Manualios.com

Harman Stove Company Accentra 2 Installation And Operating Manual

Harman Stove Company Accentra 2 Manual Online:

3.75, 2905 votes
Harman Stove Company Accentra 2 User Manual
Harman Stove Company Accentra 2 User Guide
Harman Stove Company Accentra 2 Online Manual

Text of Harman Stove Company Accentra 2 User Guide:

  • Harman Stove Company Accentra 2, SAFETY NOTICE PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW ROOM HEATER. FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH. FOR USE IN THE U.S. AND CANADA. SUITABLE FOR INSTALLATION IN MOBILE HOMES IF THIS HARMAN ACCENTRA PELLET STOVE IS NOT PROPERLY INSTALLED, A HOUSEFIRE MAY RESULT. FOR YOUR SAFETY, FOLLOW INSTALLATION DIRECTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONSAND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA. CONTACT YOUR LOCAL AUTHORITY (SUCH AS MUNICIPAL BUILDING DEPARTMENT, FIRE DEPARTMENT, FIRE PREVENTION BUREAU, E

  • Harman Stove Company Accentra 2, 2 Introduction Harman Stove Company 352 Mountain House Road Halifax, PA 17032 [email protected]@harmanstoves.com Table of Contents Automatic Operation 4 Manual Operation 6 ESP Control 8 Assembly & Installation 9 Venting 14 Maintenance 20 Trouble-Shooting 25 Specifications 26 Wiring Diagram 27 Feeder Parts 28 Parts List 29 Warranty 30 This heating appliance does not just have automatic ignition, it has total automatic temperature control. The Accentra has an input heat range from 0 to 40,000 BTU's. This patented feed system has a maximum feed rate of 5 lbs. per hour and a minumum (maintenance) feed rate of .75 lbs. per hour and then "

  • Harman Stove Company Accentra 2, 3 The Accentra pellet stove is more than just automatic ignition, it is also automatic temperature control. The automatic system will allow the fire size to be adjusted to match the heating needs and even put the fire out if necessary. If heat is needed after the fire is out, the Accentra will automatically re-ignite and adjust the fire size to match the heating need. The totally automatic room sensor mode is recommended because of its efficiency. The unit can be switched between "AUTO" and "

  • Harman Stove Company Accentra 2, 4 Starting First Fire Ignitor Switch to"AUTO" (down position) Make sure the unit is plugged into a 120 VAC, 60 HZ electrical source. The power light should be the only light lit. 1. Turn Mode Selector to "OFF". 2. Fill hopper with pellets. 1 3. Clean burn pot with scraper, if necessary. 5 4. If starting after an empty hopper, turn Feed Adjuster to "TEST" (for one 60 second cycle). 2 This will purge pellets into the auger tube and also allow you to check the motors for operation. NOTE: The auger motor will not operate with the view door or ash pan door open. 3 5. Turn Feed Adjuster to #4. 4 6. Flip the Ignitor Sw

  • Harman Stove Company Accentra 2, 5 The Accentra Pellet Stove is capable of manual operation. This also allows the opera- tor to manually control operation during an emergency (i.e. igniter failure, when using a 502H battery backup, or when using certain generators.) The unit can be switched between "AUTO" and "MANUAL" at any time during operation. Ignitor Switch to "MANUAL" Room Temperature Mode The fire will have to be lit with starting gel and a match, or started automatically, see "Automatic Opera- tion". Turn to "Manual" position when the fire is estab- lished. The difference between "AUTO" Room Tempera- ture Mode and &qu

  • Harman Stove Company Accentra 2, 6 Manual Start Up Starting First Fire Ignitor Switch to"MANUAL" (up position) Make sure the unit is plugged into a 120 VAC, 60 HZ electrical source. The power light should be the only light lit. 1. Turn FEED ADJUSTER to desired feed rate. No. 4 is good for most pellets. 4 2. Turn the MODE SELECTOR to “OFF” and then to the desired mode. This will reset control and start the combustion motor. 3. Turn the TEMPERATURE DIAL to the de- sired setting. 4. Clean burn pot with scraper if necessary. 5 5. Fill burn pot with pellets, only level with front edge. (Do Not Over Fill). 6. Add starting gel on

  • Harman Stove Company Accentra 2, 7 ESP Control Status light error messages: 1 Blink: Indicates control board self diagnostic fail- ure. This requires a manual reset*. 3 Blinks: Indicates ESP (Exhaust Sensing Probe) failure. This requires a manual reset*. 4 Blinks: Can occur only in Room Temp Mode and indicates Room Sensing Probe failed or not in- stalled. If a Room Sensing Probe is then installed, the status light will automatically reset. NOTE: Unit will not start in "AUTO" with this status error. 5 Blinks (In Igniter Auto. Mode Only): Indicates that the uni

  • Harman Stove Company Accentra 2, 8 When installing and operating your Harman Accentra Pellet Stove, respect basic safety standards. Read these instructions carefully before you attempt to install or operate the Accentra. Failure to do so may re- sult in damage to property or personal injury and may void the product warranty. Consult with your local building code agency and insurance representative before you begin your instal- lation to ensure compliance with local codes, including the need for permits and follow-up inspections. Several issues must be ad

  • Harman Stove Company Accentra 2, 9 Installation IMPORTANT NOTE: The Accentra unit is shipped bolted to the skid through two holes in the cast base plate. If these holes are not used to lag the unit to the floor these holes must be filled with the 3/8" x 1/ 2" hex head bolts provided. (See tag on bolt bag provided.) Leveling/vibration-dampening feet Skid bolt down holes/floor lag down holes Fig. 14 Fig. 15 Adjustment of the rubber pad leveling feet The Accentra is provided with 4 rubber pad feet. These feet will raise the bottom ed

  • Harman Stove Company Accentra 2, 10 When installing the Accentra in a mobile home several requirements must be followed: 1. The unit must be bolted to the floor. This can be done with 1/4" lag screws throught the 2 holes in the base plate shown in Fig. 16 2. The unit must also be connected for the out- side air. See page 14. 3. Floor protection and clearances must be fol- lowed as shown on page 9. 4. Unit must be grounded to the metal frame of the mobile home. CAUTION: This appliance must be vented to the outside. Due to high temperatures, the Accentra should be placed out of traffic and away from furniture and draperies. Children and adults should be alerted to the haz- ards of high surface temperatures and

  • Harman Stove Company Accentra 2, 11 These units are pre-tested at the factory with exactly 120 Volts A.C., 60 Hz. They are checked and adjusted for firebox tightness, gasket leakage, motor operation and ignitor operation. The Accentra is then factory set at a high adjustment. NOTE: Low draft adjustment may be required. The factory low draft setting may not be correct for the units permanent installation conditions. The control board on the Accentra is equipped with a low draft adjustment port. Located on the control face just to the left of the ignitor light. See Figure 17. This voltage adjustment is provided to allow the unit to be adjusted for the household voltage where the unit is going to be

  • Harman Stove Company Accentra 2, 12 The room sensor is a small temperature sen- sor on the end of a 60" gray wire. This sensor is installed much like a standard wall thermostat. Be- cause it is so small, it can be hidden along the trim of a doorway or even up the leg of a coffee table. There is a remote room sensor port on the rear of the unit for easy external connection. Use standard 18-2 thermostat wire to extend the distance to the desired location (100' maximum). The room sen- sor should be installed in the location where you want to control the temperature. NOTE: Distances of more

  • 13 Venting A combustion blower is used to extract the com- bustion gases from the firebox. This causes a nega- tive pressure in the firebox and a positive pressure in the venting system as shown in fig. 22. The longer the vent pipe and more elbows used in the system, the greater the flow resistance. Because of these facts we recommend using as few elbows as pos- sible and 15 feet o

  • Harman Stove Company Accentra 2, 14 #1 Preferred method This method provides excellent venting for nor- mal operation and allows the stove to be installed closest to the wall. Two and a half inches from the wall is safe; however, three inches allows better access to remove the rear panel. The vertical por- tion of the vent should be three to five feet high. This vertical section will provide natural draft in the event of a power failure. Note: Do not place joints within wall pass-throughs. Fig.25 Fig.26 Venting KEEP COMBUSTIBLES (SUCH AS GRASS, LEAVES, ETC.) AT LEAST 3 FEET AWAY FROM THE FLUE OUTLET ON THE OUTSIDE OF THE

  • Harman Stove Company Accentra 2, 15 This method provides excellent venting for nor- mal operation. This method also provides natural draft in the event of a power failure. If the chimney condition is questionable you may want to install a liner as in method #7. Fig.27 Venting Fig.28 This method provides excellent venting for nor- mal operation. This method also provides natural draft in the event of a power failure. The damper area must be sealed with a steel plate or fiberglass. A cap should be installed on the chimney to keep out rain. If the chimney condition is questionable you may want to install a liner all the way to the top as in Method

  • 16 This method provides excellent venting for nor- mal operation. This method also provides natural draft in the event of a power failure. In Canada and some places in the US it is re- quired that the vent pipe extend all the way to the top of the chimney. In this method a cap should also be installed on the chimney to keep out rain. Be sure to use ap- proved pellet vent pipe fittings.

  • Harman Stove Company Accentra 2, 17 Min. above ground level 18" Minimum flue vent configuration It is recommended that outside air be installed with this venting configuration to reduce smoke and creosote smell in the room in the event of power failure. #8 Installing through the ceiling vent Through the ceiling vent, follow PLvent manufacturers recommendations when using wall and ceiling pass through. Note: Do not place joints within wall pass-throughs. PL vent manufacturer's firestop spacer and support No insulation o

  • Harman Stove Company Accentra 2, 18 Venting Requirements for Terminating the Venting WARNING: Venting terminals must not be re- cessed into a wall or siding. NOTE: Only PL vent pipe wall pass-throughs and fire stops should be used when venting through combustible materials. NOTE: Always take into consideration the ef- fect the prevailing wind direction or other wind cur- rents will cause with flyash and /or smoke when plac- ing the termination. In addition, the following must be observed: A. The clearance above grade must be a mini- mum of 18". 1 B. The clearance to a window or door that may be opened must be a minimum of 48" to the side and 48" b

  • 19 Inspect the hopper lid sponge gasket. It is important to maintain a good hopper lid seal. Do not allow pellets or sawdust to remain on the hopper lip after filling. Control door finger hole Draft Meter hex plug HI-LO Distribution blower speed range switch Maintenance - Cleaning Glass on View Door The unit should be out and cool to clean the door glass. It may not always be possible to all

  • Harman Stove Company Accentra 2, 20 1. Remove the two heat exchanger covers. See Fig. 35. These covers are made of cast iron and are held into place with a swing latch in the upper right and left corners. See Fig 36. Swing the latch upward far enough to release the top edge of the heat exchanger cover. Tilt the cover forward approximately 2" and lift it upward about 1" to release the bottom edge. The cover can now be taken completely out through the upper door opening. Repeat the process with the second heat exchanger cover. Maintenance - Cleaning Heat Exchanger channel cover latch Fig. 36 Fig. 35 Cleaning Internal Components Feeder Chamb

  • Harman Stove Company Accentra 2, 21 Maintenance - Cleaning Combustion intake assembly latch (Cleaning Internal Components Cont'd) 2. Remove the combustion intake assembly. See Fig. 35. The combustion intake assembly is held into place with two swing latches. See Fig. 37. Swing each latch until it hangs down away from the retainer stud. Now the assembly can be taken out by tilting the right side outward first through the lower door opening. 3. The units interior is now ready to clean. Use the scraper provided to clean the heat exchanger surfaces. A wire brush or short bristled brush is an excellent cleaning tool.

  • Harman Stove Company Accentra 2, 22 Burn Pot Cleaning and Maintenance 1. Scrape the top holed surface and sides of the burn pot down to auger tube.(Fig 39) It is not necessary to completely remove all material from the burn pot. The excess will be pushed out during the next use. 2. Loosen the (2) wing thumb screws on the lower front angle of the burn pot. (Fig. 40) 3. Lift off the clean-out cover (Fig.40) to open the bottom clean-out chamber. (Fig.41) 4. Clean ash buildup from inside the chamber while cover is off. Use the scraper to tap on the top front edge of the burn pot. This will help

  • The Combustion Motor Fuse is a thermal overload one-time fuse link within the motor windings. Should the distri- bution motor fail with the unit operating over 80%, this fuse will protect the other components by melting off at a set tempera- ture. With the fuse blown, the combustion motor will stop.In turn, the feeder motor will not operate and the

  • Harman Stove Company Accentra 2, 24 FEEDER DOES NOT FEED 1. No pellets in hopper. 2. Firebox draft may be too low for low draft pres- sure switch in feeder circuit to operate. Check for closed doors, loose or missing gasket on doors or hopper lid, faulty pressure switch. 3. Feed motor will not run until ESP senses 165 deg. F. Maybe you did not put enough pellets in the burn pot before lighting the fire. 4. Something is restricting flow in the hopper or causing the slide plate to stick. 5. Feed motor has failed. PARTIALLY BURNED PELLETS 1. Feed rate too high. 2. Draft too low. (Check burn pot clean out slide and

  • 25 Specifications Weight 350 lbs. Blower 150 cfm Hopper Capacity 50 lbs. Fuel Wood Pellets Outside Air Size 2 3/8 inches Fuse Rating 5 amp BTU Range 0 to 40,000 Feed Rate .75 lbs./hr. on minimum(on maintenance) 5 lbs./ hr. on maximum Flue Size 3 inch Pellet Vent Pipe Maximum Wattage 440 Watts (Start cycle and test) Start Cycle Wattage 340 Watts Normal Run Wattage 255 Watts Evaluation not

  • Harman Stove Company Accentra 2, 27 Accentra Feeder Parts Feeder Body 1-10-00910W Slider Plate 1-10-08037 5/16 x 18 Wing Nut 3-30-8131181 Cover 2-00-247217 Gasket 3-44-247218 Pusher Arm Weldment 1-10-247220 Gear Motor Fan Blade 3-20-08791 Small Sprocket 3-50-08762 FHN 1/4-20 3-30-80252013 Tensioner 3/4 3-31-00075 HCS 1/4-20 x 1 1/4 3-30-1252012513 Cam Block 3-00-00153 Chain Assembly 3-50-08763 Auger 3-50-00365 Auger Retainer 2-00-04035 HCS 3/8-16 x 1-1/4 3-30-1371612513 HCS 1/4-20 x 1 Grade 8 3-30-1252010014 SHCS 1/4-20 x 3/4 3-30-3025200752 HCS 5/16-18 x 1-1/4 3-30-1311812513 Motor Mount Weldment 1-10-06603 HWH TCS 10-24 x 3/4 Black 3-30-110240753(4) Rubber Grommet 3-31-960026(

  • Harman Stove Company Accentra 2, 28 See page 27 for Feeder Part Numbers Accentra Parts List Description Part Number Hopper Lid Gasket 3-44-247101 Ignitor Element Assembly 1-10-06620 Wiring Harness 3-20-08727 Burn Pot Weldment 1-10-08736 Right Feeder Shield w/sound proof 1-10-247142 Left Feeder Shield w/sound proof 1-10-247141 Heat Exchanger Cover (2) 3-00-247105 Arrow Scraper 2-00-773850 Flame Guide 3-00-08534 Gear Motor 3-20-08752 Thermister Probe 3-20-00744 Room Sensor 3-20-00906 Circuit Board G4220G V5.0 3-20-04220 Feeder Switch Jumper 3-20-08750 3" White CCW

  • Harman Stove Company Accentra 2, 29 Harman Gold Warranty HARMAN GOLD WARRANTY 6 YEAR TRANSFERABLE LIMITED WARRANTY (Residential) 1 YEAR LIMITED WARRANTY (Commercial) Harman Stove Company warrants its products to be free from defects in material or workmanship, in normal use and service, for a period of 6 years from the date of sales invoice and for mechanical and electrical failures, in normal use and service, for a period of 3 years from the date of sales invoice. If defective in material or workmanship, during the warranty period, Harman Stove Company will, at its option, repair or replace the product as

Related Products and Documents (Cooktop):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Inter-m PB-9207A Specification inter-m/pb-9207a-AQC.pdf 18 Feb 2024 1
2 Sanyo FX-32 Instruction manual sanyo/fx-32-82Q.pdf 11 Sep 2023 16
3 Saso SASO-SH10 Installation manual saso/saso-sh10-78G.pdf 25 Mar 2024 2
4 Mitsubishi DX-TL910U Setup instructions mitsubishi/dx-tl910u-989.pdf 17 Aug 2023 11
5 PDi PDI-P20LCD Operation & user’s manual pdi/pdi-p20lcd-462.pdf 23 Sep 2022 24
6 Dukane LB77H Operation & user’s manual dukane/lb77h-G67.pdf 27 Mar 2024 20 0.7 Mb

Similar Resources:

  • KitchenAid

    KIRS608BSS

    (24 pages)
    THANK YOU for purchasing this high-quality product. If you should experience a problem not covered in TROUBLESHOOTING, please visit our website at www.kitchenaid.com for additional information. If you still need assistance, call us at 1-800-422-1230.You will need your model and serial number, located on the oven frame behind the top right side of the oven do …
  • Frigidaire

    FPIF3093LF

    (44 pages)
    All about theUse & Careof yourTABLE OF CONTENTSwww.frigidaire.com USA 1-800-944-9044 www.frigidaire.ca Canada 1-800-265-8352Electric Range withInduction Cooktop316902219 (Jul 2010)Important Safety Instructions ........................... 3-6Features at a Glance ......................................... 7Before Setting Oven Controls .......... …
  • Maytag

    MIT8795BS00

    (24 pages)
    INSTALLATIONINSTRUCTIONSFREESTANDINGELECTRICRANGE WITH DOUBLEOVENSINSTRUCTIONSD'INSTALLATIONPOURCUISINIEREe=ELECTRIQUEAUTOPORTANTEAVEC FOURSDOUBLESTableofContentsRANGE SAFETY ............................................................................. 1INSTALLATION REQUIREMENTS ................................................ 2Tools and Parts.......... …
  • KitchenAid

    KICU500X

    (1 pages)
    33¹⁄₁₆" (84.0 cm) on 36" (91.4 cm) modelsB. Combustible area above countertop (shown by dashed box above)C. 30" (76.2 cm) minimum clearance between top of cooktop platform and bottom of uncovered wood or metal cabinet (24" [61 cm] minimum clearance if bottom of wood or metal cabinet is covered by not less than ¹⁄₄" [0.6 c …
  • Samsung

    NZ30K7880UG

    (36 pages)
    Electric CooktopInstallation manualNZ30K7880**/NZ36K7880**Induction Install_NZ30K7880U_NZ36K7880U_DG68-00827A-05_EN+MES+CFR.indb 1 2018-07-31  4:10:07 …
  • Sears

    61011

    (44 pages)
    SEARSGASRANGEOWNER'SMANUALModel Numbers:61011 7229661018 7229861061 7275161111 7275561118 7275871061 7517171068 7518171161 7518871168 7527171351 7527571358 7527671661 7527871665 7528171668 75291_71751 7529571758 7529672291 7529872295Safety InstructionsAnti-Tip Device 2, 3, 3I, 39Important Safety lnstr_ctions 2-6Care & MaintenanceBeforeYou Call for S …

Comments, Questions and Opinions: