Panasonic MEW01 351 Planning Manual

Panasonic MEW01 351 Manual Online:

3.05, 1882 votes
Panasonic MEW01 351 User Manual
Panasonic MEW01 351 User Guide
Panasonic MEW01 351 Online Manual

Text of Panasonic MEW01 351 User Guide:

  • Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 18 NOTE! In a system where each control unit is independent of the other (i.e. each control unit works like a "standalone" control unit) a single TLON Network may be sufficient. To maintain security, in this case:  All control units shall be of type 5000, i.e. including front panel.  The alarm points and their "belonging" outputs shall be connected to the same control unit.  If fire alarm routing equipment (Fire brigade tx) shall be used, each control unit in the system shall be able to activate

  • Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 148 24 Current consumption The different loop units have different current consumption. Note that some units have much higher current consumption in "active state". To check the current consumption on the COM loops, cable lengths, etc. the tables below can be used. See also dwg. 512-41 and chapter "COM loop cable length", page 145. Also, to get a total current consumption overview and to check if the battery capacity is enough, the tables below can be u

  • Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 127 filtering algorithms (see chapter "Functions / Services / Features", page 89). 18.8 Self diagnosis of internal devices The detectors perform an internal check of some vital functions and components (e.g. the IR-LED). In some modes a separate fault message will be shown in the c.i.e. The following is valid for the different type of detectors: 4352:

  • Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 32 Fan control and indicating panel, for four Fan control panels, each with six LEDs (On / Auto / Off / Running / Stopped / Fault) and three push buttons (On / Auto / Off). One "Reset" switch. Simple or Advanced function for a "Supply air fan" or a "Standard fan". Enhanced function for a "Smoke exhaust", "Smoke spill", "Stair pressurisation" or a "Supply air&q

  • Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 136 A time interval can be copied in one day field and pasted into another day field. Tuesday: Programmed the same way as the Monday. Wednesday: Programmed the same way as the Monday. Thursday: Programmed the same way as the Monday. Friday: Programmed the same way as the Monday. Saturday: Programmed the same way as the Monday. Sunday: Programmed the same way as the Monday. National

  • Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 119  Programmable outputs not activated.  Output for routing equipment (Fire brigade tx) not activated. 17.2 Battery faults For other conventions, see chapter "Security functions", page 153. 17.2.1 FAULT: Battery The following battery check is performed:  The battery charging is turned off every 30 th second.  Battery voltage is checked.  Battery voltage < 24.4 V generates a f

  • Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 121 18 Cyber sensor functions The latest generation of detectors are called "Cyber sensors". The Cyber sensor "family" consists of the following detectors:  Conventional photoelectric smoke detector 4352  Conventional multi detector 4350  Analog photoelectric smoke detector 4301  Analog multi detector 4300 NOTE! NOTE! NOTE! NOTE! NOTE! NOTE! NOTE! The analog detectors 4301 and 4300 can via the address setting tool 3314 be set in

  • Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 12 2.12 Network / TLON ® / LonWorks ® / Echelon / Node / TLON Conn. board / Channel / Backbone net / Router / Repeater Brief explanations to the words/expressions to be found in connection with a "network". See also separate TLON Technical descrip

  • Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 157 shall be used to read a true value instead of a calculated current consumption. A tip: Turn off the main power source (230 V AC) and use e.g. a "clamp current meter" on one of the wires between one of the batteries and the Main board 5010, to read the true total control unit current consumption. An approx. value is displayed via menu H5/A5.

  • Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 158 26 S/W versions Due to continual development and improvement, different S/W versions can be found. Different S/W versions can be found on different markets. The S/W versions listed below were the valid ones when this document was written (the date of this document or date of revision). S/W for: Latest version Required version 5000 / 5001; EBL512 G3 1.1.0 1.1.0 4580; 8 zones expansion board, P.c.b. no. 9287-2B 1.0.3 1.0.2 4580; 8 zones expansion board, P.c.b. n

  • Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 72 13 Output programming Output programming is done in WinG3. See the WinG3 dialog box respectively. See also WinG3 help. 13.1 Type of output Some output types can be collective disabled. Some output types can when activated, be indicated by an LED. The fol

  • Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 156 The relation between the total current consumption in normal state (I TN ) and the backup time. One table for the built-in 28 Ah batteries and one table for the external 65 Ah batteries: NOTE! Theoretical values. Built-in 28 Ah batteries: I TN (A) Backu

  • Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 107 If a fire alarm type A is received, the probability of a real fire is higher than for a fire alarm type B. The alarm receiver can take different actions depending on if it is a type A or B fire alarm. 16.15.1 Fire alarm type B The output shall be programmed (via WinG3) as type "Routing equipment" and have the trigger condition "One detector alarm". The output will be activated for fire alarm from one analog addressable smoke, heat or multi 101 detector only. 16.15.2 Fire alarm

  • Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 24 5.3 Programmable voltage outputs (S0-S3) The 24 V DC outputs S0-S3 are supervised (monitored) 5 . Connections according to dwg 512 G3 – 23. When all connections are done a calibration has to be performed, see chapter "Calibration of supervised outputs", page 110 and the EBL512 G3 Operating Instructions MEW01163, chapter "Calibration of s

  • Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 11 2.2.8 Conventional zone line input / External line Input intended for one or more conventional alarm points. End-of-line device in the last alarm point on the line. 2.3 Output unit Addressable unit with programmable control outputs. Connected to a COM loop (see below). 2.4 Output / Control output Defined or programmable function. Relay output or voltage output (supervised / monitored or not), in the c.i.e. or an output

  • Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 4 14.3.3 Reset interlocking output (H9/C3) ________________ 87 14.3.4 Disable interlocking output (H9/C4) _______________ 87 14.3.5 Re-enable interlocking output (H9/C5) _____________ 87 14.4 Interlocking control expressions ______________________ 87 15 Fire Door Closing __________________________ 88 16 Functions / Services / Features _______________ 89 16.1 Sensor value ________________________________

  • Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 52 equipment requiring 24 V DC with battery backup, e.g. the 3364 unit (see page 47). It also has a "/Mains OK" output (normally low), intended to be connected to the corresponding input on the 3364 unit. A light grey metal housing (HxWxD, 288 x 400 x 95 mm). There is space for two maintenance-free sealed Lead-Acid backup batteries, 2 x 12 V, 7.5 Ah as the second power source. Batteries with higher capacity (up to 65 Ah) have to be pl

  • Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 29 and low voltage states cannot be reached / activated. After alarm reset (in EBL512 G3) the zone line input will return to the normal state. 6.2.2.4 Short-circuit state The short-circuit current limit 13 is exceeded, indicating short-circuit on the zone line. This no

  • Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 3 9.3.1 Web-servers __________________________________ 59 9.4 Other units _______________________________________ 59 9.4.1 Alert Annunciation Controllers ___________________ 59 9.4.2 External LED ________________________________ 60 9.4.3 Alarm devices (sounders, etc.) ___________________ 60 9.4.4 Door release magnets __________________________ 60 9.4.5 Boxes _________________________

  • Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 68 12 Programmable outputs In each control unit are four programmable voltage outputs (S0-S3) and two programmable relay outputs (R0-R1) available. 8 relays expansion boards (4581) and Input and Output expansion board (4583) with three programmable outputs (Output 0-2) can be mounted in each EBL512 G3. See chapter "Expansion boards 458x", page 26. On the COM loop

  • Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 95 Figure 20. An example of the smouldering smoke algorithm for an Analog smoke detector 4301. Explanations to the figure: In this example, the week average sensor value and the decision value are "10" at the "starting point", i.e. due to contamination the smouldering level has been adjusted to "24" (10+14), the pre-warning level to "32" (10+22) and the fire alarm level to "40" (

  • Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 98 FAULT: Loop unit xxx-xx Technical number xxxxxx 16.8 Minimum / Maximum sensor values To find out how the environment is, where an analog detector 33xx / 430x (in NORMAL mode) is mounted, the minimum and maximum sensor values can be studied. The sensor values are continuously picked up and evaluated by the control unit (c.i.e.) for each detector individually. Every value is checked if it is a new minimun or maximum value for that detector. At midnight every day a memory will be updated and th

  • Panasonic MEW01 351, Planning Instructions MEW01351 Revision - Fire Alarm System EBL512 G3 V1.1.x Author: Jan Pettersson Date of issue: 2011-02-11 Date of rev:

  • Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 20 Figure 2. The EBL512 G3 front with display ("Man-Machine- Interface"); The Fire Brigade Panel (FBP) is the upper part and the Control Panel (CP) is the lower part. The look might vary depending on the language, country, etc. (A front with texts in English is shown in the figure). The FBP is used by the fire brigade personnel to see which alarm point(s) / zone(s) having activated fire alarm and to take required operational control of the system.

  • Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 47 address label on which the unit's COM loop address can be written. The Address setting tool (3314) is also used for the mode setting: NORMAL mode: Used for 3361 in system EBL512 G3. 2330 mode: Not used in system EBL512

Related Products and Documents (Smoke Alarm):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Kompernass SILVERCREST KH 1161 Operating instructions manual kompernass/silvercrest-kh-1161-8E4.pdf 04 Jul 2022 50
2 Sony HDR-XR500 Operating manual sony/hdr-xr500-8A7.pdf 30 Oct 2022 131
3 Morphy Richards soupmaker Operation & user’s manual morphy-richards/soupmaker-48I.pdf 09 Dec 2023 12
4 Bell System bell free Installation & operation manual bell-system/bell-free-3Z1.pdf 31 Dec 2023 44
5 Daewoo DTQ 26S1FC Instruction manual daewoo/dtq-26s1fc-664.pdf 30 Mar 2023 27 0.92 Mb
6 Bplus Technology MP2A Operation & user’s manual bplus-technology/mp2a-SKQ.pdf 10 Feb 2024 16

Similar Resources:

  • UniPOS

    FD 3030

    (2 pages)
    TIP FD 3030KULLANMA TALIMATı 01-3030-06-051293GENEL TARİFFD 3030 Optik Etkili Duman Dedektörü, yangın koruma bölgesindeki herhangi bir yangın anında,duman yoğunluğunun sabit bir değerin üzerine çıkması durumunda erken uyarı vermek içindizayn edilmişlerdir. Çalışma prensibi, duman partiküllerinin optik sensör odacığına girereksensor …
  • Kidde

    1SF23/9HI

    (9 pages)
    1Thank you for purchasing a Kidde Fyrnetics alarm. Please read through our guide in full. Kidde Fyrnetics recommends for maximum protection that both ionisation and photo-elec-tric (optical) smoke alarms be installed. Ionisation sensing alarms may detect invisible fireparticles (associated with fast flaming fires) sooner than photoelectric alarms.Photoelectr …
  • Firex

    ADH

    (16 pages)
    SPECIFICATIONSModel Number: ADHElectrical Rating: 120 VAC, 60 HZ, 80mA, max, 9 volt battery back-upInterconnect Quantity: 18 alarms maximum, no more than 12 can be smokealarmsU.L. Alarm Point temperature: 58°C (135°F) fixed temperatureU.L. Maximum ambient temperature at unit: 38°C (100°F)Operating temperature: -23°C to 70°C (-10°F to 158 …
  • BRK electronic

    First Alert SCO1BN

    (2 pages)
    Description:The FCD2BN is an AC-powered plug-in CO alarm. It is microprocessor controlled for accurate andreliable operation. Meets UL2034. Single-button test/silence. Permanent CO sensor.Alarm indicatorlight: Power shines constant red, during Alarm LED flashes when CO alarm levels are detected.Also have malfunction/service mode alert. Loud, 85dB horn. 5-Yea …
  • EMS

    FireCell FCZ-170-111

    (22 pages)
    ©2018 EMS Ltd. All rights reserved. TSD115 Iss2 17/09/2018 AJMWireless RIMProgramming Guide …
  • System Sensor

    2151

    (4 pages)
    D100-04-00 1 I56-581-07R2151 Low ProfilePhotoelectronic Plug-in Smoke DetectorINSTALLATION AND MAINTENANCE INSTRUCTIONS 3825 Ohio Avenue, St. Charles, Illinois 601741-800-SENSOR2, FAX: 630-377-6495www.systemsensor.comBefore Installing Please thoroughly read the System Sensor manual A05-1003, Applications Guide for System Smoke Detectors, wh …

Comments, Questions and Opinions: