Manualios.com

GE WF180 Operation & User’s Manual

GE WF180 Manual Online:

3.4, 1785 votes
GE WF180 User Manual
GE WF180 User Guide
GE WF180 Online Manual

Text of GE WF180 User Guide:

  • GE WF180, a WF180 e Through the Wall Exhaust Fan User’s Guide 210575001 Rev. A 1-08 Item Stock Number(s): WF180 READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE. GENERAL SAFETY INFORMATION When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock and injury to person, including the following: 1. Read all instructions before instal

  • GE WF180, 210575001 Rev. A 1-08 GENERAL SAFETY INFORMATION (Continued) fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local code authorities. CAUTION: FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS. 6. When cutting or drilling into wa

  • 210575001 Rev. A 1-08 CAUTION: ONLY CUT THE EXTERIOR WALL SIDING. DO NOT CUT INTO THE SHEATHING (PLYWOOD) UNDERNEATH. 6. Once the siding is cut, nail down all the loose ends of the siding (Figure 4). 7. In the center of the 14-1/2" square cut in step 5, mark and cut a 8-1/4" diameter hole through the wall sheathing (Figure 5). 8. Install 1" x 2" casing strips (not incl

  • GE WF180, 210575001 Rev. A 1-08 3. Pull the electrical wires through the electrical opening of the interior housing. Remove one of the electrical knockouts of the wiring compartment and run wires through the opening making sure to leave enough wiring to make the connection to the fan’s receptacle. Secure wires to wiring compartment with an approved electrical connector (Figure 9). 4. Connect the green or bare ground wire from the house to the ground screw in the wire compartment. Connect the white wire from the house to the white wire from the receptacle. Connect the hot (black) wire from the wall switch to the black wire from the recepta

  • GE WF180, 210575001 Rev. A 1-08 5 of 8 www.geelectrical.com Troubleshooting Guide Trouble Probable Cause Suggested Remedy 1. Fan does not operate when the switch is on. 1a. A fuse may be blown or a circuit tripped. 1a. Replace fuse or reset circuit breaker. 1b. Connector plug from motor is not plugged in. 1b. Turn off power to unit. Remove Grill and plug motor into receptacle in housing. Restore power to unit. 1c. Wiring is not connected properly. 1c. Turn off power to unit. Check that all wires are connected. 1d. Motor has stopped operating. 1d. Replace motor. 2. Fan is operating, but air moves slower than normal. 2. Obstruction in the outer housing. 2

  • WARRANTY WHAT IS COVERED? Full Five Year Parts Warranty from date of original proof of purchase. We will provide, free of charge, a replacement part that fails due to manufacturing defect in material or workmanship, when installed and used as directed in the User’s Guide. This warranty is extended to the original purchaser for products purchased for ordinary home use. GE Bath Fan Hot Line 1-800-

  • GE WF180, 210575001 Rev. A 1-08 7 of 8 www.geelectrical.com REPLACEMENT PARTS DIAGRAM 1 11 2 3 4 5 6 7 8 9 12 13 14 16 15 17 18 19 20 21 22 23 10 5 3 20 # Qty. Description Replacement Part # 1 1 Interior Housing 5S2203001 2 1 Exterior Housing 5S2203002 3 2 Bushing 5S2203003 4 1 Rod 5S2203004 5 2 Gasket 5S2203005 6 1 Spring 5S2203006 7 1 Damper 5S2203007 8 1 Gasket 5S2203008 9 1 Gasket 5S2203009 10 1 Wire Compartment 5S2203010 11 1 Ground Screw 5S2203011 # Qty. Description Replacement Part # 12 1 Wire Compartment Cover 5S2203012 13 1 Polarized Recep

Related Products and Documents (Fan):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Chevrolet 2006 Equinox Owner's manual chevrolet/2006-equinox-AV6.pdf 23 Feb 2023 378 2.53 Mb
2 HP 3820 - Deskjet Color Inkjet Printer Operation & user’s manual hp/3820-deskjet-color-inkjet-printer-Z97.pdf 06 Jan 2024 103 0.75 Mb
3 Philips 170s6 Operation & user’s manual philips/170s6-Y6E.pdf 17 Jan 2024 98 1.36 Mb
4 Toshiba 1135-S155 Specifications toshiba/1135-s155-CAW.pdf 09 Mar 2024 8 0.29 Mb
5 Eureka 970-975 Series Owner's manual eureka/970-975-series-74O.pdf 28 Jun 2023 12 0.23 Mb
6 Homelite HLCA80710 Operator's manual homelite/hlca80710-6A9.pdf 26 Feb 2024 52 5.57 Mb

Similar Resources:

  • Tuma

    BVN10A001

    (2 pages)
    DIMENSIONSUnit:mmventilation fan / Wall Exhaust FanModelBVN10A001Voltage(V)100-240Frequency(Hz)50-60Air Flow(m3/h)100Power Consumption(W)1.7Weight(g)630Accessories : Screw (Ø4x27mm)-4 pcs White plastic wall plugs (Ø7.5x25mm)-4 pcs9070Ø99Installation and Operating Instructions SUNONWEALTH ELECTRIC MACHINE INDUSTRY CO.,LTD.MODEL BVN10A001200200 …
  • ebm-papst

    A8D800-AD01-01

    (12 pages)
    Operating instructionsA8D800-AD01-01Translation of the original operating instructionsebm-papst Mulfingen GmbH & Co. KGBachmühle 2D-74673 MulfingenPhone +49 (0) 7938 81-0Fax +49 (0) 7938 [email protected]. SAFETY REGULATIONS AND NOTES11. SAFETY REGULATIONS AND NOTESPlease read these operating instructions carefully bef …
  • ebm-papst

    A3G500-AN33-03

    (12 pages)
    Operating instructionsA3G500-AN33-03Translation of the original operating instructionsebm-papst Mulfingen GmbH & Co. KGBachmühle 2D-74673 MulfingenPhone +49 (0) 7938 81-0Fax +49 (0) 7938 [email protected]. SAFETY REGULATIONS AND NOTES11. SAFETY REGULATIONS AND NOTESPlease read these operating instructions carefully bef …
  • Abicor Binzel

    xFUME VAC ADVANCED

    (100 pages)
    T E C H N O L O G Y F O R T H E W E L D E R ´ S W O R L D .www.binzel-abicor.com DE Betriebsanleitung / ENOperating instructionsFR Mode d'emploi / ES Instructivo de servicioxFUME VAC ADVANCEDDE Hochvakuum AbsaugsystemEN High-vacuum extraction systemFR Dispositif d’aspiration vide élevéES Extractor de humos alto vacío …
  • Lasko

    4420

    (6 pages)
    MANTENIMIENTOPara reducir el riesgo de choque eléctrico e incendio, por favor obedezca las siguientes instrucciones.- Siempre desconecte el cable eléctrico antes de trasladar, reparar o limpiar.- NUNCA coloque el Ventilador dentro de o cerca de agua.- Limpie el Ventilador únicamente con una aspiradora equipada con un accesorio de cepillo; la aspiradora …
  • Koenic

    KSF 400-M

    (74 pages)
    Size - A5Stand FanKSF 400-MDEGebrauchsanweisungΟδηγίες χρήσηςENUser manualManual de instruccionesMode d'emploiHasználati leírásManuale dell'utenteGebruiksaanwijzingInstrukcja obsługiManual de utilizaçãoAnvändarhandbokKullanım KılavuzuDeutsch 1 - 6Ελληνικά 7 - 12English 13 - 18Español 19 - 24Français 25 - 30Magyar 31 …