Manualios.com

SPT WA-9061H Instructions Manual

SPT WA-9061H Manual Online:

4, 1046 votes
SPT WA-9061H User Manual
SPT WA-9061H User Guide
SPT WA-9061H Online Manual

Text of SPT WA-9061H User Guide:

  • 1 PORTABLE AIR CONDITIONER WITH HEATER WA-9061H: 9,000 BTU WA-1061H: 10,000BTU ☆ Read and retain these instructions for future reference www.sylvane.com 1-800-934-9194www.sylvane.com 1-800-934-9194

  • SPT WA-9061H, 2 SPECIFICATION · Model no. WA-9061H WA-1061H Cooling capacity 9000 BTU/hr 2637 W 10000 BTU/hr 2930 W Heating capacity 8500 BTU/hr 2491 watts 9500 BTU/hr 2783 watts EER 9.38 9.35 Power/Ampere consumption – Cooling* 960W / 8.29 A 1070W / 8.7 A Power/Ampere consumption – Heating* 840W / 7.75 A 950W / 8.18 A Air volume (max. speed) 375m 3 /h 375m 3 /h Humidity removal capacity 1 L/hr 1 L/hr Power supply 110~120V/50Hz/1phase Compressor rotary Recommended room size 250 sq.ft. 300 sq.ft. Refrigerant R410A Fan speed 2 Timer 1~ 12 hours Thermostat Cooling: 64~90°F (18~32°C) Heating: 45~77°F (7~25°C) Operating temperature 45 ~ 95°F Exhau

  • SPT WA-9061H, 3 BEFORE USE GENERAL SAFETY • Only use in the upright position on a flat level surface and at least 14in. from any walls or objects (fig 1 & 4). • Do not place any objects on the unit or block the air inlet / outlet (fig. 2). • Closely supervise children and pets when unit is in use. ELECTRICAL SAFETY • For indoor household use only. • Switch off and unplug when not in use. • Do not use in humid or wet environments. (fig 3) • Do not pull the UNIT by the cord. • IF THE SUPPLY CORD IS DAMAGED, TO AVOID HAZARD, IT MUST BE REPLACED BY AN ELECTRICIAN OR SIMILARLY QUALIFIED PERSON.

  • SPT WA-9061H, 4 PARTS Front Back 1. Display window 2. Control panel 3. Air outlet 4. Carrying handle 5. Caster 6. Cord storage 7. Air filter 8. Air inlet 9. Exhaust air outlet 10. Air inlet 11. Water stopper/drainage Accessories FIG.7 13. Exhaust hose 14. Slider kit adapter – connects exhaust hose to slider kit. 15. Plastic slider kit – piece 1 of 2 16. Plastic slider kit – piece 2 of 2 17. Drain tube 18. Active carbon filter 19. Remote FIG.6 FIG.5 www.sylvane.com 1-800-934-9194www.sylvane.com 1-800-934-91

  • SPT WA-9061H, 5 INSTALLATION The unit is a portable air conditioner that may be moved from room to room. 1. Installing the plastic slider kit. FIG.8  Extend both ends of the exhaust hose by few inches.  Connect hose to the back of unit by turning clockwise – do not over tighten.  Connect adapter piece to hose by turning clockwise (with opening end facing you).  Determine how many sections of the slider kit your window requires.  Place slider kit inside the window frame and adjust height accordingly. Once set, insert the small screw through side opening to secure.  Align and insert adapter piece to

  • SPT WA-9061H, 6 Carbon Filter Installation 1. Remove filter frame from unit. 2. Remove the filter fixer from the filter frame. 3. Remove active carbon filter from plastic bag. 4. Insert active carbon filter to filter frame. 5. Replace filter fixer to frame. The active carbon filter is now held in between the filter frame and filter fixer. 6. Replace filter frame to unit. www.sylvane.com 1-800-934-9194www.sylvane.com 1-800-934-9194

  • SPT WA-9061H, 7 OPERATION Control panel 1. Mode (function) select button 2. Timer button 3. “Water Full” indicator 4. Sleep button 5. Fan speed button 6. Low fan speed indicator 7. High fan speed indicator 8. Receiver for remote control 9. Sleep operation indicator 10. “Temperature down” button 11. ON/OFF (power) button 12. “Temperature up” button 13. Timer operation indicator 14. Compressor operation indicator 15. Heat mode indicator 16. Fan mode indicator 17. Cooling mode indicator 18. Auto mode indicator Turning ON/OFF 1. Press ON/OFF button and unit will start automatically. If ambient temperature is:

  • SPT WA-9061H, 8 Setting fan speed 1. Press SPEED button to choose the desired fan speed, high or low. The corresponding indicator (HI or LOW) will illuminate. 2. If the unit is operating in AUTO mode, the SPEED button is invalid. Unit will automatically choose the fan speed based on the ambient temperature. Setting timer 1. If unit is in operation, pressing the TIMER button will set the operating hours (from 1 to 12 hours). Once the set time has been reached, unit will turn off automatically. Timer indicator wil

  • SPT WA-9061H, 9 Remote control All functions can also be performed with the supplied remote control. The remote control requires two (2) AAA batteries. Directing air flow Manually adjust the louvers left & right or up & down to direct air flow. FIG. 17 NOTICE !  To prolong the life of the compressor, after powering off the unit, please wait at least 3 minutes before turning it back on.  When operating in COOL mode, the cooling system will switch off when ambient temperature falls below set temperature. The fan, however, will continue to run. Once ambient temperature rises above the se

  • SPT WA-9061H, 10 DRAINAGE During the cooling process, some water will be extracted from the air into the unit. If the reservoir is full, both of the compressor (cooling) and motor (fan) will stop and unit will emit a Buzz (press any button to stop the buzz); the Water Full indicator will also be flashing. Before cooling can resume, empty the water tank: 1. Turn off the air conditioner and avoid moving it when full. 2. Position a container (a water tray for example) underneath the drain spout. 3. Remove the drain knob & rubber plug and allow water to drain out. 4.

  • SPT WA-9061H, 11 MAINTENANCE Always unplug the air conditioner from power source before cleaning. Clean regularly to maximize the efficiency of the air conditioner. Cleaning the housing  Use a soft, damp cloth to wipe the body clean.  Never use aggressive chemicals, gasoline, detergents, chemically treated cloths, or other cleansing solutions. These products may blemish the cabinet. Cleaning the filter  Use a vacuum cleaner or tap the filter lightly to first remove any loose particles, then rinse thoroughly under running water (no hotter than 104°F/40�

  • 12 Your Guarantee If this product is found to be faulty as a result of faulty materials or workmanship within one year from date of purchase, it will be repaired free of charge. This guarantee is subject to the following terms: • Sunpentown must be notified of the fault. • Proof of purchase must be presented to Sunpentown’s nominated r

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Craftsman 315.101270 Owner's manual craftsman/315-101270-247.pdf 04 Sep 2023 12 0.62 Mb
2 LG LG-P768g Operation & user’s manual lg/lg-p768g-IF7.pdf 01 Dec 2022 98
3 Sony TDG-BR100 Instructions sony/tdg-br100-NU6.pdf 26 Oct 2023 2 0.88 Mb
4 Craftsman 944.364781 Owner's manual craftsman/944364781-941.pdf 16 Feb 2023 16
5 Black & Decker 90510266 Instruction manual black-decker/90510266-615.pdf 02 Mar 2024 5 0.25 Mb
6 Martin MAC 250+ Operation & user’s manual martin/mac-250-2B8.pdf 16 Nov 2023 30

Similar Resources:

  • Frigidaire

    FRP12ETT2R

    (6 pages)
    frigidaire.comSignature FeaturesAir Conditioner /  Electric HeaterPerformance CoolElectric HeaterBTUs 12,000 / 11,80010,200 / 8,300Product DimensionsHeight 16"Width 42"Depth 13-13/16"More Easy-To-Use FeaturesComfort Control DesignSimple controls allow guests to customize their settings, while quiet, uniform air movement keeps ro …
  • Panasonic

    CWXC100HU

    (35 pages)
    INSTALLATION AND OPERATING INSTRUCTIONSRoom Air ConditionerModels: CW-XC100HU, CW-XC120HUPlease read these operating instructions thoroughlybefore using your air conditioner and keep for future reference.For U.S. customers:For assistance, please call: 1-800-211-PANA(7262) or Register your product at : http://www.panasonic.com/registerCW382820391KR …
  • Johnson Controls

    13

    (4 pages)
    126114-UUM-M-0409USER’S INFORMATION MANUALOUTDOOR SPLIT-SYSTEM AIR CONDITIONERMODELS: 13, 14 & 14.5 SEER SERIES - 1 & 3 PHASE1 TO 5 TONSLISTEDISO 9001Certified QualityManagement SystemThis high efficiency air conditioning system has been precision engi-neered, manufactured of high quality materials, and passed many rigor-ous tests and inspections t …
  • Panasonic

    CS-KE18NKU

    (26 pages)
    This air conditioner uses the refrigerant R410A.Split System Air ConditionerModel No.1006 Kadoma, Kadoma City, Osaka, Japan85264181212002Indoor UnitsCS-KE18NKUCS-KE24NKUOutdoor UnitsCU-KE18NKUCU-KE24NKUOperating InstructionsBefore operating the unit, read these operating instructions thoroughly and keep them for future reference.CV6233187235 …
  • Frigidaire

    FAC082M7A1

    (12 pages)
    PRODUCT NO. BASE MODEL NO. SERIES VOLTS BTU-COOLINGFAC082M7A1 FAC082M7A Compact 115 8000 BTUMARKETUSAPublication No.5995382966021217-EN/SERVICE /KC345ROOM AIR CONDITIONERModel No.FAC082M7A1©2002 Electrolux Home Products, Inc.All rights reservedFACTORY PARTS CATALOGROOM AIR CONDITIONERWIRING DIAGRAM - # 309107703OWNER’S GUIDE - # 309000823ENERGY GUIDE - # …
  • Haier

    1UH071N1ERG

    (24 pages)
    1UH071N1ERG1UH090N1ERG1UH105N1ERGOriginal instructions1UH125P1ERG1UH140P1ERG1UH160P1ERG1UH125P1ERK1UH140P1ERKNo. 0150518634 H1UH200W1ERK1UH250W1ERKINSTALLATION MANUALSPLIT SYSTEM AIR CONDITIONERKeep this operation manual for future reference.4467910131516171923ContentsDefinitionsSafety considerationsBefore installationSelecting installation sitePrecautions …

Comments, Questions and Opinions: