Manualios.com

Schumacher 00-99-000659 Owner's Manual

Schumacher 00-99-000659 Manual Online:

3.55, 969 votes
Schumacher 00-99-000659 User Manual
Schumacher 00-99-000659 User Guide
Schumacher 00-99-000659 Online Manual

Text of Schumacher 00-99-000659 User Guide:

  • Schumacher 00-99-000659, Portable Power Jump Starter/DC Power Source  AC Power CAUTION: Read all Safety Rules and Operating Instructions, and follow them with each use of this product. 00-99-000659/0606 OWNER’S MANUAL Schumacher Electric Corporation Mount Prospect, IL 60056 U.S.A.  Customer Service Returns P.O. Box 280, 1025 E. Thompson, Hoopeston, IL 60942-0280 Questions? Call Customer Service: 1-800-621-5485  

  • Schumacher 00-99-000659, 2 TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS .....................................................................3 PERSONAL SAFETY PRECAUTIONS ........................................................................3  .......................................4 Charge Internal Battery ..........................................................................................4 OPERATING INSTRUCTIONS ...

  • 3 WARNING: POSSIBLE EXPLOSION HAZARD, CONTACT WITH BATTERY ACID MAY CAUSE SEVERE BURNS AND BLINDNESS. KEEP OUT OF REACH OF CHILDREN. To reduce risk of battery explosion, follow these instructions and those published by battery manufacturer and manufacturer of any equipment you intend to use in vicinity of battery. Review cautionary markings on these prod

  • Schumacher 00-99-000659, 4 • Take care not to drop any metal tool or metal object onto the battery. This may spark or short circuit the battery or another electrical device that may cause an explosion. •  operate the Portable Power in an open, well-ventilated area. • Never smoke, use matches or cigarette lighter or allow a spark or ame in the vicinity of the battery or engine. Batteries generate explosive gases. • Never operate the Portable Power if it has damaged lead wire or clamps. If damaged, have the lead wire replaced by a qualied technician. •     �

  • 5 12V DC eleCtriCal DeViCe example run-time Chart       

  • Schumacher 00-99-000659, 6 USING THE AIR COMPRESSOR CAUTION: Read instructions of the product being inated before using the air compressor. The air compressor is rated 250 PSI. Avoid over ination. Do NOT exceed the manufacturer’s recommended pressures. Do NOT leave the air compres- sor unattended during use. 1. Remove air c o mpressor hose wrapped in the back storage com- partment. 2. To inate a tire, attach the permanent nozzle connected to the end of the air compressor hose and attach to tire stem. Flip down lever. 3. To inate items other than tires, use one of the three nozzles stored in the center back left compartment. Slide the panel to the left to

  • Schumacher 00-99-000659, 7  IMPORTANT SAFETY INSTRUCTIONS NOTE: The JUMP START switch must be in the OFF position before using the inverter. • The PP-18400CI comes with an internal inverter. It must be well ventilated in order to properly disperse heat while it is in use. Make sure there are several inches of clearance around the top and sides of the PP-18400CI. DO NOT block the vents on the back of the PP-18400CI. • Make sure the PP-18400CI is not close to any potential source of ammable fumes, gases or clothing. • Keep the PP-18400CI

  • Schumacher 00-99-000659, 8 110V aC eleCtriCal DeViCe example run-time Chart           

  • Schumacher 00-99-000659, 9 DIGITAL DISPLAY FUNCTIONS 1. PP-18400CI – To check the internal battery’s status, press the DISPLAY button on the front of the PP-18400CI. The display will show the voltage of the internal battery. 2. When hooked up to the vehicle's battery, the digital display shows the combined vehicle's voltage and the PP-18400CI's internal battery volt- age. 3. AC Power – When using the PP- 18400CI inverter, the digital display shows the wattage and voltage of the device being powered. Push the DISPLAY button to read wattage or push DISPLAY button again to read voltage. The internal battery is specically designed to deliver

  • Schumacher 00-99-000659, 10 SPECIFICATIONS Internal Battery Type Maintenance-free AGM Lead-acid Nominal Voltage 12 Volt DC Capacity 18 Ah DC Power Outlet 15A Built-in Light Bulb (Replaceable) 2.5w/12v DC Jumper Cables Heavy Duty 24 Inch Dimensions (H X W X D) 12 H X 11.5 X 10.5 Inches Product Weight 24.5 Lbs. AC POWER SPECIFICATIONS Maximum Continuous Power ........................................................................ 400 Watts Surge Capacity (Output Wattage) ................................................................. 800 Watts No Load Current Draw ...........................................

  • Schumacher 00-99-000659, 11 LIMITED WARRANTY Schumacher Electric Corporation warrants your unit to be free from defects in material and workmanship, excepting abuse or misuse, for a period of one year from the date of sale to the original user or consumer purchaser. If your unit fails or malfunctions within the rst 30 days of the warranty, we will replace it with a new unit. If your unit malfunc- tions or fails within the 12 month warranty period because of a defect in material or workmanship, we will repair without charge. The internal battery, excluding units with swollen batteries or melted battery terminals, carries a 90-day warranty from the date of purchase. Proof

  • Schumacher 00-99-000659, 12 Send Warranty Product Repairs to: Schumacher Electric Corporation, 1025 East Thompson, Hoopeston, IL 60942-0280. Call Customer Service if you have questions: 1-800-621-5485. 801 Business Center Drive, Mount Prospect, IL 60056-2179 ELECTRIC CORPORATION CONTAINS SEALED NON-SPILLABLE LEAD-ACID BATTERY. MUST BE DISPOSED OF PROPERLY. WARNING: Possible explosion hazard. Contact with battery acid may cause severe burns and blindness. Keep out of reach of children.

Related Products and Documents (Power Supply):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Huawei OceanStor S2600 Command reference manual huawei/oceanstor-s2600-DGZ.pdf 05 Jun 2023 274
2 Escort ZR3 Installation manual escort/zr3-28A.pdf 01 Jan 2023 2 0.24 Mb
3 Jensen SMPS-85 Operation & user’s manual jensen/smps-85-RPB.pdf 12 Dec 2023 7
4 Cisco AIR-PCM352 - Aironet 350 Series 11Mbps Wireless LAN PC Card Adapter Installation and configuration manual cisco/air-pcm352-aironet-350-series-11mbps-wireless-lan-pc-card-adapter-65K.pdf 13 Aug 2023 180 3.14 Mb
5 Chauvet SlimPAR 56 IRC IP Operation & user’s manual chauvet/slimpar-56-irc-ip-ZM1.pdf 27 May 2023 16 0.91 Mb
6 Navitar 1-51210 Dimensional drawing navitar/1-51210-P7P.pdf 15 Jun 2023 1

Similar Resources:

  • Cosel

    PCA600F

    (12 pages)
    Basic Characteristics DataBasic Characteristics DataModel Circuit methodSwitchingfrequency[kHz]Inputcurrent[A]Ratedinput fuseInrushcurrentprotectioncircuitPCB/PatternSeries/Paralleloperation availability MaterialSinglesidedDoublesidedSeriesoperationParalleloperationPCA600FActive filter 15 - 4007.3 250V 16A Relay FR-4 - Ye s Ye s Ye sBuck converter 88Full - …
  • Schumacher

    IP-1850FL

    (2 pages)
    Schumacher Electric CorporationModel IP-1850FLOWNER’S MANUAL INSTANT POWER™ Jump Starter & DC Power SourceTHIS PRODUCT HAS A SEALED LEAD-ACID BATTERY INSIDE THAT SHOULD BE KEPT AT FULL CHARGE FOR LONGER LIFE.RECHARGE WHEN FIRST RECEIVED (EVEN IF GREEN ‘FULL POWER’ LED GLOWS), AFTER EACH USE AND EVERY 3 MONTHS.IMPORTANT SAFETY INSTRUCTIONSSave the …
  • VersaLogic

    EPMs-PS1

    (24 pages)
    Distributor of VersaLogic Corporation: Excellent Integrated System LimitedDatasheet of VL-EPMS-PS1A - SUMIT-104, POWER SUPPLY 50 W Contact us: [email protected] Website: www.integrated-circuit.com Excellent Integrated System LimitedExcellent Integrated System LimitedStocking DistributorStocking DistributorClick to view price, real time Inventory, …
  • Puls

    QS10.241-60

    (27 pages)
    QS10.241-60 Q-Series 24V, 200W, DC/DC CONVERTER DC/DC CONVERTER  EN 50155 Railway Compliant  Conformal Coated PC-boards  Quick-connect Spring-clamp Terminals  77-154Vdc Wide-range Input  Width only 60mm  Efficiency up to 93.0%  Excellent Partial Load Efficiency  Minimal Inrush Current Surge  Full Power Between -40°C …
  • Allen-Bradley

    140G Series

    (2 pages)
    Low terminal cover for 140G-N, 140G-NSCopriterminali bassi Flache Klemmenabdeckungen Cache-bornes bas Cubreterminales bajos DIR 1000529R0651 (L2770)WARNING: WARNUNG: AVERTISSEMENT: To prevent electrical shock, disconnect from power source before installing or servicing. Install in suitable enclosure. Keep free from contaminants. (Follow NFPA70E requir …
  • Tripp Lite

    SmartPro AG-03AD Series

    (60 pages)
    1Owner’s ManualSmartPro® 1U Rack-Mount Intelligent, Line-Interactive UPS SystemsImportant Safety Instructions 2Mounting 3Quick Installation 4Optional Installation 6Basic Operation 7Storage and Service 10Battery Replacement 11Product Registration 12Español 13Français 25Русский 37Deutsch 491111 W. 35th Street, Chicago, IL 60609 USA • tri …

Comments, Questions and Opinions: