  • HP iPDU Intelligent, You cannot control what you cannot monitor. The new HP Intelligent Power Distribution Unit (iPDU) brings state of the art management and control to rack mounted power distribution units (PDU) to prevent over provisioning of power from restricting growth in your data center. Using the popular core and stick architecture of HP's Modular PDU line the HP Intelligent PDU provides monitoring of power consumption at the core, load segment, stick, and outlet level with unmatched precision and accuracy. Remote management is built in and even provides power cycle ability of individual outlet on the Intelligent Extension Bars.

  • HP iPDU Intelligent, Intelligent PDU 12 Outlet Core Unit 1-12. Load segment circuit breakers, one per IEC C19 26. Network connection (RJ-45) 13-24 IEC C19 Load segment outlets 27. LED Display Connection (DB-9) 25. Reset button (recessed) Intelligent PDU rear mount LED Display 1. Multi segment LED for amperage display 7. Scroll button for PDU Core Unit selection QuickSpecs HP Intelligent Power Distribution Unit (iPDU) Overview DA - 13650 Canada — Version 9 — March 7, 2014 Page 2

  • HP iPDU Intelligent, 2. Multi segment LED for PDU Core Unit identification 8 DB-9 for firmware updates 3. Multi segment LED for Load segment /Extension Bar identification number .9. DB-9 for connection to iPDU Core Unit 4. Multi segment LED for outlet identification number (Intelligent Extension bars only) 10. Recessed reset button 5. Scroll button for outlet selection (intelligent Extension bars only) 11. Alarm indicator 6. Scroll button for load segment/extension bar selection 12. Power Indicator Intelligent Extension Bar G2 for iPDU 1. Outlet UID indicator (blue LED) 5. Reset button 2

  • HP iPDU Intelligent, Standard Extension Bar for iPDU 1. 5 x IEC C13 outlets 3. Extension Bar UID indicator (blue LED) 2. Extension Bar power indicator (green LED) 4. Inlet cord with IEC C19 PLC connector to attach to iPDU Core Unit Models HP Intelligent Power Distribution Units (iPDU) iPDU Core Units NOTE: Each iPDU Core has 6 or 12 IEC C19 outlets and includes the LED display unit. NOTE: 6 outlet iPDU cores can be mounted in 1U or 0U locations. 12 outlets iPDU cores require 2U of rack space. HP 4.9kVA 24A Single Phase NA/JP Core Intelligent Modular Power Distribution Unit AF520A HP 8.3kVA 40A Single Phase NA/JP Core Intelligent Modular Power Distribution Unit AF521A HP 8.6kVA 24A Three Phase NA/JP Core Inte

  • HP iPDU Intelligent, NOTE: iPDU Kits include one Core Unit, LED Display, and 4 Standard (non-intelligent) Extension Bars. Total outlets would be 20 IEC C13 and 2 IEC C19 per kit. Additional Standard or Intelligent Extension bars can be added for a maximum of 30 IEC C13 outlets. Related Options iPDU Extension Bars HP 5xC13 Intelligent PDU Extension Bar G2 Kit AF547A NOTE: Intelligent Extensions Bars have individually monitored outlets that are also individually switchable for power cycling attached equipment. Each individual C13 outlet has Power Line Communi

  • HP iPDU Intelligent, Key Features 4.9kVA to 22kVA modular PDU core units Unique modular design architecture Up to 2 iPDU cores can be connected serially to work off of the same IP address or local display Small form factor with flexible mounting options 6 and 12 IEC C19 outlet models IEC C19 outlets accept optional iPDU Extension Bars or direct IEC C20 cable connections for HP BladeSystems Enclosures Automatic 100mS per outlet start delay on Intelligent Extension Bar User configurable restart delay by Intelligent Extension Bar outlet from 0-999 seconds

  • HP iPDU Intelligent, LED Displays show power draw (amperage) at the iPDU and can scroll through individual C19 outlet (load segments), and individual C13 outlets on the Intelligent Extension Bars. All PDU Extension Bars (overview) All iPDU Extension bars are sold in pairs. Each Extension bar has five IEC C13 outlets for connection to external equipment. Extension Bars can be mounted in the rear of the rack to ease cable management. Individual extension bars do not extend into the maintenance zone between RETMA rails at the rear of the rac

  • HP iPDU Intelligent, cables and Common Slot Platinum or Platinum Plus Power Supplies with PLC connectors on ProLiant DL servers or BLc Single Phase Intelligent Power Module equipped HP BladeSystem enclosures such as the c7000 Platinum Enclosures. Available in a wide range of lengths for C13-C14 jumper cables for ProLiant servers and C19-C20 jumper cables for BladeSystems c7000 Platinum Enclosures. If cable management arms are used a combination of 4.5ft and 6ft cables should be used to reach Intelligent Extension Bars mo

  • HP iPDU Intelligent, Redundancy and Grouping Two iPDUs can be paired to 2 other iPDUs in the same rack for redundancy. HP Intelligent Extension Bars connected to iPDU Cores enable outlet grouping on a single iPDU, outlet pairing on redundant iPDUs, and power redundancy verification. All based on UUID information obtained automatically. Paired iPDUs can recognize redundant Platinum Common Slot Power Supplies in ProLiant servers and ensure they are plugged into different iPDU Intelligent Extension bars on different iPDU cores for true power redundancy. Redundant Platinum Common Slot Power Supplies in ProLiant servers are automatically paired across multiple grouped iPDUs or grouped on a single iPDU to eas

  • PDS C13 Jumper Cable Guidelines Rack Depth Recommended C13-C14 cable length Left rear Right rear One meter or shorter with cable management arms 4.5ft (1.37m) 6ft (1.83m) One meter or shorter without cable management arms 2.5ft (0.76m) 2.5ft (0.76m) Deeper than one meter with cable management arms 6ft (1.83m) 8ft (2.43m) Deeper than one meter without cable management arms 4

  • Service and Support HP Technology Services HP Technology Services offers you consultants and support experts to solve your most complex infrastructure problems. We help keep your business running, boost availability and avoid downtime. Protect your business beyond warranty with HP Care Pack Services When you buy HP Options, it's also a good time to think abo

  • usage limitation has been exceeded. Coverage of the UPS battery is not included; standard warranty terms and conditions apply. The defective media retention service feature option applies only to Disk or eligible SSD/Flash Drives replaced by HP due to malfunction. It does not apply to any exchange of Disk or SSD/Flash Drives that have not failed. SSD/Flash Drives that are specified by HP a

  • HP iPDU Intelligent, Model Selection Matrix Intelligent PDU 6 outlet core only units 4.9 kVA iPDU Core 8.3 kVA iPDU Core 8.6 kVA iPDU Core 14.4kVA iPDU Core 17.3 kVA iPDU Core 7.3 kVA iPDU Core 11 kVA iPDU Core 22kVA iPDU Core Part Number AF520A AF521A AF522A AF533A AF523A AF525A AF526A AF527A Input Connection (Single Input) 3.6m input cord with L6- 30P 3.6m input cord with Non-NEMA Locking CS8265C, 50A 3.6m input cord with NEMA L15- 30P 3.6m input cord with Non-NEMA Locking CS8365C, 50A 3.6m input cord with IEC- 60309 3 pole, 4 wire 200- 240VAC 60A Waterproof 3.6m input cord with IEC 60309-32A Splashproof 3.6m in

  • HP iPDU Intelligent, 11.5 kVA iPDU Core 17.3 kVA iPDU Core 17.3 kVA iPDU Core Part Number AF900A AF901A AF902A Input Connection (Single Input) 3.6m input cord with NEMA L22- 20P 3.6m input cord with IEC 530P6S Splashproof 3.6m input cord with NEMA L22- 30P Facility power connection NEMA 22-20R 400-415 VAC 30A 3 Phase Wye IEC 530C6S or equivalent IEC60309 4 pole, 5 wire, 380- 400-415 VAC 30A 3 Phase Wye NEMA L22-30R 400-415 VAC, 30A 3 Phase Wye Output Connections on iPDU core 6 IEC 320 C-19 6 IEC 320 C-19 6 IEC 320 C-19 Exten

  • HP iPDU Intelligent, 4.9 kVA iPDU Kit 8.6 kVA iPDU Kit 7.3 kVA iPDU Kit Part Number AF531A AF532A AF534A Input Connection (Single Input) 3.6m input cord with L6-30P 3.6m input cord with NEMA L15- 30P 3.6m input cord with IEC 60309- 32A Splashproof Facility power connection NEMA L6-30R 200-208V NEMA L15-30R 208V 3 phase 3 pole 4 wire Delta IEC 332C6S, 332R6S, or equivalent IEC60309 2 pole, 3 wire, 200- 240VAC, 32A Output Connections on iPDU core 6 IEC 320 C-19 6 IEC 320 C-19 6 IEC 320 C-19 Extension Bars 4 Standard Extension Bars w/ 5x C13 each 4 Standard Extension Bars w/ 5x C13 each 4

  • HP iPDU Intelligent, Shipping Weight 6 outlet: 20.2 lb (9.16 kg), 12 outlet: 36.4 lb (16.51 kg) Operating Temperature 50° to 122° F (10° to 50° C) Operating Relative Humidity (%) 10% to 90% Operating Elevation 0 to 10,000 ft (0 to 3048 m) Storage Temperature -4° to 140° F (-20° to 60° C) Storage Relative Humidity (%) 5% to 95% Storage Elevation 0 to 30,000 ft (0 to 9144 m) Input Plug Length 142 inches (360.7 cm) Conformance Standards UL, CUL, CE, NOM, D - 16A and 40A models UL, CUL, NOM - 24A High and Low voltage models CE, D - 32A model Mechanical Dimensions (WxHxD), 6 outlet cores 17.5 x 1.62 x

  • HP iPDU Intelligent, Environment-friendly Products and Approach End-of-life Management and Recycling Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling programs in many geographic areas. For trade-in information, please go to: http://www.hp.com/go/green . To recycle your product, please go to: http://www.hp.com/go/green or contact your nearest HP sales office. Products returned to HP will be recycled, recovered or disposed of in a responsible manner. The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This inform

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Piper Archer III PA-28-181 Handbook piper/archer-iii-pa-28-181-ULW.pdf 08 Apr 2024 317
2 Smarthome 888R25 Operation & user’s manual smarthome/888r25-581.pdf 15 Aug 2023 5 0.76 Mb
3 BenQ MH74I Quick start manual benq/mh74i-Q22.pdf 06 Mar 2024 33
4 Russell Hobbs RH60EH401B Instruction manual russell-hobbs/rh60eh401b-927.pdf 07 Jul 2023 24
5 Omnitronic L-SERIES Operation & user’s manual omnitronic/l-series-715.pdf 26 Sep 2023 44
6 Festo VZWF-...-M22C series Operating instructions festo/vzwf-m22c-series-976.pdf 20 Aug 2023 2

Similar Resources:

  • Huawei

    PDU8000 Series

    (2 pages)
    PDU8000 Power Distribution Box-T Quick GuidePDU8000 配电箱-T快速指南To ensure safety of humans and the equipment, pay attention to the safety symbols on the equipment and all the safety instructions in this document. The "NOTE", "CAUTION", and "WARNING" marks in this document do not represent all the safety instructions. …
  • Rockwell Automation

    Allen-Bradley B Series

    (2 pages)
    Installation Instructions 1606-XLS960BUFFER SER B Buffer Module 24V, 40A PU-425.015.38-xxC EN Before operating this device, please read this manual thoroughly and retain this manual for future reference! This device may only be installed and put into operation by qualified personnel. If damage or malfunction should occur during ope …
  • Vertiv

    Knürr DI-Strip Rack PDU

    (26 pages)
    Knürr® DI-Strip Rack PDU und Serimat – SteckdosenleistenKnürr® DI-Strip Rack PDU and Serimat– Power Distribution UnitsKnürr® DI-Strip Rack PDU et Serimat – Réglettes de prises …
  • Raytheon

    138-118

    (65 pages)
    Raytheon Marine GmbHHigh Seas ProductsPostfach 1166D -- 24100 KielGermanyTel+49--431--3019--0Fax+49--431--3019--291Email [email protected] Edition: November 21, 2003Revision: Feb. 14, 2004Revision: Feb. 23, 2004DISTRIBUTION UNITType 138--1181 Description2 Installation …
  • LDG

    Multi-DC

    (6 pages)
    Multi-DC Power Distribution Box LDG Electronics 1445 Parran Road, PO Box 48 St. Leonard MD 20685-2903 USA Phone: 410-586-2177 Fax: 410-586-8475 [email protected] www.ldgelectronics.com …
  • ABB

    System pro E power

    (2 pages)
    System pro E powerInstruction handbookManuale istruzioniMontageanleitungInstructions de montageManuale de instruccionesInstrukcja montażowaWarning! Installation by person with electrotechnical expertise only.Lebensgefahr durch elektrischen Strom!Nur Elektrofachkräfte und elektrotechnischunterwiesene Personen dürfen die im folgendenbeschriebenen Arbeiten …

Comments, Questions and Opinions: