  • Fujitsu ASTB24LDC, KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED OPERATING MANUAL P/N9315345080-01 Indoor Unit ASTB24LDC Outdoor Unit AOTS24LDC HEAT & COOL MODEL (REVERSE CYCLE) ROOM AIR CONDITIONER WALL MOUNTED TYPE R410A REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A and Polyol Ester oil. THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED BY QUALIFIED PERSONNEL. Refer to Commonwealth, State, Territory and local legislation, regulations, codes, installation & operation manuals, before the installation, maintenance and/or service of this product.

  • Fujitsu ASTB24LDC, 1 CONTENTS SAFETY PRECAUTIONS .......................................... 1 FEATURES AND FUNCTIONS ................................. 2 NAME OF PARTS ...................................................... 3 PREPARATION .......................................................... 5 OPERATION .............................................................. 6 AIR CLEANING OPERATION .................................... 8 TIMER OPERATION .................................................. 9 SLEEP TIMER OPERATION .................................... 10 MANUAL AUTO OPERATION .............

  • Fujitsu ASTB24LDC, 2 FEATURES AND FUNCTIONS INVERTER At the start of operation, a large power is used to bring the room quickly to the desired temperature. Afterwards, the unit automatically switches to a low power setting for eco- nomic and comfortable operation. COIL DRY OPERATION The Indoor unit can be dried by pressing the COIL DRY but- ton on the Remote Control Unit so as to avoid going moldy and restrain the breed of bacterium. AUTO CHANGEOVER The operation mode (cooling, dry, heating) is switched au- tomatically to maintain the set temperature, and the tem- perature is kept constant at all times. PROGRAM TIMER The program timer allows you to integrate OFF timer and ON

  • Fujitsu ASTB24LDC, 3 OPERATION TIMER AIR CLEAN Ջࣱݻବ MANUAL AUTO 8 3 1 5 6 4 7 2 F G I H A E 9 1 = 8 3 C D B Fig. 5 Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 7 To facilitate explanation, the accompanying illustra- tion has been drawn to show all possible indicators; in actral operation, however, the display will only show those indicators appropriate to the current op- eration. Fig. 6 O [ b ] a R S K M N L J P Y T U V W Q X d c e ^ \ f Z NAME OF PARTS

  • 4 Fig. 6 Remote Control Unit J SLEEP button K MASTER CONTROL button L AIR CLEAN button M SET TEMP. button ( / ) N COIL DRY button O Signal Transmitter P TIMER MODE button Q TIMER SET ( / ) button R FAN CONTROL button S START/STOP button T SET button (Vertical) U SET button (Horizontal) V SWING button W RESET button X TEST RUN button ● This button is used when installing the cond

  • Fujitsu ASTB24LDC, 5 PREPARATION CAUTION! ● Take care to prevent infants from accidentally swallowing batteries. ● When not using the Remote Control Unit for an extended period, remove the batteries to avoid possible leakage and damage to the unit. ● If leaking battery fluid comes in contact with your skin, eyes, or mouth, immedi- ately wash with copious amounts of water, and consult your physician. ● Dead batteries should be removed immediately and disposed of properly, either in a battery collection receptacle or to the appropriate authority. ● Do not attempt to recharge dry batteries. Never mix new and used batteries, or batteries of different t

  • Fujitsu ASTB24LDC, 6 To Select Mode Operation 1 Press the START/STOP button (Fig.6 S). The indoor unit’s OPERATION Indicator Lamp (red) (Fig. 3 5) will light. The air conditioner will start operating. 2 Press the MASTER CONTROL button (Fig.6 K) to se- lect the desired mode. Each time the button is pressed, the mode will change in the following order. AUTO COOL DRY HEAT FAN About three seconds later, the entire display will reappear. To Set the Thermostat Press the SET TEMP. button (Fig. 6 M). button: Press to raise the thermostat setting. button: Press to lower the thermostat setting. ●Thermostat setting range: AUTO .................

  • Fujitsu ASTB24LDC, 7 To Stop Operation Press the START/STOP button (Fig. 6 S). The OPERATION Indicator Lamp (red) (Fig. 3 5) will go out. About AUTO CHANGEOVER Operation AUTO: ● When AUTO CHANGEOVER operation first selected, the fan will oper- ate at very low speed for about one minute, during which time the unit detects the room conditions and selects the proper operating mode. If the differance between thermostat setting and actual room tempera- ture is more than +2 °C → Cooling or dry operation If the difference between thermostat setting and actual room tempera- ture i

  • Fujitsu ASTB24LDC, 8 2 Press the AIR CLEAN button (Fig. 6 L). The AIR CLEAN Indicator Lamp (orange) (Fig. 3 7) will light up. ● Air conditioning and Air Cleaning will function simultaneously. Air cleaning ● During operation, the unit produces a small amount of ozone that can be smelled. ● When this unit is used in combination with the ultrasonic humidifier, white parti- cles may become attached to the plasma filter unit. If this happens, clean the plasma filter unit as soon as possible. (Refer to page 14, 15.) ● The air cleaning operation cannot remove gases such as carbon monoxide and al

  • Fujitsu ASTB24LDC, 9 TIMER OPERATION s Before using the timer function, be sure that the Remote Control Unit is set to the correct current time (☞ P. 4). To Use the ON timer or OFF timer 1 Press the START/STOP button (Fig. 6 S) (if the unit is already operating, proceed to step 2). The indoor unit’s OPERATION Indicator Lamp (red) (Fig. 3 5 ) will light. 2 Press the TIMER MODE button (Fig. 6 P) to select the OFF timer or ON timer operation. Each time the button is pressed the timer function changes in the follow- ing order: CANCEL OFF ON PROGRAM(OFF → ON, OFF ← ON) T

  • 10 SLEEP TIMER OPERATION Unlike other timer functions, the SLEEP timer is used to set the length of time until air conditioner operate is stopped. To Use the SLEEP Timer While the air conditioner is operating or stopped, press the SLEEP button (Fig. 6 J). The indoor unit’s OPERATION Indicator Lamp (red) (Fig. 3 5) lights and the TIMER Indicator Lamp (green) (Fig.

  • 11 ADJUSTING THE DIRECTION OF AIR CIRCULATION ● Adjust the up, down, left, and right AIR directions with the AIR DIRECTION buttons on the Remote Control Unit. ● Use the AIR DIRECTION buttons after the Indoor Unit has started operating and the airflow-direction louvers have stopped moving. R DANGER! ● Never place fingers or foreign objects in- side the outlet ports, since the inte

  • Fujitsu ASTB24LDC, 12 To select SWING Operation Press the SWING button (Fig. 6 V). The SWING Display (Fig. 7 f) will light. Each time the SWING button is pressed, the swing operation will change in the following order. To stop SWING Operation Press the SWING button and select STOP. Airflow direction will return to the setting before swing was begun. SWING OPERATION COIL DRY OPERATION The Indoor unit can be dried by pressing the COIL DRY button on the Remote Control Unit so as to avoid going moldy and restrain the breed of bacterium. The COIL DRY Operation will operate for 20 minutes after p

  • Fujitsu ASTB24LDC, 13 Cleaning the Intake Grille 1. Remove the Intake Grille. 1 Place your fingers at both lower ends of the grille panel, and lift forward; if the grille seems to catch partway through its movement, continue lifting up- ward to remove. 2 Pull past the intermediate catch and open the Intake Grille wide so that it become horizontal. 2. Clean with water. Remove dust with a vacuum cleaner; wipe the unit with warm water, then dry with a clean, soft cloth. 3. Replace the Intake Grille. 1 Pull the knobs all the way. 2 Hold the grille horizontal and set the left and right mounting shafts into the bearings at the top of the pane

  • 14 CLEANING THE PLASMA AIR CLEANING FILTER CAUTION! WARNING! ● Make sure the plasma filter unit is properly mounted before cleaning or performing other tasks on it. If the unit is not properly mounted, it could fall off and cause damage or injury. ● You can be injured if you touch the heat exchanger when removing or installing the plasma filter unit. Do not

  • Fujitsu ASTB24LDC, 15 Cleaning the dust collection unit 5. Install the unit. (The above figure is only for reference, so the intake grille is not included.) ● Please ensure that the dust collection unit is completely dry before installing. ● After installing the dust collection unit, please ensure that it has been inserted fully into its place. If it has not been installed correctly, the OPERATION Indicator Lamp (red) and the TIMER Indicator Lamp (green) will flash, and Air Cleaning will stop. 6. Install the air filter. ● Please consult instructions for cleaning the air filter on

  • Fujitsu ASTB24LDC, 16 Air-cleaning and Deodorizing filter maintenance As well as ensuring the maintenance of the dust collecting unit, please also take care of the filter. (Please carry out maintenance on the filter every 6 months.) 1. Open the intake grille and remove the air filter from the right side. ● Please consult step 1 of cleaning the air filter on page 12. 2. Take out the unit and remove the Air- cleaning and Deodorizing filter. ● Please consult steps 2 and 3 of cleaning the air filter on page 13. 3. Air-dry after washing. 1 Wash using lukewarm or warm water. If quite dirty, wash using a mild detergent. 2 Rins

  • Fujitsu ASTB24LDC, 17 TROUBLESHOOTING WARNING! Symptom Doesn’t operate immedi- ately: Noise is heard: Smells: Mist or steam are emitted: Airflow is weak or stops: Water is produced from the outdoor unit: The AIR CLEAN Indicator Lamp (orange) will begin to slowly flash (as shown in the figure): The AIR CLEAN Indicator Lamp (orange) will begin to flash quickly (as shown in the figure): Problem ● If the unit is stopped and then immediately started again, the com- pressor will not operate for about 3 minutes, in order to prevent fuse blowouts. ● Whenever the Power Supply Plug is disconnected and then re- connected to a power outlet, the protection cir

  • Fujitsu ASTB24LDC, 18 TROUBLESHOOTING Symptom Doesn’t operate at all: Poor Cooling performance: The unit operates differently from the Remote Control Unit’s setting: See Page — 9 - 10 — 6 5 CHECK ONCE MORE Items to check ● Is the Power Supply Plug disconnected its outlet? ● Has there been a power failure? ● Has a fuse blown out, or a circuit breaker been tripped? ● Is the timer operating? ● Is the Air Filter dirty? ● Air the air conditioner’s intake grille or outlet port blocked? ● Did you adjust the room temperature settings (thermostat) cor- rectly? ● Is there a window or d

  • Fujitsu ASTB24LDC, 19 OPERATING TIPS Dry Mode About -10 to 43 °C About 18 to 32 °C Outdoor temperature Indoor temperature Cooling Mode About -10 to 43 °C About 18 to 32 °C Heating Mode About –15 to 24 °C About 30 °C or less Temperature and Humidity Range ● If the air conditioner is used under higher temperature conditioner than those listed, the built-in protection circuit may operate to prevent internal circuit damage. Also, during Cooling and Dry modes, if the unit is used under conditions of lower temperature than those listed above, the heat-exchanger ma

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Sony CDX-F7500 Service manual sony/cdx-f7500-72K.pdf 23 Dec 2023 51
2 Team Magic E4D Instruction & setup manual team-magic/e4d-6PN.pdf 01 May 2023 3
3 Fagor CR-282 User manual manual fagor/cr-282-KH7.pdf 24 Feb 2024 54 0.43 Mb
4 Nvidia P2930 Operation & user’s manual nvidia/p2930-536.pdf 31 Aug 2022 24
5 3Com 3C319 Operation & user’s manual 3com/3c319-E69.pdf 11 Feb 2024 110 1.1 Mb
6 Microtek 710S Operation & user’s manual microtek/710s-C9M.pdf 07 Dec 2022 21

Similar Resources:

  • Technibel

    GRF78R5TAA

    (25 pages)
    TECHNICAL DATA& SERVICE MANUALOUTDOOR UNIT:GRF78R5TAAGRF98R5TAAGRF128R5TAA0.8180.552.1 06/2008SPLIT SYSTEM AIR CONDITIONER GRF128R5TAA 38.7107.082Model No. Product Code No.GRF98R5TAA 38.7107.081GRF78R5TAA 38.7107.080 …
  • Toyotomi

    TAN-A28IV

    (44 pages)
    SERVICE MANUALROOM AIR CONDITIONERTAN/TAG-A28IVTAN/TAG-A32IVTAN/TAG-A53IVCONTENTSSPECIFICATION .................................................................... 1FUNCTIONS .......................................................................... 7SERVICE FUNCTION EXPLANATION .................................. 9OPERATION DETAILS........................... …
  • Gree

    13-04582

    (18 pages)
    OWNER’S MANUALCANADIAN STANDARDS3-IN-1 MOBILEAIR CONDITIONERPlease read the following owner’s manual before using this air conditioner. Keep this manual along with your proof of purchase in a safe place for future reference.MODEL : 13-0458200223-27/12/06© Copyright, Sunrise Tradex Corp., 2006 …
  • MAXA

    MI26A1

    (33 pages)
    MAXA DC Fan Coil UnitWall-mounted Technical Service Manual MAXA reserves the right to discontinue, or change specification or designs at any time without notices and without incurring obligations.MI26A1MI35A1MI42A1 …
  • General Climate

    GC/CU-S24HR

    (52 pages)
    www.generalclimate.com Wall-Mounted Split Type Service manual Room Air Conditioner Split Wall-Mounted Type GC/CU-S24HR …
  • Marstair

    CKC 20 1/50

    (17 pages)
    1 55008418-01 TECHNICAL MANUAL CKC CONDENSING UNITS …

Comments, Questions and Opinions: