  • Generac Power Systems ECOGEN SERIES, 3 The National Electrical Code (NEC) requires the frame and external • electrically conductive parts of the generator to be connected to an approved earth ground. Local electrical codes also may require proper grounding of the generator electrical system. After installing this home standby electrical system, the genera-• tor may crank and start at any time without warning. When this occurs, load circuits are transferred to the STANDBY (genera- tor) power source. To prevent possible injury if such a start and transfer occur, always set the generator’s AUTO/OFF/MANUAL switch to its OFF position before working on equipment and remove the 7.5A

  • Generac Power Systems ECOGEN SERIES, n Only qualified electricians or contractors should attempt such installations, which must comply strictly with applicable codes, stan- dards and regulations. 1.1 UNPACKING/INSPECTION After unpacking, carefully inspect the contents for damage. This standby generator set is ready for installation with a factory • supplied and pre-mounted base pad and has a weather protec- tive enclosure that is intended for outdoor installation only.  If this generator is used to power electrical load circuits normally powered by a utility power source, it is required by code to install a trans- fer switch. The transfer switch must effective

  • Generac Power Systems ECOGEN SERIES, 9 1.10 BATTERY REQUIREMENTS See the Specifications section for correct battery size and rating. 1.11 BATTERY INSTALLATION Fill the battery with the proper electrolyte fluid if necessary and have the battery fully charged before installing it. Before installing and connecting the battery, complete the follow- ing steps: 1. Set the generator's AUTO/OFF/MANUAL switch to OFF. 2. Turn off utility power supply to the transfer switch. 3. Remove the 7.5A fuse from the generator control panel. Battery cables were factory connected at the generator (Figure 1.5). Connect cables to battery posts as follows: 4. Connect the red battery cable (from starter c

  • Generac Power Systems ECOGEN SERIES, 13 Operation Figure 3.1 – Generator Control Panel Escape MAIN FUSE AUTO OFF MANUAL 7.5 AMP Enter Upon first power up of the generator, the display interface will begin an installation assistant. The assistant will prompt the user to set the minimum settings to operate. These settings are Current Date/Time. The maintenance intervals will be initialized when the exercise time is entered (Figure 3.1). If the 12 volt battery is disconnected or the fuse removed, the Installation Assistant will operate upon power restoration. The only difference is the display will only prompt the customer for the current Time and Date. NOTE: The current date/time wi

  • 10   Be sure the utility power supply is turned off and the 7.5A fuse is removed from the gen- erator control panel, or sparking may occur at the battery posts as the cables are attached and cause an explosion. Servicing of the battery is to be performed or supervised by per- sonnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batt

  • 14 Cranking Conditions The following notes apply during cranking cycle. 1. Starter motor will not engage within five (5) seconds of the engine shutting down. 2. The fuel output will not be energized with the starter. 3. The starter and magneto outputs will be energized together. 4. Once the starter is energized the control board will begin look- ing for engine rotation. If

  • Generac Power Systems ECOGEN SERIES, 17 4.3.3 OIL & OIL FILTER CHANGE PROCEDURE To change the oil, proceed as follows: 1. Start the engine by moving the AUTO/OFF/MANUAL switch to MANUAL and run until it is thoroughly warmed up. Then shut OFF the engine by moving the switch to the OFF position. 2. Immediately after the engine shuts OFF, pull the oil drain hose (Figure 4.1) free of its retaining clip. Remove the cap from the hose and drain the oil into a suitable container. 3. After the oil has drained, replace the cap onto the end of the oil drain hose. Retain the hose in the clip. Change the engine oil filter as follows: 1. With the oil drained, remove the old oil filter by turning it

  • Generac Power Systems ECOGEN SERIES, 1.7 FUEL REQUIREMENTS AND RECOMMENDATIONS This unit uses a LP vapor withdrawal system only. This type of system uses the vapors formed above the liquid fuel in the storage tank. Recommended fuels should have a Btu content of at least 2,520 Btus per cubic foot for LP gas. Ask the fuel supplier for the Btu content of the fuel. Required fuel pressure for liquid propane, 10 inches to 12 inches of water column (0.36 to 0.43 psi). The primary regulator for the propane supply is NOT INCLUDED with the generator. NOTE: All pipe sizing, construction and layout must comply NFPA 58 for liquid propane applications. Once the generat

  • Generac Power Systems ECOGEN SERIES, 32 FOR GENERATORS 10KW AND BELOW FEDERAL EMISSION CONTROL WARRANTY STATEMENT YOUR WARRANTY RIGHTS AND OBLIGATIONS The United States Environmental Protection Agency (EPA) and Generac Power Systems, Inc. (Generac) are pleased to explain the Emission Control System warranty on your new 2008 and later equipment. New equipment that use small spark-ignited engines must be designed, built, and equipped to meet stringent anti-smog standards for the federal government. Generac will warrant the emission control system on your generator for the period of time li

  • Generac Power Systems ECOGEN SERIES, EcoGen 6kW Generator Owner's Manual L I S T E D C U S  NOT INTENDED FOR USE IN CRITICAL LIFE SUPPORT APPLICATIONS.  ONLY QUALIFIED ELECTRICIANS OR CONTRACTORS SHOULD ATTEMPT INSTALLATION!  DEADLY EXHAUST FUMES! OUTDOOR INSTALLATION ONLY!

  • Generac Power Systems ECOGEN SERIES, 16 4.1 FUSE The 7.5 amp fuse on the control panel protects the DC control circuit against overload (Figures 3.1 and 3.2). This fuse is wired in series with the battery output lead to the panel. If this fuse ele- ment has melted open, the engine will not be able to crank or start. Replace this fuse using only an identical 7.5 amp replacement fuse. Whenever the fuse is removed or replaced, the exercise timer needs to be reset. 4.2 CHECKING THE ENGINE OIL LEVEL For oil capacities, see the Specifications section. For engine oil recommendations, see the Engine Oil Recommendations section. When low battery levels necessitate running the generator for extended

  • Generac Power Systems ECOGEN SERIES, Introduction .............................................. 1 Read This Manual Thoroughly ................................................1 Safety Rules ............................................. 1 Contents ...............................................................................1 Operation and Maintenance....................................................1 How to Obtain Service ...........................................................1 Standards Index .....................................................................3 General Information ................................. 4 1.1 Unpacking/Inspection .........................

  • Generac Power Systems ECOGEN SERIES, 11 ACTIVATION CHART CHOOSE LANGUAGE TROUBLESHOOTING Display Reads: Use ARROW keys to scroll to desired lan- guage. Press ENTER to select. If the wrong language is chosen, it can be changed later using the “edit” menu. Display Reads: Press ENTER to begin the activation pro- cess. If ESCAPE is pressed instead of ENTER, your generator will only run in manual mode (for test purposes) and NOT ACTIVATED will be displayed. You will need to reconnect the battery and begin with Step 1. Display Reads: If you do not have your activation code, go to www.activategen.com or call 1-888-9ACTIVATE (922-8482). If you already hav

  • Generac Power Systems ECOGEN SERIES, 28 Generac ® Power Systems, Inc. 28 28 ENGINE CONTROLLER VOLTAGE REGULATOR (AVR) ENGINE START BATTERY CHARGER 12 VOLT ENGINE START BATTERY ALTERNATOR BATTERY CHARGER INVERTER TWO-WIRE START BATTERY VOLTAGE SENSING AC DISTRIBUTION PANEL 120/240V DC DISTRIBUTION PANEL 12V/24V/48V BATTERY 12V/24V/48V INVERTER/CHARGER GENERATOR HOUSE HOUSE LOADS HOUSE LOADS 120V/240V CHARGER SUPPLY TWO-WIRE START TWO-WIRE START 24/48V DC 480V AC WIND TURBINE PHOTO VOLTAIC PANEL 120/240V OUTPUT ECO GEN - TYPICAL OFF-GRID APPLICATION SYSTEM DIAGRAM Installation Diagram Drawing No. 0J1319-B

  • 23 Appendix 6.1 MENU SYSTEM NAVIGATION To get to the MENU, use the "Esc" key from any page. It may need to be pressed many times before getting to the menu page. The currently selected menu is displayed as a flashing word. Navigate to the menu required by using the +/- keys. When the menu required is flashing, press the ENTER key. Depending on the menu

  • 18 4.6 BATTERY MAINTENANCE The battery should be inspected per the "Service Schedule" sec- tion. The following procedure should be followed for inspection: 1. Inspect the battery posts and cables for tightness and corro- sion. Tighten and clean as necessary. 2. Check the battery fluid level of unsealed batteries and, if nec- essary, fill with Distilled Water Only. Do not use tap

  • Generac Power Systems ECOGEN SERIES, 1 INTRODUCTION Thank you for purchasing this compact, high performance, air-cooled, engine-driven generator. It is designed to supply electrical power to operate an inverter/battery charger as a component in an off-grid power solution. This unit is factory installed in an all-weather, metal enclosure and is intended exclusively for outdoor installation. This generator will operate using vapor withdrawn liquid propane (LP). NOTE: This generator is suitable for supplying typical residential loads such as Induction Motors (sump pumps, refrigerators, air conditioners, furnaces, etc.), Electronic Components (computer, monitor, TV, etc.), Lighting Loads and Microwaves. READ THIS

  • Generac Power Systems ECOGEN SERIES, 33 EMISSION CONTROL SYSTEM WARRANTY Emission Control System Warranty (ECS warranty) for equipment using small spark-ignited engines: (a) Applicability: This warranty shall apply to equipment that uses small off-road engines. The ECS Warranty period shall begin on the date the new equipment is purchased by/delivered to its original, end-use purchaser/owner and shall continue for 24 consecutive months thereafter. (b) General Emissions Warranty Coverage: Generac warrants to the original, end-use purchaser/owner of the new engine or equipme

  • Generac Power Systems ECOGEN SERIES, 8 General Information Figure 1.4 – Installation Guidelines 18 inches Minimum Distance 36 inches 36 inches 36 inches 60 inches 60 inches Existing Wall No windows or openings in the wall permitted within 5 feet from any point of the generator. Top of Generator 60” Minimum 60” Recommended Minimum From Ends 18 inches Minimum Generator Clearance from windows, doors, any openings in the wall, shrubs or vegetation over 12” in height Clearance from the ends and front of the generator should be 36 inches. This w

  • 7 Install the unit where services will not be affected or obstructed, • including concealed, underground or covered services such as electrical, fuel, phone, air conditioning or irrigation. Where strong prevailing winds blow from one direction, face the • generator air inlet openings to the prevailing winds. Install the generator as close as possible to the fuel supply, to •

  • Generac Power Systems ECOGEN SERIES, Part No. 0J0984 Revision B (05/27/11) Printed in U.S.A. Warranty GENERAC POWER SYSTEMS LIMITED WARRANTY FOR "ECO GEN AIR-COOLED AUTOMATIC STANDBY GENERATORS" For a period of three (3) years or 2000 hours, whichever comes first, from the date of original sale Generac Power Systems, Inc. (Generac) warrants that its standby generator will be free from defects in material and workmanship for the items and period set forth below. Generac will, at its option, repair or replace any part(s) which, upon examination, inspection and testing by Generac or an Authorized/Certified Generac Dealer, is found to be defective. Any e

  • Generac Power Systems ECOGEN SERIES, 21 Maintenance 4.12 SERVICE SCHEDULE ATTENTION: It is recommended that all service work be performed by the nearest Dealer. SYSTEM/COMPONENT PROCEDURE FREQUENCY X = Action R = Replace as Necessary * = Notify Dealer if Repair is Needed. Inspect Change Clean W = Weekly M = Monthly Y = Yearly FUEL Fuel lines and connections* XM LUBRICATION Oil level XW Oil X 2Y or 500 hours of operation.** Oil filter X 2Y or 500 hours of operation.** COOLING Enclosure louvers XXW BATTERY Remove corrosion, ensure dryness XXM Clean and tighten battery terminals XXM Check charge state X R EVERY 6 M Electrolyte level

  • Generac Power Systems ECOGEN SERIES, 19 When valve clearance is correct, hold the pivot ball stud in place with the allen wrench and tighten the rocker arm jam nut. Tighten the jam nut to 174 in/lbs. torque. After tightening the jam nut, recheck valve clearance to make sure it did not change. Install new valve cover gasket.• Re-attach the valve cover.• NOTE: Start all four screws before tightening or it will not be possible to get all the screws in place. Make sure the valve cover gasket is in place. Install spark plugs.• Re-attach the spark plug wire

  • Generac Power Systems ECOGEN SERIES, 5 1.4 THE GENERATOR Figure 1.1 – 6kW, V-twin, GT-530 Engine (door removed) Air Filter External Oil Fill/Dipstick Control Panel Data Label Circuit Breaker Fuel Inlet (back) Fuel Regulator Composite Base Battery Compartment Oil FilterExhaust Enclosure Engine Oil Dipstick Engine Oil Fill Figure 1.2 – Data Label Sample 1.5 SPECIFICATIONS 1.5.1 GENERATOR Fuel Type ....................................................................................... LP vapor only Rated Voltage ........................................................

Related Products and Documents (Portable Generator):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Transonic TC2549MSIPOD Operation & user’s manual transonic/tc2549msipod-PYC.pdf 31 Dec 2023 17
2 Tysso PRP-300 Quick installation manual tysso/prp-300-8YO.pdf 06 Mar 2023 2
3 Amprobe ACD-6 Pro Operation & user’s manual amprobe/acd-6-pro-O4N.pdf 11 Dec 2022 15
4 LG MS2021C Owner's manual lg/ms2021c-1H4.pdf 20 Oct 2023 11
5 Celestron POWER TANK 18774 Instruction manual celestron/power-tank-18774-H1Y.pdf 27 Nov 2023 4
6 Craftsman 919.155350 Owner's manual craftsman/919-155350-U39.pdf 23 Feb 2023 18 0.25 Mb

Similar Resources:

  • Dometic GROUP

    WAECO CoolPower MPS35

    (128 pages)
    CoolPower MPS35DE 4 NetzgleichrichterMontage- und BedienungsanleitungEN 13 Mains rectifierInstallation and Operating ManualFR 22 RedresseurInstructions de montage et de serviceES 31 Rectificador de corrienteInstrucciones de montaje y de usoIT 40 Raddrizzatore di reteIstruzioni di montaggio e d’usoNL 49 NetgelijkrichterMontagehandleiding en gebruiks-aanwijz …
  • LDT

    Digital Professional Series

    (2 pages)
    Littfinski DatenTechnik (LDT) Operating Instruction Adapter (Version A) for Lightsignal-Decoder from the Digital-Professional-Series ! Adap-LS-A (set of 2 pieces) Part-No.: 540012 >> finished module << Compatible for light signals with incandescent lamp …
  • Vector Fog

    VECTORFOG H500

    (11 pages)
    1 INSTRUCTION MANUAL THERMAL FOGGER VECTORFOG H500/H500SF Only fog for short periods at a me, when there is not much wind and moving away from the projeg smoke. It’s ess to read the manufacturer’s instrucons of the chemical being used before you start applying, including dilungo and safety pr� …
  • Briggs & Stratton

    Portable Generator

    (52 pages)
    ®PortableGeneratorOperator'sManualThis generator is rated in accordance with CSA(Canadian StandardsAssociation) standard 022.2 No. 100-04 (motors and generators).BRIGGS & STRATTONPOWER PRODUCTS GROUP, LLCJEFFERSON, WISCONSIN, U.S.A.Printed in U.S.A. Manual No. 197523GS Revision H (03/12/2009) …
  • Impax

    IM1500I

    (20 pages)
    EC DECLARATION OF CONFORMITY4HE MANUFACTURER OF THE PRODUCT COVERED BY THIS $ECLARATION IS.!0 "RANDS ,TD.APIER (OUSE 5NIT  #ORUNNA #OURT7ARWICK 5NITED +INGDOM #6 (14HE MANUFACTURER HEREBY DECLARES THAT THE MACHINE AS DETAILED IN THIS DECLARATION FULFILS ALL THERELEVANT PROVISIONS OF THE -ACHINERY $IRECTIVE AND OTHER APPROPR …
  • GoPower

    JS120

    (5 pages)
    specifications and design liable to modifications without prior noticeJS120 DIESEL GENSETMODEL JS120Stand-by Power @ 60Hz 117kW / 146 kVA Prime Power @ 60Hz 106 kW / 133 kVAStandard FeaturesGeneral features :· Engine (JOHN DEERE , 6068TF220 )· Charge alternator 12 V , Governor:Meca/Mechanical· Alternator (LEROY SOMER , LSA442S7 )· Si …

Comments, Questions and Opinions: