  • Hitachi SJ/L-EN Ethernet Communications Module, Chapter 4 Page 17 of 36 Chapter 4 – Operation Setting Up the Inverter for Ethernet Network Operation Once the SJ/L-EN board has been properly configured and connected to a network as described in Chapter 3, it is capable of reading data from and writing data to the inverter. However if it is desired to have either the RUN command and/or the speed reference come from the Ethernet master, you must change two inverter parameters as shown in the following table. Defaults Function Code Name Description Run Mode Edit Lo Hi –

  • Hitachi SJ/L-EN Ethernet Communications Module, Index Page 33 of 36 Index A A - Standard Functions · 22 Activity LED · 11 address, Ethernet · 14 B B - Fine-Tuning Functions · 27 C C - Intelligent Terminal Functions · 28 cable, Ethernet · 13 Carton Contents · 5 Configuration · 13 D D - Monitoring Functions · 21 device ID · 13 DIP-switches · 9, 13 E Error code · 19 Error LED · 11 Ethernet address · 14 F F - Main Profile Functions · 22 H H - Motor Constants and Functions · 30 I Installing · 10 Interface, User · 11 IP address · 14 K keypad, inverter · 19 L layout, board · 9 LEDs · 9, 11, 13 Link LED · 11 M MODBUS Functions, supported · 17 mod

  • Hitachi SJ/L-EN Ethernet Communications Module, Appendix Page 32 of 36 * Data Range depends on Model and/or Rating. Verify that data you are writing is valid for the inverter model and rating you are writing to. ‡ These special parameters are NOT accessible via the standard keypads. They can only be accessed by the SJ/L-EN board. § Parameter only available in L200 and SJ200. † Parameter only available in L100 and SJ100.

  • Hitachi SJ/L-EN Ethernet Communications Module, • SJ100 Series • L100 Series • SJ200 Series • L200 Series NOTE: REFER ALSO TO THE PERTINENT INVERTER INSTRUCTION MANUAL Hitachi America, Ltd. After reading this manual, keep it handy for future reference. Manual Number: HAL1052 December 2005 SJ/L-EN Ethernet Communications Module Instruction Manual

  • Table of Contents Table of Contents Table of Contents................................................................................................................... 3 Chapter 1 – General Description.......................................................................................... 5 Chapter 2 – Installation and Wiring............................................

  • Hitachi SJ/L-EN Ethernet Communications Module, Appendix Page 23 of 36 L200/SJ200 X1 30 – 400 SJ100 X100 5000 – 36000 A204 407 408 Maximum frequency setting, 2 nd motor L100 X1 R/W 50 – 360 A005 9 10 [AT] selection L200/SJ200 X1 R/W 0 – 3 L200/SJ200 0 – 40000 A011 21 22 [O]–[L] input active range start frequency L100/SJ100 X100 R/W 0 – 36000 L200/SJ200 0 – 40000 A012 23 24 [O]–[L] input active range end frequency L100/SJ100 X100 R/W 0 – 36000 A013 25 26 [O]–[L] input active range start voltage X1 R/W 0 – 100 A014 27 28 [O]–[L] input active

  • Hitachi SJ/L-EN Ethernet Communications Module, Chapter2 Page 11 of 36 User Interface The SJ/L-EN has seven LEDs to convey module status and activity. Four LEDs next to the RJ45 connector: • STATUS (GREEN) – This LED will be ON whenever the SJ/L-EN is receiving proper power from the inverter and the self diagnostics have shown the board to be functioning normally. • LINK (GREEN) – This LED is ON when the SJ/L-EN is receiving valid Ethernet pulses. • ACTIVITY (GREEN) – This LED is ON whenever there is Ethernet traffic in the cable. • ERROR (RED) – This LED will be ON if the SJ/L-EN has failed due to a hardware watchdog timeout, or the Eth

  • Appendix Page 21 of 36 Appendix – Parameter List Note: Parameters in BOLDFACE can be edited while inverter is in the RUN mode. “RO” means the parameter is Read Only, and “R/W” means the value can be read or written. Please refer to page 32 for a key to other symbols used in these tables. Inverter Parameter Modbus Start Address Modbus End Address Para

  • Appendix Page 26 of 36 L200/SJ200 X100 -9999 – 300000 A293 585 586 Deceleration time (2), 2 nd motor SJ100 X10 R/W 1 – 30000 A094 187 188 Select method to switch to acc2/dec2 profile X1 R/W 0 – 1 A294 587 588 Select method to switch to acc2/dec2 profile, 2 nd motor (except L100) X1 R/W 0 – 1 L200/SJ200 X10 0 – 4000

  • Appendix Page 25 of 36 L200/SJ200 0 – 40000 A063 125 126 Jump frequency 1 L100/SJ100 X100 R/W 0 – 36000 L200/SJ200 X100 0 – 1000 A064 127 128 Width of jump frequency 1 L100/SJ100 X10 R/W 0 – 100 L200/SJ200 X100 0 – 40000 A065 129 130 Jump frequency 2 L100/SJ100 X100 R/W 0 – 36000 L200/SJ200 X100 0 – 1000 A066 131 132

  • Hitachi SJ/L-EN Ethernet Communications Module, Appendix Page 31 of 36 H031 5061 5062 Motor constant R2, 1 st motor (Auto) (SJ200 Only) X1000 R/W 0 – 65535 H231 5461 5462 Motor constant R2, 2 nd motor (Auto) (SJ200 Only) X1000 R/W 0 – 65535 H032 5063 5064 Inductance L, 1 st motor (Auto) (SJ200 Only) X100 R/W 0 – 65535 H232 5463 5464 Inductance L, 2 nd motor (Auto) (SJ200 Only) X100 R/W 0 – 65535 H033 5065 5066 Io, 1 st motor (Auto) (SJ200 Only) X100 R/W 0 – 65535 H233 5465 5466 Io, 2 nd motor (Auto) (SJ200 Only) X100 R/W 0 – 65535 H034 5

  • Hitachi SJ/L-EN Ethernet Communications Module, Appendix Page 30 of 36 H – Motor Constants and Functions H001 5001 5002 Auto–tuning setting (SJ100 only) X1 R/W 0 – 2 H002 5003 5004 Motor data selection, 1 st motor (SJ100 only) X1 R/W 0 – 1 H202 5403 5404 Motor data selection, 2 nd motor (SJ100 only) X1 R/W 0 – 1 L200/SJ200 0 – 29 * H003 5005 5006 Motor capacity, 1 st motor SJ100 X1 R/W 0 – 10 * L200/SJ200 0 – 29 * H203 5405 5406 Motor capacity, 2 nd motor SJ100 X1 R/W 0 – 10 * H004 5007 5008 Motor poles, 1 st motor (except L100) X1 R/W 2 – 8 H204 5407 5408 Motor poles, 2 nd motor (except L100) X1 R/W 2 – 8 H005 5

  • Hitachi SJ/L-EN Ethernet Communications Module, Chapter 5 Chapter 5 – Troubleshooting In general, the first step to troubleshooting should be to inspect the status LEDs on the SJ/L-EN board, in addition to the inverter operator/keypad display. These will give valuable clues to the nature of the problem. Refer to the description of the proper LED indications on page 11. In addition, the inverter operator/keypad (if installed) will provide diagnostic information for certain types of errors. The error code for a communication error is: E60 The following table summarizes possible error causes and remedies. Code Trip Name Cause Check Re

  • Hitachi SJ/L-EN Ethernet Communications Module, Chapter1 Page 5 of 36 Chapter 1 – General Description The SJ/L-EN module is an Ethernet communication interface for the Hitachi SJ200, L200, SJ100 and L100 series of AC Variable Frequency Inverters. The module is mounted externally to the inverter. The SJ/L-EN uses the open MODBUS/TCP communication protocol. It utilizes a 10Base-T physical interface with a 10 Mbps data transfer rate. Even though the board uses the MODBUS/TCP, this does not necessarily mean that all MODBUS services and functions are supported. Detailed description of the available functionality is provided in Chapter 4 of this manual. The board wi

  • Hitachi SJ/L-EN Ethernet Communications Module, Appendix Page 24 of 36 L200/SJ200 X10 0 – 200 A042 83 84 Manual torque boost value L100/SJ100 X1 R/W 0 – 99 L200/SJ200 X10 0 – 200 A242 483 484 Manual torque boost value, 2 nd motor (except L100) SJ100 X1 R/W 0 – 99 A043 85 86 Manual torque boost frequency adjustment X10 R/W 0 – 500 A243 485 486 Manual torque boost frequency adjustment, 2 nd motor (except L100) X10 R/W 0 – 500 L200/L100 0 – 1 A044 87 88 V/f characteristic curve selection, 1 st motor SJ200/SJ10 0 X1 R/W 0 – 2 L200 0 – 1 A244 487 488 V/f characteristic curve selection, 2 nd motor (except L100) SJ200/SJ10 0 X1

  • Hitachi SJ/L-EN Ethernet Communications Module, Chapter1 Page 7 of 36 CAUTION: Be sure not to touch the surface or terminals of the SJ/L-EN Ethernet module while the inverter is energized; otherwise there is the danger of electric shock. CAUTION: The software lock modes described in the inverter manuals are NOT supported via the SJ/L-EN module. This means that network commands can bypass any software lock settings configured via the inverter keypad. It is incumbent on the user to make sure no safety lockouts are violated through network commands. CAUTION: When configuring parameters with the standard keypad,

  • Hitachi SJ/L-EN Ethernet Communications Module, Appendix Page 22 of 36 F – Main Profile Functions L200/SJ200 X10 0 – 4000 F001 4001 4002 Output frequency setting(Hz) / PID Setpoint (%) L100/SJ100 X100 RO 0 – 36000 L200/SJ200 X100 -9999 – 300000 F002 4003 4004 Acceleration time 1 L100/SJ100 X10 R/W 0 – 30000 L200/SJ200 X100 -9999 – 300000 F202 4403 4404 Acceleration time 1, 2 nd motor SJ100 (NOT L100) X10 0 – 30000 L200/SJ200 X100 1 – 30000 -9999 – 300000 F003 4005 4006 Deceleration time 1 L100/SJ100 X10 R/W 0 – 30000 L200/SJ200 X100 -9999 – 300000 F203 4405 4406 Deceleration time 1, 2 nd motor SJ100 (NOT L100) X10 R/W 0 �

  • Hitachi SJ/L-EN Ethernet Communications Module, Chapter3 Page 14 of 36 Figure 3-1 NetEdit3 Initial Screen The NetEdit3 software should find and list any SJ/L-EN attached to the network. If not, just click on “Scan Network”. An entry will appear in the Device List (grid area), with the board details as shown in Figure 3-2. If more than one board is connected in a common network, you will see a line entry for each of them. The “Module Info” and “General Settings” tabs will now also appear next to the “General Help” tab, below the Device List. You can then click on the line for the board you wish to configure, and click

Related Products and Documents (Network Card):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Hitachi CP-X3010Z Specifications hitachi/cp-x3010z-Q7G.pdf 17 Mar 2023 1 0.71 Mb
2 AGFA SnapScan 1212u Owner's manual agfa/snapscan-1212u-S45.pdf 29 Sep 2023 31 0.69 Mb
3 Blodgett ZEPHAIRE-E Installation & operation manual blodgett/zephaire-e-Z27.pdf 31 Oct 2023 44
4 Gefen COMPAUD-141 Operation & user’s manual gefen/compaud-141-7O7.pdf 14 Aug 2023 10 0.28 Mb
5 Grizzly G9959 Instruction manual grizzly/g9959-G85.pdf 31 Mar 2023 52 3.28 Mb
6 Vivitar Vivicam 3745 Operation & user’s manual vivitar/vivicam-3745-22V.pdf 07 Nov 2022 67 1.37 Mb

Similar Resources:

  • NETGEAR

    MA301

    (2 pages)
    NETGEAR’s MA301 802.11b Wireless PCI Adapter enables you to easily network all of your employees at 11 Mbps speed without installing any newwires. (An MA401 Wireless PC Card is required and is sold separately.) Setup a new wireless network or extend your existing workplace to remote sitesin your building in no time, and escape the hassles and expense of Et …
  • Panasonic

    Schottky Barrier Diodes MA27E02

    (3 pages)
    Schottky Barrier Diodes (SBD)1Publication date: November 2003 SKH00129AEDMA27E02Silicon epitaxial planar typeFor cellular phone■ Features• High-frequency wave detection is possible.• Low forward voltage VF• Small terminal capacitance Ct■ Absolute Maximum Ratings Ta = 25°CParameter Symbol Rating UnitReverse voltage VR20 VMaximum peak reverse volta …
  • Panasonic

    Micro-Imagechecker AX40

    (15 pages)
    2009.3panasonic-denko.co.jp/ac/eARCT1F463EPanasonic Electric WorksAX40MACHINE VISION SYSTEMRead this with User’s Manual(Hardware, Operations)User’s Manual(Color Extraction) MICRO-IMAGECHECKER …
  • Panasonic

    Schottky Barrier Diodes MA24D60

    (2 pages)
    Schottky Barrier Diodes (SBD) Publication date: November 2005 SKH00151AED 1MA24D60Silicon epitaxial planar typeFor rectification Features Forward current (Average) IF(AV) = 2.0 A rectification is possible Low forward voltage VF Absolute Maximum Ratings Ta = 25°CParameter Symbol Rating UnitReverse voltageVR40 VMaximum peak reverse voltageVRM …
  • Intermate

    Twinax Connection LX T-04

    (81 pages)
    LX T-04TwinaxConnectionUser's GuideDocument GM-001-5Fifth edition of the Intermate LX T-04 Twinax Connection User’s GuidePrinted in DenmarkNo part of this guide may be photocopied or reproduced in any way, exceptwhere noted, without the written consent of LCI Intermate A/S.© Copyright LCI Intermate A/S 1998 and 1999. All rights reserved. …
  • 3Com

    OfficeConnect 3C855

    (4 pages)
    Using Remote Management with the OfficeConnect Cable/DSL Gateway (3C855) and OfficeConnect Wireless Cable/DSL Gateway (3CRWE51196) The OfficeConnect Cable/DSL Gateway and OfficeConnect Wireless Cable/DSL Gateway can be remotely managed across the Internet. This would allow a remote user to configure the Gateway while away from the office. A typica …

Comments, Questions and Opinions: