  • Fujitsu MAN3184MC - Enterprise 18.4 GB Hard Drive, C141-E128-01EN4 - 8 4.2 Power Supply Requirements (1) Allowable input voltage and current The power supply input voltage measured at the power supply connector pin of the IDD (receiving end) must satisfy the requirement given in Subsection 2.1.3. (For other requirements, see Items (4) and (5) below.) (2) Current waveform (reference) Figure 4.8 shows the waveform of +12 VDC. MAN3735 series MAN3367 series MAN3184 series Figure 4.8 Current waveform (+12 VDC) (3) Power on/off sequence a) The order of the power on/off sequence of +5 VDC and +12 VDC, supplied to the IDD, does not matter. b) In a system which uses the terminating resistor power supply signal (TERMPWR) on the SCSI bus, th

  • Fujitsu MAN3184MC - Enterprise 18.4 GB Hard Drive, C141-E128-01EN 6 - 3 The IDD does not reply to the SCSI bus for up to 2 seconds after the initial self-diagnostics is started. After that, the IDD can accept the I/O operation request correctly, but the received command, except the executable commands under the not ready state (such as INQUIRY, START/STOP UNIT), is terminated with the CHECK CONDITION status (NOT READY [=2]/logical unit not ready [=04-00]) during the interval from the spindle motor becomes stable to the IDD becomes ready. The executable command under the not ready s

  • Fujitsu MAN3184MC - Enterprise 18.4 GB Hard Drive, C141-E128-01EN5 - 6 Figure 5.3 Setting terminals (CN2 on MP model only) 5.3.1 SCSI ID setting (MP model only) Table 5.1 shows the SCSI ID setting. Refer to Figures 5.2 and 5.3 for terminal positioning and allocation. IMPORTANT When the SCSI ID is set using the external operator panel connector CN1, all pins listed in Table 5.1 should be open. If any of pins are shorted, unexpected SCSI ID is set. 24222018161412108642 2321191715131197531 Terminal power supply: Supply (LED signal) (IDD Reset signal) N.C. Force Single Ended: LVD mode Force Narrow: 16bit-SCSI Spin-up mode Write protect: enabled SCS

  • Fujitsu MAN3184MC - Enterprise 18.4 GB Hard Drive, x C141-E128-01EN 4.3.1 68 pin connector 16-bit SCSI model (MP model) ............................................................ 4-11 4.3.2 SCA2 type SCSI model (MC model) ............................................................................... 4-19 4.3.3 Cable connector requirements .......................................................................................... 4-20 4.3.4 External operator panel (MP model) ................................................................................ 4-22 CHAPTER 5 INSTALLATION ............................

  • Fujitsu MAN3184MC - Enterprise 18.4 GB Hard Drive, C141-E128-01EN6 - 6 CAUTION 1. Always ground yourself with a wrist strap connected to ground before handling. ESD (Electrostatics Discharge) may cause the damage to the device. 2. To prevent electrical damage to the disk drive, turn the power off before connecting or disconnecting a cable, connector, or plug. 3. Do not remove a PCA. 4. Do not use a conductive cleaner to clean a disk drive assembly. 5. Ribbon cables are marked with a colored line. Connect the ribbon cable to a cable connector with the colored wire connected to pin 1.

  • Fujitsu MAN3184MC - Enterprise 18.4 GB Hard Drive, C141-E128-01EN5 - 20 Notes: 1. The user can arbitrarily specify the following parameters according to the system requirements: • ARRE • AWRE • TB • PER 2. The user also can arbitrarily specify parameters other than the above. However, it is recommended to use the default setting in normal operations. (2) Disconnection/reconnection parameters (page code = 2) The following parameters are used to optimize the start timing of reconnection processing to transfer data on the SCSI bus at a read (READ or READ EXTENDED command) or write operation (WRITE, WRITE EXTENDED

  • Fujitsu MAN3184MC - Enterprise 18.4 GB Hard Drive, C141-E128-01EN5 - 10 5.4 Mounting Drives 5.4.1 Check before mounting Reconfirm if the setting terminals are set correctly according to Table 5.8 before mounting the MP model drive in the system cabinet. For setting terminals location, see Section 5.3. The MC model drive does not require the following check. Table 5.8 Setting check list (MP model only) No. Setting contents (Check item) Setting position Check Remarks 1 SCSI ID CN2 7 - 8 5 - 6 3 - 4 1 - 2  (SCSI ID = __) Upper bus (DB 8 to 1

  • C141-E128-01EN 5 - 1 CHAPTER 5 INSTALLATION 5.1 Notes on Handling Drives 5.2 Connections 5.3 Setting Terminals 5.4 Mounting Drives 5.5 Connecting Cables 5.6 Confirming Operations after Installation and Preparation for Use 5.7 Dismounting Drives 5.8 Spare Disk Drive This chapter describes the notes on handling drives, connections, setting switches and plugs, mounting drives, connectin

  • Fujitsu MAN3184MC - Enterprise 18.4 GB Hard Drive, C141-E128-01EN 1 - 3 Note: The maximum data transfer rate in asynchronous mode may be limited by the response time of initiator and the length of SCSI bus length. The maximum data transfer rate in synchronous mode may be limited by the cable length, transmission characteristics of the SCSI bus and the connected SCSI device number. (5) Continuous block processing The addressing method of data blocks is logical block address. The initiator can access data by specifying block number in a logically continuous data space without concerning the physical structure of the track or cylinder boundaries. The continuous processing up to [64K-1] blocks in a command can be achieved, and

  • Fujitsu MAN3184MC - Enterprise 18.4 GB Hard Drive, C141-E128-01EN vii Task Alert message Page Mounting Installation protection fuse of the terminating resistor power supplier may be blown or the cable may be burnt if overcurrent protection is not provided. When the recommended parts listed in Table 4.2 are used, inserting the cables in the wrong direction can be prevented. 2. To connect SCSI devices, be careful of the connection position of the cable. Check that the SCSI device with the terminating resistor is the last device connected to the cable. Data loss When the SEND DIAGNOSTIC command terminates with the CHECK CONDITION status, the INIT must collect the error information using the REQUEST SENSE command. The

  • Fujitsu MAN3184MC - Enterprise 18.4 GB Hard Drive, C141-E128-01EN1 - 6 Figure 1.2 MAN series MP model outer view (1) Disks The disks have an outer diameter of 84 mm (3.3 inch) outer diameter and 25 mm (0.98 inch) inner diameter for MAN series. The disks are good for at least 20,000 contact starts and stops. Each model contains following number of disks. MAN3735: 4 MAN3367: 2 MAN3184: 1

  • Fujitsu MAN3184MC - Enterprise 18.4 GB Hard Drive, C141-E128-01EN 4 - 13 (4) Connector for external operator panel • Connector for 16-bit SCSI external operator panel CN1 provides connector for the external operator panel other than the SCSI bus as shown in Figure 4.16. Also, a connector for the external operator panel are provided on the IDD as shown in Figure 4.17. This allows connection of an external LED on the front panel, and an SCSI ID setting switch. For the recommended circuit of the external operator panel, see Subsection 4.3.4. Figure 4.16 External operator panel connector (CN1) Pin Signal A1 –ID0 A2 Fault LED A3 –ID1 A4 ESID A5 –ID2 A6 (Reserved) A7 –ID3 A8 –L

  • Fujitsu MAN3184MC - Enterprise 18.4 GB Hard Drive, C141-E128-01EN A - 1 APPENDIX A LOCATIONS OF CONNECTORS AND SETTING TERMINALS A.1 Locations of Connectors and Setting Terminals (MAN series MC model) A.2 Locations of Connectors and Setting Terminals (MAN series MP model) This appendix shows the locations of connectors and setting terminals.

  • Fujitsu MAN3184MC - Enterprise 18.4 GB Hard Drive, C141-E128-01EN6 - 4 When an error is detected in the self-diagnostics, the IDD terminates the SEND DIAGNOSTIC command with the CHECK CONDITION status. At this time only when an error is detected in the hardware function test, the LED on the front panel of the disk drive blinks. The INIT should issue the REQUEST SENSE command when the CHECK CONDITION status is posted. The sense data collected by the REQUEST SENSE command indicates the detail information of the error detected in the self-diagnostics.

  • Fujitsu MAN3184MC - Enterprise 18.4 GB Hard Drive, C141-E128-01EN 8 - 1 CHAPTER 8 PRINCIPLE OF OPERATION 8.1 Outline 8.2 Disk Drive Configuration 8.3 Circuit Configuration 8.4 Power-On Sequence 8.5 Factory-Calibration 8.6 Read/Write Circuit 8.7 Servo Control This chapter explains the general design concepts of the disk drive. It also explains the main parts, sequences, servo control method, and the main electrical circuits of the drive at the block level. 8.1 Outline The principle of operation of this disk drive can be divided into two parts. The first part explains the mechanical parts of the drive (see Section 8.2). The se

  • Fujitsu MAN3184MC - Enterprise 18.4 GB Hard Drive, FUJITSU LIMITED Storage Products Group 4-1-1 Kamikodanaka, Nakahara-ku, Kawasaki, 211-8588, Japan TEL: 81-44-754-2130 FAX: 81-44-754-8346 FUJITSU COMPUTER PRODUCTS OF AMERICA, INC. 2904 Orchard Parkway, San Jose, California 95134-2009, U.S.A. TEL: 1-408-432-6333 FAX: 1-408-894-1709 FUJITSU CANADA INC. 2800 Matheson Blvd. East, Mississauga, Toronto, Ontario L4W 4X5, CANADA TEL: 1-905-602-5454 FAX: 1-905-602-5457 FUJITSU EUROPE LIMITED Hayes Park Central, Hayes End Road,, Hayes, UB4 8FE, U.K. TEL: 44-20-8573-4444 FAX: 44-20-8573-2643 FUJITSU DEUTSCHLAND GmbH Frankfurter Ring 211, 80807 München, GERMANY TEL: 4

  • Fujitsu MAN3184MC - Enterprise 18.4 GB Hard Drive, C141-E128-01EN 4 - 9 Figure 4.9 Power on/off sequence (1) c) In a system which does not use the terminating resistor power supply signal (TERMPWR) on the SCSI bus, the requirements for +5 VDC given in Figure 4.10 must be satisfied between the IDD and the SCSI device with the terminating resistor circuit. Figure 4.10 Power on/off sequence (2) d) Between the IDD and other SCSI devices on the SCSI bus, the +5 VDC power on/off sequence is as follows: • In a system with its all SCSI devices designed to p

  • C141-E128-01EN 3 - 3 Table 3.1 Zone layout and track capacity (MAN series) Cylinder Zone MAN3735 series MAN3367 series MAN3184 series Byte/track Sector/track 0 0 - 500 503,342 737 1 501 - 2,301 485,746 720 2 2,302 - 4,102 485,746 720 3 4,103 - 5,983 476,708 696 4 5,984 - 7,884 464,618 680 5 7,885 - 9,885 448,818 660 6 9,886 - 11,886 438,224 640 7 11,887 - 13,307 431,162 630 8

  • Fujitsu MAN3184MC - Enterprise 18.4 GB Hard Drive, vi C141-E128-01EN Important Alert Items Important Alert Messages The important alert messages in this manual are as follows: A hazardous situation could result in minor or moderate personal injury if the user does not perform the procedure correctly. This alert signal also indicates that damages to the product or other property may occur if the user does not perform the procedure correctly. Task Alert message Page Mounting Installation Data loss For MAN series, Reed Solomon codes are applied for their ECC. The sector-data is divided into 6 interleaving sectors, and ECC is performed in each sector where the maximum number of errors (up to 5 byte)

  • Fujitsu MAN3184MC - Enterprise 18.4 GB Hard Drive, C141-E128-01EN 4 - 17 Figure 4.19 Output signal for external LED e. –WTP: Input signal (CN1-A12 and CN2-9, 10 pin) By connecting the CN1-A12 and CN2-10 pins to the GND, writing operations into the IDD disc media are set to disable.

Related Products and Documents (Storage):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Electrolux ER 7250B Installation and instruction manual electrolux/er-7250b-Y2W.pdf 21 Feb 2023 22 0.99 Mb
2 EAW CAZ2500 Specifications eaw/caz2500-54F.pdf 28 Aug 2023 4 0.18 Mb
3 QSC UF-3 Owner's manual qsc/uf-3-JBJ.pdf 26 Jun 2023 14 0.25 Mb
4 Fast Forward Video Micron HD Operation & user’s manual fast-forward-video/micron-hd-31X.pdf 06 Aug 2023 24
5 Whirlpool Gold GSW9550KQ0 Use and care manual whirlpool/gold-gsw9550kq0-5GL.pdf 17 Jan 2024 12 0.41 Mb
6 Philips 14PT4131/55R Technical specifications philips/14pt413155r-7I4.pdf 26 Nov 2023 2

Similar Resources:

  • Sun Microsystems

    StorEdge Series

    (2 pages)
    Copyright 1998 Sun Microsystems,Inc.Allrightsreserved. Use is subject to license terms. Third-partysoftware,includingfonttechnology, is copyrighted and licensed fromSunsuppliers.Sun,SunMicrosystems,theSunLogo,SunStorEdge,andSolarisare trademarks or registered trademarks of SunMicrosystems,Inc.intheU.S.andothercountries.RESTRICTEDRIGHTS:Use,duplication,ordisc …
  • Ezquest

    Cobra B03360

    (1 pages)
    Cobra Ultra SCSI 320 Hard Drives Welcome to the ultimate in performance storage. EZQuest Cobra Ultra SCSI 320 Hard Drives are the fastest hard drives available. The Ultra 320 drives spin at up to 15,000 RPM and can transfer data at up to 840 Mbits / s. These drives are the perfect solution for people who need extreme performance and reliability Such as …
  • iStorage

    diskAshur2

    (2 pages)
    Your diskAshur2 undergoes a rapid self-test to verify all security components are working properly each time you plug into a powered USB port. The LEDs will go through 3 test stages, blinking in sequence RED, GREEN and BLUE, followed by two GREEN blinks and then to RED (Standby State) on a successful test. Any test failure will force the diskAshur2 to secure …
  • Sabrent

    Computer Drive

    (2 pages)
    Page 1 Congratulations on your purchase of the new Sabrent USB 2.0 Hard Drive Enclosure! The enclosure provides a secure and lightweight method of transporting and transferring large quantities of data at the fast USB 2.0 speeds, while still being reverse compatible with USB 1.1. Your computer will quickly detect and configure the connected Hard Drive (Pl …
  • Asus

    Leather External HDD

    (2 pages)
    External Hard Disk Drive繁體中文注意 : • 圖示僅供參考。• 當外接硬碟機轉作時,請勿移動外接硬碟機。• 此外接硬碟機由USB連接埠供電。USB 連接 (USB 2.0 / USB 3.0)將附贈的 USB 線的兩端分別連接到外接硬碟機及電腦的USB連接埠。注意 : • USB3.0 …
  • Eleaf

    iStick

    (2 pages)
    Notice for UseThank you for choosing Eleaf products! Please read this manual carefully before use so as to use correctly. If you require additional information or have questions about the product or its use, please consult your local agents, or visit our website at www.eleafworld.com.Product IntroductioniStick is an knock-out product implementing the latest …

Comments, Questions and Opinions: