Fujitsu MAT3300NC/NP Product/ Product/maintenance Manual

  • MAT3300NC/NP Product/ Storage
  • mahizLrORRP7I
  • Product/maintenance Manual
  • PDF / Adobe Acrobat Reader
  • 130

Fujitsu MAT3300NC/NP Product/ Manual Online:

3.15, 2193 votes
Fujitsu MAT3300NC/NP Product/ User Manual
Fujitsu MAT3300NC/NP Product/ User Guide
Fujitsu MAT3300NC/NP Product/ Online Manual

Text of Fujitsu MAT3300NC/NP Product/ User Guide:

  • 6-10 C141-E201 IMPORTANT When the revision number is changed after the drive is shipped from the factory, Fujitsu issues "Engineering Change Request/Notice" in which the new revision number is indicated. When the user changes the revision number, the user should update the revision label as described in item (2) after applying the modification. Re

  • Fujitsu MAT3300NC/NP Product/, x C141-E201 4.3.3 Cable connector requirements .......................................................................................... 4-20 4.3.4 External operator panel (on NP model drives only) ......................................................... 4-21 CHAPTER 5 INSTALLATION.............................................................................................. 5-1 5.1 Notes on Handling Drives ................................................................................................ 5-1 5.2 Connections .........................................

  • Fujitsu MAT3300NC/NP Product/, C141-E201 2-7 2.2 SCSI Function Specifications Table 2.4 shows the SCSI functions provided with the IDD. Table 2.4 SCSI function specifications Item Specification Single-ended type Ο HVD type (High Voltage Differential) × LVD type (Low Voltage Differential) Ο Single-ended type Position where the terminating resistor is mounted on the PCA × Differential type Position where the terminating resistor is mounted on the PCA × Electrical requirements (*1) TERMPWR signal send function Ο (NP model) 68 pin P cable connector Ο

  • Fujitsu MAT3300NC/NP Product/, 5-12 C141-E201 5.5 Connecting Cables Connect the IDD and system with the following cables. See Section 4.3 for further details of the requirements for IDD connector positions and connecting cables. • Power cable • SCSI cable • External operator panel cable (if required for NP model) The general procedures and notes on connecting cables are described below. Especially, pay attention to the inserting orientation of each cable connector. CAUTION Damage 1. Make sure that system power is off before connecting or disconnecting cables. 2. Do not connect or disconnect cables when power is on. (except NC model) a) Connect power cable. b) Con

  • Fujitsu MAT3300NC/NP Product/, 6-14 C141-E201 Table 6.2 System-level field troubleshooting Item Recommended work DC power cable Check that the power cable is correctly connected to the disk drive and power supply unit. Check that the DC voltage is within the specified range (±5%). Check that the +5 VDC value (pins 3 and 4 of the power connector) is 4.75 to 5.25 VDC. DC power level Check that the +12 VDC supply (pins 1 and 2 of the power connector of disk drive) is 11.4 to 12.6 VDC. Make sure the maximum ripple peak-to-peak value of +5 VDC is within 250 mV and +12 VDC is within 250 mV. Electrical noise Make sure the high frequency noise (over 20 MHz) is less than 100 mVp-

  • Fujitsu MAT3300NC/NP Product/, vi C141-E201 Task Alert message Page Damage 1. Be careful of the insertion orientation of the SCSI connectors. With the system in which terminating resistor power is supplied via the SCSI cable, if the power is turned on, the overcurrent protection fuse of the terminating resistor power supplier may be blown or the cable may be burnt if overcurrent protection is not provided. When the recommended parts listed in Table 4.2 are used, inserting the cables in the wrong direction can be pr

  • Fujitsu MAT3300NC/NP Product/, 2-4 C141-E201 2.1.3 Environmental specifications Table 2.3 lists environmental and power requirements. Table 2.3 Environmental/power requirements Specification Item MAT3300NC/NP MAT3147NC/NP MAT3073NC/NP Operating 5 to 55°C Non-operating –40 to 70°C Transport (within a week) –40 to 70°C DE surface temperature at operating 5 to 60°C Temperature (*1) Gradient 15°C/h or less Operating 5 to 95%RH Non operating 5 to 95%RH Transport (within a week) 5 to 95%RH Relative humidity Maximum wet bulb temperature 29°C (no condensation) Operating (*3) 0.6 mm (5 to 20Hz)/9.8 m/s 2 (1G

  • Fujitsu MAT3300NC/NP Product/, 5-10 C141-E201 5.3.3 Mode settings In addition to the previously described settings using setting terminals, the IDD is provided with several mode settings. The mode settings are enabled by specifying the CHANGE DEFINITION command. Table 5.7 lists the mode settings and their settings at factory shipment. Refer to Section 3.1.4 of the SCSI Logical Interface Specifications for details of the command. Table 5.7 Default mode settings (by CHANGE DEFINITION command) Mode setting Contents SCSI level SCSI-3 SYNCHRONOUS DATA

  • Fujitsu MAT3300NC/NP Product/, C141-E201 6-9 6.2.4 Revision numbers The revision number of the disk drive is represented with a letter and a number indicated on the revision label attached to the DE. Figure 6.1 shows the revision label format. Figure 6.1 Revision label (1) Indicating revision number at factory shipment When the disk drive is shipped from the factory, the revision number is indicated by deleting numbers in the corresponding letter line up to the corresponding number with = (see Figure 6.2). (2) Changing revision number in the field To change the revision numbe

  • C141-E201 1-1 CHAPTER 1 GENERAL DESCRIPTION 1.1 Standard Features 1.2 Hardware Structure 1.3 System Configuration This chapter describes the feature and configuration of the intelligent disk drives (IDD). IDDs are high performance large capacity 3.5 type fixed disk drives with an embedded SCSI controller. The MAT series disk drives support the Small Comp

  • Fujitsu MAT3300NC/NP Product/, 5-14 C141-E201 d) If an error is detected in initial self-diagnosis the LED blinks. In this case, it is recommended to issue the REQUEST SENSE command from the initiator (host system) to obtain information (sense data) for error analysis. IMPORTANT The LED lights during the IDD is executing a command. However, in same commands, the lighting time is only an instant. Therefore, it seems that the LED blinks or the LED remains off. 5.6.2 Checking SCSI connection When the initial operation is checked normally after power is turne

  • Fujitsu MAT3300NC/NP Product/, C141-E201 FOR SAFE OPERATION Handling of This manual This manual contains important information for using this product. Read thoroughly before using the product. Use this product only after thoroughly reading and understanding especially the section “Important Alert Items” in this manual. Keep this manual handy, and keep it carefully. FUJITSU makes every effort to prevent users and bystanders from being injured or from suffering damage to their property. Use the product according to this manual. IMPORTANT NOTE TO USERS READ THE ENTIRE MANUAL

  • Fujitsu MAT3300NC/NP Product/, 5-20 C141-E201 5. The saved value of the MODE SELECT parameter is assumed as the initial value of each parameter after the power-on, the RESET condition, or the BUS DEVICE RESET message. The INIT can change the parameter value temporary (actively) at any timing by issuing the MODE SELECT or MODE SELECT EXTENDED command with specifying "0" to the SP bit in the CDB. (1) Error recovery parameter The following parameters are used to control operations such as IDD internal error recovery:

  • Fujitsu MAT3300NC/NP Product/, C141-E201 6-7 (3) Parts that can be replaced in the field The PCA cannot be replaced in the field. The DE cannot be replaced in the field. (4) Service system and repairs Fujitsu has the service system and repair facility for the disk drive. Contact Fujitsu representative to submit information for replacing or repairing the disk drive. Generally, the following information must be included: a) IDD model, part number (P/N), revision number, serial number (S/N), and date of manufacturing b) Error status • Date when the error occurred • System configuration • Environmental cond

  • Fujitsu MAT3300NC/NP Product/, 3-8 C141-E201 3.1.5 Format capacity The size of the usable area for storing user data on the IDD (format capacity) varies according to the logical data block or the size of the spare sector area. Table 3.1 lists examples of the format capacity when the typical logical data block length and the default spare area are used. The following is the general formula to calculate the format capacity. [Number of sectors of each zone] = [number of sectors per track × number of tracks per cell – number of alternate spare sectors per cell] × [number of cells in the zone] [Formatted capacity] = [total o

  • Fujitsu MAT3300NC/NP Product/, 4-16 C141-E201 (5) External operator panel connector Signals a. 16-bit SCSI –ID3, –ID2, –ID1, –ID0: Input signals (CN1-A1, A3, A5, A7 pin and CN2-02, 04, 06, 08 pin) These signals are used for providing switches to set the SCSI ID of the IDD externally. Figure 4.20 shows the electrical requirements. For the recommended circuit examples, see Subsection 4.3.4. Figure 4.20 16-bit SCSI ID external input

  • Fujitsu MAT3300NC/NP Product/, C141-E201 4-19 (6) Cable connection requirements The requirements for cable connection between the IDD, host system, and power supply unit are given in Figure 4.22. Recommended components for connection are listed in Table 4.2. Figure 4.22 SCSI cables connection External operator panel (example)

  • Fujitsu MAT3300NC/NP Product/, 1-4 C141-E201 (8) Command queuing feature The IDD can queue maximum 128 commands, and optimizes the issuing order of queued commands by the reordering function. This feature realizes the high speed processing. (9) Reserve and release functions The IDD can be accessed exclusively in the multi-host or multi-initiator environment by using the reserve and release functions. (10) Error recovery The IDD can try to recover from errors in SCSI bus or the disk drive using its powerful retry processing. If a recoverable data check occurs, error-free data can be transferred to the initiator after being corrected in the data buffer. The initiator softw

  • C141-E201 5-11 5.4 Mounting Drives 5.4.1 Check before mounting Reconfirm if the setting terminals are set correctly according to Table 5.8 before mounting the NP model drives in the system cabinet. For setting terminals location, see Section 5.3. The NC model drives do not require the following check. Table 5.8 Setting check list (NP model only) No. Setti

  • Fujitsu MAT3300NC/NP Product/, 3-2 C141-E201 Alternate Cylinder Note: Spare sectors on the last track in each cylinder are not necessarily placed at the end of the track because of a track skew or a cylinder skew. (Details are explained in Subsection 3.1.3.) Cylinder – 143 to Cylinder – 4 User space (Primary Cylinder 0 - (n - 1)) System space Internal test space Cylinder – 154 to Cylinder – 147 • SA0 SA139 Internal test cylinder ~ ~ ~ ~ ~ ~ ~ ~ User Space for Cell 0-0 Spare Sectors per Cell 0-0 User Space for Cell 1-0 Spare Sectors per Cell 1-0 User Space for Cell P1-0 Spare Sectors per Cell

  • C141-E201 5-3 5.2 Connections Figure 5.1 shows examples of connection modes between the host system and the IDD. For the 16- bit SCSI, up to 16 devices including the host adapter, IDD, and other SCSI devices can be connected to the SCSI bus in arbitrary combinations. Install a terminating resistor on the SCSI device connected to both ends of the SCSI cable. See Section 4.4 for

Related Products and Documents (Storage):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Dell PowerEdge R220 Technical manual dell/poweredge-r220-372.pdf 07 Sep 2023 48 1.34 Mb
2 ZyXEL Communications IPC3605N Operation & user’s manual zyxel-communications/ipc3605n-OUG.pdf 03 Dec 2023 91 1.57 Mb
3 Gossen MetraWatt BD 232 Operating instructions manual gossen-metrawatt/bd-232-KW3.pdf 21 Aug 2022 28 0.4 Mb
4 Jenn-Air JRS203 Operation & user’s manual jenn-air/jrs203-78Y.pdf 28 Jan 2023 13
5 Jenn-Air W10676381C Installation instructions manual jenn-air/w10676381c-S4I.pdf 02 Mar 2024 20
6 Insignia NS-KP04 Manual d'installation rapide insignia/ns-kp04-YNC.pdf 24 Oct 2022 2

Similar Resources:

  • IBM

    DS3000

    (602 pages)
    Draft Document for Review August 30, 2007 12:59 am SG24-7065-00ibm.com/redbooksFront coverIBM System Storage DS3000:Introduction and Implementation GuideJure ArzensekCharlotte BrooksHendrik ErnstDaniel KoeckSample configurations with step by step instructionsConfiguration and administration with Storage ManagerDS3200, DS3300, DS3400, and EXP3000 …
  • morse

    MORCINCH 4556-P

    (2 pages)
    The Specialist In Drum Handling EquipmentKit # 4556-P Kit, Bracket Assembly, MORCINCHTMCopyright 2019 - Morse Mfg. Co., Inc. Form PL4556 (0209-____) (Updated 17 Jun, 2019 4:06 PM) 1Operator’s Manual for Morse MORCINCHTM Bracket Assembly Kit - Part # 4556-PSerial Number 0209 to ____ (MMYY)ITEM QTY. PART # DESCRIPTION1 1 1371-P HOLD DOWN, BRACKET ASM …
  • Husky

    H63MWC11FT

    (10 pages)
    Husky 63 in. 11-Drawer Mobile Work BenchUSE AND CARE GUIDE Questions, problems, missing parts? Before returning to the store, call Husky Customer Service8 a.m – 7 p.m., EST, Monday-Friday9 a.m – 6 p.m., EST, Saturday Black Unit SKU#Red Unit SKU #Black Unit Model # H63MWC11FTRed Unit Model # H63MWC11RFTTHANK YOUWe appreciate the trust and condence you …
  • NASdeluxe

    NDL-2755T

    (6 pages)
    V1.0Quick Installation GuideGuide d’Installation RapideKurzanleitungGuida rapida all’installazione Guía de instalación rápidaNASdeluxe NDL-2755TiSCSI/NAS System …
  • Nexsan

    UNITY6900

    (8 pages)
    This document provides installation steps for racking, cabling, and setting up the Nexsan UNITY6900 Storage System, and cabling all Nexsan storage components for power and data/host connectivity. For additional documentation please visit http://helper.nexsansupport.com/unt_support.html1Firmware Version 6.0Quick Start GuideNEXSAN UNITY6900 Storage SystemTakin …
  • EMC2

    VNXe3100

    (6 pages)
    This document describes how to replace a solid state disk (SSD) in a VNXe3100 or VNXe3150 disk processor enclosure (DPE). Before you startBefore you start the procedure, refer to your EMC® VNXe™ online help (Servicing your system > Adding or replacing faulted hardware components > Replace a faulted hardware component) for instructions on how to iden …

Storage Instructions:

Comments, Questions and Opinions: