Fujitsu ASBA30JFC Operating Manual
|
Fujitsu ASBA30JFC, EnglishEspañolPortuguês P/N9315345325-03 OPERATING MANUAL MANUAL DE FUNCIONAMIENTO MANUAL DE INSTRUÇÕES Indoor Unit ASBA30JFC Outdoor Unit AOBR30JFT COOL MODEL ROOM AIR CONDITIONER WALL MOUNTED TYPE KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE GUARDE ESTE MANUAL DE USO PARA FUTURAS CONSULTAS GUARDE ESTE MMANUAL DE FUNCIONANENTO PARA REFERÊNCIA FUTURA 9315345325-03_OM.indb 19315345325-03_OM.indb 1 2/25/2013 10:08:18 AM2/25/2013 10:08:18 AM
Fujitsu ASBA30JFC, En-1 CONTENTS SAFETY PRECAUTIONS ● Do not attempt to install this air conditioner by yourself. ● This unit contains no user-serviceable parts. Always consult authorized service per- sonnel for repairs. ● When moving, consult authorized service personnel for disconnection and installation of the unit. ● Do not become excessively chilled by staying for lengthy periods in the direct cooling airfl ow. ● Do not insert fi ngers or objects into the outlet port or intake grilles. ● Do not start and stop air conditioner operation by disconnecting the power supply cord and so on. ● Take care not to damage
Fujitsu ASBA30JFC, En-2 FEATURES AND FUNCTIONS INVERTER At the start of operation, a large power is used to bring the room quickly to the desired temperature. Afterwards, the unit automatically switches to a low power setting for economic and comfortable operation. AUTO CHANGEOVER The operation mode (cooling, dry) is switched automatically to maintain the set temperature, and the temperature is kept constant at all times. PROGRAM TIMER The program timer allows you to integrate OFF timer and ON timer operations in a single sequence. The sequence can involve one transition from OFF timer to ON ti
Fujitsu ASBA30JFC, En-3 NAME OF PARTS OPERATION TIMER SUPER QUIET ᒝ⥄േ MANUAL AUTO A E 9 1 = 8 3 1 8 3 BC D F G I H 5 6 4 7 2 Fig. 5 Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 6 M Y ^ [ ] P Q K L J N W R S T U O V a \ Z b X Fig. 7 To facilitate explanation, the accompanying illustra- tion has been drawn to show all possible indicators; in actral operation, however, the display will only show those indicators appropriate to the current operation. 9315345325-03_OM.indb Sec1:39315345325-03_OM.indb Sec1:3 2/25/2013 10:08:39 AM2/25/2013 10:08:39 AM
Fujitsu ASBA30JFC, En-4 Fig. 6 Remote Controller J SLEEP button K MODE button L SET TEMP. button ( / ) M Signal Transmitter N TIMER MODE button O TIMER SET ( / ) button P FAN button Q START/STOP button R SET button (Vertical) S SET button (Horizontal) T SWING button U RESET button V TEST RUN button ● This button is used when installing the condi- tioner, and should not be used under normal conditions, as it will cause the air conditioner’s thermostat function to operate incorrectly. ● If this button is pressed during normal opera- tion, the unit will switch to test operation mode, and the Indoor Unit’s OPERATION Indicator Lamp and TIMER Indicator Lamp will begin to fl ash s
Fujitsu ASBA30JFC, En-5 PREPARATION CAUTION! ● Take care to prevent infants from acciden- tally swallowing batteries. ● When not using the Remote Controller for an extended period, remove the batteries to avoid possible leakage and damage to the unit. ● If leaking battery fl uid comes in contact with your skin, eyes, or mouth, immediately wash with copious amounts of water, and consult your physician. ● Dead batteries should be removed im- mediately and disposed of properly, either in a battery collection receptacle or to the appropriate authority. ● Do not attem pt to recharge dry batteries. Never mix new and used batteries, or bat- teries of diff
En-6 To Select Mode Operation 1 Press the START/STOP button (Fig.6 Q). The indoor unit’s OPERATION Indicator Lamp (red) (Fig. 3 5) will light. The air conditioner will start operating. 2 Press the MODE button (Fig.6 K) to select the desired mode. Each time the button is pressed, the mode will change in the following order. AUTO COOL DRY
Fujitsu ASBA30JFC, En-7 To Stop Operation Press the START/STOP button (Fig. 6 Q). The OPERATION Indicator Lamp (red) (Fig. 3 5) will go out. About AUTO CHANGEOVER Operation AUTO: ● When AUTO CHANGEOVER operation fi rst selected, the fan will operate at very low speed for about one minute, during which time the unit detects the room conditions and selects the proper operating mode. If the differance between thermostat setting and actual room temperature is more than +2 °C Cooling or dry operation If the difference between thermostat setting and actual room temperature is within
Fujitsu ASBA30JFC, En-8 TIMER OPERATION Before using the timer function, be sure that the Remote Controller is set to the correct current time (☞ P. 5). To Use the ON timer or OFF timer 1 Press the START/STOP button (Fig. 6 Q) (if the unit is already operating, proceed to step 2). The indoor unit’s OPERATION Indicator Lamp (red) (Fig. 3 5 ) will light. 2 Press the TIMER MODE button (Fig. 6 N) to select the OFF timer or ON timer operation. Each time the button is pressed the timer function changes in the following order: CANCEL OFF ON PROGRAM(OFF ON, OFF ON) The indoor unit’s green TIMER I
Fujitsu ASBA30JFC, En-9 SLEEP TIMER OPERATION Unlike other timer functions, the SLEEP timer is used to set the length of time until air conditioner operate is stopped. To Use the SLEEP Timer While the air conditioner is operating or stopped, press the SLEEP button (Fig. 6 J). The indoor unit’s OPERATION Indicator Lamp (red) (Fig. 3 5) lights and the TIMER Indicator Lamp (green) (Fig. 3 6) light. To Change the Timer Settings Press the SLEEP button (Fig. 6 J) once again and set the time using the TIMER SET ( / ) buttons (Fig. 6 O). Set the time while the Ti
En-10 ADJUSTING THE DIRECTION OF AIR CIRCULATION ● Adjust the up, down, left, and right AIR directions with the AIR DIRECTION buttons on the Remote Controller. ● Use the AIR DIRECTION buttons after the Indoor Unit has started operating and the airfl ow-direction louvers have stopped mov- ing. DANGER! ● Never place fi ngers or foreign objects inside the outlet ports, since the
En-11 To select SWING Operation Press the SWING button (Fig. 6 T). The SWING Display (Fig. 7 b) will light. Each time the SWING button is pressed, the swing operation will change in the following order. To stop SWING Operation Press the SWING button and select STOP. Airfl ow direction will return to the setting before swing was begun. SWING OPERATION Begin air conditioner operation
Fujitsu ASBA30JFC, En-12 Cleaning the Intake Grille 1. Remove the Intake Grille. 1 Place your fi ngers at both lower ends of the grille panel, and lift forward; if the grille seems to catch partway through its movement, continue lifting upward to remove. 2 Pull past the intermediate catch and open the Intake Grille wide so that it become horizontal. 2. Clean with water. Remove dust with a vacuum cleaner; wipe the unit with warm water, then dry with a clean, soft cloth. 3. Replace the Intake Grille. 1 Pull the knobs all the way. 1 2 Intake
Fujitsu ASBA30JFC, En-13 Air Cleaning Filter Installation 1. Open the Intake Grille and remove the Air fi lters. 2. Install the Air cleaning fi lter set (set of 2). 1 Set the air cleaning filter into the air cleaning filter frame. 2 Engage the latch at both ends of the fi lter with the two hooks at the rear of the air cleaning fi lter frame. Take care that the air cleaning fi lter does not project beyond the frame. 3 Engage the four fi xing locations at the top and bottom of the air cleaning fi lter frame with the hooks of the air fi lter. 3. Install the two Air fi lters and close the Intake Grille. ● When air cleaning fi lters are used, the effect will increased by setting the f
Fujitsu ASBA30JFC, En-14 TROUBLESHOOTING WARNING! In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the electrical breaker or disconnect the power supply plug, and consult authorized service personnel. Merely turning off the unit’s power switch will not completely disconnect the unit from the power source. Always be sure to turn off the electrical breaker or disconnect the power supply plug to ensure that power is completely off. Before requesting service, perform the following checks: Symptom Problem See Page NORMAL FUNCTIO
En-15 TROUBLESHOOTING If the problem persists after performing these checks, or if you notice burning smells, or both the ORERATION Indicator Lamp (Fig. 3 5) and the TIMER Indicator Lamp (Fig. 3 6) fl ashes, or only the TIMER Indicator Lamp (Fig. 3 6) fl ashes, immediately stop operation, disconnect the Power Supply, and consult authorized service personnel. Temperature and Humidity Ran
Fujitsu ASBA30JFC, En-16 SPECIFICATIONS MODEL INDOOR UNIT ASBA30JFC OUTDOOR UNIT AOBR30JFT TYPE COOLING TYPE POWER 220 V ~ 60 Hz COOLING CAPACITY [kW] 7.91 [BTU/h] 27,000 POWER INPUT [kW] 2.32 CURRENT (MAX.) [A] 10.7 (17.0) ENERGY EFICIENCY RATIO [kW/kW] 3.41 AIRFLOW INDOOR UNIT [m 3 /h] 1,100 OUTDOOR UNIT [m 3 /h] 3,600 MAX. PRESSURE [MPa] 4.12 REFRIGERANT (R410A) [kg] 1.90 DIMENSIONS & WEIGHT (NET) INDOOR UNIT HEIGHT [mm] 320 WIDTH [mm] 998 DEPTH [mm] 2
Fujitsu Inverter ARTG09LL Air Conditioner Operating manual
Inverter ARTG09LL |
Fujitsu AR-90T Air Conditioner Technical manual
AR-90T |
Fujitsu AUXG18LRLB Air Conditioner Technical manual
AUXG18LRLB |
Fujitsu R410A 9370937022 Air Conditioner Installation instruction sheet
R410A 9370937022 |
Fujitsu AOU15RLQ Air Conditioner Operating manual
AOU15RLQ |
Fujitsu ART Series Air Conditioner Operating manual
ART Series |
Fujitsu AWY24FBAJ Air Conditioner Service manual
AWY24FBAJ |
Fujitsu AOU18RC Air Conditioner Operating manual
AOU18RC |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Edimax | Wireless LAN Access Point | Operation & user’s manual | edimax/wireless-lan-access-point-GM5.pdf | 07 Oct 2022 | 41 | 0.41 Mb |
2 | Fisher-Price | H8096 | Instruction sheet | fisher-price/h8096-U5T.pdf | 28 May 2023 | 6 | 0.59 Mb |
3 | RCA | CC9370 | Operation & user’s manual | rca/cc9370-K81.pdf | 19 Jul 2022 | 84 | 1.48 Mb |
4 | REVELL | KIT 1916 | Assembly manual | revell/kit-1916-HMX.pdf | 24 Jul 2022 | 2 | 2.51 Mb |
5 | SMC Networks | HPAV-ESW FICHE | Product overview | smc-networks/hpav-esw-fiche-581.pdf | 13 Oct 2023 | 2 | 0.19 Mb |
6 | Canon | PowerShot A70 | Quick start manual | canon/powershot-a70-VDO.pdf | 15 Nov 2023 | 2 | 0.78 Mb |
Carrier
48JZSingle-Packaged Gas Heat/Electric Heat PumpUnit with Puron (R-410A) RefrigerantA Guide to Operating and Maintaining YourSingle-Packaged Gas Heat/Electric Heat Pump UnitNOTE: Read the entire instruction manual before starting theinstallation.SAFETY CONSIDERATIONSNote to Installer: This manual should be left with the equipmentuser.Do not store or use gasol …
48JZ(4 pages) |
Fujitsu
P/N9373117063KEEP THIS MANUAL FOR FUTURE REFERENCECONSERVEZ CE MODE D’EMPLOI AFIN DE POUVOIR VOUS Y RÉFÉRER ULTÉRIEUREMENTGUARDE ESTE MANUAL PARA PODERLO CONSULTAR EN EL FUTUROOPERATING MANUALMODE D’EMPLOIMANUAL DE FUNCIONAMIENTOEnglishCONCEALED CEILING TYPEFrançaisEspañolAIR CONDITIONERSUMOTUWETH FRSAAMPM3 6 912 15 18 21FUJITSU GENERAL LIMITEDOM_93 …
Halcyon(14 pages) |
Nordyne
For installation in:1. Manufactured Homes2. Recreational Vehicles, Park Models, Manufactured Buildings3. Modular Homes/Buildings WARNING:If the information in this manual is not followed exactly, a fi re or explosion may result causing property damage, personal injury or loss of life. – Do not store or use gasoline or other fl ammabl …
M1B(40 pages) |
London Cool
PT7300 Operating Instructions General Safety Never place anything on top of the indoor or outdoor units and never obstruct their air vents. Leave a 300mm gap all round the unit to let the air circulate Always switch OFF and unplug the unit when not in use. ALWAYS TRANSPORT, STORE, AND OPERATE THIS UNIT IN AN UPRIGHT POSITION. DO NOT LAY T …
PT7300(3 pages) |
Frigidaire
E&CA E UALNOTE: This USE & CARE MANUAL pro-vides specific operating instructions for you rmodel. Use the room air conditioner onlyas instructed in this USE & CARE MANUAL.These instructions are not meant to coverevery possible condition and situation thatmay occur. Common sense and cautionmust be practiced when installing operat-ing and maintainin …
FAA063P7A16(12 pages) |
Mitsubishi Electric
HFCutilizedR410ATMPARTS CATALOG (OBB702)INDOOR UNITSERVICE MANUALOUTDOOR UNITModelsMXZ-2C20NA2-U1MXZ-3C24NA MXZ-3C24NA2-U1MXZ-3C30NA MXZ-3C30NA2-U1MXZ-4C36NA MXZ-4C36NA2-U1MXZ-5C42NA MXZ-5C42NA2-U1MXZ-2C20NAHZ MXZ-2C20NAHZ2-U1MXZ-3C24NAHZ MXZ-3C24NAHZ2-U1MXZ-3C30NAHZ MXZ-3C30NAHZ2-U1No. OBH702REVISED EDITION-GOBH702 REVISED EDITION-F is void.Revision G:• 4 …
MXZ-2C20NA2-U1(114 pages) |
Motorola Network Storage Server EXORdisk IIMotorola EXORdisk II Manual (Operation & user’s manual), @383257 EXORdisk II, 517 |
HP Docking Station QuickDockPDF Guide (@LQ9829), HP QuickDock Docking Station (Sun 09.2023) QuickDock, 52 |
Siemens Multi-service Platforms RUGGEDCOM RX1400#377JL9 RUGGEDCOM RX1400: Siemens Multi-service Platforms Owner Documentation RUGGEDCOM RX1400, 39 |
Allen-Bradley Controller 160 SSCAllen-Bradley Product Guide: 160 SSC PDF Installation manual - TZRKA7 160 SSC, 58 |
Panasonic Stereo System SA-VK81DEEPanasonic SA-VK81DEE Manual (Doc Type: Stereo System Service manual) SA-VK81DEE, 153 |
American Dynamics Software Version 4.3 Software Update 3American Dynamics Product Guide: Version 4.3 Software Update 3 PDF Release notes - Q6WER6 Version 4.3 Software Update 3, 11 |
Honda Engine GX240Honda Engine GX240 Maintenance instruction GX240, 1 |
Oldsmobile Automobile 1996 SilhouetteAutomobile PDF Owner's manual 1996 Silhouette, 372 |
Delta Air Compressor 66-750Instruction manual for Delta 66-750 Air Compressor 66-750, 30 |
Asus Motherboard M3A78 - Motherboard - ATX#1L79QT: M3A78 - Motherboard - ATX Motherboard Owner's manual M3A78 - Motherboard - ATX, 104 |
Aiwa Stereo System XR-EM70Stereo System #2742CX XR-EM70, 55 |
LaCie Firewire Hard Disk MAX QuadraLaCie Hard Disk MAX Quadra Guide (Doc Type: Firewire Datasheet) Hard Disk MAX Quadra, 2 |