  • x CAUTION: Do not stop operation by switching OFF electromagnetic contactors on the primary or secondary sides of the inverter. When there has been a sudden power failure while an operation instruction is active, then the unit may restart operation automatically after the power failure has ended. If there is a possibility that such an occurrence may harm humans, then install an electro

  • Hitachi SJ2002 Series, SJ2002 Inverter Configuring Drive Parameters 3–37 Software Lock Mode The software lock function keeps personnel from accidentally changing parameters in the inverter memory. Use B031 to select from various protection levels. The table below lists all combinations of B031 option codes and the ON/OFF state of the [SFT] input. Each Check ✔ or Ex ✘ indicates whether the corresponding parameter(s) can be edited. The Standard Parameters column below lists Low and High level access for some lock modes. These refer to the parameter tables throughout this chapter, each of which

  • Hitachi SJ2002 Series, SJ2002 Inverter Getting Started 1–3 Operator Interface Options The SJ2002 inverter has a removable keypad, as shown to the right (part no. OPE–SRmini). This allows the keypad to operate the inverter remotely, as shown (below, left). A cable (part no. ICS–1 or ICS–3, 1m or 3m) connects the modular connectors of the keypad and inverter. Hitachi provides a panel mount keypad kit (below, right). It includes the mounting flange, gasket, keypad, and other hardware. You can mount the keypad with the potentiometer for a NEMA1 rated installation. The kit also provides for removing the potentiometer knob to meet NEMA 4X requirements, a

  • Hitachi SJ2002 Series, Using Intelligent Output Terminals Operations and Monitoring 4–44 Alarm Signal The inverter alarm signal is active when a fault has occurred and it is in the Trip Mode (refer to the diagram at right). When the fault is cleared the alarm signal becomes inactive. We must make a distinction between the alarm signal AL and the alarm relay contacts [AL0], [AL1] and [AL2]. The signal AL is a logic function, which you can assign to the open collec- tor output terminals [11] or [12] or the relay outputs. The most common (and default) use of the relay is for AL, thus the labeling of its terminals. Use an open collector output (terminal [11

  • Hitachi SJ2002 Series, “C” Group: Intelligent Terminal Functions Configuring Drive Parameters 3–48 Input Function Summary Table – This table shows all twenty-four intelligent input functions at a glance. Detailed descriptions of these functions, related parameters and settings, and example wiring diagrams are in “ Using Intelligent Input Terminals” on page 4–9. Input Function Summary Table Option Code Terminal Symbol Function Name Description 00 FW Forward Run/Stop ON Inverter is in Run Mode, motor runs forward OFF Inverter is in Stop Mode, motor stops 01 RV Reverse Run/Stop ON Inverter is in Run Mode, motor runs reverse OFF Inverter is in Stop Mode, motor stops

  • Parameter Settings for Keypad Entry Appendix C C–6 A295 Acc1 to Acc2 frequency transi- tion point, 2nd motor 0.0 0.0 A096 Dec1 to Dec2 frequency transi- tion point 0.0 0.0 A296 Dec1 to Dec2 frequency transi- tion point, 2nd motor 0.0 0.0 A097 Acceleration curve selection 00 00 A098 Deceleration curve selection 00 00 A101 [OI]–[L] input active range start frequency 0.0 0.0 A102 [O

  • Hitachi SJ2002 Series, Orientation to Inverter Features Inverter Mounting and Installation 2–2 Orientation to Inverter Features Unpacking and Inspection Please take a few moments to unpack your new SJ2002 inverter and perform these steps: 1. Look for any damage that may have occurred during shipping. 2. Verify the contents of the box include: a. One SJ200 2 inverter b. One Instruction Manual c. One SJ200 2 Quick Reference Guide 3. Inspect the specifications label on the side of the inverter. Make sure it matches the product part numb

  • Hitachi SJ2002 Series, SJ2002 Inverter Getting Started 1–7 SJ2002 Inverter Specifications, continued... Item 200V Class Specifications, continued SJ200 2 inverters, 200V models EU types 015NFEF2 015NFE2 022NFEF2 022NFE2 ——— USA type 015NFU2 022NFU2 037LFU2 055LFU2 075LFU2 Applicable motor size *2 kW 1.5 2.2 3.7 5.5 7.5 HP 2 3 5 7.5 10 Rated capacity (kVA) 230V 3.1 4.3 6.9 9.5 12.7 240V 3.3 4.5 7.2 9.9 13.3 Rated input voltage 1-phase: 200 to 240V ±10%, 50/60 Hz ±5%, 3-phase: 200 to 240V ±10%, 50/60 Hz ±5%, (037LFU, 055LFU, 075LFU 3-phase only) Integrated EMC filte

  • Hitachi SJ2002 Series, SJ2002 Inverter Configuring Drive Parameters 3–19 A242 Manual torque boost value, 2nd motor Can boost starting torque between 0 and 20% above normal V/f curve, range is 0.0 to 20.0% ✔ ✔ 0.0 0.0 % 2VBst V 0000.0% A043 Manual torque boost frequency adjustment Sets the frequency of the V/f breakpoint A in graph (top of previous page) for torque boost, range is 0.0 to 50.0% ✔ ✔ 3.0 3.0 % M-Bst F 0003.0% A243 Manual torque boost frequency adjustment, 2nd motor Sets the frequency of the V/f breakpoint A in graph (top of previous page

  • Hitachi SJ2002 Series, Dynamic Braking Motor Control Accessories 5–8 Selecting Braking Resistors for Internal Braking Units You can add one or more resistors to your inverter configuration to increase braking torque performance. The tables below lists the resistor types for inverter models with internal braking units. Tables for inverters with external braking units are on the next two pages. • Total Ohms – lists the resistance value of the resistor or, if using multiple resistors, their combined resistance • Total Watts – lists the power dissipation of the resistor or, if using multiple resi

  • SJ2002 Inverter Troubleshooting and Maintenance 6–5 Monitoring Trip Events, History, & Conditions Fault Detection and Clearing The microprocessor in the inverter detects a variety of fault conditions and captures the event, record- ing it in a history table. The inverter output turns OFF, or “trips” similar to the way a circuit breaker trips due to an over-current condition. Most faul

  • Hitachi SJ2002 Series, Troubleshooting Troubleshooting and Maintenance 6–4 The motor speed will not reach the target frequency (desired speed). • If using the analog input, is the current or voltage at [O] or [OI]? • Check the wiring. • Check the potentiometer or signal generating device. • Is the load too heavy? • Reduce the load. • Heavy loads activate the overload restriction feature (reduces output as needed). • Is the inverter internally limiting the output frequency? • Check max frequency setting (A004) • Check frequency upper limit setting (A061) The rotation is unstable. • Is the loa

  • Hitachi SJ2002 Series, SJ2002 Inverter Appendix B B–17 Exception Response: When sending a query (excluding a broadcasting query) to an inverter, the master always requests a response from the inverter. Usually, the inverter returns a response according to the query. However, when finding an error in the query, the inverter returns an excep- tion response. The exception response consists of the fields shown below. The content of each field is explained below. The function code of the exception response is the sum of the function code of the query and 80h. The exception code indicates the factor of the exception response. Field Configuration Slave address Function code Exception code CRC–16 Function Cod

  • Hitachi SJ2002 Series, Parameter Settings for Keypad Entry Appendix C C–10 C042 Frequency arrival setting for acceleration 0.0 0.0 C043 Arrival frequency setting for deceleration 0.0 0.0 C044 PID deviation level setting 3.0 3.0 C052 PID FBV function high limit 100.0 100.0 C053 PID FBV function low limit 0.0 0.0 C071 Communication speed selection 06 04 C072 Node allocation 1. 1. C074 Communication parity selection 00 00 C075 Communication stop bit selection 1 1 C076 Communication error select 02 02 C077 Communication erorr time-out 0.00 0.00 C078 Communication wait time 0. 0. C081 O input span calibration 100.0 100.0 C082 OI input span calibration

  • Hitachi SJ2002 Series, ModBus Data Listing Appendix B B–26 The following table lists the holding registers for the “A” Group Standard Functions. Holding Registers for “A” Group Standard Functions Func. Code Name R/W Description Network Data Register Range Res. hex dec. A001 Frequency source setting R/W Five options; select codes: 00 .. Keypad potentiometer 01 .. Control terminal 02 .. Function F001 setting 03 .. ModBus network input 10 .. Calculate function output 1019h 04121 0 to 3, 10 — A002 Run command source setting R/W Three o

  • Glossary and Bibliography In This Appendix.... page — Glossary .......................................................... 2 — Bibliography .................................................... 8 A

  • Hitachi SJ2002 Series, SJ2002 Inverter Operations and Monitoring 4–59 Configuring the Inverter for Multiple Motors Simultaneous Connections For some applications, you may need to connect two or more motors (wired in parallel) to a single inverter’s output. For example, this is common in conveyor applications where two separate conveyors need to have approximately the same speed. The use of two motors may be less expensive than making the mechanical link for one motor to drive multiple conveyors. Some of the characteristics of using multiple motors with one drive are: • Use

  • Hitachi SJ2002 Series, SJ2002 Inverter Appendix B B–15 Write in Coils [0Fh]: This function writes data in consecutive coils. An example follows: • Change the state of intelligent input terminal [1] to [6] of an inverter having a slave address “5.” • This example assumes the intelligent input terminals have terminal states listed below. Item Data Intelligent input terminal [1] [2] [3] [4] [5] [6] Coil number 7 8 9 10 11 12 Terminal status ON ON ON OFF ON OFF Query: Note 1: Broadcasting is disabled. Note 2: The change data is a set of high-order data

  • Hitachi SJ2002 Series, ModBus Data Listing Appendix B B–32 A103 [OI]–[L] input active range start current R/W The starting point for the current input range. Range is 0. to 100.% 1083h 04227 0 to 100 1 % A104 [OI]–[L] input active range end current R/W The ending point for the current input range. Range is 0. to 100.% 1084h 04228 0 to 100 1 % A105 [OI]–[L] input start frequency enable R/W Two options: 00 .. Use A101 start value 01 .. Use 0Hz 1085h 04229 0, 1 — A141 A input select for calcu- late function R/W Five options: 00 .. Digital operator 01 .. Keypad potentiometer 02 .. [O] input 03 .. [OI] input 04 .. Network vari

  • Hitachi SJ2002 Series, ii General Precautions - Read These First! WARNING: This equipment should be installed, adjusted, and serviced by qualified electrical maintenance personnel familiar with the construction and operation of the equipment and the hazards involved. Failure to observe this precaution could result in bodily injury. WARNING: The user is responsible for ensuring that all driven machinery, drive train mechanism not supplied by Hitachi Industrial Equipment Systems Co., Ltd., and process line material are capable of safe operation at an applied frequency of 150% of the maximum selected frequency range to the AC motor. Failure to do so can result in

More Instructions:

DOWNLOAD

Related Products and Documents (Inverter):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Sennheiser Evolution E 602-II Technical data sennheiser/evolution-e-602-ii-NUY.pdf 09 Jun 2023 2 0.55 Mb
2 Electrolux TG 10010 Operation & user’s manual electrolux/tg-10010-DNI.pdf 12 Oct 2022 23 0.31 Mb
3 Boss Audio Systems BV9967BI Operation & user’s manual boss-audio-systems/bv9967bi-J4D.pdf 22 Nov 2023 10 1.15 Mb
4 Echo PB-251 Service data echo/pb-251-265.pdf 09 Sep 2022 8 0.34 Mb
5 YURAKU YUR.VISION YV19WB2 Brochure yuraku/yur-vision-yv19wb2-193.pdf 02 Sep 2023 2 0.43 Mb
6 Aiwa XR-EM200 Operating instructions manual aiwa/xr-em200-K2E.pdf 25 Jun 2023 19 0.31 Mb

Similar Resources:

  • Simco

    ECM 30 Series

    (98 pages)
    SIMCO (Nederland) B.V. Postbus 71 NL-7240 AB Lochem Telefoon + 31-(0)573-288333 Telefax + 31-(0)573-257319 E-mail [email protected] Internet http://www.simco.nl Traderegister Apeldoorn No. 08046136 ECM 30 / ECM 60 Hoogspanningsgenerator DC Hochspannungsgenerator DC DC High-Voltage Generator Generateur DC Haute Tension Gebru …
  • Heath Company

    Heathkit AG-7

    (24 pages)
    G. TannenbaumElectronic Service DataP.O. Box 386/Ambler PA 19002Phone 215 657 0106 Fax 215 657 0520Web Page www.agtannenbaum.comEA TH KITMODEL AG-AUDIO GENERATOR …
  • Daikin

    LX10F11B3

    (140 pages)
    TR16-02(2016.01.00100)NKDAIKININVERTERCONTAINERREFRIGERATIONUNITServiceManualTR 16-02ServiceManualDAIKININVERTERCONTAINERREFRIGERATIONUNITLX10F11B3 or later(DECOS Va)LX10F11B3 or laterHeadOffice.UmedaCenterBldg.,4-12,Nakazaki-Nishi2-chome,Kita-ku,Osaka,530-8323Japan.Tel:06-6373-4338Fax: …
  • Schumacher Electric

    PI-750

    (24 pages)
    0099001532-05MODEL / MODELO: PI-750Power InverterConverts 12V DC battery power to 120V AC household power Inversor de EnergíaConvierte la energía de baterías de 12V de CD a 120V de CA de energía domésticaOWNERS MANUALMANUAL DEL USUARIOPLEASE SAVE THIS OWNERS MANUAL AND READ BEFORE EACH USE. This manual will explain how to use the inverter safely and ef …
  • YASKAWA

    VS-616G5 Series

    (84 pages)
    2PREFACEYASKAWA’s VS−616G5 is a user−friendly inverter provided with vector control forstandard models in addition to V/f control. This instruction manual describesinstallation, maintenance and inspection, troubleshooting, and specifications of theVS−616G5. Read this instruction manual thoroughly before operation.YASKAWA ELECTRIC CORPORATIONGeneral P …
  • Micro Innovation

    MSystem GF0

    (36 pages)
    MSystem MICRO PANEL GF0 Device description Micro Innovation AG x Spinnereistrasse 8-14 x CH-9008 St. Gallen x Switzerland Tel. +41 (0)71 243 24 24 x Fax +41 (0)71 243 24 90 www.microinnovation.com x [email protected] GF0 efesotomasyon.com - Klockner Moeller - inverter …

Comments, Questions and Opinions: