Manualios.com

Fujitsu PRIMERGY TX100 S2 Operating Manual

Fujitsu PRIMERGY TX100 S2 Manual Online:

4.55, 1023 votes
Fujitsu PRIMERGY TX100 S2 User Manual
Fujitsu PRIMERGY TX100 S2 User Guide
Fujitsu PRIMERGY TX100 S2 Online Manual

Text of Fujitsu PRIMERGY TX100 S2 User Guide:

  • Fujitsu PRIMERGY TX100 S2, TX100 S2 Operating Manual 19 2 Installation steps, overview This chapter contains an overview of the steps you need to carry out to install your server. Links take you to sections where you can find more detailed information about the respective steps: Ê First of all, it is essential that you familiarize yourself with the safety information in chapter "Important notes" on page 21. Ê Transport the server to the place where you want to set it up. Ê Unpack the system, check the contents of the package for visible transport damage and check whether the it

  • Fujitsu PRIMERGY TX100 S2, TX100 S2 Operating Manual 31 Important notes 3.4 ENERGY STAR The system has a hibernate mode (S4 mode) from which it can be woken up via WOL (Wake-up On LAN). In order to use this feature, however, the S4 mode must be activated/enabled in the corresponding operating system installed. The following description is an example and can only serve as a guide for other operating systems. To bring your system into S4 mode (= hibernate mode), proceed as follows: BIOS Setup Ê In the Power menu of the BIOS setup, set the

  • Fujitsu PRIMERGY TX100 S2, 46 Operating Manual T X100 S2 Installation and operation 5.1.1.1 Control elements 5.1.1.2 Indicators On/Off button When the system is switched off, it can be switched on again by pressing the On/Off button. When the system is operating, pressing the On/Off button will switch off the system. I The On/Off button does not disconnect the server from the mains voltage. To disconnect from the mains completely, remove the power plug(s). DVD eject button When the DVD drive button is pressed, the DVD drive opens or closes. Power indicator Glows green when the server is switched on. Hard disk activity indicator (green) Lights up green when an internal drive (HDD o

  • Fujitsu PRIMERGY TX100 S2, 26 Operating Manual T X100 S2 Important notes Working with CDs/DVDs/BDs and optical drives When working with devices with optical drives, these instructions must be followed. V CAUTION! ● Only use CDs/DVDs/BDs that are in perfect condition, in order to prevent data loss, equipment damage and injury. ● Check each CD/DVD/BD for damage, cracks, breakages etc. before inserting it in the drive. Note that any additional labels applied may change the mechanical properties of a CD/DVD/BD and cause imbalance. Damaged and imbalance

  • Fujitsu PRIMERGY TX100 S2, 64 Operating Manual T X100 S2 Index Error Correcting Code 13 Error Detection Code 13 error message on screen 61 expansion card 11 F fans CPU 12 power supply unit 12 system 12 fault drifting display on monitor 59 drive defective 61 incorrect date 60 incorrect time 60 no display on monitor 59 screen remains blank 58 screen shows flickering stripes 59 FCC statement 29 G graphics card 41 H hard disk activity indicator 45, 46 hard disk drive 11 hot-plug power supply unit 12, 42 I Indicators LAN 48 indicators DVD d rive 46 DVD drive activity 45 hard d

  • TX100 S2 Operating Manual 39 Installing the hardware 4.2 Setting up the server V CAUTION! Follow the safety instructions in chapter "Important notes" on page 21. Ê Set up the server. V CAUTION! – The device must be protected from direct sunlight. – Ensure that the minimum clearances (see "Ventilation clearance" on page 17) are observed. – Access to t

  • Fujitsu PRIMERGY TX100 S2, TX100 S2 Operating Manual 37 4 Installing the hardware V CAUTION! ● Follow the safety instructions in the chapter "Important notes" on page 21. ● Do not expose the server to extreme environmental conditions (see "Ambient conditions" on page 17). Protect the server from dust, humidity and heat. ● Make sure that the server is acclimatized for the time indicated in this table before putting it into operation. In the table "Acclimatization time", the temperature difference refers to the difference between the operating environment temperature

  • Fujitsu PRIMERGY TX100 S2, TX100 S2 Operating Manual 21 3 Important notes In this chapter you will find essential information regarding safety when working on your server. 3.1 Safety instructions I The following safety instructions are also provided in the manual "Safety Notes and Regulations". This device meets the relevant safety regulations for IT equipment. If you have any questions about whether you can install the server in the intended environment, please contact your sales outlet or our customer service team. V CAUTION! ● The actions described in this manual must be performed by technical specialists. ● Equipment repair

  • Fujitsu PRIMERGY TX100 S2, 14 Operating Manual T X100 S2 Preface ServerView Installation Manager You can configure the PRIMERGY server quickly and precisely with the ServerView Installation Manager software provided. User-guided menus are available for installing the server operating system (for further details see section "Configuring the server" on page 51). Service and support PRIMERGY servers are easy to maintain and modular, thus enabling quick and simple maintenance. All locks and touch points used to exchange components are colored green to ensure simple and immediate recognition. In order to prevent the components from being damaged by incorrect handling when they are being inst

  • Fujitsu PRIMERGY TX100 S2, 24 Operating Manual T X100 S2 Important notes V CAUTION! ● Proper operation of the system (in accordance with IEC 60950-1/EN 60950-1) is only ensured if the casing is completely assembled and the rear covers for the installation slots have been fitted (electric shock, cooling, fire protection, interference suppression). ● Only install system expansions that satisfy the requirements and rules governing safety and electromagnetic compatibility and those relating to telecommunication terminals. If you install other expansions, they may damage the system or violate the safety regulations. Information on which system expansions ar

  • Fujitsu PRIMERGY TX100 S2, TX100 S2 Operating Manual 65 Index R RAID controller is not configured for this drive 61 RAID level 13 recycling devices 35 redundancy, fans 12 regulations and standards 16 return of devices 35 S Safety instructions 21 safety standards 16 SAS controller 12 saving energy 34 screen error message 61 flickering 59 remains blank 58 shows flickering stripes 59 SDDC (Single Device Data Correction) 13 security function 9 Serial port COM1 40 Server LAN indicator 48 server configuration 14 configuring 51 connecting externa

  • 16 Operating Manual T X100 S2 Preface Compliance with regulations and standards Product safety and ergonomics International IEC 60950-1 Europe Safety EN 60950-1 ergonomics ISO 9241-3 EN 2941-3 EK1-ITB 2003:2007 UL 60950-1 USA / Canada CSA-C22.2 60950-1-03 Taiwan CNS 14336 China GB 4943 Electromagnetic compatibility International CISPRA 24 Europe EN 55022 EN 55024 EN 61

  • Fujitsu PRIMERGY TX100 S2, TX100 S2 Operating Manual 51 Installation and operation 5.3 Configuring the server This section contains information about configuring the server and installing the operating system. 5.3.1 Configuring the onboard SATA controller A SATA controller is integrated on the system board. You can configure the onboard SATA controller either before or during installation with the ServerView Installation Manager. Using the ServerView Installation Manager is recommended. I The controller has its own configuration utility. For further information, refer to the “Embedded MegaRAID Software User’s Guide” (on the ServerView Suite DVD 2 under Industry Standard Serve

  • Fujitsu PRIMERGY TX100 S2, 22 Operating Manual T X100 S2 Important notes Before starting up V CAUTION! ● During installation and before operating the device, observe the instructions on environmental conditions for your device (see section "Technical data" on page 15). ● If the server has been moved from a cold environment, condensation may form both inside and on the outside of the machine. Wait until the server has acclimatized to room temperature and is absolutely dry before starting it up. Material damage may be caused to the server if this requirement

  • Fujitsu PRIMERGY TX100 S2, TX100 S2 Operating Manual 25 Important notes Batteries V CAUTION! ● Incorrect replacement of batteries may lead to a risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer (see the technical manual for the system board). ● Do not throw batteries into the trash can. ● Batteries must be disposed of in accordance with local regulations concerning special waste. ● Replace the lithium battery on the system board in accordance with the instructions in the technical manual for the system board. ● All batteries con

  • Fujitsu PRIMERGY TX100 S2, TX100 S2 Operating Manual 11 Preface Further sources of information: – PRIMERGY Abbreviations and Glossary on the ServerView Suite DVD 2 – Manual for the monitor – Documentation for the boards and drives – Operating system documentation – Information files in your operating system 1.3 Performance features System board The features of the system board are described in the technical manual for the system board D2779 for the hardware and in the BIOS Setup manual for the BIOS. Slots for expansion cards The server can be flexibly expanded via four slots: – two PCIe Gen2 x8 – one PCIe Gen2 x4 – one PCI (32 Bit / 33 MHz; 3.3 V) PCIe Gen2 doubles the bandwidth o

  • Fujitsu PRIMERGY TX100 S2, TX100 S2 Operating Manual 45 5 Installation and operation V CAUTION! Follow the safety instructions in chapter "Important notes" on page 21. 5.1 Control and display elements 5.1.1 Front of server Figure 4: Front of server 1 DVD drive activity indicator 4 power-on indicator / On/Off button 2 DVD eject button 5 2 x USB port 3 hard disk activity indicator / 1 2 3 0

  • Fujitsu PRIMERGY TX100 S2, TX100 S2 Operating Manual 13 Preface High level of availability and data security When memory data is accessed, 1-bit errors are identified in the main memory and automatically corrected with the error correcting code (ECC) method. The patented memory scrubbing function regularly starts up the EDC mechanism, ensuring continuous data integrity. The onboard SATA controller supports different RAID levels and increases the a vailability and data security of the system. Server management Server management is implemented using the Ser

  • 60 Operating Manual T X100 S2 Troubleshooting and tips 7.6 Incorrect date and time Ê Set the date and time in the operating system or in the BIOS Setup under the Main menu, using System Date and System Time respectively. I Note that the operating system may affect the system time. For example, the operating system time may deviate from the system time under Linux, and would overwr

  • Fujitsu PRIMERGY TX100 S2, TX100 S2 Operating Manual 61 Troubleshooting and tips 7.8 Added drive reported as defective RAID controller is not configured for this drive Ê Reconfigure the RAID controller for the drive using the corresponding utility. For further information, refer to the "Embedded MegaRAID Software User’s Guide" (on the ServerView Suite DVD 2 under Industry Standard Servers - Expansion Cards - Storage Adapters - LSI RAID / SCSI Controllers). If the hard disk drive continues to be shown as defective, then replace it (see the "PRIMERGY TX100 S2 Options Guide"). 7.9 Error message on screen The meaning of the error messag

Related Products and Documents (Server):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Panasonic SL-SX276J Operating instructions manual panasonic/sl-sx276j-974.pdf 07 Oct 2023 8 0.36 Mb
2 Korenix JetNet 6059G Operation & user’s manual korenix/jetnet-6059g-7L9.pdf 22 Aug 2023 135
3 Massimo MSU 300 Owner's manual massimo/msu-300-923.pdf 04 Jul 2022 38
4 Holmes HFH441 Owner's manual holmes/hfh441-D94.pdf 07 Jun 2023 2 0.77 Mb
5 PulseWorx RM1-15 Installation manual and owner's manual pulseworx/rm1-15-7SM.pdf 14 Nov 2022 2
6 Patton electronics IPLink Series Software configuration manual patton-electronics/iplink-series-W8V.pdf 08 Nov 2023 331 3.22 Mb

Similar Resources:

  • ESI

    -50L

    (40 pages)
    ESI-50L Communications Server Administrator’s Manual 0450-1152 Rev. D Copyright © 2011 ESI (Estech Systems, Inc.). Ethernet is a registered trademark of Xerox Corporation. Microsoft, Windows, and Outlook are registered trademarks of Microsoft Corporation. Panasonic and DBS are registered trademarks of Matsushita Electric Corpora …
  • HP

    ProLiant DL385p Generation 8

    (57 pages)
    With enhanced innovations in performance, feature flexibility, and management capabilities, the DL385p Gen8 is the price/performancechoice for your virtualization, database, and high performance computing workloads.Front View:Rear View:1.Quick removal access panel1.PCIe Slots (Slots 1-3 top to bottom)2.Second AMD Processor2.PCIe Slots (Slots 4-6 top to bo …
  • LEIVIO

    IPVS-100 Series

    (32 pages)
    Model IPVS-100 Series LEIVIO TECHNOLOGIES, INC. MPEG-4 Encoder Manual This Manual and its contents are all © Copyright Leivio Technologies, Inc. All rights reserved. No republication, use in any form, or reproduction are allowed without prior written permission of Leivio Technologies, Inc. 473 Sapena Court • Suite 8 Santa Clara, …
  • Sony

    XDS1000

    (150 pages)
    PROFESSIONAL MEDIA STATIONXDS-1000OPERATION MANUAL [English]1st Edition (Revised 6)The supplied CD-ROM includes operation manuals for the XDS-1000 Professional Media Station (English, Japanese, French, German, Italian, Spanish and Chinese versions) in PDF format.For more details, see “Using the CD-ROM Manual” on page 15. …
  • Ebyte

    E810 Series

    (31 pages)
    EBYTE Wireless Data TransceiverE810-DTUUser ManualThis manual may change with the continuous improvement of the product. Please refer to the latest version of the instruction.Chengdu Ebyte Electronic Technology Co., Ltd. reserves all rights of final interpretation and modification of this manual. …
  • NEC

    HX4000

    (210 pages)
    ``````````````()■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■Server HX4000User’s Guide …

Comments, Questions and Opinions: