  • HP 710B, CAUTION I I VOLTAGES WHICH ARE DANGEROUS TO LIFE ARE PRESENT -- AT THE TERMINALS AND WITHIN THIS INSTRUMENT I__--- ---- CAUTION IF THIS INSTRUMENT IS EQUIPPED WITH 6L6 METAL TUBES --_I_-- --__- A DANGEROUS VOLTAGE MAY BE PRESENT BETWEEN THE - -- - -______p. -. _----- 6L6 METAL TUBE SHIELDS I AND THE CHASSIS. -____c G enera1 Descriotion I Model 710B Power Supply is an excellent source of direct current power for laboratory and production use. vo%tage and applied

  • HP 710B, INS T RU C TIONS MODEL '7lOB POWER SUPPLY Soecifications 0 9 N 4 14 a 0 Ih 4 Regulated Output Ratings: -- Voltage: 100 to 360 volts DC. Current: 0 to '75 MA. Maximum Output Ratings: Current: 100 MA. Filament Supply: 6.3 volts AC COT. at 5A. Regulation: Approximately 1% for operating conditions within the Regulated Output Ratings and for line voltage variations of 105 to 125 volts /210 to 250 volts 0 Noise and Hum: Total noise and hum is less than ., 005 volts for operating conditions with- in regulated Output Ratings. 1-- . ~ Required Power Source: Voltage: 105 to 125 volts/210 to 250 volts, F

  • HP 710B, After the instrument is unpacked, it should be inspected for damage re- ceived in transit. lined in the "Claim for Damage in Shipment" page at the back of this instruction book. If any shipping damage is found, follow the procedure out- Controls and Terminals -- DC ON - This switch controls the direct current supplied to the DC binding posts and indicator lamp which is lighted while there is voltage on these binding posts. AC ON - This switch controls the power supplied to the instrumen

  • HP 710B, Connect the output terminals of the Model 710B to the load and connect the power cable to a 105-125 volts supply. AC ON, and allow the instrument to warm-up for about two minutes. the VOLTAGE CONTROL for the desired voltage. Turn the toggle switch to DC ON, Adjust The Model 710B may be operated with either terminal of the DC output grourded. Anyone of the three 6.3 terminals may be ground. The instrument may be operated with th? DC output ungrounded. usually results in a slightly higher hum level Ixlt this may be corrected by reversing the power cable plu

  • HP 710B, TABLE OF REPLACEABLE PARTS Circuit Ref. c1, a, c4, c5 C2 ab C6 C7 abc C8 Ri, R2, R3, R4 R5, R6 R7 R8, R9, R14 R10 R11 R12 R13, R18 R15 Rlb I *See 'Uat 0 4a -hp - Mfr. * SL Mfrs. De s cription Stock No. Designation Capacitor: fixed, electrolytic , 18-40 A Capacitor: fixed, electrolytic, 18 -42 X Capacitor: fixed, paper, 16- 1 A 40 pi, 450 vdcw AEF - 1 rt~3" 40 ppf, 450 vdcw FPQ-444 1 pf, 600 vdcw Type: P688 Capacitor: fixed, electrolytic, 18-8 HP 10, 10,40 pf, 150 vdcw Capacitor: fixed, electrolytic, 18-10 X 10 pf,

  • HP 710B, Circuit Ref. ~. -~~ ~- R17, R22 R19 R2 0 R2 1 R23, R24 R2 5 R2 6 CR1 F1 F1 F2 tl, I2 L1 51 52 ri r2 ?1 TABLE OF REPLACEABLE PARTS Description Resistor: fixed, wirewound, 30,000 ohms, -+lOo/oo, 10 W Resistor: fixed, composition, 1000 ohms, +lo%, 1 W Re si s tor: fixed, composition, 150Q ohms, +lo%, 1 W Resistor: fixed, composition, 18 ohms, +lo%, 1 W Re si s tor: factory adjustment Resistor: fixed, composition, 4700 ohms, +10%, 1 W Resistor: fixed, composition, 12

  • HP 710B, Circuit Ref. v1 v2 v3 vJ4 v5 TABLE OF REPLACEABLE PARTS De s cription Tube: 5U4G Tube: 6L6G Tube: 6L6G Tube: 6SJ7 Tube: VR75 -hp - Stock No. 212-5U4C 2 12-6L6c 212-6L6G 212 - 6s J7 212 -VR75 Mfr. * dr Mfrs. Des ignrtion zz zz zz zz zz *See "List of Manufacturers Code Letters For Replaceable Parts Table. -6-

  • LIST OF MANUFACTURERS CODE LETTERS FOR REPLACEABLE PARTS TABLE Code Letter Manufacturer A Aerovox Corp. B Allen-B radley Co. C Amperite Co. D E F G H I J K L M N 0 P HP Q R S T U V W X Y Z AA BB cc DD EE FF GG HH I1 JJ zz Arrow, Hart and Hegeman Bussman Manufacturing Co. Carborundum Co. C en t r a1 ab Cinch Manufacturing Co. Clarostat Manufactu

  • CLAIM FOR DAMAGE IN SHIPMENT The instrument should be tested as soon as it is received. If it fails to operate properly, or is damaged in any way, a claim should be filed with the carrier. A full report of the damage should be obtained by the claim agent, and this report should be forwarded to us. We will then advise you of the dis-

Related Products and Documents (Power Supply):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 VDO CD 2202 - Operation & user’s manual vdo/cd-2202-W41.pdf 08 Feb 2024 17 1.99 Mb
2 Nokia 8250 Software manual nokia/8250-J2M.pdf 18 Jun 2023 13
3 Comelit 49807 Operation & user’s manual comelit/49807-M1B.pdf 01 Nov 2023 36
4 Shure 515SBGX Operation & user’s manual shure/515sbgx-953.pdf 02 Jan 2023 2 1.32 Mb
5 Channel Vision 6144 Instructions manual channel-vision/6144-CAP.pdf 08 Aug 2022 8 0.18 Mb
6 Cisco DMRW1000 Quick installation manual cisco/dmrw1000-F5S.pdf 02 Jan 2024 32 7.8 Mb

Similar Resources:

  • Himax

    CLT-50

    (2 pages)
    All units have an internal circuit breaker protecting the DC output. If the breaker opens, turn the power off and wait a few minutes to allow the circuit breaker to reset. If the breaker is continually opening it could mean you have a problem with the tool or the tool power cord, the power supply or have selected the wrong screwdriver or power supply for th …
  • Ultra Power

    UP1200W

    (2 pages)
    INSTRUCTION MANUALTo protect the power supply during a lightning storm or when it is left unattended and unused for long periods of time, unplug it from the AC outlet. This will prevent damage to the power supply from lightning and power surges.Unplug the power supply from the outlet before attempting any maintenance or cleaning. Do not use liquid or aeroso …
  • Altronix

    AL175UL

    (4 pages)
    AL175UL - 1 -AL175ULAccess Control Power Supply/ChargerOverview:AL175UL is a power-limited power supply/charger that converts 115VAC / 60Hz input into two individually PTC pro-tected auto-resettable 12VDC or 24VDC outputs (see specifications). It is intended for use in applications requiring UL Listing for Access Control (UL294) and applications requiring …
  • Rolls

    PS16

    (2 pages)
    Owners ManualRolls CorporationSalt Lake City, UT6/02 LIMITED WARRANTYThis product is warranted to the original consumer purchaser to befree from defects in materials and workmanship under normal installation, useand service for a period of one (1) year from the date of purchase as shown onthe purchaser’s receipt.The obligation of Rolls Corporation under th …
  • INFOSEC UPS SYSTEM

    S8

    (10 pages)
    Notice d'utilisation ______________________________ 5 User Guide _____________________________________ 6 Gebruikshandleiding ____________________________ 7 Uživatelská příručka _____________________________ 8 Používateľská príručka ___________________________ 9 _____________________________________ 10 …
  • Accel Instruments

    TS200

    (2 pages)
    Quick Start GuideBattery SimulatorStep 1-A: Plug in the AC power cord (not shown)Step 1-B: Turn on the TS200 by press the LINE buttonStep 1-C: Enable the output by press the ON/OFF buttonStep 2: Turn the OFFSET knob to set the simulated battery voltage (e.g. 3.8V)BATTERY CHARGER1.01AOptional DMM forMeasure CurrentStep 3: Connect the battery charger …