Manualios.com

Sub-Zero Freezer Operation & User’s Manual

Sub-Zero Freezer Manual Online:

4.55, 2167 votes
Sub-Zero Freezer User Manual
Sub-Zero Freezer User Guide
Sub-Zero Freezer Online Manual

Text of Sub-Zero Freezer User Guide:

  • Sub-Zero Freezer, SUB-ZERO ® is a registered trademark of Sub-Zero Freezer Company, Inc. As you follow these instructions, you will notice WARNING and CAUTION symbols. This blocked information is important for the safe and efficient installation of Sub-Zero equipment. Ther e are two types of potential hazards that may occur during installation. Another footnote we would like to identify is IMPOR T ANT NOTE: This highlights infor ma - tion that is especially r elevant to a pr oblem- fr ee installation. signals a situation where minor injury or pr oduct damage may occur if you do not follow instructions. states a hazard that may cause serious injur y or death if pr ecautions ar e not followed. CONTENT

  • 3 Dimensions in parentheses are in millimeters unless otherwise specified. TOOLS AND MATERIALS REQUIRED T he following is a list of tools and materials that should be available for proper installation. Phillips screwdriver set S lotted screwdriver set Torx drive screwdriver set 4' (1.2 m) of 1 /4" copper tubing and saddle valve for the water line—part #4200880 (do not use self

  • Sub-Zero Freezer, 4 INSTALLATION SPECIFICATIONS Make sure that the actual equipment that was shipped to you matches the design you are e xpecting to install. The Sub-Zero Built-In line offers the following design alternatives— framed, overlay and stainless steel models. Each of these design options has specific i nstallation requirements, which means it is vital that the unit match your planning and space needs. Before you begin the installation process, check the exact model number you need against the model number on the shipping carton. If the unit you

  • Sub-Zero Freezer, 5 Dimensions in parentheses are in millimeters unless otherwise specified. 36" (914) 7 3" (1854) 3 6" (914) 7 3" ( 1854) 36" (914) 24" (610) 7 3" (1854) 72 3 /4" (1848) ROUGH OPENING HEIGHT TO FINISHED FLOORING 72 3 /4" (1848) MINIMUM HEIGHT REQUIRED TO FINISHED FLOORING (LEVELERS IN) 24" (610) ROUGH O PENING DEPTH 11" (279) 3" (76) 24" (610) W LOCATE WATER SUPPLY WITHIN BOTTOM SHADED AREA ONLY (601F ONLY ) LOCATE ELECTRICAL WITHIN ENTIRE SHADED AREA 6" (152) E SHUT-OFF VALVE EXTEND WATER LINE APPROX 36"

  • 6 BUILT-IN INSTALLATION SPECIFICATIONS 30" (762) 84" (2134) 36" (914) 84" (2134) 30" (762) 84" (2134) 36" ( 914) 24" ( 610) 84" (2134) 83 3 /4" (2127) ROUGH OPENING HEIGHT TO FINISHED FLOORING WITH STANDARD 11" (279) GRILLE 83" (2108) MIN HEIGHT REQUIRED TO FINISHED FLOORING (LEVELERS IN) 75 1 /2" (

  • Sub-Zero Freezer, 7 Dimensions in parentheses are in millimeters unless otherwise specified. 36" ( 914) 42" ( 1067) 4 8" (1219) 42" (1067) 48" ( 1219) 24" ( 610) 84" ( 2134) 83 3 /4" (2127) ROUGH OPENING HEIGHT TO FINISHED FLOORING WITH STANDARD 11" (279) GRILLE 83" (2108) MIN HEIGHT REQUIRED TO FINISHED FLOORING (LEVELERS IN) 75 1 /2" (1918) 7" (178) 6" (152) A ROUGH OPENING WIDTH 24" (610) R OUGH OPENING DEPTH E 3" (76) 18" (457) W LOCATE WATER SUPPLY WITHIN SHADED AREA LOCATE ELECTRICAL WITHIN SHADED AREA 6" (152) SHUT-OFF VALVE FRONT V

  • Sub-Zero Freezer, Dimensions in parentheses are in millimeters unless otherwise specified.8 ELECTRICAL REQUIREMENTS A 115 V AC, 60 Hz, 15 amp circuit breaker and e lectrical supply are required. A separate circuit, servicing only this appliance, is required. All Sub-Zero Built-In models are equipped with a power supply cord with a 3-prong grounding p lug, which must be plugged into a mating 3-prong grounding-type wall receptacle. Follow the National Electrical Code and local codes and ordinances when installing the receptacle. For location of the electrical supply, refer to the Installation Specifications illustration

  • 9 UNPACK THE UNIT Uncrate the unit, remove its wood base and d iscard the shipping bolts that hold the wood base to the bottom of the unit. Remove all packing materials and tape. IMPORTANT NOTE: Do not discard the kickplate, anti-tip blocking kit and hardware. T hese items will be needed for installation. Retract the front leveling legs to allow you to move the unit m

  • POSITION THE UNIT S hut off power to the wall outlet. P lug the power supply cord into the 15 amp grounded outlet and roll the unit into position under the wood block or soffit. Using the front and rear leveling legs, raise the unit until it makes contact with the wood block. See Level the Unit, page 11. IMPORTANT NOTE: If possible, keep door(s) closed on the unit u

  • Sub-Zero Freezer, 11 Dimensions in parentheses are in millimeters unless otherwise specified. WATER LINE CONNECTION To connect the ice maker water line, remove the 1 /4" compression fitting from its plastic bag a nd join the water supply line to the solenoid valve. Refer to illustration 7 below. NOTE: The water valve can be removed from the m ounting bracket to gain easier access to water connection. Be sure to purge the line before making the final connection. IMPORTANT NOTE: Turn on the water supply and check all fittings for leaks. Make certain the electrical harness is attached to the solenoid. In areas with water of high m

  • Sub-Zero Freezer, 12 PANEL INSTALLATION Before you begin installing panels, refer to the Panel Specifications for framed or overlay m odels and be sure you are working with the panel design called for in your installation. If your customer has chosen the stainless steel d esign, the unit has been shipped complete with a finished stainless steel look. It will not be necessary to install panels or handle hardware. In your final preparation for stain- less steel units, use a stainless steel cleaner to remove any marks. Abrasive cleaners should not be used, as they may scratch the surface. If your customer has ordered either a framed or overlay model, you will be installing panels t

  • Sub-Zero Freezer, 13 Dimensions in parentheses are in millimeters unless otherwise specified. MODELS 685 AND 695 FRAMED KITS PARTIAL FRAMED ACCESSORY KIT I f you choose not to use custom wood panels above or below the glasswell for the Model 685 or 695 framed application, a stainless steel i nsert panel will be provided with the partial framed accessory kit. This accessory kit (part #FRAMPAR), available through your Sub-Zero dealer, includes molding and a stainless steel insert panel for above and below the glasswell on a framed uni

  • Sub-Zero Freezer, 14 C C C H W H A B D 14" (356) H W H A B 14"(356) C FRAMED DOOR PANELS A ll Refrigerator | All Freezer Framed (F) Models Model 601R W H Refrigerator Framed Panel 34 1 /8" (867) 58 15 /16" (1497) Raised Panel Handle Recess Location – Refrigerator Panel A) 29 15 /3 2 " (749) Model 601RG W H Refrigerator Framed Panel 34 1 /8" (867) 58 15 /16" (1497) Raised Panel Handle Recess Location – Refrigerator Panel A) 29 1 5 /32" (749) Window Cut-out Dimensions 25 3 /8" (645) 41 3 /16" (1046) Window Cut-out Location C) 4 3 /8" (111) D) 13 3 /8" (340) Model 601F W H Freezer Framed Panel 34 1 /8" (867)

  • Sub-Zero Freezer, 15 Dimensions in parentheses are in millimeters unless otherwise specified. PARTIAL FRAMED DOOR PANELS I ce | Water Dispensing Framed (F) Models Model 685 W H Refrigerator Partial Framed Panel 15 5 /8" (397) 67 11 /1 6 " (1719) Freezer Partial Framed Panel 15 5 /8" (397) 67 11 /16" (1719) Model 695 W H Refrigerator Partial Framed Panel 17 1 5 /1 6 " (456) 67 1 1 /1 6 " (1719) F reezer Partial Framed Panel 1 7 1 5 /1 6 " (456) 67 1 1 /1 6 " (1719) T he partial framed accessory kit (FRAMPAR) is required for this option. Kit includes partial framed molding and classic stainless steel inset h andle panels fo

  • 16 OVERLAY PANELS If your customer has chosen an overlay design a pplication, make sure that the panels you are about to install match dimensions listed in the Overlay Panel Specifications on pages 18–19. IMPORTANT NOTE: The size of the overlay p anel is critical. It must fit over the door frame. Overlay models are shipped without handle hardware. The cabinet manufacturer or des

  • Sub-Zero Freezer, 17 Dimensions in parentheses are in millimeters unless otherwise specified. MODELS 685 AND 695 GLASSWELL The dispenser area of Models 685 and 695 has been engineered to enable the use of the o verlay panel application. Installing overlay panels for these models is the same procedure as for other Built-In models. The refrigerator d oor panel will need to accommodate a cut-out for the glasswell bezel. To remove the glasswell bezel for an overlay Model 685 or 695, the water grille and touch pad must be removed. Lift the water grille up and out. Next, remove the touch pad assembly which is taped in place, by removing the center plas

  • Sub-Zero Freezer, 18 C C C H W H D H W H C W H C C D W H OVERLAY DOOR PANELS A ll Refrigerator | All Freezer Overlay (O) Models Model 601R W H Refrigerator Overlay Panel 34 7 /1 6 " (875) 59 1 /4" (1505) Refrigerator Spacer Panel 33 1 /2" (851) 58 5 /16" (1481) R efrigerator Backer Panel 3 4 1 /8" (867) 58 1 5 /16" (1497) Model 601RG W H R efrigerator Overlay Panel 3 4 7 /1 6 " (875) 59 1 /4" (1505) Refrigerator Spacer Panel 33 1 /2" (851) 58 5 /16" (1481) Refrigerator Backer Panel 34 1 /8"

  • Sub-Zero Freezer, 19 OVERLAY GRILLE PANELS O verlay (O) Models W idth Dimensions Models 611 and 611G W Overlay Panel Width 28 7 /16" (722) Spacer Panel Width 27 1 /2" (699) Backer Panel Width 28 1 /8" (714) Models 650, 650G, 661 W O verlay Panel Width 3 4 7 /1 6 " (875) Spacer Panel Width 33 1 /2" (851) Backer Panel Width 34 1 /8" (867) Models 642 and 685 W Overlay Panel Width 40 7 /16" (1027) S pacer Panel Width 3 9 1 /2" (1003) Backer Panel Width 40 1 /8" (1019) M odels 632 and 695 W Overlay Panel Width 46 7 /16" (1180) S pacer P anel Width 45 1 /2" (1156) Bac

  • Sub-Zero Freezer, SIDE PANEL INSTALLATION OPTIONS Dimensions in parentheses are in millimeters unless otherwise specified.20 SIDE PANEL INSTALLATION If you’re installing a Built-In model with side p anels, check with your installer or use one of the following Side Panel Installation Options. D rill three holes equidistant in a vertical section of the aluminum frame, and install pan head screws. Do not drill through model and s erial number plate. Anchor the side panel with decorative screws or finishing nails from a local hardware store. Do not use adhesives. Refer to illustration 16 below. The dimensions given in t

  • Sub-Zero Freezer, 21 ANCHOR THE UNIT After door and side panels have been installed, the unit has been leveled and door adjustment c ompleted, anchor the unit to the opening. This will assure a proper fit and a secure installation. The Sub-Zero Anchoring Kit (part # 4200900), available from your Sub-Zero dealer, includes the necessary hardware. IMPORTANT NOTE: Be sure to level and square the unit before anchoring it. TWO UNITS ANCHORED TOGETHER Drill three 13 /64" holes through the middle trim of both units. Using the Loctite on the screws, install the three Chicago screw posts. Recheck the units for level. Drill three 3 /16" holes through both outer trims. Refer to illustration 18 below. Us

  • Sub-Zero Freezer, Dimensions in parentheses are in millimeters unless otherwise specified.22 INSTALLATION CHECKLIST The importance of the installation of the Sub-Zero Built-In unit cannot be overempha- s ized. Proper installation is the responsibility of the selling dealer or installer. IMPORTANT NOTE: To ensure a safe and proper installation, the following checklist s hould be completed by the installer to ensure that no part of the installation has been over- looked. Any questions or problems about the installa- tion should be directed to your Sub-Zero dealer or the Sub-Zero Customer Service Department at 800-222-7820 or e-mail [email protected]. You can also visit our website at subzero.c

  • Sub-Zero Freezer, SERVICE INFORMATION If you need service, be sure to have the model and serial number when you call. You’ll find t hese numbers on the model and serial number on the plate at the top frame of the unit inside the door. Contact a Sub-Zero Factory Authorized Service C enter, a Sub-Zero dealer, or the Sub-Zero Customer Service Department, P. O. Box 44130, Madison, WI 53744-4130, call 800-222-7820 or e-mail [email protected]. 23 If you are storing or disposing of your old refrigerator or freezer, please do it safely. Remove the doors or tightly secure the doors closed. Child entrapment accidents can be tragic. CONTACT INFORMATION Sub-Zero Customer Service: 800-222-7820 Website

Related Products and Documents (Freezer):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 BT Converse 1300 Operation & user’s manual bt/converse-1300-9R7.pdf 22 Sep 2022 33 5.36 Mb
2 PurePro MH-943 Operation & user’s manual purepro/mh-943-GK1.pdf 25 Dec 2023 4
3 Asus Motherboard P5PL2 Operation & user’s manual asus/motherboard-p5pl2-654.pdf 15 Jan 2024 116 4.92 Mb
4 Casio XJ-H1600 Setup manual casio/xj-h1600-DWT.pdf 27 Jan 2023 26 0.77 Mb
5 Converters.TV 15403 Operation manuals converters-tv/15403-MJB.pdf 11 May 2023 6
6 Toshiba BDX1100KU Owner's manual toshiba/bdx1100ku-WU7.pdf 22 Nov 2023 46 5.33 Mb

Similar Resources:

  • AEG

    ARCTIS G 9 18 50-4 i

    (20 pages)
    ARCTIS G 9 18 50-4 iIntegrating FreezerOperating and Installation InstructionsAEG Addington WayLUTONBedfordshireLU4 9QQhttp://www.aeg.co.uk© Copyright by AEG2223 383-01 04/06 Subject to change without notice …
  • Miele

    K1911SF

    (2 pages)
    NOTE: Drawing is not to scale.SPECIFICATION SHEETS 011208Product and Cut-out Dimensions72" Side by Side CombinationF1911SF & K1901SF72"24" min.84"35 3/4"3 1/2" - 5 3/8"35 3/4"83 1/2" - 85 3/8"9 1/2"23 1/2"1 1/4"Notes• See individual unit specs for location information• KTF1072 Upper fr …
  • Hussmann

    GGSM

    (13 pages)
    January 2006HUSSMANN - GLOVERSVILLE INSTALLATION & SERVICE INSTRUCTIONS FOR GGSM SPECIALTY MERCHANDISER Low Temperature Glass Front and SidesP/N OII – GGSMJanuary 2006 First Call for help (US and Canada): 1-800-922-1919 Soporte Tècnico y Asistenc …
  • Climate Wizard

    CW-H10

    (36 pages)
    INSTALLATION CW-H10OPERATION CW-H15MAINTENANCEIndirect Evaporative Air Cooler!!!STAND ALONE COOLING -SUPPLEMENTARY COOLING -COLD FRONT COOLING -Climate Wizard is the primary source of AirConditioning for the building.Climate Wizard is used to augment the capacityof the existing air conditioning system, or to extend its reach into the building, or togreatly r …
  • McDonald's

    C602

    (43 pages)
    ©McDonald’s Corporation · Planned Maintenance Manual · Revised January, 2021 Hazards These icons alert you to a possible risk of personal injury. Equipment alerts Look for this icon to find information about how to avoid damaging the equipment while doing a procedure. Tips Look for this icon to find helpful tips about how to do a procedure. MILKSHAKE …
  • THOMSON

    THFZ 165

    (79 pages)
    THFZ165CongélateurverticalsansgivreFrost‐FreeUpright‐FreezerFrost‐Freerechtop‐diepvriezerSinescarchaUpright‐FreezerFrost‐FreeSkříňovémrazničkyFrost‐FreeSkriňovémrazničkyMANUALD’UTILISATIONOPERATINGINSTRUCTIONSHANDLEDING� …

Comments, Questions and Opinions: