Honeywell XYR 5000 Line Operation & User’s Manual
|
Honeywell XYR 5000 Line, Honeywell Industrial Wireless Wireless Base Radio Rev. 3 User Manual 23 11/04 Appendix A: Navigating the Menus Pressing either the NEXT or ENTER buttons located on the front of the Transmitter or Base Radio just below the Liquid Crystal Display (LCD) screen is all that is needed to navigate the respective menus. Pressing both of these buttons for one second will turn the unit on. Pressing the NEXT button at any time while the Base Radio is cycling through the normal messages causes the Base Radio to enter the setup mode. The NEXT button is then used to st
Honeywell XYR 5000 Line, 8 Rev. 3 User Manual 11/04 Honeywell Industrial Wireless Wireless Base Radio 3.2.6: Daisy-Chaining Multiple Base Radios to Single RS-485/ Power Two or more Base Radios may be placed on a single RS-485 communica- tion line, an a single power supply line (provided the power supply and wiring can handle the load). This section will provide the information needed to daisy-chain multiple Base Radios. However, be sure to complete Section 3.2.8 on correct Base Radio termination if doing so. 3.2.6.1: Daisy-Chaining Power to Multi- ple Base Radios
Honeywell XYR 5000 Line, Honeywell Industrial Wireless Wireless Base Radio Rev. 3 User Manual III 11/04 Table of Contents Section 1: Introduction__________________________________1 1.1: Using This Manual 1 1.2: About the Device 2 1.3: Unpacking 2 1.4: Software Compatibility 2 Section 2: In a Hurry? __________________________________3 Section 3: Installation___________________________________4 3.1: Mechanical Installation 4 3.1.1: Base Radio Positioning 4 3.1.2: Base Radio Mounting 5 3.2: Electrical Installation 5 3.2.1: Electrical Spec
12 Rev. 3 User Manual 11/04 Honeywell Industrial Wireless Wireless Base Radio Section 5: Configuring the RF Communications In order for the Base Radio and the Transmitter to communicate they must be on the same RF Channel, and must be transmitting at the same Baud Rate. While all Transmitters and Base Radios are set to default configura- tions at th
Honeywell XYR 5000 Line, Honeywell Industrial Wireless Wireless Base Radio Rev. 3 User Manual 25 11/04 Appendix C: Modbus Register Definitions /* Temperature Units */ DegC = 32, /* Degrees Celcius */ DegF = 33, /* Degrees Fahrenheit */ DegR = 34, /* Degrees Rankine */ DegK = 35, /* Kelvin */ /* Pressure Units */ InH2OAt68F = 1, /* inches of water at 68 degF */ InHgAt0C = 2, /* inches of mercury at 0 degC */ FtH2OAt68F = 3, /* feet of water at 68 degF */ MMH2OAt68F = 4, /* millimeters of water at 68 degF */ MMHgAt0C = 5, /* millimeters of mercury at 0 degF */ PSI = 6, /* pounds
Honeywell XYR 5000 Line, Honeywell Industrial Wireless Wireless Base Radio Rev. 3 User Manual 27 11/04 /* Density Units */ SGU = 90, /* specific gravity units */ GramPerCuCm = 91, /* grams per cubic centimeter */ KGPerCuMeter = 92, /* kilograms per cubic meter */ PoundsPerGal = 93, /* pounds per gallon */ PoundsPerCuFt = 94, /* pounds per cubic foot */ GramsPerML = 95, /* grams per milliliter */ KGPerLiter = 96, /* kilograms per liter */ GramsPerLiter = 97, /* grams per liter */ PoundsPerCuIn = 98, /* pounds per cubic inch */ ShTonPerCuYard = 99, /* short tons per cubic yard */ DegTwad
Honeywell XYR 5000 Line, 10 Rev. 3 User Manual 11/04 Honeywell Industrial Wireless Wireless Base Radio Section 4: General Configuration This section discusses the generalities around configuring the Base Radio via the next and enter buttons. The subsections are as follows: 4.1: Base Radio Displayed Messages 4.1.1: The Read-Only Sequence 4.2: The Overall Configuration Menu Map 4.3: The Number of Wireless Instruments Setting 4.4: Setting a User Password Figure 4.1: Base Radio Power-Up and Operations LCD Sequences The Base Radio should be on if power is being supplied (See Section 3.2: Electrical Installation). Upon power-up, the Base Radio will displ
20 Rev. 3 User Manual 11/04 Honeywell Industrial Wireless Wireless Base Radio 6.3.2: Command 08- Diagnostic This command provides a number of tests for checking the communica- tions between the Base Radio and the Host master device. Sub-function Code Transmitter Device Status 0 Return Query Data 1 Restart Communications Option 2 Return Diagnos
Honeywell XYR 5000 Line, 14 Rev. 3 User Manual 11/04 Honeywell Industrial Wireless Wireless Base Radio The Modbus Device ID allows a PLC or DCS to find the proper Base Ra- dio on a RS-485 Network. Because Modus needs a device ID for each Transmitter, they have been virtually mapped according to the Base Radio with which they are com- municating. The device ID range is dependent on the MODMAP setting in the Base Radio. (See Modbus Mapping Mode section 6.1.4 for more infor- mation.) In the Register Mapping Mode you may select any device ID from 1 to 247. This number will be the device ID at which all the re
Honeywell XYR 5000 Line, IV Rev. 3 User Manual 11/04 Honeywell Industrial Wireless Wireless Base Radio 3.1: General Layout .................................................................................................. 4 3.2: Overall Wiring Schematic ................................................................................. 5 3.3: Terminal Block Labels ...................................................................................... 5 3.4: Wiring Power to the Base Radio ....................................................................... 6 3.5: W
Honeywell XYR 5000 Line, Honeywell Industrial Wireless Wireless Base Radio Rev. 3 User Manual 1 11/04 Section 1: Introduction 1.1: USING THIS MANUAL This manual is designed to assist in installing, operating, and maintaining Honeywell Model WBR Base Radios. The manual is broken into sections as follows: Section 2: In a Hurry? This section summarizes what must be done in order to get the device in- stalled, configured and in operation quickly. However, it does not provide detailed or how-to information to perform t
Honeywell XYR 5000 Line, 28 Rev. 3 User Manual 11/04 Honeywell Industrial Wireless Wireless Base Radio /* Resistance Units */ Ohms = 37, /* ohms */ KOhms = 163, /* kilo ohms */ /* Angle Units */ Deg = 143, /* degrees */ Rad = 144, /* radians */ /* Conductance Units */ MicroSiemens = 56, /* micro siemens */ MilliSiemensPerCM= 66, /* milli siemens per centimeter */ MicroSiemensPerCM= 67, /* micro siemens per centimeter */ /* Volume per Volume Units */ VolumePercent = 149, /*
Honeywell XYR 5000 Line, 26 Rev. 3 User Manual 11/04 Honeywell Industrial Wireless Wireless Base Radio /* Velocity Units */ FtPerSec = 20, /* feet per second */ MetersPerSec = 21, /* meters per second */ InPerSec = 114, /* inches per second */ InPerMin = 115, /* inches per minute */ FtPerMin = 116, /* feet per minute */ MetersPerHr = 120, /* meters per hour */ /* Volume Units */ Gallons = 40, /* gallons */ Liters = 41, /* liters */ ImpGallons = 42, /* imperial gallons */ CuMeters = 43, /* cubic meters */ Barrels = 46, /* barrels */ Bushels =
Honeywell XYR 5000 Line, Honeywell Industrial Wireless Wireless Base Radio Rev. 3 User Manual 11 11/04 A complete Base Radio Menu Map is shown in Appendix B. Below is an overall view of the configuration menu to aid the user in setting up the Base Radio for proper operation. Figure 4.3: Overall Configuration Menu Map 4.2: Overall Configuration Menu Map NOTE The user must enter a four digit password to enter the CONFIG and DIAGNSE. The FACTORY menu is for factory use only. The default user password is 0000. For more inform
Honeywell XYR 5000 Line, Honeywell Industrial Wireless Wireless Base Radio Rev. 3 User Manual 9 11/04 Section 3: Installation 3.2.7: Terminating the Base Radio RS-485 is capable of maintaining communications over a maximum dis- tance of 4000 feet. In most (and we recommend all) situations the unit that comprises an “end” of an RS-485 network should be terminated by a resis- tor wired across the A and B wires. In the case of a daisy-chained application the end unit should be termi- nated. The end unit is the
Honeywell Industrial Wireless Wireless Base Radio Rev. 3 User Manual 19 11/04 6.3.1.2.1: Transmitter Device Type Registers The following are possible values for the Device Type holding registers. Note that the register is a 32-bit floating point value for Transmitters. Value Device Type 0 Acoustic Monitor Tran
22 Rev. 3 User Manual 11/04 Honeywell Industrial Wireless Wireless Base Radio Power Characteristics • 10VDC-30VDC, 24 VDC @ 200mA typical RF Characteristics • 902 MHz – 928 MHz Frequency Hopping Spread Spectrum (FHSS), FCC certified ISM li- cense-free band • Up to 3000’ range to Transmitters with clear line of sight; 500’ to 1000’
Honeywell XYR 5000 Line, Honeywell Industrial Wireless Wireless Base Radio Rev. 3 User Manual 5 11/04 3.2: Electrical Installation In this section wiring instructions are discussed for the various setup capa- bilities of the Base Radio. The subsections are as follows: 3.2.1: Electrical Specifications 3.2.2: Wiring Power to the Base Radio 3.2.3: Wiring RS-485 to the Base Radio 3.2.4: Wiring the RS-485/232 Converter to the Base Radio 3.2.5: Wiring the RS-485/USB Converter t
Honeywell XYR 5000 Line, 6 Rev. 3 User Manual 11/04 Honeywell Industrial Wireless Wireless Base Radio Caution Make sure only ONE power supply is routed to the Base Radio at any time! (Does not apply to Loop Power Supplies) ! ! The Honeywell Base Radio is designed to use a 24 VDC power supply at a minimum of 0.5 Amps. Honeywell offers 110VAC/120VAC-15W DIN rail mounted 24VDC converter for this purpose. For more information contact your Honeywell Representative. The Ground or Negative wire should be placed in the left most slot labeled �
Philips OR7200 Radio Operation & user’s manual
OR7200 |
Roberts Revival RD-60 Radio Operation & user’s manual
Revival RD-60 |
Honeywell ISM BAND XYR 5000 LINE Radio Operation & user’s manual
ISM BAND XYR 5000 LINE |
Honeywell FMC2000 Radio Operation & user’s manual
FMC2000 |
HP OMNIBER 718 37718A Radio Operation & user’s manual
OMNIBER 718 37718A |
Etón FIELD RADIO 550 Radio Owner's manual
FIELD RADIO 550 |
CG Antenna SB-2000 Radio Operating manual
SB-2000 |
Hallicrafters S-120 Radio Owner's manual
S-120 |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Asus | A53TK | Manual | asus/a53tk-J4N.pdf | 08 Dec 2023 | 113 | 7 Mb |
2 | ROSE DISPLAYS | ROPOLE-OMNI HEAD WITH MAGNETS | Manual | rose-displays/ropole-omni-head-with-magnets-VL6.pdf | 15 Oct 2022 | 2 | 0.06 Mb |
3 | Harman Kardon | HK930 | Instruction manual | harman-kardon/hk930-1TP.pdf | 29 Feb 2024 | 13 | 2.36 Mb |
4 | Butler | OOOI | Operation & user’s manual | butler/oooi-K7K.pdf | 27 Feb 2023 | 4 | |
5 | Fujitsu | FP-1000 | Manual | fujitsu/fp-1000-569.pdf | 10 Jul 2023 | 6 | 5.24 Mb |
6 | Whirlpool | MK1157XJ | Installation instructions | whirlpool/mk1157xj-8ZA.pdf | 22 Feb 2024 | 4 | 0.17 Mb |
Tait
MMA-00003-02 Issue 2© Tait Electronics Ltd September 2004. All rights reserved. Directive 1999/5/EC Declaration Directive 1999/5/EC Declaration of Conformityda DanskUndertegnede Tait Electronics Ltd erklærer herved, at følgende udstyr TMAB1C, TMAD1C & TMAH5C overholder de væsentlige krav og øvrige relevante krav i direktiv 1999/5/EF.Se endvidere: ht …
TM8200 mobiles(56 pages) |
Mercury
one|Windshield / Wiper WasherThe multifunction lever controls thewindshieldwiper modes, speeds and the windshield washer. Rotate the end of thecontrol away from you to increase the speed of the wipers. Rotate the control towardsyou to decrease the speed of the wipers.For windshield washercontrol, push the end of the stalk briefly to cause a single swipeof th …
Sable 2008(2 pages) |
Oregon Scientific
EN1Portable Public Alert RadioModel: WR108USER MANUALCONTENTSIntroduction ............................................................ 2About the National Weather Radio System ......... 2Consumer Electronics Association (CEA) .......... 2Product Overview .................................................... 3 Front View ............................. …
WR108(20 pages) |
JBL
English............................... 2Français .......................... 15Deutsch........................... 28Italiano ............................ 41Español ........................... 54Nederlands..................... 67한 글 ............................... 80Dansk .............................. 93Japanese ...................... 106中文......... …
ON TIME MICRO(188 pages) |
Tesco
Read these instructions.Heed all warnings.Follow all instructions.Do not use this apparatus near water.Clean only with a slightly damp cloth.Do not block any ventilation openings.Install in accordance with the manufacturer’sinstructions.Do not install or operate near any heat sourcessuch as radiators, stoves, or other apparatus thatproduce heat.Unplug this …
DAB111V(2 pages) |
Tangent
ALIO BAZECD/DAB+/DAB/FM/Bluetooth radioUser’s manualMode d’emploiBedienungsanleitungGebruikershandleidingBrugermanualBruksanvisningKäyttöopasManuale utenteManual del usuarioManual do utilizador
…
ALIO BAZE(239 pages) |
Wasp Lawn Mower Accessories WASPcam 9905Lawn Mower Accessories #LDPWBU WASPcam 9905, 13 |
Samsung Projection TV HCM4216WSamsung HCM4216W Manual (Owner's instructions manual), @FNMN4Y HCM4216W, 67 |
Bosch Washer Maxx 5#I8JSJ9: Maxx 5 Washer Operating and installation instructions Maxx 5, 63 |
Watermaid Swimming Pool Filter WM10LEDWatermaid WM10LED User Manual (Owner's handbook manual), @61C3H8 WM10LED, 12 |
Iron-A-Way Iron E-46#9YRZGA E-46: Iron-A-Way Iron Owner Documentation E-46, 4 |
Mitsubishi Projector FL7000LUMitsubishi FL7000LU Projector Specifications FL7000LU, 2 |
Raypak Network Card Latching Lockout Module C-5Raypak Latching Lockout Module C-5 User Manual (Doc Type: Network Card Product manual) Latching Lockout Module C-5, 2 |
Intel Motherboard D925XEBC2Motherboard Specification (Intel D925XEBC2) D925XEBC2, 11 |
CAMBRIDGE Receiver CXR200CAMBRIDGE Receiver CXR200 Setup manual CXR200, 7 |
Mopar Automobile Accessories 82215863Automobile Accessories PDF Manual 82215863, 5 |
Symphonic Remote Control 5600AOwner's manual for Symphonic 5600A Remote Control 5600A, 36 |