  • Panasonic CS-E18HKEW, 70 <Model: CU-E18HKE> (Note) • All parts are supplied from PHAAM, Malaysia (Vendor Code: 061). • “O” marked parts are recommended to be kept in stock. [PHAAM] Printed in Malaysia SSSC0712 - 00 REF. NO. DESCRIPTION & NAME QTY. CU-E18HKE REMARKS 1 CHASSY ASS’Y 1 CWD50K2085 2 ANTI-VIBRATION BUSHING 3 CWH50077 3 COMPRESSOR 1 5CS130XAD04 O 4 NUT-COMPRESSOR MOUNT 3 CWH56000J 5 SOUND PROOF MATERIAL 1 CWG302302 6 FAN MOTOR BRACKET 1 CWD541054 7 FAN MOTOR 1 CWA981166J O 8 SCREW - FAN MOTOR BRACKET 2 CWH551060J 9 SCREW - FAN MOTOR MOUNT 3 CWH551106J 10 PROPELLER FAN ASSY 1 CWH03K1016 11 NUT - PROPELLER FAN 1 CWH56

  • Panasonic CS-E18HKEW, 51 14 Servicing Mode 14.1. Auto OFF/ON Button 1. AUTO OPERATION MODE The Auto operation will be activated immediately once the Auto OFF/ON button is pressed. This operation can be used to operate air conditioner with limited function if remote control is misplaced or malfunction. 2. TEST RUN OPERATION (FOR PUMP DOWN/SERVICING PURPOSE) The Test Run operation will be activated if the Auto OFF/ON button is pressed continuously for more than 5 seconds. A “beep” sound will occur at the fifth seconds, in order to identify the starting of Test Run operation (Forced cooling operation). Within 5 minutes after Forced cooling o

  • Panasonic CS-E18HKEW, 48 13.1.5. Compressor Overheating Prevention Control Instructed frequency for compressor operation will be regulated by compressor discharge temperature. The changes of frequency are as below figure. If compressor discharge temperature exceeds 112qC, compressor will be stop, occurs 4 times per 20 minutes, timer LED will be blinking (“F97” is to be confirmed). 13.2. Protection Control For Cooling & Soft Dry Operation 13.2.1. Outdoor Air Temperature Control The compressor operating frequency is regulated in accordance to the outdoor air temperature as shown in the diagram below. This control will

  • Panasonic CS-E18HKEW, 57 16 Disassembly and Assembly Instructions 16.1. Indoor Electronic Controllers, Cross Flow Fan and Indoor Fan Motor Removal Procedures 16.1.1. To remove front grille 16.1.2. To remove power electronic controller WARNING High Voltage are generated in the electrical parts area by the capacitor. Ensure that the capacitor has discharged sufficiently before proceeding with repair work. Failure to heed this caution may result in electric shocks.

  • 37 12.1.5. Automatic Operation • This mode can be set using remote control and the operation is decided by remote control setting temperature, remote control operation mode, indoor intake air temperature and outdoor air temperature. • During operation mode judgment, indoor fan motor (with speed of Lo-) and outdoor fan motor are running for 30 seconds to de

  • Panasonic CS-E18HKEW, 46 Error Reset Method • Press “OFF/ON” button to OFF the operation. • Press AUTO OFF/ON button at indoor unit to OFF the operation. • OFF Timer activates. • Press “e-ion” button during e-ion individual mode. • Power supply reset. iii. e-ion breakdown Judgement Method • When hi-feedback voltage (at microcontroller) supplied to filter during e-ion stop, due to PCB or filter’s high voltage power supply damage. • Operations except e-ion continue. Both Timer indicator and e-ion indicator blink. Troubleshooti

  • Panasonic CS-E18HKEW, 49 13.2.2. Cooling Overload Control i. Pipe temperature limitation/restriction • Detects the Outdoor pipe temperature and carry out below restriction/limitation (Limit the compressor Operation frequency) • The compressor stop if outdoor pipe temperature exceeds 63qC. • If the compressor stops 4 times in 20 minutes, Timer LED blinking (F95: outdoor high pressure rise protection) 13.2.3. Dew Prevention Control 1 1. To prevent dew formation at indoor unit discharge area. 2. This control activated if: • Outdoor air temperature and Indoor pipe temperature judgment by micr

  • Panasonic CS-E18HKEW, 11 CU-4E27CBPG Three-room Operation 2.2 + 2.2 + 2.2 Cooling 6.60 2.2 - 7.8 1.66 0.41 - 2.49 7.40 Heating 8.61 3.1 - 10.4 1.99 0.50 - 3.25 8.80 2.2 + 2.2 + 2.8 Cooling 7.00 2.5 - 8.1 1.89 0.46 - 2.85 8.25 Heating 8.80 3.2 - 10.4 2.01 0.51 - 3.22 8.85 2.2 + 2.2 + 3.2 Cooling 7.30 2.5 - 8.2 1.98 0.46 - 2.79 8.70 Heating 8.90 3.2 - 10.4 2.03 0.51 - 3.22 8.95 2.2 + 2.2 + 4.0 Cooling 7.80 2.6 - 8.2 2.33 0.46 - 2.83 10.30 Heating 9.20 3.2 - 10.4 2.15 0.51 - 3.18 9.50 2.2 + 2.2 + 5.0 Cooling 8.00 2.8 - 8.3 2.46 0.49 - 2.82 10.80 Heating 9.40 3.2 - 10.4 2.12 0.51 - 3.18 9.30 2.2 + 2.8

  • Panasonic CS-E18HKEW, 13 CU-4E27CBPG Four-room Operation 2.2 + 3.2 + 4.0 + 4.0 Cooling 8.00 2.9 - 9.1 2.09 0.52 - 2.86 9.20 Heating 9.40 4.2 - 10.6 2.06 0.70 - 3.06 9.05 2.8 + 2.8 + 2.8 + 2.8 Cooling 8.00 2.8 - 8.8 2.11 0.49 - 2.84 9.30 Heating 9.40 3.9 - 10.5 2.03 0.66 - 3.08 8.95 2.8 + 2.8 + 2.8 + 3.2 Cooling 8.00 2.8 - 8.9 2.09 0.49 - 2.87 9.20 Heating 9.40 4.0 - 10.5 2.06 0.68 - 3.10 9.05 2.8 + 2.8 + 2.8 + 4.0 Cooling 8.00 2.9 - 8.9 2.12 0.52 - 2.85 9.30 Heating 9.40 4.1 - 10.5 2.04 0.70 - 3.07 8.95 2.8 + 2.8 + 2.8 + 5.0 Cooling 8.00 2.9 - 8.9 2.11 0.52 - 2.85 9.30 Heating 9.40 4.2 - 10.5 2.07 0.70 - 3.07 9.15 2.8 + 2.8 + 3.2 + 3.2 Cooling 8.00 2.9 - 9.0 2.08 0.50 - 2.87 9.15 H

  • Panasonic CS-E18HKEW, 6 1. Cooling capacities are based on indoor temperature of 27qC Dry Bulb (80.6qF Dry Bulb), 19.0qC Wet Bulb (66.2qF Wet Bulb) and outdoor air temperature of 35qC Dry Bulb (95qF Dry Bulb), 24qC Wet Bulb (75.2qF Wet Bulb) 2. Heating capacities are based on indoor temperature of 20qC Dry Bulb (68qF Dry Bulb) and outdoor air temperature of 7qC Dry Bulb (44.6qF Dry Bulb), 6qC Wet Bulb (42.8qF Wet Bulb) Note • Specifications are subject to change without notice for further improvement. Fan Type Cross-

  • Panasonic CS-E18HKEW, 10 CU-3E23CBPG Three-room Operation 2.2 + 2.8 + 5.0 Cooling 6.80 2.8 - 8.3 1.95 0.49 - 2.79 8.50 Heating 8.60 3.5 - 9.0 1.92 0.56 - 2.73 8.45 2.2 + 3.2 + 3.2 Cooling 6.80 2.7 - 8.3 1.97 0.46 - 2.80 8.60 Heating 8.60 3.2 - 9.1 1.91 0.50 - 2.71 8.35 2.2 + 3.2 + 4.0 Cooling 6.80 2.8 - 8.3 1.95 0.49 - 2.80 8.50 Heating 8.60 3.2 - 9.0 1.89 0.50 - 2.71 8.25 2.8 + 2.8 + 2.8 Cooling 6.78 2.6 - 8.1 1.94 0.46 - 2.82 8.50 Heating 8.58 3.2 - 9.0 1.91 0.51 - 2.76 8.35 2.8 + 2.8 + 3.2 Cooling 6.80 2.7 - 8.2 1.96 0.49 - 2.79 8.60 Heating 8.60 3.2 - 9.0 1.92 0.51 - 2.76 8.45 2.8 + 2.8 + 4.0 Cooling 6.80 2.8 - 8.2 1.95 0.49 - 2.79 8.50 Heating 8.60 3.3 - 9.0 1.90 0.53 - 2.76 8.35

  • Panasonic CS-E18HKEW, 19 6 Refrigeration Cycle Diagram Piping size Rated Length (m) Max Elevation (m) Min. Piping Length (m) Max. Piping Length (m) Additional Refrigerant (g/m) Model Gas Liquid E18HKE 1/2” 1/4” 5 15 3 20 20 * If piping length is over common length, additional refrigerant should be added as shown in the table.

  • Panasonic CS-E18HKEW, 7 2.2. Outdoor Unit: CU-3E18EBE Outdoor unit Indoor unit combination Operation mode Capacity (kW) Power Input (kW) Current (A) Operation Class (kW) Rating mini - max Rating mini - max CU-3E18EBE One-room Operation 2.2 Cooling 2.20 1.8 - 2.9 0.50 0.34 - 0.81 2.5 Heating 3.20 1.2 - 4.1 0.74 0.30 - 1.23 3.7 2.8 Cooling 2.80 1.8 - 2.9 0.70 0.34 - 0.81 3.3 Heating 4.00 1.2 - 4.3 1.05 0.30 - 1.23 5.0 3.2 Cooling 3.20 1.8 - 3.8 0.80 0.34 - 1.36 3.7 Heating 4.50 1.2 - 5.8 1.23 0.30 - 2.10 5.8 4.0 Cooling 4.00 1.8 - 4.3 1.24 0.34 - 1.99 5.6 Heating 5.60 1.2 - 6.8 1.72 0.30 - 2.93 7.7 5.0 Cooling 5.00 1.9

  • Panasonic CS-E18HKEW, 41 12.5. ON Timer Control ON timer can be set using remote control, the unit with timer set will start operate earlier than the setting time. This is to provide a comfortable environment when reaching the set ON time. 60 minutes before the set time, indoor (at fan speed of Lo-) and outdoor fan motor start operate for 30 seconds to determine the indoor intake air temperature and outdoor air temperature in order to judge the operation starting time. From the above judgment, the decided operation will start operate earlier than the set time as shown below. 12.6. OFF Timer Control OFF timer can be set using remote control, the unit with timer

  • Panasonic CS-E18HKEW, 39 1. Automatic vertical airflow direction can be set using remote control; the vane swings up and down within the angles as stated above. For heating mode operation, the angle of the vane depends on the indoor heat exchanger temperature as Figure 1 below. When the air conditioner is stopped using remote control, the vane will shift to close position. 2. Manual vertical airflow direction can be set using remote control; the angles of the vane are as stated above and the positions of the vane are as Figure 2 below. When the air conditioner is stopped using remote control, the vane will shift to close position. 12.2.2. Horizontal Airflow 1.

  • Panasonic CS-E18HKEW, 44 g. Timer Control • When ON timer activates when unit stops, previous operation resumes without Patrol operation. • When ON timer activates during any operation, no change and carry on current operation. • When OFF timer activates during any operation, all operation stops. h. Power failure • During Patrol individual operation, if power failure occurs, after power resumes, Patrol individual operation resumes immediately. • During combination operation, if power failure occurs, after power resumes combination operation resume immediately. 12.10. e-ion Operation A. Purpose T

  • Panasonic CS-E18HKEW, 38 [Heating] • According to indoor pipe temperature, automatic heating fan speed is determined as follows. B. Feedback control • Immediately after the fan motor started, feedback control is performed once every second. • During fan motor on, if fan motor feedback 2550 rpm or < 50 rpm continue for 10 seconds, then fan motor error counter increase, fan motor is then stop and restart. If the fan motor counter becomes 7 times, then H19 - fan motor error is detected. Operation stops and cannot on back. 12.1.7. Outdoor Fan Motor Operation Outdoor fan motor is operated with one fan speed only. It starts when compressor starts operation and it stops 30 seconds after compressor sto

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Sony NW-E7 Operating instructions manual sony/nw-e7-7SI.pdf 26 Nov 2022 24 0.42 Mb
2 ARM ARM926EJ-S Technical reference manual arm/arm926ej-s-Z4J.pdf 20 Aug 2023 248
3 KitchenAid Artisan 5KTT890 Manual to expert results kitchenaid/artisan-5ktt890-F9J.pdf 31 Oct 2022 146
4 MTD 139-390A Owner's manual mtd/139-390a-CW6.pdf 04 Apr 2023 29
5 Vivotek IP8172 Quick installation manual vivotek/ip8172-M12.pdf 15 Jun 2023 12 5.17 Mb
6 Jenn-Air JMV8186AA Installation instructions manual jenn-air/jmv8186aa-H5T.pdf 21 Jun 2023 24

Similar Resources:

  • Fujitsu

    AUU7RLF

    (303 pages)
    AIR CONDITIONERMulti : 2rooms type 3rooms type 4rooms typeINDOOROUTDOORDESIGN & TECHNICAL MANUALAUU7RLFAUU9RLFAUU12RLFAUU18RLFARU7RLFARU9RLFARU12RLFARU18RLFAOU18RLXFZAOU24RLXFZAOU36RLXFZ1ARU24RLFASU7RLF1ASU9RLF1ASU12RLF1ASU7RLFASU9RLFASU12RLFASU9RLS2ASU12RLS2ASU15RLS2ASU18RLFASU24RLFAGU9RLFAGU12RLFAGU15RLF …
  • Daikin

    FHQ18PVJU

    (94 pages)
    SPLIT SYSTEM Air ConditionersEnglishFrançaisEspañolINSTALLATION MANUALMODELSCeiling suspended typeFHQ18PVJUFHQ24PVJUFHQ30PVJURead these instructions carefully before installation.Keep this manual in a handy place for future reference.This manual should be left with the equipment owner.Lire soigneusement ces instructions avant I’installation.Concerver ce …
  • Samsung

    SGHA436

    (170 pages)
    QUAD BAND SeriesSGH-A436Portable Digital Mobile PhoneUser ManualPlease read this manual before operating your phone, and keep it for future reference.Printed in ChinaCode No.: GH68-14526AEnglish 05/2007. Rev. 1.0 …
  • Panasonic

    CS-PC12MKF

    (87 pages)
    © Panasonic HA Air-Conditioning (M) Sdn. Bhd. 2011.Unauthorized copying and distribution is a violation of law.Order No. PHAAM1101068C3Air ConditionerIndoor Unit Outdoor UnitCS-PC12MKF CU-PC12MKFCS-PC18MKF CU-PC18MKFCS-PC24MKF CU-PC24MKFTABLE OF CONTENTSPAGE PAGE1 Safety Precautions----------------------------------------------- 32 Specifications --------- …
  • Electrolux

    FAH124N2

    (4 pages)
    Product No. FAH124N2T Series TTW/Builder Volts 230/208 BTU-Cooling 12000 BTU Owner's Guide 309000856 Market North America P40L2012.eps FAH124N2T.eps 309201101.eps ELECTROLUX HOME PRODUCTS, INC. P.O. Box 212378, Augusta, GA 30917 Publication No. 5995412938 04/07/09 (EN/SERVICE/KC) 099 ROOM AIR CONDITIONER Model No. FAH124N2 Co …
  • Midea

    M2OC-14HRDN1

    (36 pages)
    ODMI-1103-A GD Midea Refrigeration Equipment Co.,Ltd MULTI SPLIT TYPE, HEAT PUMP AIR CONDITIONERS Technical service manual R410A Multi DC inverter 220~240V-1Ph-50Hz Outdoor units Models M2OC-14HRDN1 M2OC-14HRDN1-Q M2OC-18HRDN1 M2OC1-18HRDN1-Q M3OC1-21HRDN1-Q M3OC-27HRDN1 M3OC1-27HRDN1-Q M4OC-24HRDN1-Q M4OC1-27HRDN1-Q M4OC-27HRDN1 M4OC-3 …

Comments, Questions and Opinions: