Manualios.com

Randell 2010FMJB Owner's Manual

Randell 2010FMJB Manual Online:

4.65, 1243 votes
Randell 2010FMJB User Manual
Randell 2010FMJB User Guide
Randell 2010FMJB Online Manual

Text of Randell 2010FMJB User Guide:

  • Randell 2010FMJB, Randell Manufacturing, Inc. OWNERS MANUAL This manual provides information on installation, operating, maintenance, troubleshooting & replacement parts for JACK IN THE BOX MODEL 2010FMJB REACH-IN NOTIFY CARRIER OF DAMAGE AT ONCE. It is the responsibility of the consignee to inspect the container upon receipt of same and to determine the possibility of any damage, including concealed damage. Randell suggests that if you are suspicious of damage to make a notation on the delivery receipt. It will be the responsibility of the consignee to file a claim with the carrier. We recommend that you do so at once. 520 S. Coldwater Road Weidman MI 48893-9683 Phone 1-800-62

  • Randell 2010FMJB, TABLE OF CONTENTS Page 2 …………………………………………………………Congratulations Page 3 …………………………………………….. Factory Correspondence Page 4 ………………………………………………. Serial Number Location Page 5 ……………………………………………………. Unit Specifications Page 8 …… ……………………………………… Randell Limited Warranty Page 11 ……………………… ……………………………… Unit Installation Page 15 …………�

  • Randell 2010FMJB, Congratulations on your recent purchase of Randell food service equipment, and welcome to the growing family of satisfied Randell customers. Our reputation for superior products is the result of consistent quality craftsmanship. From the earliest stages of product design, to successive steps in fabrication and assembly, rigid standards of excellence are maintained by our staff of designers, engineers, and skilled employees. Only the finest heavy-duty materials and parts are used in the production

  • Randell 2010FMJB, RANDELL MANUFACTURING SERIAL NUMBER LOCATION FOR THE 2000 SERIES This is a sample of a serial number tag. The serial number tag on the 2000 series is located inside the refrigerated base on the far left side of the unit.

  • Randell 2010FMJB, Unit Specifications For The 2000 Series 2010 SERIES LEDOM LDH SROODCIBUC TEEF SEVLEHS TF.QS/YTQ PHRH/UTBTLOVPMAAMENPIHS TW BJMF0102"03"13"962 6.02'52.51/4½*08121/06/5113.9P51-5573 *Based on 90F ambient evaporator for -10F freezers

  • Randell 2010FMJB, Randell Manufacturing, Inc. Warranty Policies Parts Warranty Randell warrants all component parts of manufactured new equipment to be free of defects in material or workmanship, and that the equipment meets or exceeds reasonable industry standards of performance for a period of one year from the date of shipment from any Randell factory, assembly plant or warehouse facility. Note: Warranties are effective from date of shipment, with a thirty day window to allow for shipment, installation and set up. In the event equipment was shipped to a site other than the fi

  • United States installations only: Randell will pay for the replacement compressor only. Freight, labor, refrigerant, handling and all other miscellaneous charges are the responsibility of the customer. Randell will fulfill its warranty obligation by using one of the four methods provided below, which will be selected by the Randell in house service technician: 1. Provide reimbursement to servi

  • Randell 2010FMJB, Randell does not cover gaskets under warranty. Gaskets are a maintenance type compo- nent that are subject to daily wear and tear and are the responsibility of the owner of the equipment. Because of the unlimited number of customer related circumstances that can cause gasket failure all gasket replacement issues are considered non-warranty. Randell recommends thorough cleaning of gaskets on a weekly basis with a mild dish soap and warm water. With proper care Randell gaskets can last up to two years, at which time we recommend replacement of all gaskets on the equipment for t

  • Randell 2010FMJB, Unit Installation A. Receiving Shipment Upon arrival, examine the exterior of the shipping crate for signs of abuse. It is advisable that the shipping crate be partially removed, in order to examine the cabinet for any pos- sible concealed damages which might have occurred during shipment. If no damages are evident, replace the crate in order to protect the unit during storage and local delivery. If the unit is damaged, it should be noted on the delivery slip or bill of lading and signed to that effect. A claim must be filed immediately against the carrier indicating the extent and esti- mated cost of damage occurred. B. Electrical Supply The wiring should be

  • Randell 2010FMJB, D. Locating Your New Unit The following conditions should be considered when selecting a location for your unit: 1. Floor load - The area on which the unit will rest must be free of vibration and suitably strong enough to support the combined weights of the unit plus the maximum product load weight, which are provided in the table belolow: LEDOMTFCIBUCROTCAFSDNUOPTHGIEWYTICAPACLATOT BJMF01026.025357300511 2. Clearance - There must be a combined total of at least 3" clearance on all sides of the unit. 3. Ventilation - The air cooled self contained unit requires a sufficient amount of cool clean air. Avoid placing the unit

  • Randell 2010FMJB, Figure B - Temperature control adjustments The control knob allows for temperature adjustments,with in the cabinet only. Turning the knob clockwise will result in increased cooling. Keep the arrow on the knob pointed within the green arc. Turning it clockwise beyond the green can result in freeze-up, while turning it counterclockwise beyond the green will shut the compressor off. If your cabinet tempera- ture remains to warm and your temperature control is at the maximum setting you may need to adjust the pressure control. Your units pressure control should be set at the time of installation by a qualified installation contractor. If minor adjust

  • Randell 2010FMJB, Unit Operation Randell has attempted to preset the cold control for an average interior temperature of 38°F at the factory but due to varying ambient conditions, including elevation, food product as well as type of operation you may need to alter this temperature. Additional adjustments can be made (within limits) by turning the control dial up or down until the desired tempera- ture is reached. The control dial is located on the evaporator housing inside the base. Your reach-in will maintain proper temperatures when utilized p

  • Randell 2010FMJB, Recommended cleaners for your stainless steel include the following: BOJTNEGAGNINAELCSTNEMMOC gninaelcenituoR noilladeMtnegreted,ainomma,paoShtolcroegnopsahtiwylppA sraemsdnastnirpregniFenihsocE,uN-O-caL,02lacrAmlifreirrabasedivorP noitarolocsiddnasniatsnrobbutS noisserpmitsriF,duZ,claT,oemaC senilhsilopehtfonoitceridehtnibuR no-tnrub,doolb,sdicayttafdnaysaerG sdoof dianevO,tIesaerg-eD,ffO-ysaEsehsinifllanolavomertnellecxE liodnaesaerGtnegretedlaicremmocdoogynAhtolcroegnopsahtiwylppA noitavissaP/noitarotseRneehSrepuS,tifeneBylhtnomaedidooG Reference: Nickel Development Institute, DiverseyLever, Savin, Ecolab, NAFEM Do not use steel pads, wire brushes, scrapers or chloride cleaners to cle

  • Randell 2010FMJB, 1. Cleaning condenser coil. An accumulation of dirt and dust prevents the condenser coil from removing, making your unit cool poorly, run constantly, or even stop completely if the compressor overheats. Clean coil using a vacuum cleaner with a wand attachment. If the coil is greasy, wash it with warm soapy water and a bristle brush, taking care not to drip water on other parts of your unit. 2.Cleaning drain and drain pan. Clean the drain using an oven baster to force a solution of hot water and baking soda or bleach into the opening. To cl

  • Randell 2010FMJB, 3. Checking the door seal. Open the door and examine all four sides of the door gasket for tears. Feel the gasket for brittleness or cracks. If the gasket shows damage replace it. If not, close the door and check the seal between gasket and cabinet for obvious gaps. Next open the door and shut it on a dollar bill slowly pull it out of the door. If the gasket seals properly, you will feel tension as it grips the bill. Repeat this test all around the door. If the gasket doesn’t seal tightly, replace gasket after first checking the do

  • Randell 2010FMJB, MOTPMYSESUACELBISSOPERUDECORP NURT’NSEODTINU.TINUOTREWOPON.1.TINUNIGULP.1 LORTNOCERUTAREPMET.2 .FFODENRUT ERUTAREPMETKCEHC.2 .LORTNOC LORTNOCERUTAREPMET.3 .YTLUAF ERUTAREPMETTSET.3 .LORTNOC ROSSERPMOC.4 .DETAEHREVO .LIOCRESNEDNOCNAELC.4 .YTLUAFNAFRESNEDNOC.5NAFRESNEDNOCECIVRES.5 .ROTOM ROTCETORPDAOLREVO.6 .YTLUAF .DAOLREVOTSET.6 YALERROSSERPMOC.7 .YTLUAF .YALERTSET.7 .YTLUAFROSSERPMOC.8TAECIVRESROFLLAC.8 .0658-126-008-1 SELCYCTROHSTINU.YTRIDLIOCRESNEDNOC.1.LIOCNAELC.1 .YTLUAFNAFRESNEDNOC.2.ROTOMDNANAFECIVRES.2 .YTLUAFROSSERPMOC.3TAECIVRESROFLLAC.3 .0658-126-008-1 YLDETAEPERDAOLREVO.4 .GNIPPIRT .EGATLOVTELTUOKCEHC.4 YLTNATSNOCSNURTINU.PUDLIUBTSORF.1.ROTAROPAVETSORFED.1 GN

  • MOTPMYSESUACELBISSOPERUDECORP HGUONEDLOCTONTINULORTNOCERUTAREPMET.1 .HGIHOOTTES .GNITTESREWOL.1 LORTNOCERUTAREPMET.2 .YTLUAF .LORTNOCTSET.2 .YTRIDLIOCRESNEDNOC.3.LIOCNAELC.3 GNILAESTONROOD.4 .YLREPORP .ROODKCEHC.4 .DEGAMADTEKSAGROOD.5.TEKSAGROODECALPER.5 .YTLUAFNAFROTAROPAVE.6ROTAROPAVEECIVRES.6 .NAF .PUDECIROTAROPAVE.7.ROODKCEHC.7 ROGNIKAELTNAREGIRFER.8 .DETANI

Related Products and Documents (Freezer):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Juniper SRX240 Hardware manual juniper/srx240-M37.pdf 18 Jun 2022 178
2 IRiver AK240 Instruction book iriver/ak240-5N8.pdf 11 Aug 2022 52
3 Daewoo DSB-090L Service manual daewoo/dsb-090l-PV4.pdf 01 Feb 2023 62 1.27 Mb
4 Honda F506 Owner's manual honda/f506-16N.pdf 22 Jul 2023 251
5 JUKI DLN-6390 Instruction manual juki/dln-6390-61Y.pdf 30 Aug 2023 380
6 Extron electronics SI 3CT LP Manual  extron-electronics/si-3ct-lp-8XB.pdf 05 May 2023 6

Similar Resources:

  • LG

    LBC22520TT

    (36 pages)
    BOTTOM FREEZERREFRIGERATOROwner’s ManualPlease read this guide thoroughlybefore operating and keep it handy forreference at all times.Models / ModelosP/No. MFL61944107 LRBN2051#** LRBC2051#** LBC2252#**REFRIGERADORCON CONGELADORINFERIORManual de UsuarioLea detenidamente estas instrucciones antes deusar el refrigerador y guárdelas como referencia para el f …
  • Miele

    FN 3x402 i AU

    (84 pages)
    Operating and installation instructionsFreezerTo prevent the risk of accidents or damage to the appliance, it isessential to read these instructions before it is installed and used forthe first time.en – AU, NZ M.-Nr. 10 198 630 …
  • Cospolich

    F41-2M-SN-MLR

    (11 pages)
    Technical Manual Installation, Operation, and Maintenance Instructions Cospolich Refrigerator Company, Inc. Destrehan, LA 70047 800-423-7761 Modular Freezer F41-2M-SN-MLR www.Cospolich.com …
  • American Panel

    AP3BCF30-1

    (24 pages)
    REV. D Cooler is Better!TMUSER’S MANUAL BLAST CHILLER / SHOCK FREEZER MODEL AP3BCF30-1 American Panel Corporation 5800 S.E. 78th Street, Ocala, Florida 34472-3412 Phone: (352) 245-7055 Fax: (352) 245-0726E-mail: [email protected]
  • Master Bilt

    TAF-27

    (16 pages)
    TAF-27, TAF-48 & TAF-74 Solid Door Reach-In Freezers With Dixell Controller Installation & Operations Manual Master-Bilt Products 908 Highway 15 North New Albany, MS 38652 Phone: (800) 684-8988 …
  • True Fitness

    TDC-67

    (2 pages)
    Specifi cations subject to change without notice.Chart dimensions rounded up to the nearest 1/8" (millimeters rounded up to next whole number).ROUGH-IN DATA2001 East Terra Lane • P.O. Box 970 • O’Fallon, Missouri 63366(636)240-2400 • Fax (636)272-2408 • (800)325-6152 • Intl Fax# (001)636-272-7546Parts Dept. (800)424-TRUE • Parts Dept. Fax …

Comments, Questions and Opinions: