Siemens LC 89950 GB Operating And Installation Instructions
|
Siemens LC 89950 GB, 3 Appliance description Operating modes Exhaust-air mode: ❑ The extractor-hood fan extracts the kitchen vapours and conveys them through the grease filter into the atmosphere. ❑ The grease filter absorbs the solid particles in the kitchen vapours. ❑ The kitchen is kept almost free of grease and odours. D When the extractor hood is operated in exhaust-air mode simultaneously with a different burner which also makes use of the same chimney (such as gas, oil or coal-fired heaters, continuous-flow heaters, hot-water boilers) care must be take
Siemens LC 89950 GB, 4 Before using for the first time Important notes: ❑ The Instructions for Use apply to several versions of this appliance. Accordingly, you may find descriptions of individual features that do not apply to your specific appliance. ❑ This extractor hood complies with all relevant safety regulations. Repairs should be carried out by qualified technicians only. Improper repairs may put the user at considerable risk. ❑ Before using your appliance for the first time, please read these Instructions for Use
Siemens LC 89950 GB, 5 Switching the fan OFF: ❑ Keep pressing the Ü – button until the fan switches off. The displayed { goes out shortly afterwards. Intensive setting: Maximum power is obtained at the intensive setting. It is only required for short intervals. ❑ Keep pressing the Ü + button until a ç appears in the display. ❑ If the intensive setting is not cancelled by hand, the fan will automatically switch back to step } after 10 minutes. Lighting: ❑ Briefly press the 0 +/0 – button to switch the light on and off. ❑ The light can be switched on at any time, even though the fan is switched off. ❑ Adjusting the brightness: Hold down the 0 + or 0 – button until the desired
Siemens LC 89950 GB, 6 Grease filters: Metal filters are used to trap the greasy element of the vapours that develop during cooking. The filter mats are made from non- combustible metal. Caution: As the filter becomes more and more saturated with grease, not only does the risk of it catching fire increase but the efficiency of the extractor hood can also be adversely affected. Important: By cleaning the metal grease filters at appropriate intervals, the possibility of them catching fire as a result of a build-up
Siemens LC 89950 GB, 7 Activated carbon filter: For neutralizing odours in recirculating mode. Saturation indicator: ã When the activated carbon filter reaches saturation point, an acoustic signal is sounded for 10 seconds after the fan has switched off, and a ã appears in the display. The activated carbon filter should be replaced straight away. Removing the filter: Warning: The halogen bulbs must be switched off and cool. 1. Remove the metal filters. 2. Press in the lug at the front and remove the activated carbon filter. Filters and maintenance 3. Engage t
Siemens LC 89950 GB, 8 Cleaning and care Disconnect the extractor hood from the electricity supply by pulling out the mains plug or switching it off at the fuse box. ❑ At the same time as you clean the grease filters, clean off any grease from all accessible parts of the housing. This significantly reduces the fire hazard and ensures that the extractor hood performs as effectively as possible. ❑ Use a hot detergent solution or a mild window cleaner to clean the canopy of the extractor hood. ❑ Do not scrape off any dirt that has dried on but loosen it up with a damp cloth. ❑ Do not use abrasive cleaning agents or spo
Siemens LC 89950 GB, 9 If you encounter a problem If an # or ã appears in the display: ❑ See "Filters and maintenance" Section. If is not possible to operate the extractor hood: ❑ Disconnect the extractor hood from the mains electricity supply by pulling out the plug or switching it off at the main fuse box. Wait for approx. 1 minute and then switch it on again. If you have any questions or if a fault occurs, please call Customer Service. (See list of Customer Service representatives). When you call, please quote the following: Setting the saturation indicat
Siemens LC 89950 GB, 10 Important information Installation Instructions: Additional information concerning gas cookers: When installing gas hotplates, comply with the relevant national statutory regulations (e.g. in Germany: Technische Regeln Gasinstallation TRGI). Always comply with the currently valid regulations and installation instructions supplied by the gas appliance manufacturer. Only one side of the extractor hood may be installed next to a high-sided unit or high wall. Gap at least 50 mm. Minimum distance on gas hotplates between the upper edge of the trivet and lower edge of the extractor hood: 650 mm, Fig. 1. Old appliances are no
Siemens LC 89950 GB, 11 Prior to installation Exhaust-air mode The exhaust air is discharged upwards through a ventilation shaft or directly through the outside wall into the open. D Exhaust air should neither be directed into a smoke or exhaust flue that is currently used for other purposes, nor into a shaft that is used for ventilating rooms in which stoves or fireplaces are also located. Exhaust air may be discharged in accordance with official and statutory regulations only (e.g. national building regulations). Local authority regulations must be observed when discharging air into smoke or exhaust flues that are not otherwise in use. D When the extractor hood is operated in
Siemens LC 89950 GB, 12 Prior to installation For optimum extractor hood efficiency: ❑ Short, smooth air exhaust pipe. ❑ As few bends in the pipe as possible. ❑ Diameter of pipe to be as large as possible and no tight bends in pipe. If long, rough exhaust-air pipes, many pipe bends or smaller pipe diameters are used, the air extraction rate will no longer be at an optimum level and there will be an increase in noise. ❑ Round pipes: We recommend Internal diameter: 150 mm (at least 120 mm). ❑ Flat ducts must have an internal cross- section that equates to that of round pipes. There should be no sharp bends. l 120 mm approx. 113 cm 2 l 150 mm approx.
13 Electrical connection WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: Fitting a Different Plug: The wires in the mains lead are coloured in accordance with the following code: Green and Yellow – Earth Blue – Neutral Brown – Live If you fit your own plug, the colours of these wires may not correspond with the identifying marks on the plug terminals. This is
14 Installation This extractor hood is intended to be mounted onto the kitchen wall. 1. Remove the grease filter (refer to Operating Instructions). 2. Draw a line on the wall from the ceiling to the lower edge of the hood at the centre of the location where the hood is going to be mounted. 3. Use the template to mark the points on the wall where the screws will be mounted
Siemens LC 89950 GB, 15 Installation 13. Insert the complete flue duct at an angle into the glass shield and swivel backwards. Warning: The holes in the flue duct must be positioned exactly over the switches. 07. Screw in lower screws (hex screws). If any pressure is exerted on the glass screen when tightening the screws it could lead to glass breakage. 08. Stick protective film over the holes of the 2 lower mounting bolts in the protective grid. 09. Connect up the air outlet pipe. 10. Connect the hood to the electricity supply. 11. Remove the protective film from the two flue ducts. Take ca
Siemens LC479650UC Ventilation Hood Use and care manual
LC479650UC |
Siemens LI60OA520 Ventilation Hood Instruction manual
LI60OA520 |
Siemens IQ 100 Ventilation Hood Manual
IQ 100 |
Siemens LC 46254 Ventilation Hood Operating and installation instructions
LC 46254 |
Siemens LC56KA670 Ventilation Hood Instruction manual
LC56KA670 |
Siemens VIVA Ventilation Hood Instruction manual
VIVA |
Siemens VIVA Ventilation Hood Instruction manual
VIVA |
Siemens LB59584 Ventilation Hood Instruction manual
LB59584 |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Speco | SP-5IO2 | Datasheet | speco/sp-5io2-QN8.pdf | 28 Apr 2023 | 1 | 0.85 Mb |
2 | Kohler | rada outlook | Product manual | kohler/rada-outlook-U93.pdf | 06 Nov 2022 | 32 | |
3 | LaCie | Bigger Disk Extreme | Operation & user’s manual | lacie/bigger-disk-extreme-4WL.pdf | 22 Nov 2023 | 59 | |
4 | LG | DLEX2550 | Owner's manual | lg/dlex2550-C71.pdf | 20 May 2023 | 200 | |
5 | TOHATSU | MD 40B2 | Owner's manual | tohatsu/md-40b2-19G.pdf | 13 Sep 2023 | 101 | |
6 | Philips | AEA1000/37 | Operation & user’s manual | philips/aea1000-37-M9I.pdf | 03 Sep 2023 | 16 | 2.73 Mb |
Best
- 1 -Model P195ENGLISH......................................3FRANÇAIS.................................11ESPAÑOL...................................19In USA - BEST Hartford, WisconsinIn CANADA - BEST Drummondville, QC, CanadaREGISTER YOUR PRODUCT ONLINE AT : www.BestRangeHoods.com/registerFor additional Information visit www.BestRangeHoods.com
…
P195(36 pages) |
THERMEx
Brukervejledning Bruksanvisning Käyttöohje Instrucciones de uso Instruction manualDANSK NORSK SVENSKA SUOMI ESPAÑOL ENGLISHSUPER SILENT UDTRÆK BETJENINGSVEJLEDNING
…
Super Silent Udtraek(40 pages) |
Candy
Model: CGM91XCAPPA ASPIRANTE - Istruzioni per l'usoDUNSTABZUGSHAUBE - GebrauchsanweisungCAMPANA EXTRACTORA - Manual de utilizaciónHOTTE DE CUISINE - Notice d'utilisationCOOKER HOOD - User instructionsAFZUIGKAP - GebruiksaanwijzingCOIFA ASPIRANTE - Manual do usuárioIDEFGBNLPODSAVAČ PAR – uživatelská příručkaEMHÆTTE - BrugervejledningLIESI …
CGM 91(48 pages) |
Faber
INSD29SSV INSD35SSV INCA SDInstallation InstructionsUse and Care InformationInstructions d'installationUtilisez et d'entretienInstrucciones de instalaciónInformación de uso y cuidado
…
INCA SD Series(56 pages) |
Zanussi
ZANUSSIP R O F E S S I O N A L304 AISI WALL TYPE HOODSVAPOR - V line - 1600mm304 S/S LABYRINTH FILTER H=350 MM 2 3 4 5 5 6 7 8304 S/S BLIND PANEL 400X350H MM 1 1 1 1 2 2 2 2INCLUDED ACCESSORIESNet weight - kg. 63 69 82 94 106 118 130 143Air Capacity - mc/h 2200 2900 3600 4300 5000 5700 6400 7100 height 400 400 400 400 400 400 400 400 depth 1600 1600 16 …
Vapor 640033(2 pages) |
SystemAir
126028/991.0358.133 01.09..2015 RD/KMB 251-10/B Montasje, bruks- og vedlikeholdsanvisning Installation, user and maintenance instructions
…
Villavent 251-10/B(12 pages) |
Lionel Toy Three Rivers Fast FreightPDF User Manual (@IJV84S), Lionel Three Rivers Fast Freight Toy (15th Dec 2023) Three Rivers Fast Freight, 24 |
Valgrind Software SoftwareSoftware Quick start manual - B4I133 Software, 319 |
Pioneer Antenna AN-70DAB#FM5O35 AN-70DAB: Pioneer Antenna Owner Documentation AN-70DAB, 4 |
Landice Treadmill L7 ClubLandice L7 Club User Guide (Service manual), @JN599O L7 Club, 120 |
Black Max Trimmer BM25TEC#18NYF5 BM25TEC: Black Max Trimmer Owner Documentation BM25TEC, 36 |
Pioneer Receiver VSX-329-KService manual for Pioneer VSX-329-K Receiver VSX-329-K, 6 |
AudioCodes Gateway MediaPack MP-124Operation & user’s manual for AudioCodes MediaPack MP-124 Gateway MediaPack MP-124, 164 |
Canon Office Equipment imagePROGRAF iPF6350Canon Office Equipment imagePROGRAF iPF6350 Basic manual imagePROGRAF iPF6350, 52 |
Quantum Storage Scalar 50Storage Instructions manual (Quantum Scalar 50) Scalar 50, 6 |
Microframe Corporation Transmitter 3500 seriesMicroframe Corporation 3500 series Guide (Operating manual), @KOB625 3500 series, 21 |
Fisher & Paykel Kitchen Appliances OR60Fisher & Paykel Kitchen Appliances OR60 Installation instructions and user manual OR60, 56 |
Best Power UPS FortressBest Power Fortress Guide (Doc Type: UPS Operation & user’s manual) Fortress, 80 |