Text of GE D20MX User Guide:

  • CHAPTER 3: CONNECTING TO DEVICES AND NETWORKS D20MX HARDWARE USER’S MANUAL GE INFORMATION 51 Figure 21: RS-232 Switch panel A pair of LEDs marked CCU A and CCU B indicate which of the D20 units is currently active. If the hardware or software of the active unit fails, it is automatically switched offline and serial connections to the field are transferred to the standby unit. A toggle sw

  • GE D20MX, APPENDIX D: USING CONFIGPRO WITH D20MX D20MX HARDWARE USER’S MANUAL GE INFORMATION 121 2.3.4. Confirm that access is allowed by pressing the Enter key a couple of times. 2.4. Download [sync] the configuration from ConfigPro to the D20MX by pressing the F7 key on the key board. 2.5. Optionally you can set up the terminal emulator for faster download speed: 2.5.1. Login to the D20MX device through the ConfigPro Terminal Emulator. Result: The D20M prompt appears. 2.5.2. Type baud 115200 and press Enter. Result: The D20MX baud rate changes from 19200 to 115200. 2.5.3. Disconnect the D20MX from ConfigPro by selecting Communications > Di

  • GE D20MX, APPENDIX D: USING CONFIGPRO WITH D20MX D20MX HARDWARE USER’S MANUAL GE INFORMATION 133 3. Click Next. Result: The ConfigPro Application Installer - Select Source Directory window appears. 4. Select a Source director [this is the DEFNs/ APPLDEF path within the D20MX Documentation CD]. 5. Select the DAL100.DB file and click Select. The Definitions Found field should indicate Yes.

  • 126 GE INFORMATION D20MX HARDWARE USER’S MANUAL APPENDIX D: USING CONFIGPRO WITH D20MX 4. Login to WinSCP using the D20MX IP address and port number 22. NOTE In the D20MX configuration, port 22 has been created in the Services section of the Device LAN Properties. 5. If the following window appears, click Yes. 6. Make a copy of the generated configuration file D20MXDE

  • GE D20MX, 76 GE INFORMATION D20MX HARDWARE USER’S MANUAL CHAPTER 5: CONFIGURING THE SOFTWARE 18.4. Update the new tables: Remote RADIUS Servers Table, Remote Syslog Servers Table, TLS Auth Info Table, TLS CA Info Table, First PEM File Table, Second PEM File Table and Login Warning Banner Table, referring to the B014-1NCG WESMAINT II+ configuration guide. 19. Generate the iSCS Configuration for the Project: 19.1. Click the Project tab of the original D20 device configuration. 19.2. Click: the D20 device. 19.3. Click the ribbon Co

  • GE D20MX, CHAPTER 1: BEFORE YOU START D20MX HARDWARE USER’S MANUAL GE INFORMATION 15 Regulatory compliance information CE Mark compliance The D20MX is rated as CISPR 11 Group 1 Class “A” equipment. To meet essential safety requirements of the LV Directive 2006/95/EC, the D20 chassis must be installed in a secondary cabinet if an operating voltage on any of the terminals is equal to or higher than 50 VAC or 75 VDC. Proper wiring practices and applicable local safety standards defining protection against electri

  • GE D20MX, D20MX HARDWARE USER’S MANUAL GE INFORMATION 31 D20MX Processor Chapter 2: Installing the D20MX Installing the D20MX This chapter covers the following topics: • D20 chassis layouts • Overview of the steps and tools required to install the D20MX • Retrofitting the D20MX in an existing D20 • Grounding the D20MX and connecting the power supply D20 chassis layouts Installation of the D20MX can be performed with one of three D20 chassis layouts; see “Installation steps” on page 33. The D20 non-VME chassis front panel layouts for the D20MX upgrade kits comprise: • A D20 containing a D20MX with front Ethernet connectors; see Figure 6. • A D20 cont

  • GE D20MX, APPENDIX D: USING CONFIGPRO WITH D20MX D20MX HARDWARE USER’S MANUAL GE INFORMATION 127 9. Login to the D20M prompt of the D20MX RTU - this is the SHELL [option 3] menu. 10. Suspend the processor by typing sp and pressing Enter. 11. Copy the configuration by typing cc and pressing Enter. 12. Select the configuration file by tying sc and pressing Enter. 13. Restart the D20MX device by typing boot and pressing Enter.

  • GE D20MX, APPENDIX D: USING CONFIGPRO WITH D20MX D20MX HARDWARE USER’S MANUAL GE INFORMATION 113 5.3. Configure the new Wesmaint II [B014-1N V620] application referring to its configuration guide. There are new tables and security settings that are required to be configured. For complete details, refer to the D20MX Documentation CD for the B014-1N configuration guide. 5.3.1. Use the D20MX factory default configuration as a reference. 5.3.2. Double-click on this factory default configuration and click the System Point Database Applications tab. 5.3.3. Double-click on the Wesmaint II+ application. 5.3.4. Import the RADIUS roles from the D20MX default configuration into the D20MX device

  • GE D20MX, 20 GE INFORMATION D20MX HARDWARE USER’S MANUAL CHAPTER 1: BEFORE YOU START Figure 1: D20 non-VME chassis - power supply switch and fuses This chassis contains the WESTERM D20M+ SS termination panel, which is attached directly to the back of the assembly; see Figure 2. Figure 2: D20 non-VME backplane D20 non-VME Chassis Power Supply Switch Power Supply Fuses D20 Non-VME Chassis Power Supply Connector Block WESTERM D20M+ SS Termination Panel

  • GE D20MX, CHAPTER 2: INSTALLING THE D20MX D20MX HARDWARE USER’S MANUAL GE INFORMATION 37 Figure 12: 0 V cable connection Required tools and materials Before beginning the installation procedures, have the following tools and equipment available: • Appropriate device cables for D.20 connections (GE part number 977-0089) • For D20MX Non-VME with Dual 10/100/1000Base-TX (part number 526-3001): CAT5 network cables for RJ-45 Ethernet connections (GE part number 977-0280 or equivalent) • For D20MX Non-VME with Dual 100Base-FX (part number 526-3003) and D20MX Non- VME with Dual 100Base-FX Fiber Optic Card (part number 526-3005): multi-mode duplex fib

  • GE D20MX, APPENDIX D: USING CONFIGPRO WITH D20MX D20MX HARDWARE USER’S MANUAL GE INFORMATION 131 6. Click Next. Result: The ConfigPro Application Installer - Installation Complete window appears. 7. Click Finish.

  • GE D20MX, 114 GE INFORMATION D20MX HARDWARE USER’S MANUAL APPENDIX D: USING CONFIGPRO WITH D20MX 5.3.5. While in the D20MX device created in step 1, double-click and go to the System Point Database tab which contains the Wesmaint II+ application. Right-click on the RADIUS Role Table [B014RADR] and import the B014RADR settings previously exported. Select the B014RADR.CSV file and click Select. 5.4. Configure the IP Redundancy Monitor [B152] application. Note: If the IP redundancy [B152] application in the DCA is enabled, its pseudo point descriptions must be correctly set. Complete th

  • 36 GE INFORMATION D20MX HARDWARE USER’S MANUAL CHAPTER 2: INSTALLING THE D20MX Figure 11: Cable to fiber optic daughter card 8. If the D20MX is being installed in a VME chassis, connect the 0 V cable (part number 975-1237): 8.1. Connect the bare end of the 0 V cable wire to the O V connector on the WESTERM terminal block TB2-9. 8.2. Remove the wire from

  • CHAPTER 5: CONFIGURING THE SOFTWARE D20MX HARDWARE USER’S MANUAL GE INFORMATION 77 NOTE All users that existed in the transferred D20/D200 configuration now have the default password: changeme. Change these passwords using the passwd command in the D20MX Shell. Refer to the WESMAINT II+ for D20MX Configuration Guide B014- 0NCG for details of this command. NOTE I

  • GE D20MX, CHAPTER 3: CONNECTING TO DEVICES AND NETWORKS D20MX HARDWARE USER’S MANUAL GE INFORMATION 49 RS-232 The RS-232 port on the D20MX is used to access the WESMAINT II+ facility and to transfer code and configuration data to the D20MX. You can use a VT100-compatible terminal or terminal emulation program to directly access the WESMAINT II+ facility. SGConfig's Terminal Emulator is an example of a suitable terminal emulation program. The RS-232 port is connected to the D20MX front panel and is also routed to the rear panel as (COM0). The def

  • GE D20MX, 44 GE INFORMATION D20MX HARDWARE USER’S MANUAL CHAPTER 3: CONNECTING TO DEVICES AND NETWORKS Twisted-pair Ethernet (for 526-3001 only) The10/100/1000BASE-T variant of the D20MX can connect to one or two networks through two twisted-pair Ethernet connections. In single-IP mode this causes the two Ethernet connections to use the same MAC address and IP address. Port 1 is the primary port and Port 2 is the secondary port. When the system detects a signal on Port 1, Ethernet traffic takes place on Port 1. When the system detects loss of signal on Port 1, Ethernet traffic takes place on port 2. All RJ-45 connectors have the same signal definition. However, the

  • GE D20MX, CHAPTER 4: POWERING-UP AND TESTING D20MX HARDWARE USER’S MANUAL GE INFORMATION 59 Check that fail-over is functioning correctly To check that fail-over is functioning correctly for the event of hardware failure: 1. On the front of the RS-232 Panel, check that CCU A LED is illuminated, which shows that CCU A is Active. NOTE Both the PWR A and PWR B LEDs should be illuminated. 2. To simulate hardware failure, switch off the Active D20MX at the main power switch on the front of the unit. Result: If the RS-232 is functioning correctly, then it will switch over to the Standby unit and the CCU B LED will illuminate and the CCU A LED will go off. Check that switch-over is functioning c

  • GE D20MX, CHAPTER 5: CONFIGURING THE SOFTWARE D20MX HARDWARE USER’S MANUAL GE INFORMATION 83 Unlock an application group To unlock an application group, an unlock code must be purchased from GE. Please contact Customer Service for the unlock code. Customer Service will ask for the 'Hardware Identifier' of the D20MX that is to have the application group unlocked. This is a unique identifier for each D20MX and cannot be used with any other D20MX (that is, the license is non-transferrable). View the hardware identifier Use the D20M Shell command swlic-info to view the Hardware Identifier. For example: D20M>swlic-info System Information License Information Ut

More Instructions:

DOWNLOAD
DOWNLOAD

Related Products and Documents (Processor):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Generac Power Systems 0E6478 Parts manual generac-power-systems/0e6478-47K.pdf 05 Apr 2023 36 2.42 Mb
2 Philips 200AW8 Operation & user’s manual philips/200aw8-6TF.pdf 13 Mar 2024 87
3 socomec 16A Operation & user’s manual socomec/16a-VYE.pdf 09 Jan 2023 25
4 Balboa Water Group bwa 50350 Easy installation manual balboa-water-group/bwa-50350-5GK.pdf 21 Jul 2022 2
5 Bose SOUND LINK Owner's manual bose/sound-link-PLD.pdf 05 Nov 2022 31 2.91 Mb
6 Hussmann Q1-DC Technical data sheet hussmann/q1-dc-S1N.pdf 16 Aug 2022 26

Similar Resources:

  • Asus

    XEON

    (4 pages)
    ASUS Xeon Installation Guide 1Installation GuideXeon Processor R Xeon Installation ProcedureE338Central Processing Unit (CPU)This motherboard provides two Single Edge Contact (SEC) Slot 2 connectors foreither one or two Intel® Xeon™ processors packaged in an SEC cartridge. Whenonly one processor is used, the other Slot 2 connector must be terminated with …
  • Gigabyte

    GA-945PL-S3E

    (72 pages)
    GA-945PL-S3EIntel® CoreTM 2 Extreme dual-core / CoreTM 2 Duo /Intel® Pentium® D / Pentium® 4 / Celeron® D LGA775 Processor MotherboardUser's ManualRev. 200112ME-945PLS3E-2001R* The WEEE marking on the product indicates this product must not be disposed of with user's other household wasteand must be handed over to a designated collection point …
  • Intel

    E2180 - Pentium Dual-Core 2.00GHz 800MHz 1MB Socket 775 CPU

    (148 pages)
    Document Number: 317804-010 Intel® Core™2 Duo Processor, Intel® Pentium® Dual Core Processor, and Intel® Celeron® Dual-Core Processor Thermal and Mechanical Design Guidelines Supporting the: - Intel® Core™2 Duo Processor E6000 Δ and E4000 Δ Series - Intel® Pentium® Dual Core Processor E2000 Δ Series - Intel® Celeron® Dual-Core Proce …
  • Pico Macom

    SSP-10/2150A

    (8 pages)
    PICO MACOM, INC. 12500 Foothill Blvd. • Lakeview Terrace, CA 91342 • (818) 897-0028 • (800) 421-6511 • FAX (818) 834-7197PICO MACOM,INC.SATELLITESIGNALPROCESSORInstallationAndOperationManualDoc. No.OM2968-1 REV. ADate: 4/23/01SSP-10/2150A …
  • Asus

    BM1AD

    (2 pages)
    12 . Connect one end of the power cord to the power connector and the other end to a wall power outlet. . Collegare un’estremità del cavo di alimentazione al con-nettore dell’alimentazione e l’altra estremità ad una presa elettrica a muro. . Ligue uma das extremidades do cabo de alimentação ao conector de alimentação e a outra ex …
  • Peavey

    Dual Deltafex

    (60 pages)
    For information on other great Peavey products, go to your local Peavey dealer or visit us online at www.peavey.comDigital Effects Processor Owner's ManualDual DeltaFex® …

Comments, Questions and Opinions: