Panasonic MEW01 351 Planning Manual
|
Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 18 NOTE! In a system where each control unit is independent of the other (i.e. each control unit works like a "standalone" control unit) a single TLON Network may be sufficient. To maintain security, in this case: All control units shall be of type 5000, i.e. including front panel. The alarm points and their "belonging" outputs shall be connected to the same control unit. If fire alarm routing equipment (Fire brigade tx) shall be used, each control unit in the system shall be able to activate
Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 148 24 Current consumption The different loop units have different current consumption. Note that some units have much higher current consumption in "active state". To check the current consumption on the COM loops, cable lengths, etc. the tables below can be used. See also dwg. 512-41 and chapter "COM loop cable length", page 145. Also, to get a total current consumption overview and to check if the battery capacity is enough, the tables below can be u
Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 127 filtering algorithms (see chapter "Functions / Services / Features", page 89). 18.8 Self diagnosis of internal devices The detectors perform an internal check of some vital functions and components (e.g. the IR-LED). In some modes a separate fault message will be shown in the c.i.e. The following is valid for the different type of detectors: 4352:
Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 32 Fan control and indicating panel, for four Fan control panels, each with six LEDs (On / Auto / Off / Running / Stopped / Fault) and three push buttons (On / Auto / Off). One "Reset" switch. Simple or Advanced function for a "Supply air fan" or a "Standard fan". Enhanced function for a "Smoke exhaust", "Smoke spill", "Stair pressurisation" or a "Supply air&q
Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 136 A time interval can be copied in one day field and pasted into another day field. Tuesday: Programmed the same way as the Monday. Wednesday: Programmed the same way as the Monday. Thursday: Programmed the same way as the Monday. Friday: Programmed the same way as the Monday. Saturday: Programmed the same way as the Monday. Sunday: Programmed the same way as the Monday. National
Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 119 Programmable outputs not activated. Output for routing equipment (Fire brigade tx) not activated. 17.2 Battery faults For other conventions, see chapter "Security functions", page 153. 17.2.1 FAULT: Battery The following battery check is performed: The battery charging is turned off every 30 th second. Battery voltage is checked. Battery voltage < 24.4 V generates a f
Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 121 18 Cyber sensor functions The latest generation of detectors are called "Cyber sensors". The Cyber sensor "family" consists of the following detectors: Conventional photoelectric smoke detector 4352 Conventional multi detector 4350 Analog photoelectric smoke detector 4301 Analog multi detector 4300 NOTE! NOTE! NOTE! NOTE! NOTE! NOTE! NOTE! The analog detectors 4301 and 4300 can via the address setting tool 3314 be set in
Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 12 2.12 Network / TLON ® / LonWorks ® / Echelon / Node / TLON Conn. board / Channel / Backbone net / Router / Repeater Brief explanations to the words/expressions to be found in connection with a "network". See also separate TLON Technical descrip
Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 157 shall be used to read a true value instead of a calculated current consumption. A tip: Turn off the main power source (230 V AC) and use e.g. a "clamp current meter" on one of the wires between one of the batteries and the Main board 5010, to read the true total control unit current consumption. An approx. value is displayed via menu H5/A5.
Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 158 26 S/W versions Due to continual development and improvement, different S/W versions can be found. Different S/W versions can be found on different markets. The S/W versions listed below were the valid ones when this document was written (the date of this document or date of revision). S/W for: Latest version Required version 5000 / 5001; EBL512 G3 1.1.0 1.1.0 4580; 8 zones expansion board, P.c.b. no. 9287-2B 1.0.3 1.0.2 4580; 8 zones expansion board, P.c.b. n
Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 72 13 Output programming Output programming is done in WinG3. See the WinG3 dialog box respectively. See also WinG3 help. 13.1 Type of output Some output types can be collective disabled. Some output types can when activated, be indicated by an LED. The fol
Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 156 The relation between the total current consumption in normal state (I TN ) and the backup time. One table for the built-in 28 Ah batteries and one table for the external 65 Ah batteries: NOTE! Theoretical values. Built-in 28 Ah batteries: I TN (A) Backu
Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 107 If a fire alarm type A is received, the probability of a real fire is higher than for a fire alarm type B. The alarm receiver can take different actions depending on if it is a type A or B fire alarm. 16.15.1 Fire alarm type B The output shall be programmed (via WinG3) as type "Routing equipment" and have the trigger condition "One detector alarm". The output will be activated for fire alarm from one analog addressable smoke, heat or multi 101 detector only. 16.15.2 Fire alarm
Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 24 5.3 Programmable voltage outputs (S0-S3) The 24 V DC outputs S0-S3 are supervised (monitored) 5 . Connections according to dwg 512 G3 – 23. When all connections are done a calibration has to be performed, see chapter "Calibration of supervised outputs", page 110 and the EBL512 G3 Operating Instructions MEW01163, chapter "Calibration of s
Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 11 2.2.8 Conventional zone line input / External line Input intended for one or more conventional alarm points. End-of-line device in the last alarm point on the line. 2.3 Output unit Addressable unit with programmable control outputs. Connected to a COM loop (see below). 2.4 Output / Control output Defined or programmable function. Relay output or voltage output (supervised / monitored or not), in the c.i.e. or an output
Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 4 14.3.3 Reset interlocking output (H9/C3) ________________ 87 14.3.4 Disable interlocking output (H9/C4) _______________ 87 14.3.5 Re-enable interlocking output (H9/C5) _____________ 87 14.4 Interlocking control expressions ______________________ 87 15 Fire Door Closing __________________________ 88 16 Functions / Services / Features _______________ 89 16.1 Sensor value ________________________________
Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 52 equipment requiring 24 V DC with battery backup, e.g. the 3364 unit (see page 47). It also has a "/Mains OK" output (normally low), intended to be connected to the corresponding input on the 3364 unit. A light grey metal housing (HxWxD, 288 x 400 x 95 mm). There is space for two maintenance-free sealed Lead-Acid backup batteries, 2 x 12 V, 7.5 Ah as the second power source. Batteries with higher capacity (up to 65 Ah) have to be pl
Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 29 and low voltage states cannot be reached / activated. After alarm reset (in EBL512 G3) the zone line input will return to the normal state. 6.2.2.4 Short-circuit state The short-circuit current limit 13 is exceeded, indicating short-circuit on the zone line. This no
Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 3 9.3.1 Web-servers __________________________________ 59 9.4 Other units _______________________________________ 59 9.4.1 Alert Annunciation Controllers ___________________ 59 9.4.2 External LED ________________________________ 60 9.4.3 Alarm devices (sounders, etc.) ___________________ 60 9.4.4 Door release magnets __________________________ 60 9.4.5 Boxes _________________________
Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 68 12 Programmable outputs In each control unit are four programmable voltage outputs (S0-S3) and two programmable relay outputs (R0-R1) available. 8 relays expansion boards (4581) and Input and Output expansion board (4583) with three programmable outputs (Output 0-2) can be mounted in each EBL512 G3. See chapter "Expansion boards 458x", page 26. On the COM loop
Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 95 Figure 20. An example of the smouldering smoke algorithm for an Analog smoke detector 4301. Explanations to the figure: In this example, the week average sensor value and the decision value are "10" at the "starting point", i.e. due to contamination the smouldering level has been adjusted to "24" (10+14), the pre-warning level to "32" (10+22) and the fire alarm level to "40" (
Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 98 FAULT: Loop unit xxx-xx Technical number xxxxxx 16.8 Minimum / Maximum sensor values To find out how the environment is, where an analog detector 33xx / 430x (in NORMAL mode) is mounted, the minimum and maximum sensor values can be studied. The sensor values are continuously picked up and evaluated by the control unit (c.i.e.) for each detector individually. Every value is checked if it is a new minimun or maximum value for that detector. At midnight every day a memory will be updated and th
Panasonic MEW01 351, Planning Instructions MEW01351 Revision - Fire Alarm System EBL512 G3 V1.1.x Author: Jan Pettersson Date of issue: 2011-02-11 Date of rev:
Panasonic MEW01 351, Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 20 Figure 2. The EBL512 G3 front with display ("Man-Machine- Interface"); The Fire Brigade Panel (FBP) is the upper part and the Control Panel (CP) is the lower part. The look might vary depending on the language, country, etc. (A front with texts in English is shown in the figure). The FBP is used by the fire brigade personnel to see which alarm point(s) / zone(s) having activated fire alarm and to take required operational control of the system.
Panasonic Electric Works Nordic AB MEW01351 Rev: - Planning Instructions Fire alarm system EBL512 G3, V1.1.x 47 address label on which the unit's COM loop address can be written. The Address setting tool (3314) is also used for the mode setting: NORMAL mode: Used for 3361 in system EBL512 G3. 2330 mode: Not used in system EBL512
Panasonic 4318 Smoke Alarm Specification sheet
4318 |
Panasonic 3312F Smoke Alarm Specification sheet
3312F |
Panasonic 3309 Smoke Alarm Specification sheet
3309 |
Panasonic 1735 Smoke Alarm Specification sheet
1735 |
Panasonic 3333 Smoke Alarm Specification sheet
3333 |
Panasonic 1828 Smoke Alarm Specification sheet
1828 |
Panasonic 2217 Smoke Alarm Specification sheet
2217 |
Panasonic 1548 Smoke Alarm Specification sheet
1548 |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Kompernass | SILVERCREST KH 1161 | Operating instructions manual | kompernass/silvercrest-kh-1161-8E4.pdf | 04 Jul 2022 | 50 | |
2 | Sony | HDR-XR500 | Operating manual | sony/hdr-xr500-8A7.pdf | 30 Oct 2022 | 131 | |
3 | Morphy Richards | soupmaker | Operation & user’s manual | morphy-richards/soupmaker-48I.pdf | 09 Dec 2023 | 12 | |
4 | Bell System | bell free | Installation & operation manual | bell-system/bell-free-3Z1.pdf | 31 Dec 2023 | 44 | |
5 | Daewoo | DTQ 26S1FC | Instruction manual | daewoo/dtq-26s1fc-664.pdf | 30 Mar 2023 | 27 | 0.92 Mb |
6 | Bplus Technology | MP2A | Operation & user’s manual | bplus-technology/mp2a-SKQ.pdf | 10 Feb 2024 | 16 |
UniPOS
TIP FD 3030KULLANMA TALIMATı 01-3030-06-051293GENEL TARİFFD 3030 Optik Etkili Duman Dedektörü, yangın koruma bölgesindeki herhangi bir yangın anında,duman yoğunluğunun sabit bir değerin üzerine çıkması durumunda erken uyarı vermek içindizayn edilmişlerdir. Çalışma prensibi, duman partiküllerinin optik sensör odacığına girereksensor …
FD 3030(2 pages) |
Kidde
1Thank you for purchasing a Kidde Fyrnetics alarm. Please read through our guide in full. Kidde Fyrnetics recommends for maximum protection that both ionisation and photo-elec-tric (optical) smoke alarms be installed. Ionisation sensing alarms may detect invisible fireparticles (associated with fast flaming fires) sooner than photoelectric alarms.Photoelectr …
1SF23/9HI(9 pages) |
Firex
SPECIFICATIONSModel Number: ADHElectrical Rating: 120 VAC, 60 HZ, 80mA, max, 9 volt battery back-upInterconnect Quantity: 18 alarms maximum, no more than 12 can be smokealarmsU.L. Alarm Point temperature: 58°C (135°F) fixed temperatureU.L. Maximum ambient temperature at unit: 38°C (100°F)Operating temperature: -23°C to 70°C (-10°F to 158 …
ADH(16 pages) |
BRK electronic
Description:The FCD2BN is an AC-powered plug-in CO alarm. It is microprocessor controlled for accurate andreliable operation. Meets UL2034. Single-button test/silence. Permanent CO sensor.Alarm indicatorlight: Power shines constant red, during Alarm LED flashes when CO alarm levels are detected.Also have malfunction/service mode alert. Loud, 85dB horn. 5-Yea …
First Alert SCO1BN(2 pages) |
EMS
©2018 EMS Ltd. All rights reserved. TSD115 Iss2 17/09/2018 AJMWireless RIMProgramming Guide
…
FireCell FCZ-170-111(22 pages) |
System Sensor
D100-04-00 1 I56-581-07R2151 Low ProfilePhotoelectronic Plug-in Smoke DetectorINSTALLATION AND MAINTENANCE INSTRUCTIONS 3825 Ohio Avenue, St. Charles, Illinois 601741-800-SENSOR2, FAX: 630-377-6495www.systemsensor.comBefore Installing Please thoroughly read the System Sensor manual A05-1003, Applications Guide for System Smoke Detectors, wh …
2151(4 pages) |
ABU HOSAN Air Conditioner AHR24MEBAir Conditioner Owner's manual (ABU HOSAN AHR24MEB) AHR24MEB, 14 |
Gorenje Refrigerator GDF67088Gorenje GDF67088 Manual (Doc Type: Refrigerator User manual manual) GDF67088, 16 |
Dell Docking Station WD15WD15 Quick start manual - 6CSRB5 WD15, 2 |
Panasonic Air Conditioner CS-F24DB4E5Service manual for Panasonic CS-F24DB4E5 Air Conditioner CS-F24DB4E5, 156 |
Dimplex Indoor Fireplace DFO2307PDF User Manual (@LAK987), Dimplex DFO2307 Indoor Fireplace (25.11.2023) DFO2307, 12 |
Grundig VCR GV 540 HIFIGrundig GV 540 HIFI VCR Operation & user’s manual GV 540 HIFI, 38 |
ViewSonic Monitor 17PS-2Manual: ViewSonic 17PS-2 (256G31, Upd.Wednesday 04-10-2023) 17PS-2, 81 |
Titan Safes MonsterVault 4828#2H1Q5G MonsterVault 4828: Titan Safes Owner Documentation MonsterVault 4828, 5 |
Philips Monitor 278G4#6VVZD6 278G4: Philips Monitor Owner Documentation 278G4, 44 |
Xsream Pressure Washer X-HW2565ARPressure Washer #LY3FSU X-HW2565AR, 34 |
Triton Plumbing Product ASPIRANTE#9899ZA ASPIRANTE: Triton Plumbing Product Owner Documentation ASPIRANTE, 32 |
Walkera Toy Super CPWalkera Super CP User Manual (User handbook manual), @4LPU4T Super CP, 25 |