Text of GE JV535 User Guide:

  • GE JV535, Range Hoods Vented www.GEAppliances.ca 350A4502P662 29-5643 04-08 ATS Safety Information . . . . . . . . . . . 2 Operating/Care and Cleaning Instructions Charcoal Filters . . . . . . . . . . . . . . .4 Grease Filters . . . . . . . . . . . . . . . .3 Hood Lights . . . . . . . . . . . . . . . . .4 Hood Surfaces . . . . . . . . . . . . . . . .4 Stainless Steel Surfaces . . . . . . . . .4 Vent Controls . . . . . . . . . . . . . . . .3 Installation Instructions . . .5–14 Troubleshooting Tips . . . . . . . .15 Consumer Support Consumer Support . . .Back Cover Warranty . . . . . .

  • 2 READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY. READ AND SAVE THESE INSTRUCTIONS SAFETY PRECAUTIONS IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manu

  • GE JV535, 3 Operating Instructions Installation Instructions Troubleshooting Tips Consumer SupportSafety Instructions Using the hood controls. Throughout this manual, features and appearance may vary from your model. FAN Control Turn to LO, MED, HI or MAX as needed. Continuous use of the fan system while cooking helps keep the kitchen comfortable and less humid. It also reduces cooking odors and soiling moisture that create a frequent need for cleaning. LIGHT Control Turn to HI while cooking or to NITE for use as a night light. FAN

  • GE JV535, 4 To clean the hood surface, use a hot, damp cloth with a mild detergent suitable for painted surfaces. Use a clean, hot, damp cloth to remove soap. Dry with a dry, clean cloth. Do not use steel-wool pads or other abrasive cleaners. They will scratch the surface. Wipe with a clean, hot, damp cloth after using cleansers. Painted Surfaces (on some models) Do not use a steel-wool pad; it will scratch the surface. Shake bottle well. Place a small amount of CERAMA BRYTE ® Stainless Steel Cleaning Polish and Conditioner on a dry cloth or dry paper towel. Clean a small area (approximately 8” x 8”/20.3 cm x 20.3

  • GE JV535, BEFORE YOU BEGIN 5 Read these instructions completely and carefully. • IMPORTANT – Save these instructions for local inspector’s use. • IMPORTANT – Observe all governing codes and ordinances. • Note to Installer – Be sure to leave these instructions with the Consumer. • Note to Consumer – Keep these instructions for future reference. • Skill level – Installation of this appliance requires basic mechanical and electrical skills. • Completion time – 1–3 hours • Proper installation is the responsibility of the installer. • Product failure due to improper installation is not covered under the Warranty. • Use only with approved co

  • GE JV535, 6 3¼” x 10” Rectangular Transition to 6” Round = 4.5 ft. 7” Round 90° Elbow = 8 ft. 7” Roof Cap = 30 ft. Follow the guidelines for proper duct sizing in the ducting charts. Installation Instructions MAXIMUM DUCT LENGTH: For satisfactory air movement, the total duct length of a 3¼” x 10” rectangular, 6” or 7” diameter round duct should not exceed 65 equivalent feet. DUCTING CHART—JV5 Series Models 0 25 50 75 100 125 150 175 Equivalent Length (feet) 300 250 200 150 Air Volume (CFM) 3 1 /4” x 10” Rectangular 7” Round • • • • • • • • �

  • GE JV535, DUCT EQUIVALENT NUMBER PIECES LENGTH x USED = TOTAL 3¼” x 10” 1 Ft. x ( ) = Ft. Rect., straight 7” Round, 1 Ft. x ( ) = Ft. straight 6” Round, 1 Ft. x ( ) = Ft. straight 3¼” x 10” 8.5 Ft. x ( ) = Ft. Rect. 90° elbow 3¼” x 10” 7 Ft. x ( ) = Ft. Rect. 45° elbow 3¼” x 10” 24 Ft. x ( ) = Ft. Rect. 90° flat elbow 3¼” x 10” 45 Ft. x ( ) = Ft. Rect. (7 ft. w/o wall cap damper) x ( ) = Ft. with damper 3¼” x 10” 4.5 Ft. x ( ) = Ft. Rect. to 6” round transition 3¼” x 10” 11.5 F

  • GE JV535, PART QUANTITY Metal Grease Filters 2 Mounting Screws 4 Exhaust Adaptor/Damper 1 (for 3¼” x 10” rect. venting) Exhaust Adaptor Screws 1 Exhaust Adaptor 1 (for 7” round venting) • If the unit is damaged in shipment, return the unit to the store in which it was bought for repair or replacement. • If the unit is damaged by the customer, repair or replacement is the responsibility of the customer. • If the unit is damaged by the installer (if other than the customer), repair or replacement must be made by arrangement between customer and installer. DAMAGE—SHIPMENT/INSTALLATION PARTS INCLUDED MOUNTING SPACE NOTES: • This range hood is for installation over ranges up

  • GE JV535, 9 Outside top exhaust (Vertical duct—3¼” x 10” Rectangular) Outside rear exhaust (Horizontal duct—3¼” x 10” Rectangular) Outside top exhaust (Vertical duct — 7” Round) A C B Recirculating (Non-vented ductless — Optional for JV5 Series models only) D Installation Instructions CHOOSE VENT OPTION Determine the vent option that your installation will require from the following choices: The outside vent exhaust option that your installation requires will determine the hood knockouts that you will use. NOTE: Only JV5 Se

  • GE JV535, 10 REMOVE EXHAUST ADAPTOR Remove the 7” round exhaust adaptor from the top of the hood. Set it aside along with its mounting screws. NOTE: Save the screws for 3¼” x 10” rectangular ducted installation, if that is your chosen venting option. 7” round exhaust adaptor REMOVE FILTERS Remove the protective shipping film from the edges of the metal grease filters. Press the filter locks back and lift the filters out. Set them aside. REMOVE WIRING COVER FROM THE JUNCTION BOX Remove the wiring cover from inside the hood. Set the cover and its mounting screw aside. Wiring cover REMOVE WIRING KNOCKOUT Remove either the top or the back wiring knockout as needed and install an appro

  • 11 REMOVE DUCT KNOCKOUT(S) If recirculating, non-vented ductless (optional for JV5 Series models only), see note below and skip to Step 9 D and proceed. The JV6 Series models cannot be recirculated. Using a flat blade screwdriver, remove the appropriate duct knockout(s) from the top or back of the hood. 3¼” x 10” Rectangular vertical discharge. Remove top recta

  • GE JV535, 12 MARK HOLES Select the vent option that your installation will require and proceed to that section: Hood mounting screws (4) 13 15 / 16 ” (30” hood) 16 15 / 16 ” (36” hood) 13 15 /16 ” (30 ” hood) 16 15 /16 ” (36 ” hood) Cabinet front Center line Electrical access hole (in cabinet bottom) Wood shims (recessed- bottom cabinets only) Vertical duct access hole 10 1 /2” 1 1 / 4 ” 2” 12 9 /16” 5” 1 1 /4” A. Outside top exhaust (Vertical duct–3 1 /4 ” x 10 ” Rectangular) • Use the diagram or the hood as a template and mark the locations on the cabinet for ductwork, electrical wiring

  • GE JV535, 13 Installation Instructions CUT HOLES Cut holes at marked locations for duct and electrical wiring. For the vertical duct, cut out ¾” extra toward the front of the cabinet so you can move the duct freely when installing the hood. It may also ease installation by cutting the hole 10½” instead of 10”. FOR RECESSED-BOTTOM CABINETS ONLY RUN WIRES Run the electrical wires through the wall or cabinet according to National Electrical Code and applicable local codes. NOTE: DO NOT turn the power on until installation is complete. 12 11 13 SCREW IN PARTWAY Drive a mounting screw (from the hardware packet) partway into each center of the na

  • GE JV535, TROUBLESHOOTING CHECKLIST If the hood seems to be operating at high speed when the control is not set on high, or if ventilation seems inadequate, check the following: ❏ Knockouts not removed from hood. ❏ Damper blade not opening. ❏ Reduced airflow because the duct is too small or the duct length is too long. ❏ The duct is blocked. ❏ Undersized or restrictive wall or roof cap. REPLACE WIRING COVER Replace the wiring cover. 14 FOLLOW ELECTRICAL CODE Complete the electrical wiring according to National Electrical Code and local codes. NOTE: This hood must be permanently grounded. Connect house wiring (120 VAC) to hood wiring. CONNECT WIRING

  • GE JV535, 16 Before you call for service… Troubleshooting Tips Save time and money! Review the following chart first and you may not need to call for service. Problem Possible Causes What To Do Fan does not operate A fuse may be blown or a • Replace fuse or reset circuit breaker. when the switch is on circuit breaker may be tripped. Fan fails to circulate air Excessively soiled filter. • Wash and replace the filters. See the Reusable or moves air more slowly Metal Grease Filters section. than normal • Replace the filter if it is too soiled to clean. If it is not soiled, or if replacing the filter does not solve the problem, call for service. Fan con

  • GE JV535, 17 OWNERSHIP REGISTRATION P.O. BOX 1780 MISSISSAUGA, ONTARIO L4Y 4G1 (FOR CANADIAN CONSUMERS ONLY - POUR RÉSIDENTS CANADIENS SEULEMENT) Please place in envelope and mail to: Veuillez mettre dans une enveloppe et envoyez à :

  • 18 CUT ALONG THIS LINE AND RETURN CARD – THANKS DÉCOUPEZ ICI ET ENVOYEZ LA FICHE – MERCI For Canadian Customers Pour les consommateurs canadiens OWNERSHIP REGISTRATION CERTIFICATE – FICHE D’INSCRIPTION DU PROPRIÉTAIRE Please register your product to enable us to contact you in the remote event a safety notice is issued for this product and to allow for

  • 19 Safety Instructions Operating Instructions Installation Instructions Troubleshooting Tips Consumer Support Range Hood Warranty. For The Period Of: Mabe Will Replace: One Year Any part of the range hood which fails due to a defect in materials or workmanship. From the date of the During this full one-year warranty, Mabe will also provide, free of charge, all labor and original p

  • GE JV535, Consumer Support. GE Appliances Website GEAppliances.ca Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day, any day of the year! For greater convenience and faster service, you can now download Owner’s Manuals, order parts or even schedule service on-line. Schedule Service GEAppliances.ca Expert Mabe repair service is only one step away from your door. Get on-line and schedule your service at your convenience 24 hours any day of the year! Or call 1-800-461-3636 during normal business hours. Extended Warranties GEAppliances.ca Purchase a GE extended warranty and l

Related Products and Documents (Ventilation Hood):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Cuisinart CH-4DC - Die-Cast Elite Collection Chopper/Grinder Instruction booklet cuisinart/ch-4dc-die-cast-elite-collection-chopper-grinder-1ZY.pdf 12 Apr 2023 18 0.57 Mb
2 Euro-Pro Bravetti F1011H Owner's manual euro-pro/bravetti-f1011h-9A1.pdf 04 Aug 2023 6 0.35 Mb
3 OPTICOM LCDI-12 Datasheet opticom/lcdi-12-771.pdf 21 Jun 2023 1
4 Compaq 231027-002 - ProLiant - DL320R01 Reference manual compaq/231027-002-proliant-dl320r01-L63.pdf 04 Jan 2024 131 2.13 Mb
5 Roland METAZA MPX-70 Operation & user’s manual roland/metaza-mpx-70-LL6.pdf 02 Aug 2022 88 3.31 Mb
6 Genelec 1034BC Operating manual genelec/1034bc-QI3.pdf 20 Nov 2023 6 0.38 Mb

Similar Resources:

  • Canarm

    ALX SERIES

    (10 pages)
    ALX SERIES SPUN ALUMINUM EXHAUSTEROPERATION INSTRUCTIONS AND PARTS MANUALREAD AND SAVE THESE INSTRUCTIONSGENERAL SAFETY1. All electrical work must be done in accordance with all applicable electrical codes by a qualified electrician.2. Prior to wiring ensure the power supply is locked in the OFF position and that the motor nameplate voltage matches the sup …
  • Halton

    EcoloAir 3000CFM

    (29 pages)
    Operators Manual for EcologyManual providesOperation, Maintenance and Service InstructionsForm#: OM020_ECOLOGY Date: May 2017 - Rev 5EcoloAir Unit3000CFM, 4000CFM, 5000CFM, 6000CFM, 8000CFM, 10000CFM, 12000CFM, 15000CFM, 18000CFM, 20000CFM, 24000CFM, 28000CFM, 32000CFM, 36000CFM, 40000CFMUL 1978 “Standard for Grease Ducts”, UL 710, “Exhaust Hoods for …
  • Siemens

    LF959RB51

    (12 pages)
    5HJLVWHU\RXUSURGXFWRQOLQHVLHPHQVKRPHEVKJURXSFRPZHOFRPH[en]Instruction manual Extractor hood LF959RB51, LF259RB51, LF959RA51B, LF959RB51B, LF959RB21, LF959RB21B …
  • Electrolux

    316488522

    (21 pages)
    Installation, Use & Care Guide30” and 36” Free-Standing Range HoodGuia de Instalación, Uso y Cuidado30” y 36” Campana extractoraGuide d’installation, utilisation et d’entretien30” et 36” Hotte aspiranteEI30WC60GS + EI36WC60GS 316488522 …
  • Gorenje

    DF 6115 E

    (112 pages)
    DF 6115 E DF 6115 W DF 6116 E DF 6116 BX DF 6116 AX DE Montage- und Gebrauchsanweisung EN Instruction on mounting and use IT Istruzioni di montaggio e d'uso FR Prescriptions de montage et mode d’emploi ES Montaje y modo de empleo PT Instruções para montagem e utilização NL Montagevoorschriften en gebruiksaanwijzingen DA …
  • IKEA

    LAGAN

    (4 pages)
    ENGLISH Examples of the load of the basketsDEUTSCH Beispiele für die Beladung der KörbeFRANÇAIS Exemples de chargement des paniersITALIANO Esempi di carico dei cestiDANSK Eksempel på placering i kurveneNORSK Eksempler på belastning av kurveneSUOMI Esimerkki korien täyttömäärästäSVENSKA Exempel på last i korgarnaÍSLENSK Dæmi um þá þyngd sem m …