Hunter ColorFlex 13-1 Operation & User’s Manual

Hunter ColorFlex 13-1 Manual Online:

4.35, 2200 votes
Hunter ColorFlex 13-1 User Manual
Hunter ColorFlex 13-1 User Guide
Hunter ColorFlex 13-1 Online Manual

Text of Hunter ColorFlex 13-1 User Guide:

  • Hunter ColorFlex 13-1, 07/02 ColorFlex 13-1 ColorFlex    Notice: Use of this equipment in a manner not specified by the manufacturer may impair the protection afforded by the equipment. The ColorFlex system consists of a ColorFlex optical sensor and an IBM-compatible computer composed of the system unit, monitor, keyboard, and mouse. The computer may have been user- provided or purchased with the sensor and software. A printer may also be used with the system. The ColorFlex Sensor The ColorFlex spectrocolorimeter is a versatile, compact color measurement instrument that can be used on

  • Hunter ColorFlex 13-1, 07/02 ColorFlex 13-3 Accessories The following accessories are provided with the ColorFlex and can be found in the standards box. • Black glass - placed at the sample port during standardization of 45°/0° instruments. • Light trap - placed at the sample port during standardization of diffuse/8° instruments. • White calibrated tile - placed at the sample port during standardization. • Green tile - used to check instrument performance. Use of the green tile is described on page 24-3. • Standards care card - gives instructions o

  • Hunter ColorFlex 13-1, 13-4 ColorFlex 07/02 Options and Sample Devices Any or all of the following options and sample devices may be included. HunterLab part numbers are included for your convenience. • Sample clamp/port-forward stand (HL#D02-1010-459), • Port inserts [45°/0° instruments only] (various part numbers), • Bar code reader kit (HL#D02-1010-715), • 2.5-inch glass sample cup (HL#04-7209-00), • Sample cup opaque cover (HL#04-4000-00), • Sample cup port plate [45°/0° instruments only] (HL#04-6622-00), • Ring and disk set [45°/0° instruments only] (HL#02-4579-00), �

  • Hunter ColorFlex 13-1, 07/02 ColorFlex 13-5 Sample Clamp/Port-Forward Stand The port-forward stand holds the instrument securely in the port-forward position and the sample clamp allows samples to be held flat at the sample port when the instrument is in this orientation. To attach the stand to the ColorFlex, lay the instrument on its side and install the two screws through the stand into the bottom of the instrument using the Allen wrench provided. To use the sample clamp, pull the spring-loaded clamp away from the sample port, insert the sample, and gently release the clamp. Port Inserts (45°/0° instruments only) Port inserts with various-sized opening

  • 13-6 ColorFlex 07/02 Bar Code Reader Kit The bar code reader attaches to the communications port of the ColorFlex and allows input of a 24-character bar code ID. An AC adapter is also provided. Installing the Bar Code Reader The ColorFlex is capable of reading and storing sample IDs from a bar code reader. The bar code reader, cable, and AC power supply may be purchased as optional eq

  • Hunter ColorFlex 13-1, 07/02 ColorFlex 13-7 To operate the bar code scanner, hold the wand at a slight angle (10 to 30 degrees) from vertical. Place the wand on the page either to the right or left of the code to be scanned and move the wand at a steady speed across the code to the other side. Do not stop until the bar code is completely passed over. The red light at the tip of the bar code reader will blink twice when scanning the ENTER code and will blink once for all other codes when the codes have been scanned correctly. You must look for the blink for each code scanned. If the reader does not blink, try again. If you miss seeing the blink, or are unsure if it blinked or not, scan the EXIT code and

  • Hunter ColorFlex 13-1, 13-8 ColorFlex 07/02 Note: If you do not use the autostore function, then be sure to manually log each reading by pressing the Up Arrow/Print key after entering the sample ID from the bar code reader. 2.5-inch Glass Sample Cup The sample cup is ideal for the analysis of powders, granules, pellets, and translucent samples. It is recommended for use with the instrument in the port-up position. The cup can be filled with the desired sample and placed at the measurement port so that the sample is measured through the glass bottom of the cup. Sample Cup Opaque Cover The opaque cover provides a light trap to exclude the interference of external ligh

  • 07/02 ColorFlex 13-9 opaque cover. Measure the sample at the sample port through the glass bottom of the sample cup with the instrument in the port-up orientation. Orange Juice Tube Holder (45°/0° instruments only) This holder is designed to allow the viewing of a 1-inch glass test tube of orange juice by the instrument through a viewed area equivalent to that of t

  • Hunter ColorFlex 13-1, 13-10 ColorFlex 07/02 Calculations for the citrus scales are given in Appendix A. OJ4 Orange Juice Standard This option provides an uncalibrated plastic OJ4 standard for creating a new instrument hitch or checking the current instrument hitch to the United States Department of Agriculture’s (USDA) standards. This standard is also available with USDA calibration for an additional fee. When a citrus scale is to be used, read the OJ4 standard and hitch the instrument to the XYZ values given on the standard label. Save the standard and recall it to rehitch the instrument whenever citrus scales are to be measured. The standard is intended for use with the

  • Hunter ColorFlex 13-1, 07/02 ColorFlex 13-11 Skein Holder (45°/0° instruments only) This is a device for measuring yarn skeins. Wind the yarn around the skein holder in multiple taut layers until it is effectively opaque and is as flat as possible. Secure it in place with the detachable arms on the sides of the skein holder. Place the skein holder at the sample port and back it with the sample clamp or a white backing tile to provide a consistent background and pressure. Make several measurements of the skein, rotating the holder 90° be

  • Hunter ColorFlex 13-1, 13-12 ColorFlex 07/02 Foot Switch Pressing the foot switch performs the same function as the Read button on the keypad. A pre-programmed sequence of steps can be carried out without input from the computer keyboard or mouse. See the “Toolbar” section of the Configure chapter for instructions. Install the foot switch by plugging it into the round connector on the back of the ColorFlex. (See the picture on page 13-13.) External Serial Printer The external serial printer connects to the serial port of the ColorFlex and prints the setup data when the Read key is pressed and held or the measurement data when th

  • Hunter ColorFlex 13-1, 07/02 ColorFlex 13-13 Installation The following instructions guide you through the initial installation of your ColorFlex system. 1. Unpack all cartons and remove wrappings and cable ties. Inspect for damage and notify the carrier and HunterLab immediately if any is discovered. Save the packing materials in case it becomes necessary to return the instrument to the factory. 2. Place the ColorFlex on a flat, stable surface near an electrical outlet. 3. Connect the jack connector of the AC adapter to the jack acceptor on the lef

  • Hunter ColorFlex 13-1, 13-14 ColorFlex 07/02 Standardization Standardization on a ColorFlex model with 45°/0° geometry requires reading of the black glass and white tile. Standardization on a diffuse/8° ColorFlex requires you to read both the light trap and the white tile. Standardizing a diffuse ColorFlex using the light trap Standardizing a 45°/0° ColorFlex using the black glass

  • 07/02 ColorFlex 13-15 Standardization can be done through the software or directly through the ColorFlex firmware. More detailed information about your ColorFlex sensor and its standardization is given in its separate ColorFlex User's Guide and in the Sensor chapter of this manual. It is recommended that the instrument be standardized at least once every eight hours. Then you ma

  • Hunter ColorFlex 13-1, 13-16 ColorFlex 07/02 Maintenance This section outlines the parts of the sensor you must maintain in order for the instrument to function properly. More detailed information about your ColorFlex sensor is given in its separate User's Guide. Notice: Do not disassemble the instrument and attempt to clean the optical components. Do not open the instrument or remove any covers except using the instructions given in this User’s Manual or under the direction of HunterLab Customer Support. Replacing the Lamp Lamp replacement requires a trained technician. Contact HunterLab Customer Support to a

  • Hunter ColorFlex 13-1, 07/02 ColorFlex 13-17 Archiving Setups All ninety-nine setups can be stored in non-volatile memory by choosing “Archive Setups” from the ColorFlex menu. When this procedure is performed, all setups will then be stored in non-volatile memory and will be safeguarded from loss due to memory failure. It is recommended that you store your setups in non-volatile memory on a regular basis. This will protect your setups should you experience an unforeseen memory loss. If you create additional setups or change existing setups and wish t

  • 13-18 ColorFlex 07/02 Specifications For best performance, your instrument should be placed where there is ample work space with medium or subdued illumination and no drafts. For optimum results, a clean, air-conditioned area is recommended with a relative noncondensing humidity of 5-85% and relatively constant temperature not exceeding 110°F (43°C). For specification performan

  • Hunter ColorFlex 13-1, 07/02 ColorFlex 13-19 Baud rate from 300 to 57600 No parity 8 data bits 1 stop bit. Your output device must be configured in the same way in order to communicate with ColorFlex. Note that Universal Software’s maximum baud rate is 19200. Note: Several baud rates are available with ColorFlex. Be sure to change the INSTRUMENT SETUP of ColorFlex to agree with the baud rate selected for your output device. Handshake Output from the ColorFlex serial port is controlled by XON/XOFF handshaking. Data output is stopped when the output device sends an XOFF character to ColorFlex. Data flow begins again when ColorFlex receives an XON character. Conditions of Illumination and View

  • Hunter ColorFlex 13-1, 13-20 ColorFlex 07/02 The instrument serial port ground connection is referenced to the instrument's internal frame and safety ground. Before connecting the communication cable to the instrument serial port, apply power to the instrument and the host computer. Check the ground potential (voltage) between the serial port ground pins on the computer and the instrument. The ground connection is pin 5 on DB-9 connectors and pin 7 on DB-25 connectors. Voltages in excess of 5VAC at 110V input power, or in excess of 10VAC at 220V input power may indicate a difference in ground wiring and can damage the instrument and/or the computer. Check the wiring and take other steps as needed to redu

  • Hunter ColorFlex 13-1, 07/02 ColorFlex 13-21 7. When all readings are complete, examine the average DE* value. The instrument passes the repeatability test as long as the average DE* value is less than or equal to 0.04. Contact HunterLab Customer Support as described on page 25-6 if the instrument fails the repeatability test. Note: Performance specifications are subject to change without notice. Regulatory Notice A copy of the Declaration of Conformity according to ISO/IEC Guide 22 and EN 45014 follows on the next page.

  • Hunter ColorFlex 13-1, 13-22 ColorFlex 07/02 DECLARATION OF CONFORMITY according to ISO/IEC Guide 22 and EN 45014 Manufacturer's Name: Hunter Associates Laboratory, Inc. Manufacturer's Address: 11491 Sunset Hills Road Reston, Virginia U.S.A. 20190 Declares that the Product: Product Name: ColorFlex Model: CFLX-DIFF, CFLX-45, CFLX-DIFF-2, CFLX-45-2 Conforms to the following Product Specifications: EMC: EN55011 / CISPR 11 (1990-09) Class A Group 1 EN50081-1:1992 EN50082-1:1992 EN55011:1994, Class A IEC 801-2 (1984), 8 KV IEC 801-3 (1984), 3 V/m (27-500 MHz) IEC

  • Hunter ColorFlex 13-1, 07/02 ColorFlex 13-23 Color Measurement Notes The ColorFlex spectrocolorimeter is a versatile color measurement instrument that can be used on products of virtually any size, in industries as diverse as paint and textiles. Because of its compact design, it can be used to measure objects that would be difficult to position at the sample port of a larger color instrument. Sample measurement methods can be found on the world wide web! Visit www.hunterlab.com to see if an illustrated method is available for your application. Measuring the co

Related Products and Documents (Printer):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Bosch Shimano Nexus Di2 Original instructions manual bosch/shimano-nexus-di2-JEO.pdf 10 Sep 2023 20
2 Tektronix 2215A Instruction manual tektronix/2215a-4KQ.pdf 19 Oct 2023 206
3 Patton electronics 510 Operation & user’s manual patton-electronics/510-CQX.pdf 26 Jul 2022 3 0.02 Mb
4 Leviton RZCS4 Installation instructions leviton/rzcs4-957.pdf 06 Mar 2024 2
5 TnB SPCAMHD2 Instructions manual tnb/spcamhd2-XN7.pdf 05 Jan 2024 72
6 Silvercrest SFB 10.1 A1 Operating manual silvercrest/sfb-10-1-a1-5MF.pdf 20 Jun 2022 86 2.16 Mb

Similar Resources:

  • MIMAKI

    CG-60AR

    (8 pages)
    CG-60AR [Option]- 1 -© 2021 MIMAKI ENGINEERING CO.,LTD.Installation instructions for the legsThis manual explains how to assemble the legs with the main unit. Be sure to read this manual before assembling.AccessoriesIf there is a shortage of parts or a problem, please contact your local distributor or MIMAKI sales office.How to tighten the screws1Use hex wr …
  • Panasonic

    KXF-1E4C

    (118 pages)
    Operating InstructionsModel No.Maintenance ManualKXF-1E4CKXF-1F4CThank you for purchasing SP28P, the high speed screen printer.Before placing the machine in service, be sure to read the instruction manual forproper usage.After that, store it carefully and it if necessary.1E4C-E-MMAB-0013High Speed Screen Printer SP28P …
  • Dymo

    LetraTag XR

    (36 pages)
    LetraTag XRwww.dy mo.c omInstructions for Use …………… Page 4 Használati útmutató…………… Page 14 Kullanım talimatları …………… Page 24LT XR UK-HUN-TR.indd 1 14-02-2006 09:35:20 …
  • Lexmark

    CS310 Series

    (2 pages)
    The Lexmark CS310 Series color laser printer performs like no other. With PANTONE® color matching and other features typically found only on larger, higher-end systems, this affordable desktop system helps your company shine with professional results. Want 2-sided printing capabilities? Get the CS310dn.Color Eco-ModeColor 2.4" LCD StandardPagesUp to 35 …
  • Epson

    AccuSuite 11880 Series

    (13 pages)
    Epson Stylus® Pro 11880 QUICK REFERENCE GUIDEPrinted in USACPD-24469Control Panel Lights and ButtonsAuto take-up reel backward buttonPaper Feed down buttonPaper source or cut buttonPower buttonPaper Feed up buttonPause or reset button and lightInk lightInk cartridge gaugesPaper lightEnter or barcode buttonMenu or cleaning buttonMaintenance tank gaugesPowe …
  • HP

    Color LaserJet 5500

    (2 pages)
    hp color LaserJet 5500printer serieshp color LaserJet 5500/n/dn/dtn/hdnMake a sound investment in this high-speed, wide format colour laser printer and gain real businessbenefits at a great price. Simple to use and flexible enough to meet every workgroup’s demands, you can create impressive colour documents easily.For demanding, versatile workgroups in the …

Comments, Questions and Opinions: