Manualios.com

Panasonic S1DXM-M Specifications

Panasonic S1DXM-M Manual Online:

4.3, 2192 votes
Panasonic S1DXM-M User Manual
Panasonic S1DXM-M User Guide
Panasonic S1DXM-M Online Manual

Text of Panasonic S1DXM-M User Guide:

  • Panasonic S1DXM-M, Timers S1DXM-A/M Product types  S1DXM-A multi-range timer No MODE switch, Operation mode (fixed): Power ON-delay Note: 48 V DC, 100 to 110 V DC, 24 V AC and 220 to 240 V AC types are made to order. Please inquire for details. A socket line holding clip (ADX28005) is not included with the product. Please purchase separately. MULTI-RANGE ANALOG TIMER S1DXM-A/M Operating voltage Time range Timed-out 2 Form C Timed-out 4 Form C Part No. Part No. 12V DC 0.05 s to 10 min S1DXM-A2C10M-DC12V

  • Timers S1DXM-A/M  S1DXM-M multi-range timer With MODE switch, Operation mode (switchable): Power ON-delay, Power Flicker OFF start, Power Flicker ON start, Power One-shot Note: 48 V DC, 100 to 110 V DC, 24 V AC and 220 to 240 V AC types are made to order. Please inquire for details. A socket line holding clip (ADX28005) is not included with the product. Please pu

  • Timers S1DXM-A/M Specifications Notes: *1. Unspecified measuring conditions are rated operating voltage (in case of DC type, ripple rate of 5% or less), ambient temp. 20°C 68°F, and power off time 1 second. *2. Power one-shot 1 s range: +2% and 10 ms *3. When using with a transmission wave rectification, vibration resistance and shock resistance properti

  • Panasonic S1DXM-M, Timers S1DXM-A/M Operation mode and Time range setting Operation mode  S1DXM-A multi-range timer Power ON-delay operation • When power is turned on, the output contact operates after the set time. The output contact remains on until the power is turned off.  S1DXM-M multi-range timer * When the power is repeatedly turned on and off, the UP (Operation) LED may light up briefly when power is applied. This is not a malfunction. Notes: 1. The product is factory shipped with all settings on the OFF side (left). 2. Do not operate the switches with a sharp-edged object such as a knife blade. 3. The power must be turned

  • Panasonic S1DXM-M, Timers S1DXM-A/M Part names Dimensions (mm inch) Time range switch Time range switch Setting dial Operation LED (orange) Power LED (green) Setting hand Control time scale S1DXM-MS1DXM-A Operation mode switch • [RANGE] Time range switch (4 different time ranges can be switched.) • [MODE] Operation mode switch (4 different operation modes can be switched.) Power ON-delay Power Flicker OFF start Power Flicker ON start Power One-shot 10M type: 30M type: 60M type: 10H type: 1 s/10 s/1 min/10 min 3 s/30 s

  • Panasonic S1DXM-M, Options S1DXM-A/M/S1DX COMMON OPTIONS  Accessory (Unit: mm inch) • Mounting frame (for panel mounting type)  Terminal socket  Socket leaf holding clip S1DXM-A/M/S1DX COMMON OPTIONS ADX18002 (Titanium-gray) ADX18006 (Gray) ADX18007 (Black) Panel cutout dimensions Board thickness 1 to 3 mm Note: Make sure the holes area stays as right angles. 27.1 33.5 3 30 31.5 25.1 1.067 1.319 .118 1.181 1.240 .988 +0.2 0 5 3 25.2 +.008 0 .992 +0.2 0 31.6 +.008 0 1.244 *Note .197 .118 • Protective cover ADX18008 • Cap block ADX18011 • Cap for cap block ADX18004 • Socket for cap block ADX18003 28.2 34.6 10.5 1.110 1.362 .413 30.0

  • Panasonic S1DXM-M, Options S1DXM-A/M/S1DX COMMON OPTIONS  HC relay terminal sockets Name/Model No. • Terminal socket, HC 2-pin HC2-SF-K Available Not available Dimensions Terminal layout Mounting hole dimensions Applicable timers S1DX(2c) S1DXM(2c) S1DX(4c) S1DXM(4c) 6.2 .244 30 1.181 Oval hole: 2-4.2×5 .165×.197 12 .472 15 .591 40 1.575 5 .197 17.5 .689 Terminal screw M3 4 1 81214 5913 • High terminal socket, HC 1-, 2- and 4-pin HC4-HSF-K Available Available For general rails 67 2.638 53.5 2.106 30 1.181 6.2 .244 9 .35

  • Panasonic S1DXM-M, Options S1DXM-A/M/S1DX COMMON OPTIONS  HJ relay terminal sockets Name/Model No. • HJ2 terminal socket HJ2-SFD Available Not available Dimensions Terminal layout Mounting hole dimensions Applicable timers S1DX(2c) S1DXM(2c) S1DX(4c) S1DXM(4c) 1314 912 85 41 M3 .118 terminal screw 2-M4.2×5 .165×5 mounting holes 30 1.181 22 .866 59 ±1 2.323 ±.039 72 ±1 2.835 ±.039 35.4 1.394 4 .157 16.5 .650 3.4 ±0.3 .134 ±.012 6 ±0.3 .236 ±.012 41 85 912 1314 15 ±0.2 .591 ±.008 59 ±0.3 2.323 ±.012 2-M3 .1

  • Panasonic S1DXM-M, Options S1DXM-A/M/S1DX COMMON OPTIONS  Sockets • Sockets for PC board HC2-Socket for PC board: HC2-PS-K HC4-Socket for PC board: HC4-PS-K 29.4 1.157 910 13 1 5 2 6 1211 14 4 8 3 7 7.06 .278 16.55 .652 2.3 .091 7.65 .301 21.2 .835 25.5 1.004 4.06 .160 6.35 .250 .250 6.35 25.2 .992 1.27 .050 .175 .175 4.45 4.45 .175 4.45 Name/Model No. • Socket, HC 2-pin HC2-SS-K Available Not available Dimensions Mounting hole dimensions Applicable timers S1DX(2c) S1DXM(2c) S1DX(4c) S1DXM(4c) • Socket, HC 4-pin HC4-SS-K Available Available 21.2 .835 29.4 1.157 5876 9 13 10 12 14 11 12 43 7.06 .278 4.06 .160 16.55 .652 6.35 .250 6.35 .250 2.3 .091 25.2 .992

  • Panasonic S1DXM-M, Timers PRECAUTIONS IN USING S1DXM-A/M AND S1DX  Applicable standard PRECAUTIONS IN USING S1DXM-A/M AND S1DX Safety standard EN61812-1 Pollution Degree 2/Overvoltage Category II (2 Form C type) Pollution Degree 1/Overvoltage Category II (4 Form C type) EMC (EMI)EN61000-6-4 Radiation interference electric field strength Noise terminal voltage (EMS)EN61000-6-2 Static discharge immunity RF electromagnetic field immunity EFT/B immunity Surge immunity Conductivity noise immunity Power frequency magnetic field immunity Voltage dip/Instantaneous stop/Voltage fluctuation immunity EN55011 Group1 ClassA EN55011 Group1 ClassA EN61000-4-2 4 kV contact 8 kV air EN61000-4-3 10 V/m AM modulati

  • Panasonic S1DXM-M, Timers PRECAUTIONS IN USING S1DXM-A/M AND S1DX  Others 1) When setting the time, the dial should be kept within the range indicated on the dial face. The “0” marking on the dial indicates the minimum time during which the control time can be varied (it does not indicate 0 seconds). 2) Do not rotate the knob past the stopper. 3) Turn off the power before changing the DIP switch settings. Changing the DIP switch with the power on can cause breakdown. 4) When connecting the operating power supply, make sure that no leakage current ente

Related Products and Documents (Timer):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 ZyXEL Communications Wireless-11g Access Point ZyXEL G-1000 v2 Operation & user’s manual zyxel-communications/wireless-11g-access-point-zyxel-g-1000-v2-TLK.pdf 18 Aug 2023 198 6.17 Mb
2 FUTABA 6EXP Instruction manual futaba/6exp-2F1.pdf 10 Sep 2023 37 2 Mb
3 Franklin U210 Operation & user’s manual franklin/u210-3SP.pdf 04 Dec 2022 35 0.81 Mb
4 White Rodgers Comfort Plus UV200 Installation & operation manual white-rodgers/comfort-plus-uv200-6Q5.pdf 23 Jul 2023 8 0.52 Mb
5 Dell Dimension 8458P Getting started manual dell/dimension-8458p-276.pdf 06 Feb 2024 4 1.32 Mb
6 AEG 66300 K-IN Installation and operating instructions manual aeg/66300-k-in-K18.pdf 15 Nov 2022 31 0.24 Mb

Similar Resources:

  • Vimar

    Eikon

    (4 pages)
    Viale Vicenza, 14 - I 36063 Marostica VITel. +39 0424 488 600 - Fax (Italia) +39 0424 488 188 - Fax (Export) +39 0424 488 709www.vimar.euIstruzioniInstruction sheet90720515B0 03 0810VIMAR - Marostica - ItalyInterface for traditional switches 230 V~, 12-24 V~ or 12-24 V d.c. - 2 modules.Device for connecting electrical equipment of the ON-OFF type …
  • Autonics

    CTS Series

    (4 pages)
    Hounter7Ximer0Tower of load1+aspni wxfxj syxtyx031051Towerforload0IH1.Yse proper load and power for loadnot to excess SR7SKK capacity0;8ZIH Qax6 988mF max61 of solidstate output6.Ge sure not apply reverse polarity ofpower6*[hen use inductive load0Velay etc14surge absorber0Iiode4 Zaristor etc1must be connected between bothside of the load6*+aspni wxfxj syxtyx …
  • Innotech

    MT01

    (4 pages)
    © MASS ELECTRONICS Pty Ltd 2008Models:MT01 240V 4 Channel Time Switch with Optimum StartDS 11.01 August 2013 MT01MAXTime ApplicationThe MAXTime can be used in a variety of situations that require automatic on/o scheduling. Its optimum start functionality make it particularly useful for Air Conditioning applications.• Air Conditioning scheduling• …
  • Theben

    TR 611 top2 RC 24 V

    (16 pages)
    Installation and operating instructions Time switchTERMINA TR 611 top2 RC611 0 300309 280 01GBDGBF IE NLP PLCorrect connection required for smooth zero crossing switch operation (see connection diagram)!TERMINA 611 top2 RCMENUOKtheben0612 18 242,5mm20,5mm-2230-240V~50-60HzR 10a - 30T16(10)A 250V~1C1238mmExtRCLNTR 611 top2 RCmax. 100 mSeparate phases can be …
  • Jula

    406-073

    (7 pages)
    Instrukcja obsługi cyfrowego tygodniowego wyłącznika czasowego Operating Instructions for Digital Weekly Timer 406-073 SV Bruksanvisning i original NO Bruksanvisning i original PL Instrukcja obsługi w oryginale EN Operating instructions in original 06.07.2011 © Jula AB …
  • Eaton

    TSQW1CO

    (7 pages)
    Analogue time switch 7 dAnalog-Zeitschaltuhr 7 dMinuterie analogique 7 dInterruttore orario analogico 7 dInterruptor horario analógico 7 dInterruptor horário analógico 7 dAnaloge schakelklok 7 dAnalogowy zegar sterujący 7 dTSQW1CO 167392GBDF IE P NL PLService address/HotlineEaton Industries (Austria) GmbHScheydgasse 42A-1215 Wienwww.eaton.com309518TSQW1 …