Fujitsu ASTB09LDC Operating Manual
|
Fujitsu ASTB09LDC, KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED OPERATING MANUAL P/N9315231017-01 Indoor Unit ASTB09LDC ASTB12LDC Outdoor Unit AOTS09LDC AOTS12LDC HEAT & COOL MODEL (REVERSE CYCLE) ROOM AIR CONDITIONER WALL MOUNTED TYPE R410A REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A and Polyol Ester oil. THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED BY QUALIFIED PERSONNEL. Refer to Commonwealth, State, Territory and local legislation, regulations, codes, installation &am
Fujitsu ASTB09LDC, 1 CONTENTS SAFETY PRECAUTIONS ......................................... 1 FEATURES AND FUNCTIONS ............................... 2 NAME OF PARTS .................................................... 3 PREPARATION ......................................................... 5 OPERATION ............................................................. 6 AIR CLEANING OPERATION ................................. 8 TIMER OPERATION ................................................. 9 SLEEP TIMER OPERATION................................. 10 ADJUSTING THE DIRECTION OF AIR CI
Fujitsu ASTB09LDC, 2 FEATURES AND FUNCTIONS INVERTER At the start of operation, a large power is used to bring the room quickly to the desired temperature. Afterwards, the unit automatically switches to a low power setting for eco- nomic and comfortable operation. COIL DRY OPERATION The Indoor unit can be dried by pressing the COIL DRY but- ton on the Remote Control Unit so as to avoid going moldy and restrain the breed of bacterium. AUTO CHANGEOVER The operation mode (cooling, dry, heating) is switched au- tomatically to maintain the set temperature, and the t
Fujitsu ASTB09LDC, 3 – ( ¡ ¢ ª ) ™ ∞ º _ + £ § • ¶ ⁄ ‹ fi ‡ Ÿ @ # ¤ fl › K ° ≠ G H J I 5 6 4 7 8 OPERATION TIMER AIR CLEAN COIL DRY = A B D C 9 3 1 2 Fig. 5 Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 7 To facilitate explanation, the accompanying illustra- tion has been drawn to show all possible indicators; in actual operation, however, the display will only show those indicators appropriate to the current op- eration. Fig. 6 NAME OF PARTS
4 Fig. 1 Indoor Unit 1 Operating Control Panel (Fig. 2) 2 MANUAL AUTO button ● When kept on pressing the MANUAL AUTO button for more than 10 seconds, the forced cooling operation will start. ● The forced cooling operation is used at the time of installation. Only for authorized service personnel’s use. ● When the forced cooling operation starts by any chance, press th
Fujitsu ASTB09LDC, 5 PREPARATION CAUTION! ● Take care to prevent infants from accidentally swallowing batteries. ● When not using the Remote Control Unit for an extended period, remove the batteries to avoid possible leakage and damage to the unit. ● If leaking battery fluid comes in contact with your skin, eyes, or mouth, immedi- ately wash with copious amounts of water, and consult your physician. ● Dead batteries should be removed immediately and disposed of properly, either in a battery collection receptacle or to the appropriate authority. ● Do not attempt to recharge dry batteries. Never mix ne
Fujitsu ASTB09LDC, 6 To Select Mode Operation 1 Press the START/STOP button (Fig.6 N). The indoor unit’s OPERATION Indicator Lamp (red) (Fig. 3 5) will light. The air conditioner will start operating. 2 Press the MASTER CONTROL button (Fig.6 L) to se- lect the desired mode. Each time the button is pressed, the mode will change in the following order. AUTO COOL DRY HEAT FAN About three seconds later, the entire display will reappear. To Set the Thermostat Press the SET TEMP. button (Fig. 6 R). button: Press to raise the thermostat setting. button: Press to lower the thermostat setting. ●Thermostat setting range: AUTO ..
Fujitsu ASTB09LDC, 7 To Stop Operation Press the START/STOP button (Fig.6 N). The OPERATION Indicator Lamp (red) (Fig. 3 5) will go out. About AUTO CHANGEOVER Operation AUTO: ● When AUTO CHANGEOVER operation first selected, the fan will oper- ate at very low speed for about one minute, during which time the unit detects the room conditions and selects the proper operating mode. If the differance between thermostat setting and actual room tempera- ture is more than +2 °C → Cooling or dry operation If the difference betwee
Fujitsu ASTB09LDC, 8 2 Press the AIR CLEAN button (Fig. 6 O). The AIR CLEAN Indicator Lamp (green) (Fig. 3 7) will light up. ● Air conditioning and Air Cleaning will function simultaneously. Air cleaning ● During operation, the unit produces a small amount of ozone that can be smelled. ● When this unit is used in combination with the ultrasonic humidifier, white parti- cles may become attached to the plasma filter unit. If this happens, clean the plasma filter unit as soon as possible. (Refer to page 14, 15.) ● The air cleaning operation cannot rem
9 TIMER OPERATION s Before using the timer function, be sure that the Remote Control Unit is set to the correct current time (☞ P. 5). To Use the ON timer or OFF timer 1 Press the START/STOP button (Fig. 6 N) (if the unit is already operating, proceed to step 2). The indoor unit’s OPERATION Indicator Lamp (red) (Fig. 3 5 ) will light. 2 Press the TIMER M
Fujitsu ASTB09LDC, 10 SLEEP TIMER OPERATION Unlike other timer functions, the SLEEP timer is used to set the length of time until air conditioner operate is stopped. To Use the SLEEP Timer While the air conditioner is operating or stopped, press the SLEEP button (Fig. 6 S). The indoor unit’s OPERATION Indicator Lamp (red) (Fig. 3 5) lights and the TIMER Indicator Lamp (green) (Fig. 3 6) will light. To Change the Timer Settings Press the SLEEP button (Fig. 6 S) once again and set the time using the TIMER SET( / ) buttons (Fig. 6 V). Set the time while the Timer Mode Display is flashing (the flashing will continue about five seconds). button: Press to advance
11 R DANGER! ● Never place fingers or foreign objects in- side the outlet ports, since the internal fan operates at high speed and could cause personal injury. ● Always use the Remote Control Unit’s SET button to adjust the vertical airflow louvers. Attempting to move them manually could result in improper op- eration; in this case, stop operation and restart. The louvers
Fujitsu ASTB09LDC, 12 SWING OPERATION MANUAL AUTO OPERATION Use the MANUAL AUTO operation in the event the Remote Control Unit is lost or otherwise unavailable. How To Use the Main Unit Controls Press the MANUAL AUTO button (Fig. 2 2) on the main unit control panel. To stop operation, press the MANUAL AUTO button (Fig. 2 2) once again. (Controls are located inside the Open Panel) ● When the air conditioner is operated with the controls on the Main Unit, it will operate under the same mode as the AUTO mode selected on the Re- mote Control Unit (see page 7). ● The fan speed selected will be “AUTO” and
Fujitsu ASTB09LDC, 13 Cleaning the Intake Grille 1. Remove the Intake Grille. 1 Place your fingers at both lower ends of the grille panel, and lift forward; if the grille seems to catch partway through its movement, continue lifting up- ward to remove. 2 Pull past the intermediate catch and open the Intake Grille wide so that it become horizontal. 2. Clean with water. Remove dust with a vacuum cleaner; wipe the unit with warm water, then dry with a clean, soft cloth. 3. Replace the Intake Grille. 1 Pull the knobs all th
Fujitsu ASTB09LDC, 14 CLEANING THE PLASMA AIR CLEANING FILTER CAUTION! WARNING! ● Make sure the plasma filter unit is properly mounted before cleaning or performing other tasks on it. If the unit is not properly mounted, it could fall off and cause damage or injury. ● You can be injured if you touch the heat exchanger when removing or installing the plasma filter unit. Do not insert your fingers between the plasma filter unit and the heat exchanger. Before cleaning the plasma filter unit, be sure to turn off the power supply to the air conditioner. Electric shock may result. Regarding the Air Cleaning check function ● This function is illustrated by the flashing of the
Fujitsu ASTB09LDC, 15 Cleaning the dust collection unit 5. Install the unit. (The above figure is only for reference, so the intake grille is not included.) ● Please ensure that the dust collection unit is completely dry before installing. ● After installing the dust collection unit, please ensure that it has been inserted fully into its place. If it has not been installed correctly, the OPERATION Indicator Lamp (red) and the TIMER Indicator Lamp (green) will flash, and Air Cleaning will stop. 6. Install the air filter. ● Please consult instruc
16 Air-cleaning and Deodorizing filter maintenance As well as ensuring the maintenance of the dust collecting unit, please also take care of the filter. (Please carry out maintenance on the filter every 6 months.) 1. Open the intake grille and remove the air filter from the right side. ● Please consult step 1 of cleaning the air filter on page 13. 2. Take out t
Fujitsu ASTB09LDC, 17 TROUBLESHOOTING WARNING! Symptom Doesn’t operate immedi- ately: Noise is heard: Smells: Mist or steam are emitted: Airflow is weak or stops: Water is produced from the outdoor unit: The AIR CLEAN Indicator Lamp (green) will begin to slowly flash (as shown in the figure): The AIR CLEAN Indicator Lamp (green) will begin to flash quickly (as shown in the figure): Problem ● If the unit is stopped and then immediately started again, the com- pressor will not operate for about 3 minutes, in order to prevent fuse blowouts. ● Whenever the Power Supply Plug is disconnected and then re- connected to a power outlet, the protection circuit w
Fujitsu ASTB09LDC, 18 TROUBLESHOOTING Symptom Doesn’t operate at all: Poor Cooling performance: The unit operates differently from the Remote Control Unit’s setting: See Page — 9 - 10 — 6 5 Items to check ● Is the Power Supply Plug disconnected its outlet? ● Has there been a power failure? ● Has a fuse blown out, or a circuit breaker been tripped? ● Is the timer operating? ● Is the Air Filter dirty? ● Air the air conditioner’s intake grille or outlet port blocked? ● Did you adjust the room temperature settings (thermostat) cor- rectly? ● Is there a window or door open? ● In the case of Cooling operation, is a window a
Fujitsu ASTB09LDC, 19 OPERATING TIPS Dry Mode About –10 to 43 °C About 18 to 32 °C Outdoor temperature Indoor temperature Cooling Mode About –10 to 43 °C About 18 to 32 °C Heating Mode About –15 to 24 °C About 30 °C or less Temperature and Humidity Range ● If the air conditioner is used under higher temperature conditioner than those listed, the built-in protection circuit may operate to prevent internal circuit damage. Also, during Cooling and Dry modes, if the unit is used under conditions of lower temperature than those listed above, the heat-exchanger may freeze, leading to water leakage and other damage. ● Do not use this unit for any purposes other than the Cooling, Dehumidifying, and ai
Fujitsu D’EMPLOI Air Conditioner Operating manual
D’EMPLOI |
Fujitsu CDS25R Air Conditioner Operation manual
CDS25R |
Fujitsu AS*G07LECA Air Conditioner Installation/troubleshooting manual
AS*G07LECA |
Fujitsu ASYA12LGC Air Conditioner Manual
ASYA12LGC |
Fujitsu ABT series Air Conditioner Operating manual
ABT series |
Fujitsu AS*B24LDC Air Conditioner Manual
AS*B24LDC |
Fujitsu ASTA07JEC Air Conditioner Operating manual
ASTA07JEC |
Fujitsu ASU18CL Air Conditioner Service manual
ASU18CL |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Delta Electronics | GRB0912DHU | Dimensions and installation information | delta-electronics/grb0912dhu-UR4.pdf | 09 Sep 2022 | 1 | 0.31 Mb |
2 | Pyle | PWMA325BT | Instruction manual | pyle/pwma325bt-85V.pdf | 03 Nov 2022 | 4 | |
3 | Compuprint | SP40plus | Quick reference manual | compuprint/sp40plus-Z17.pdf | 05 Dec 2023 | 2 | 0.41 Mb |
4 | Lenovo | THINKPAD X31 | Setup manual | lenovo/thinkpad-x31-5S4.pdf | 24 Sep 2022 | 10 | |
5 | Philips | HTS5520 | Quick start manual | philips/hts5520-8W2.pdf | 20 Nov 2023 | 8 | |
6 | RCA | PROV700C | Operation & user’s manual | rca/prov700c-2S4.pdf | 09 Feb 2024 | 80 | 3.65 Mb |
McQuay
Floor Ceiling Air-Conditioning Unit (1.5TON - 5TON) Please read this manual carefully before using this product and keep it properly for future reference. Installation and Operation Manual Unit Model: Indoor unit MQS-24018-CFC216A MQS-24024-CFC216A MQS-24 …
MQS-24018-CFC216A(56 pages) |
Sharp
PREFACESAFETY PRECAUTIONS ...................................iINSULATION RESISTANCE TEST.....................iCHAPTER 1. PRODUCT SPECIFICATION[1] SPECIFICATION............................................ 1-1[2] WIRING DIAGRAM...................................... 1-10[3] EXTERNAL DIMENSION............................. 1-10CHAPTER 2. MICROCOMPUTER CONTROL SY …
AFS60FX - 6,000 BTU Compact Air Conditioner(32 pages) |
Mitsubishi Electric
Air Conditioning Control SystemCentralized Controller AE-200A/AE-50AAE-200E/AE-50EBefore installing the controller, please read this Installation Manual carefully to ensure proper operation.Retain this manual for future reference.Installation ManualSafety notes are marked with WARNING or CAUTION, depending on the severity of possible consequences that may re …
AE-200A(40 pages) |
Mitsubishi Electric
ENGLISHREFRIGERANT1. BEFORE INSTALLATIONWARNING5LVNRI¿UH7KLVXQLWXVHVDÀDPPDEOHUHIULJHUDQW,IUHIULJHUDQWOHDNVDQGFRPHVLQFRQWDFWZLWK¿UHRUKHDWLQJSDUWLWZLOOFUHDWHKDUPIXOJDVDQGWKHUHLVULVNRI¿UH5HDGWKH23(5$7,1*,16758&7,216FDUHIXOO\EHIRUHRSHUD …
MSY-GN50VF(8 pages) |
Gree
GREE ELECTRIC APPLIANCES,INC.OF ZHUHAIService ManualChange for Life*:+1$.11$$&ROG3ODVPD*:+1$.11%$&ROG3ODVPD*:+1$.11$$*:+1$.11'$*:+1%.11($*:+1$.11$$*:+1$.11$&*:+1$.11$$0HPEUDQD'HFRUDWLYH6WU …
GWH07NA-K3NNA4A(89 pages) |
Kenmore
Use & Care GuideManual de Uso y CuidadoEngish / EspaiolI<enmore Elite Models/Modelos: 253.76080, 253.76110, 253.76120, 253.76150ACO[IG C O_GGOP/N 2020215A1366Sears Brands Management CorporationHofl:man Estates, IL 60179 U.S.A.www.kenrnore.cornwww.sears.comwww.krnart.corn®
…
25376150410(24 pages) |
Cub Cadet Lawn and Garden Equipment 2X 945 SWELawn and Garden Equipment PDF Operator's manual 2X 945 SWE, 28 |
Avermedia Computer Hardware AVerTV 6Avermedia AVerTV 6 Guide (Operation & user’s manual), @1M739Y AVerTV 6, 60 |
Macrom Amplifier 44.50#6MN3BN 44.50: Macrom Amplifier Owner Documentation 44.50, 25 |
Fortinet Network Card FortiDB FortiDB-2000BFortinet FortiDB FortiDB-2000B Network Card Quick start manual FortiDB FortiDB-2000B, 2 |
MG Automobile 1967 Midget Mark IIIMG 1967 Midget Mark III User Manual (Doc Type: Automobile Handbook) 1967 Midget Mark III, 28 |
Asko Dryer TD25Asko Product Manual: TD25 PDF Service manual - ZXXX96 TD25, 16 |
Whirlpool Refrigerator 8ED22PWWhirlpool Product Manual: 8ED22PW PDF Use and care manual - C7UFF6 8ED22PW, 25 |
Canon Printer imagePROGRAF iPF650 Basic guide No.3Canon Printer Basic manual (File: canon-imageprograf-ipf650-basic-guide-no-3-basic-manual-20, 21/08/2023) imagePROGRAF iPF650 Basic guide No.3, 20 |
McCulloch Chainsaw MAC 538EChainsaw PDF Operator's manual MAC 538E, 14 |
Harman Kardon Amplifier PA 2000#42WS4G: PA 2000 Amplifier Owner's manual PA 2000, 16 |
Polar Electro Fitness Electronics G5Fitness Electronics #99ZR7F G5, 20 |
Miele Iron B 890PDF User Guide (@1W7K5N), Miele B 890 Iron (06.02.2024) B 890, 32 |