the water is at or above the minimum temperature for boiling (transition temperature), the controller pulses power to the elements at a programmable rate. The range can be set between 0 and 9. The default setting is 5. When the water temperature is below boiling point, the power application is 100 percent. To set the Transition Temperature/Boil Intensity: 1. Verify that the controller is OFF (the display is blank). 2. Press the Simmer (right thermometer icon) switch to enter the pro

  • Frymaster 17EC, 7-23 ITEM PART # COMPONENT 1 Side, Left or Right Cabinet 910-7377 Stainless Steel 900-7377 Cold Rolled Steel (Painted) 2 910-2914 Side, Double Unit Inner Cabinet 3 900-5023 Back, Cabinet 4 824-0633 Backsplash (units without basket lifts) 5 810-0044 Plug, ⅞-inch (used on units without basket lifts or faucets) 6 823-2105 Backsplash (used on units with basket lifts) 7 910-8355 Cover, Backsplash Top (used on basket lift units without faucet) 8 910-8060 Cover, Backsplash Top (used on basket lift units with faucet) 9 910-8058 Restrictor, Faucet Rotation

  • Frymaster 17EC, 7-13 7.4.3 How the Autofill and Skim Systems Work The heart of the automatic filling (Autofill) system is a normally closed solenoid valve that opens when 24VAC is applied as a result of the loss of upper water-level sensor ground. The ground is lost when the sensor is not in contact with water in the cookpot. Starch or lime build-up on the sensor may keep a ground from forming. Therefore always make sure the sensor is clean and its lead is firmly connected to Pin 1 of the 6-pin connector on the interface board (units with manual controls) or connector J5 on

  • 7-1 ELECTRIC COOKER MODELS 17EC, 17ECS, ESW AND EWBS CHAPTER 7: ESW & EWBS SERVICE PROCEDURES & PARTS 7.1 Functional Description The ESW series was the predecessor to the EWBS series. Both cookers are very similar in construction and function. The cookers in the ESW series have rocker-switch controls only. These cookers were configured as single units or

  • Frymaster 17EC, 3-6 SETTING THE UNIT UP FOR FIRST-TIME OPERATION Before turning the cooker on, ensure that: • the unit is connected to the water supply. • the water supply is turned on. • the unit is plugged into an appropriate outlet. • the electrical power supply is turned on. CAUTION It is recommended that the simmer setpoint and the cook/stir times for all 10 products be programmed before the unit is first used in a cooking cycle. When the unit is tested at the factory, the simmer setpoint and product cook times are programmed. These test s

  • Frymaster 17EC, 6-8 2. If rigid water connections have been used, disconnect the cooker from the incoming water supply. 3. Remove the basket lift arms from the lifter rods and then reposition the cooker to gain access to the rear. Remove the upper and lower basket lift rear panels. 4. Unplug the basket lift wiring harness from the lower 6-pin connector on the component box. (To do this, you must reach around behind the component box from the front of the cooker.) Disconnect basket lift wiring harness from this connector. 5. Disconnect the basket lift link from the lifter cam (bell crank) assemblies one at a time. When

  • 7-26 72C 39C 40C 44C 41C 55C 54C 58C 59C 42C 38C 34C 28C 14C 25C 43C 34C 22C 44C 25C 23C 16C 27C 10C 7C 7C 9C 12C 11C 19C 2C 5C 18C 1C 2C 4C 3C 72C 39C 40C 44C 42C 41C 3 21 4 65 7 8 9 10 11 12 13 17 14 15 18 16 19 17 20 11 21 22 23 24 25 10 26 27 28 29 30 31 32 33 34 35 36 37 4H 1H 2H 3H 5H 6H 30C 20C 21C ELECTRONICS

  • Frymaster 17EC, 6-26 15 12 14 13 11 10 9 8 7 6 5 4 3 2 1 21C ORG 22C GRN/YLW 23C BRN 24C ORG 25C ORG 26C RED 28C BRN 30C RED 32C BRN 1H BLK 3 2 1 2H BLK 3H BLK 4H BLK 5H BLK 6H BLK6 5 4 9 8 7 6 5 4 3 2 1 41C WHT 42C WHT 43C BLK 6 5 4 3 2 1 51C W HT 52C W HT 53C BLK 1C BLK 2C BLK 3C BLK 15 12 14 13 11 10 9 8 7 6 5 4 3 2 1 15 12 14 13 11 10 9 8 7 6 5 4 3 2 1 4C BLK 5C BLK 6C BLK 7C BLU 8C W HT 9C BLU 10C BLK 11C BLK 12C BLK 15C WHT 1H BLK 6 5 4 3 2 1 2H BLK 3H BLK 4H BLK 5H BLK 6H BLK 6 7 8 9 10 11 1 2 3 4 5 12 13 1716 15 14 18 19 20 21 24 22 23 25 26 27 28 29 21 38 39 40 41 42 43 30 33 31 32 34 35 36 37 ELECTRONI

  • 6-12 The temperature probe is used only when the unit is in the simmer mode. When the operator selects the simmer mode, logic circuits in the computer monitor the temperature of the water and cycle power to the element on and off as required to maintain the temperature at the setpoint programmed into the computer. The contactor is the terminal block to which th

  • Frymaster 17EC, 7-8 Note D-shaped pin and rib identifying Hole 1. Hole 6 Hole 8 7. Reattach the 12-pin connector to the interface board, close the control panel, and replace the two screws removed in Step 2. 7.3.7 Replacing the Pressure Regulator or Solenoid Valve 1. Drain the cookpot and disconnect the cooker from the electrical power supply. If necessary, reposition the cooker to allow free access to the component to be replaced. Turn off or disconnect the water supply to the cooker. If replacing an Autofill system pressure regulator or solenoid valve on a unit equipped with basket lifts, the basket lift upper rear panel must be removed. 2. Loosen the compression fitti

More Instructions:

DOWNLOAD

Related Products and Documents (Cooktop):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 ATV 200 Service manual atv/200-49C.pdf 22 Jul 2022 223
2 Vitek VTC-LED667HRCB Specifications vitek/vtc-led667hrcb-HT4.pdf 30 Aug 2023 2 0.72 Mb
3 EverFocus EPHD16+U Operation & user’s manual everfocus/ephd16u-N9Y.pdf 15 Aug 2022 100
4 Kenmore 859841 Use & care manual kenmore/859841-6H8.pdf 24 Aug 2023 120
5 Samsung ATIV Smart PC Pro 5 Operation & user’s manual samsung/ativ-smart-pc-pro-5-8I7.pdf 09 Feb 2023 128 12.34 Mb
6 Xexun Tk 102-2 Operation & user’s manual xexun/tk-102-2-U27.pdf 25 Jun 2023 16

Similar Resources:

  • Maytag

    W10274251A

    (16 pages)
    ELECTRIC COOKTOPUse & Care GuideFor questions about features, operation/performance, parts, accessories or service, call: 1-800-688-9900 In Canada, call: 1-800-807-6777 or visit our website atwww.maytag.com or www.maytag.caTABLE DE CUISSON ÉLECTRIQUEGuide d’utilisation et d’entretienAu Canada, pour assistance, installation ou service, composez le : …
  • GE

    JBP80DM

    (2 pages)
    Dimensions and Installation Information (in inches) For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000.Listed by Underwriters LaboratoriesAll GE ranges are equipped with an Anti-Tip device. The installation of this device is an important, required step in t …
  • Westinghouse

    GOP474

    (28 pages)
    Gas Built-in Cooking AppliancesWMAN_541_Jun10.indd 1 4/6/10 10:18:28 AM …
  • Whirlpool

    SCS3017RB03

    (3 pages)
    COOKTOP, BURNER AND GRATE PARTS1For Models: SCS3017RB03, SCS3017RQ03, SCS3017RT03, SCS3017RS03(Black) (Designer White) (Biscuit) (Stainless)10−07 Litho in U.S.A. (amd)Part No. W10168541 Rev. A30" GAS COOKTOPIllus. PartNo. No. DESCRIPTIONIllus. PartNo. No. DESCRIPTIONIllus. PartNo. No. DESCRIP …
  • Thermador

    PGR30

    (48 pages)
    Thermador Professional® RangeFOR RESIDENTIAL USE ONLYAll Gas Models PGR30, PGR36, PGR48LE MANUEL DE SOIN ET D’UTILISATIONEN ENGLAIS AVEC ADVERTISSEMENTS EN FRANÇAISCare and Use Manual© 2002 BSH Home Appliances Corp.Model PGR304Model PGR364GLLow Back Model LB36RModel PGR484GGLow Back Model LB48R …
  • Jenn-Air

    PRO-STYLE 8113P757-60

    (64 pages)
    Models/Modèles JGS8850, JGS8860, JGS8750JENN-AIR® GAS SLIDE-IN RANGECUISINIÈRE À GAZ ENCASTRABLE JENN-AIR®Use & Care GuideFor questions about features, operation/performance, parts, accessories, or service in the U.S.A., call: 1-800-JENNAIR (1-800-536-6247) or visit our website at www.jennair.com.In Canada, call: 1-800-807-6777, or visit our website …

Comments, Questions and Opinions: