  • Fujitsu SPARC Enterprise T5440 Server, 150 SPARC Enterprise T5440 Server Service Manual • June 2011 2. Install the two No. 2 Phillips screws. 3. Plug the front control panel connector into the front I/O board. 4. Plug the front control panel connector into J9901 on the motherboard. Next Steps ■ “Install the Fan Tray Carriage” on page 134 ■ “Install a Fan Tray” on page 88 ■ “Install the Top Cover” on page 154 ■ “Install the Server Into the Rack” on page 154 ■ “Connect the Power Cords to the Server” on page 157 ■ “Power On the Server” on page 157 Servicing the Front I/O Board The front I/O board contains two USB connectors. You must remove the front control panel to service the

  • Fujitsu SPARC Enterprise T5440 Server, Preparing to Service the System 69 Caution – Because 3.3v standby power is always present in the system, you must unplug the power cords before accessing any cold-serviceable components. Extending the Server to the Maintenance Position This topic includes the following: ■ “Components Serviced in the Maintenance Position” on page 69 ■ “Extend the Server to the Maintenance Position” on page 70 Components Serviced in the Maintenance Position The following components can be serviced with the server in the maintenance position: ■ Fan trays ■ CMP/memory modules ■ FB-DIMMs ■ PCIe/XAUI cards ■ Service processor ■ Powe

  • Fujitsu SPARC Enterprise T5440 Server, Servicing Field-Replaceable Units 127 ■ “Slide the Server Into the Rack” on page 155 ■ “Connect the Power Cords to the Server” on page 157 ■ “Power On the Server” on page 157 Servicing the IDPROM The IDPROM stores system parameters, such as host ID and MAC address, ILOM configuration settings, and OpenBoot PROM configuration settings. If you are replacing a faulty service processor, you must move the IDPROM from the old service processor to the new one. ■ “Remove the IDPROM” on page 127 ■ “Inst

  • Fujitsu SPARC Enterprise T5440 Server, Managing Faults 61 set /SYS/keyswitch_state value normal | stby | diag | locked setkeyswitch [-y] value normal | stby | diag | locked • -y enables you to skip the confirmation question when setting the keyswitch to stby. Sets the virtual keyswitch. set /SUS/LOCATE value=value [Fast_blink | Off] setlocator value [on | off] Turns the Locator LED on the server on or off. (No ILOM equivalent.) showenvironment Displays the environmental status of the host server. This information includes system tem

  • Fujitsu SPARC Enterprise T5440 Server, 36 SPARC Enterprise T5440 Server Service Manual • June 2011 Related Information ■ “Diagnostic Flowchart” on page 13 ■ “Detecting Faults Using LEDs” on page 34 ■ “ILOM-to-ALOM CMT Command Reference” on page 58 ■ SPARC Enterprise T5440 Server Installation and Setup Guide ■ SPARC Enterprise T5440 Server Administration Guide ■ Integrated Lights Out Manager 3.0 Supplement for the SPARC Enterprise T5440 Server Detecting Faults (ILOM show faulty Command) Use the ILOM show faulty command to display the follo

  • Fujitsu SPARC Enterprise T5440 Server, 30 SPARC Enterprise T5440 Server Service Manual • June 2011 POST Parameters The server can be configured for normal, extensive, or no POST execution. You can also control the level of tests that run, the amount of POST output that is displayed, and which reset events trigger POST by using ILOM command variables. The keyswitch_state parameter, when set to diag, overrides all the other ILOM POST variables. The following table lists the ILOM variables used to configure POST. “POST Fault Management Flowchart” on page 23 shows how the variables work together. Parameter Values Description keyswitch_mode normal The sys

  • Fujitsu SPARC Enterprise T5440 Server, Managing Faults 25 Note – You can use the FB-DIMM DIAG buttons on the CMP module and memory module to identify faulty FB-DIMMs. See “FB-DIMM Fault Button Locations” on page 117. Once you identify which FB-DIMMs you want to replace, see “Servicing FB-DIMMs” on page 108 for FB-DIMM removal and replacement instructions. You must perform the instructions in that section to clear the faults and enable the replaced FB-DIMMs. Related Information ■ “POST Parameters” on page 30 ■ “Displaying FRU Information With ILOM” on page 27 ■ “Detecting Faults” on page 34 ■ �

  • Fujitsu SPARC Enterprise T5440 Server, 146 SPARC Enterprise T5440 Server Service Manual • June 2011 3. Unplug the flex cable-to-power supply backplane connection. 4. Unplug the flex cable-to-hard drive backplane connection. 5. Unplug the flex cable-to-DVD-ROM drive connection. 6. Unplug the flex cable-to-motherboard connection. 7. Lift the flex cable up and out of the system. ▼ Install the Flex Cable Assembly 1. Ensure the power cables are unplugged. 2. Plug in the motherboard connector. 3. Plug in the hard drive backplane connector. 4. Plug in the DVD-ROM drive connector. 5. Plug in the power sup

  • Fujitsu SPARC Enterprise T5440 Server, Servicing Field-Replaceable Units 147 6. Install the flex cable retainer. Place the retainer into position and tighten the captive No. 2 Phillips screw. 7. Plug in the power cables. Next Steps ■ “Install the Top Cover” on page 154 ■ “Slide the Server Into the Rack” on page 155 ■ “Power On the Server” on page 157

  • Fujitsu SPARC Enterprise T5440 Server, 152 SPARC Enterprise T5440 Server Service Manual • June 2011 Next Steps ■ “Install the Fan Tray Carriage” on page 134 ■ “Install a Fan Tray” on page 88 ■ “Install the Top Cover” on page 154 ■ “Install the Server Into the Rack” on page 154 ■ “Connect the Power Cords to the Server” on page 157 ■ “Power On the Server” on page 157

  • Fujitsu SPARC Enterprise T5440 Server, 28 SPARC Enterprise T5440 Server Service Manual • June 2011 EXAMPLE: Output of the show components Command With No Disabled Components EXAMPLE: Output of the show components Command Showing Disabled Components ▼ Display Individual Component Information (ILOM show Command) Use the show command to display information about individual components in the server. ● At the -> prompt, enter the show command. In EXAMPLE: show Command Output on page 29, the show command is used to get informa

  • Fujitsu SPARC Enterprise T5440 Server, Identifying Connector Pinouts 175 USB Connector Pinouts Two Universal Serial Bus (USB) ports are located on the motherboard in a double-stacked layout and can be accessed from the back panel. Two additional USB ports are located on the front panel. Pin Signal Description Pin Signal Description A1 +5 V (fused) B1 +5 V (fused) A2 USB0/1- B2 USB2/3- A3 USB0/1+ B3 USB2/3+ A4 Ground B4 Ground

  • Fujitsu SPARC Enterprise T5440 Server, Preparing to Service the System 65 Electrostatic Discharge Safety Measures This topic includes the following: ■ “Handling Electronic Components” on page 65 ■ “Antistatic Wrist Strap” on page 65 ■ “Antistatic Mat” on page 65 Handling Electronic Components Electrostatic discharge (ESD) sensitive devices, such as the motherboard, PCI cards, hard drives, and memory modules require special handling. Caution – Circuit boards and hard drives contain electronic components that are extremely sensitive to static electricity. Ordinary amounts of static electricity from clothing or the work environment c

  • 60 SPARC Enterprise T5440 Server Service Manual • June 2011 set /HOST/bootmode/value[normal|re set_nvram|bootscript=string] bootmode value [normal|reset_nvram| bootscript=string] Enables control of the firmware during system initialization with the following options: • normal is the default boot mode. • reset_nvram resets OpenBoot PROM parameters to their

  • 40 SPARC Enterprise T5440 Server Service Manual • June 2011 ▼ View System Message Log Files The error logging daemon, syslogd, automatically records various system warnings, errors, and faults in message files. These messages can alert you to system problems such as a device that is about to fail. The /var/adm directory contains several message files.

  • Fujitsu SPARC Enterprise T5440 Server, 130 SPARC Enterprise T5440 Server Service Manual • June 2011 ▼ Install the Battery 1. Place the battery into its holder on the service processor board. Ensure that the battery is oriented correctly. 2. Press the battery firmly until it snaps into place. Next Steps ■ “Install the Service Processor” on page 126 ■ “Install the Top Cover” on page 154 ■ “Slide the Server Into the Rack” on page 155 ■ “Connect the Power Cords to the Server” on page 157 ■ “Power On the Server” on page 157 Servicing the Power Distribution Board Main 12V power is connected to the motherboard through a bus bar. Standby power and other control signals are r

  • Fujitsu SPARC Enterprise T5440 Server, Please Recycle Copyright © 2008, 2011 , Oracle and/or its affiliates. All rights reserved. FUJITSU LIMITED provided technical input and review on portions of this material. Oracle and/or its affiliates and Fujitsu Limited each own or control intellectual property rights relating to products and technology described in this document, and such products, technology and this document are protected by copyright laws, patents, and other intellectual property laws and international treaties. This document and the product and technology to which it pertains are distributed under licenses restricting their use, copying, distribution, and decompilation. No part of such product

  • Managing Faults 59 ■ Integrated Lights Out Manager 3.0 Supplement for the SPARC Enterprise T5440 Server ILOM Command ALOM CMT Command Description help [command] help [command] Displays a list of all available commands with syntax and descriptions. Specifying a command name as an option displays help for that command. set /HOST/send_break_action true br

  • Fujitsu SPARC Enterprise T5440 Server, 34 SPARC Enterprise T5440 Server Service Manual • June 2011 Detecting Faults This section describes the different methods you can use to identify system faults in the server. Detecting Faults Using LEDs The server provides the following groups of LEDs: ■ Front panel system LEDs. See “Front Panel LEDs” on page 5. ■ Rear panel system LEDs. See “Rear Panel LEDs” on page 8. ■ Hard drive LEDs. See “Hard Drive LEDs” on page 84. ■ Power supply LEDs. See “Power Supply LED” on page 95. ■ Fan tray LEDs. See “Fan Tray Fault LED” on page 89. ■ Rear panel Ethernet port LEDs. See “Ethernet Port LEDs” on pag

  • Fujitsu SPARC Enterprise T5440 Server, Managing Faults 33 EXAMPLE: show Command Output EXAMPLE: show Command Output -> stop /SYS Are you sure you want to stop /SYS (y/n)? y Stopping /SYS -> start /SYS Are you sure you want to start /SYS (y/n)? y Starting /SYS -> start /SP/console ... 2007-12-19 22:01:17.810 0:0:0>INFO: STATUS: Running RGMII 1G BCM5466R PHY level Loopback Test 2007-12-19 22:01:22.534 0:0:0>End : Neptune 1G Loopback Test - Port 2 2007-12-19 22:01:22.553 0:0:0> 2007-12-19 22:01:22.542 0:0:0>Begin: Neptune 1G Loopback Test - Port

  • Fujitsu SPARC Enterprise T5440 Server, Servicing Field-Replaceable Units 145 Related Information ■ “Safety Information” on page 63 ■ “Servicing Power Supplies” on page 89 ■ “Servicing the Power Distribution Board” on page 130 ■ “Servicing the Hard Drive Backplane” on page 135 ■ “Servicing the Motherboard” on page 139 ▼ Remove the Flex Cable Assembly Before you begin, complete these tasks: ■ Read the section, “Safety Information” on page 63. ■ Power off the server, using one of the methods described in the section, “Powering Off the System” on page 67. ■ “Extend the Server to the Maintenance Position” on page 70 ■ “Perform Electrostatic Dis

  • Fujitsu SPARC Enterprise T5440 Server, Performing Node Reconfiguration 163 ▼ Reconfigure the I/O and PCIe Fabric The reconfig.pl script reconfigures the PCIe fabric to reconnect the PCIe slots and onboard devices to the CMP nodes as efficiently as possible. The reconfig.pl script also reconfigures the Solaris device names to match the new connections between the CMP modules and the PCIe devices and slots. Use the reconfig.pl script to reattach each PCIe slot and onboard device to its nearest available CMP module. To use the rec

  • Managing Faults 51 Automated Response The fault manager will attempt to remove the affected CPU from service. Impact System performance may be affected. Suggested Action for System Administrator Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>. Details The Mes

  • Managing Faults 19 FIGURE: ILOM Fault Management The service processor can detect when a fault is no longer present and clears the fault in several ways: ■ Fault recovery – The system automatically detects that the fault condition is no longer present. The service processor extinguishes the Service Required LED and updates the FRU’s PROM, indicating that the fault is no longer pre

  • Fujitsu SPARC Enterprise T5440 Server, 159 Performing Node Reconfiguration If a CMP/memory module pair develops a fault, the server can be reconfigured to run in a degraded state until the CMP/memory module is replaced. In addition, you can add CMP/memory module pairs to existing systems. However, adding or removing CMP/memory modules might affect internal hardware device addresses, as well as the device address of any external devices attached to the system such as external disk arrays and devices attached via an External I/O Expansion Unit. Depending on which CMP/memory module is added or removed, it might be necessary to manually reassign one or more I/O devices before they can function correctly in

Related Products and Documents (Server):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Scarlett SC-292 Instruction manual scarlett/sc-292-53E.pdf 13 Jan 2024 46
2 Electrex E 230 TIG Pulse Operation & user’s manual electrex/e-230-tig-pulse-QJQ.pdf 25 Feb 2023 68
3 Schumacher Racing atom Instruction manual schumacher-racing/atom-G24.pdf 19 Mar 2023 37
4 Omega Lift MagicLift 25037 Operating instructions manual omega-lift/magiclift-25037-Q1R.pdf 24 Feb 2024 9
5 Philips 20HF5473 Specifications philips/20hf5473-1IK.pdf 26 Jul 2023 3 0.49 Mb
6 Garland THE MASTER Installation and operation manual garland/the-master-LQJ.pdf 31 Jul 2023 44

Similar Resources:

  • Lantronix

    SCSxx05

    (141 pages)
    Part No. 900-287 Rev. D April 2004 SCSxx05/SCSxx20 Secure Console Server User Guide Models SCS3205, SCS4805, SCS820, SCS1620 with Firmware v4.3 and later …
  • Compaq

    AlphaServer ES40

    (32 pages)
    AlphaServer ES40Rackmount System Installation GuideOrder Number: EK–ES240–RG. B01This guide is for service providers and self-maintenancecustomers who are installing an AlphaServer ES40 systeminto an M-Series cabinet. …
  • Digi

    Connect ES 4 SB

    (2 pages)
    Quick Start GuideDigi Connect® ES®Welcome to your Digi productGet started: This guide helps you with initial product setup. Need more? Find additionalproduct support at www.digi.com/support/DigiConnectES. Or connect to the onlinedocumentation by scanning this code:Digi Technical Support: Digi offers multiple support plans to help you get the most out of yo …
  • Sun Microsystems

    SunSwift SPARCserver 1000

    (76 pages)
    SPARCserver1000SystemBoardManualPart No: 801-2900-12Revision A, October 1994Sun Microsystems Computer Corporation2550 Garcia AvenueMountain View, CA 94043U.S.A. …
  • Cisco

    ONS 15454

    (22 pages)
    CHAPTER2-1Cisco ONS 15454 Procedure Guide, R8.078-17697-012Install Cards and Fiber-Optic CableThis chapter explains how to install the Cisco ONS 15454 cards and fiber-optic cable. Before You BeginThis section lists the chapter procedures (NTPs). Turn to a procedure for applicable tasks (DLPs).1. NTP-A15 Install the Common Control Cards, page 2-2—Complete t …
  • Seyeon

    FW3170

    (10 pages)
    FW-3170 User’s Manual Part 1 4041-00 1 Seyeon Tech Co., Ltd FW-3170 User’s Manual Part 1 (Product Overview) Version 4.0 2009-3-19 Seyeon Tech Co., Ltd www.seyeon.co.kr www.flexwatch.com …

Comments, Questions and Opinions: