Sharp AN-LS1 Operation Manual
|
Sharp AN-LS1, 52 Specifications Main Body Description Ethernet to RS-232C Network Converter Input voltage DC 6.3 V, 400 mA Operating temperature 41°F to 104°F (5°C to 40°C) Storage temperature -4°F to 158°F (-20°C to 70°C) Dimensions (W x H x D) (approx.) 3 9 / 32 " x 1 5 / 32 " x 3 7 / 16 " (83 mm x 29 mm x 87 mm) Weight (approx.) 0.53 lbs (240 g) LEDS Power (Green), Link (Green), TX/RX (Orange) Terminal 10BASE-T Ethernet terminal for controller (Will operate on 100Base-TX) RJ-45 connector x 1 Conforms with IEEE802.3 standard Serial terminal for controller 9-pin D-sub male connector x 1 Conforms with RS-232C standard Serial terminal f
Sharp AN-LS1, 40 Password If units with user name/password set appear within the list display, the user name/password for those units must be entered. Enter when communicating with AN-LS1 When communicating with AN-LS1, when a dialog prompting input of user name/password is displayed as shown below, enter the user name and password set at the unit side, enter a check mark in the “Save this password” box, as required, and click “OK”. Inputting in advance It is possible to enter the user name/password in advance. 1 Click the subject unit.
22 Busy Reply Setting (ADVANCED[3]Busy Reply) The input terminals of AN-LS1 can be RS-232C (CONTROLLER) and 10BASE-T. Respective input terminals can be connected to separate devices, but in actual if one of the terminals is being used the other terminal cannot be used. When data is being transmitted using one input terminal, it is not possible to use the other inpu
Sharp AN-LS1, 35 Using the Software Add (Manual) Adding units to the list display manually in cases such as when units cannot be found, even by searching. 1 Click “Add”. | “Add Unit” dialog will be displayed.
Sharp AN-LS1, 7 Connections Overview Use the following procedure for connection of AN-LS1. 1 Connect AN-LS1 to an Ethernet LAN. (Page 8) 2 Connect devices to AN-LS1. (Page 9) • Connect a commercially available controller or computer. • Connect a projector. 3 Connect the AC adaptor. (Page 10) Ethernet LAN 12 32 Computer or Controller Projector
Sharp AN-LS1, 44 Changing / Removing the Software Be sure to always uninstall the Sharp COM Redirection Software, when reinstalling the Sharp COM Redirection Software or an updated version. 1 Quit all running applications. 2 Click the “Start” menu, “Settings”, and then “Control Panel”. (If your operating system is Windows XP, click the “Start” button, and then “Control Panel”.) 3 Click the “Add or Remove Programs” icon. 4 Select “Sharp COM Redirection Software”, and then click “Change/Remove”.
Sharp AN-LS1, 50 \ Check if the “TCP/IP” protocol is operating correctly using the “PING” command. Also, check if an IP address is set. 1. Open a command prompt (MS-DOS Prompt). •In the case of Windows 98 or 98SE: click “START” → “Programs” → “MS-DOS Prompt” in order. •In the case of Windows Me: click “START” → “Programs” → “Accessories” → “MS-DOS Prompt” in order. •In the case of Windows 2000: click “START” → “Programs” → “Accessories” → “Command Prompt” in order. •In case of Windows XP: click “START” → “Programs” → “Accessories” → “Command Prompt”
Sharp AN-LS1, 37 Using the Software Refresh Changing the list display content to the latest state. 1 Click “Refresh”. | Model Name, Unit Name and Status will be updated to the latest information. About Status Ready : Communication with AN-LS1 is possible. No Response : Communication with AN-LS1 is not possible. Please check connection. (Page 47) Busy : Already connected from another computer. • “Busy” may sometimes be displayed even when a network connection has been disconnected with a normal procedure. (For more details, please refer to page 51.)
51 Appendix Sharp COM Redirection Software does not operate. AN-LS1 cannot be found by a search. \ Check the connection. (Refer to “When connecting AN-LS1 to a computer using network (LAN)- connection” in Troubleshooting page 47.) \ Check the network settings. (Refer to “Check the network settings for the computer and AN-LS1” in the Troubleshooting page 48.) \ In the
Sharp AN-LS1, 13 Setup SETUP MENU Description SETUP MENU (Main Menu) S E T U P M E N U [1]IP Address [2]Subnet Mask [3]Default Gateway [4]User Name [5]Password [6]RS-232C Baud Rate [7]Unit Name [A]Advanced Setup [D]Disconnect All [V]View All Setting [S]Save & Quit [Q]Quit Unchanged setup> [1] IP Address (Factory default setting : 192.168.150.2) IP address settings. (Page 18) [2] Subnet Mask (Factory default setting : 255.255.255.0) Subnet mask settings. (Page 18) [3] Default Gateway (Factory default setting : Not Used) Default gateway settings. (Page 18) [4] User Name (Factory default settin
30 Explanation of the Screen ▼ Configuration dialog 8 9 2 1 4 5 6 7 3 1 List display area List display of states of all units recognizing Sharp COM Redirection Software, and allocation states of Virtual COM ports. (Page 32) 2 Search Searches for units, and adds to the list display. (Page 31) 3 Setting Setting of computer data communication port number and search port
Sharp AN-LS1, 21 Setup The followings are descriptions of the ADVANCED SETUP MENU. Setting Automatic Logout Time (ADVANCED[1]Auto Logout Time) If there is no input after a fixed time, AN-LS1 automatically disconnects network connection using the Auto Logout function. It is possible to set the time until AN-LS1 is automatically disconnected in units of a minute (from 1 to 65535 minutes). advanced>1 Valid range : 0 to 65535 (minute) note: if you enter “0”, auto logout function will be disable. Auto Logout Time : 5 Pleas
Sharp AN-LS1, 28 6 Enter a check mark against Virtual COMs to be added to the computer and click “OK”. • It is necessary to add the same number of Virtual COMs as the number of these units used. • If “Cancel” is clicked, the Sharp COM Redirection Software Driver is not installed. If you want to install later, run Sharp COM Redirection Software using “Add or Remove Programs”. When the “Hardware Installation” dialog box is displayed, click “Continue Anyway”. This dialog box may appear a couple of times. 7 When the installation procedure is successfu
Sharp AN-LS1, 53 Appendix Index 10BASE-T Ethernet terminal ............................. 8 A Accept All IP Addr............................................ 23 Accept IP Addr ................................................ 23 Add .................................................................. 35 Add Unit dialog ................................................ 35 Advanced Setup .............................................. 20 ADVANCED SETUP MENU ............................ 14 Auto Logout Time ............................................ 21 B Busy Reply ...................................................... 22 C COM Redirect Port ......................................
Sharp AN-LS1, 8 Connecting to an Ethernet LAN Connect AN-LS1 to a hub or a computer using a Category 5 cable. • It is necessary to perform computer setting according to the network environment in advance. • Default IP address and subnet mask of AN-LS1 are as follows: IP address : 192.168.150.2 Subnet mask : 255.255.255.0 • When using AN-LS1 by connecting to an existing Ethernet LAN, and if there is any problem with the above settings, change settings such as IP address by creating an independent network without connecting to the existing Ethernet LAN or by connecting a computer to the RS-232C (CONTROLLER) terminal. After that, connect to the existing Ethernet LAN. Category 5 ca
Sharp AN-LS1, 23 Setup Carrying out Network Ping Test (ADVANCED[5]Network Ping Test) It is possible to confirm that a network connection between AN-LS1 and a computer etc. is working normally. advanced>5 Ping dest IP addr :192.168.150.1 Please Enter :192.168.150.152 (change) —> 192.168.150.152 32 bytes from 192.168.150.152: icmp_seq = 1, time = 0 ms 32 bytes from 192.168.150.152: icmp_seq = 2, time = 0 ms 32 bytes from 192.168.150.152: icmp_seq = 3, time = 0 ms 32 bytes from 192.168.150.152: icmp_seq = 4, time = 0 ms • If the return key is pressed wi
Introduction Connections Setup Using the Software Appendix MODEL AN-LS1 OPERATION MANUAL Ethernet to RS-232C Network Converter • Please read this operation manual carefully to ensure correct use of the Ethernet to RS- 232C Network Converter. • Please read this operation manual together with the “IMPORTANT INFORMATION” leaflet. • Prior to installation of this product, carry ou
Sharp AN-LS1, 17 Setup Quit Save settings and quit. ([S]Save & Quit) Save set values and quit menu. ▼ The SETUP MENU ———————— S E T U P M E N U —————————— [1]IP Address [2]Subnet Mask [3]Default Gateway [4]User Name [5]Password [6]RS-232C Baud Rate [7]Unit Name [A]Advanced Setup [D]Disconnect All [V]View All Setting [S]Save & Quit [Q]Quit Unchanged setup>s All Connection will be disconnect. Continue(y/n)? y Apply New setting...Done. Quit without saving settings
Sharp AN-LS1, 49 Appendix C:\>ipconfig “RETURN” Usage examples of ipconfig C:\>ipconfig /? displays how to use “ipconfig.exe”. C:\>ipconfig displays the set IP address, subnet mask and default gateway. C:\>ipconfig /all displays all the setting information related to TCP/IP. 3. To return to the Windows screen, enter “exit” and press the “RETURN” key.
Sharp AN-LS1, 4 Part Names and Functions Main Body TX/RX LED indicator (Page 5) Lit when transmitting data. 10BASE-T Ethernet terminal (Page 8) To connect to an Ethernet LAN. LINK LED indicator (Page 5) Lit when link is active. RS-232C terminal for controller (Page 9) To connect a commercially available controller or computer. AN-LS1 POWER RS-232C(CONTROLLER) RS-232C(PROJECTOR) INIT. DC IN TX/RX 10BASE-T LINK POWER LED indicator (Page 5) Lit when the power supply is on. Wall mount screw holes (Page 6) To be used for mounting AN-LS1 on a wall. DC power input (Page 10) To connect an AC adaptor. Initialize (INIT.) button (Page 51) To initialize the settings for AN-LS1 to the f
DOWNLOAD |
Sena LTC100 Network Accessory Operation & user’s manual
LTC100 |
Sharp CD-BP2000W Network Accessory Service manual
CD-BP2000W |
SignaMax FO-065-1195 Network Accessory Operation & user’s manual
FO-065-1195 |
NAIM NDX - Network Accessory Operation & user’s manual
NDX - |
D-Link 1000BASE-SX Network Accessory Manual
1000BASE-SX |
Sharp TU-DTV1000/A Network Accessory Service manual
TU-DTV1000/A |
Tibbo DW-DS1101 Network Accessory Operation & user’s manual
DW-DS1101 |
Bose WAVE SOUNDLINK ADAPTER Network Accessory Quick start manual
WAVE SOUNDLINK ADAPTER |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Suzuki | MDG-330 | Owner's manual | suzuki/mdg-330-5UG.pdf | 12 Apr 2023 | 34 | |
2 | Furuno | 1824C | Installation manual | furuno/1824c-V8Y.pdf | 04 Jan 2024 | 91 | 4.2 Mb |
3 | Amcor | AM-12 | Owner's manual | amcor/am-12-B3J.pdf | 16 Jan 2024 | 16 | |
4 | Bissell | Spotbot 1200 series | Operation & user’s manual | bissell/spotbot-1200-series-35N.pdf | 22 Feb 2024 | 32 | 1.87 Mb |
5 | Konica Minolta | Di 200 | Operation & user’s manual | konica-minolta/di-200-475.pdf | 20 Oct 2023 | 138 | |
6 | Abbott | AMPLATZER TorqVue LP | Instructions for use | abbott/amplatzer-torqvue-lp-D8N.pdf | 10 Nov 2023 | 5 |
TSAT AS
Product: DOC3010, Revision: 1.6.3 January 2013 Telemetry and data transfer via SATellite TSAT 3000 Command Line Interpreter Command Reference Manual 1.6.3
…
TSAT 3000(41 pages) |
Agilent Technologies
Agilent E5071C ENA Network AnalyzersService GuideEighth EditionManufacturing No. E5071-90140April 2012Advanced Test Equipment Rentalswww.atecorp.com 800-404-ATEC (2832)®Established 1981
…
E5071C ENA(312 pages) |
Rittal
Bürsten-Kit für Kabelkanal VX ITBrush kit for cable duct VX ITKit de brosses pour goulotte de câblage VX ITMontageanleitungAssembly instructionsNotice de montageVX 5302.036
…
VX 5302.036(12 pages) |
NEC
SV8100/SV9100 & INMAIL ADMINISTRATION GUIDE F o r S e r v i c e C a l l : ( 8 0 0 ) 5 9 5 - 8 8 8 2 / E m a i l : d i s p a t c h @ o k t e l e p h o n e . c o m Page 1 Phone System Programming Phone Button Outline: Exit - Exit’s out of various programming Security - Locks the phone for security purposes …
Univerge SV9100(3 pages) |
Valcom
1 947987 ISSUE 5 VIP-802 DUAL ENHANCED NETWORK AUDIO PORT INTRODUCTION The VIP-802 Dual Enhanced Network Audio Port enables voice access to two zones of one-way paging over an IP network, allowing page zones to be extended anywhere network connectivity is available. The VIP-802 can be programmed as a SIP (Session Initiation Protocol) device with two …
VIP-802(5 pages) |
National Instruments
FieldPoint™ FP-1000/1001 User ManualFieldPoint FP-1000/1001 User ManualAugust 1998 EditionPart Number 321631B-01© Copyright 1997, 1998 National Instruments Corporation. All rights reserved.
…
FP-1000(74 pages) |
Marantz Amplifier PM7005#237XOA: PM7005 Amplifier Quick start manual PM7005, 13 |
activecare medical Wheelchair Wildcat#3RC9DV Wildcat: activecare medical Wheelchair Owner Documentation Wildcat, 20 |
Asko Dishwasher D5954Dishwasher PDF Operating instructions manual D5954, 36 |
Nordpeis Indoor Fireplace NI-22Nordpeis Product Manual: NI-22 PDF Operation & user’s manual - IFL17J NI-22, 50 |
Mitel IP Phone SIP USER AND ADMINISTRATOR GUIDE 5340IP Phone Installation manual (Mitel SIP USER AND ADMINISTRATOR GUIDE 5340) SIP USER AND ADMINISTRATOR GUIDE 5340, 12 |
HP Laptop G72HP G72 User Manual (Maintenance and service manual), @9U7VGM G72, 135 |
Jinmuyu Electronics Card Reader JMY6801H ICJinmuyu Electronics Product Manual: JMY6801H IC PDF Operation & user’s manual - 182K8L JMY6801H IC, 6 |
Wintal Set-top boxes STB10SDSTB10SD (Set-top boxes ePDF User Manual, #9IS12L) STB10SD, 9 |
Philips Speakers SBCBA300PDF User Guide (@38EB19), Philips SBCBA300 Speakers (Tue 02.2024) SBCBA300, 2 |
Philips TV 21PT5402Philips Product User Manual: 21PT5402 PDF Specifications - 6HA22L 21PT5402, 3 |
Active Care Medical Wheelchair IntrepidPDF User Manual (@I884G9), Active Care Medical Intrepid Wheelchair (14.02.2024) Intrepid, 24 |
Samsung TV LN40D610M4FSamsung LN40D610M4F TV Operation & user’s manual LN40D610M4F, 4 |