  • IOGear GIC704SR5W6, 3 Table of Contents Caution 4 Introduction 5 Features 6 Package Contents 7 What Is RAID? 8 Installation Procedure 11 Software Installation 18 Federal Communications Commission (FCC) Statement 22 CE Statement 24 Limited Warranty 25 Contact 26

  • IOGear GIC704SR5W6, 4 Caution • Before installation of the controller card, we recommend that users study this manual fi rst. This RAID manual has more information on RAID architecture, RAID features, RAID installation, RAID settings and Management software for the RAID5 GUI (Graphical User Interface). • Windows Device Manager cannot recognize hard drives without the correct RAID settings in place. • The working data on your existing hard drive may NOT work when you migrate it to a RAID Host Card confi guration. • After driver installation you can install the SATARAID5 GUI for RAID management. Befor

  • IOGear GIC704SR5W6, 5 Introduction The board offers the ability to upgrade your desktop computer to RAID 5, RAID 0+1, RAID 0, or RAID 1 as well as JBOD. The board can control four independent Serial ATA channels. Each channel has its own Serial ATA bus and will support one Serial ATA device. The board supports Serial ATA Generation 1 transfer rates of 1.5 Gb/s (150 MB/s).

  • IOGear GIC704SR5W6, 6 Features PCI Interface Compliant with PCI Specifi cations, Revision 2.2.• Integrated PCI DMA engines.• 32 bit, 33/66MHz fully compliant PCI host interface.• High Speed Serial ATA Interface Four high speed Serial ATA interface ports, each supporting 1st generation Serial ATA data rates • (1.5Gb/s). RAID 5 (Distributed Parity RAID) has Highest Read data transaction rate and Good aggregate transfer rate.• Provides RAID 0 (Stripping) to greatly increase the performance of data transfer by simultaneously writing • d

  • 8 RAID - Redundant Array of Independent Disks RAID technology manages multiple disk drives to enhance I/O performance and provide redundancy in order to withstand the failure of any individual drive, without loss of data. Disk Striping (RAID 0) Striping is a performance-oriented, non-redundant data mapping technique. While Striping is discussed as a RAID Set type, it actually do

  • IOGear GIC704SR5W6, 9 Mirrored-Striping (RAID 0+1 also known as RAID 10) A Mirrored-Striping Set does just what it says, combining both Striping and Mirroring technologies to pro- vide both the performance enhancements that come from Striping and the data availability and integrity that comes from Mirroring. When data is written to a Mirrored-Striped Set, instead of creating just one virtual disk as Striping would do, a second Mirrored virtual disk is created as well. Parity RAID (RAID 5) Parity or RAID 5 adds fa

  • IOGear GIC704SR5W6, 10 Just a Bunch of Disks (JBOD/Contiguous) JBOD (also known as Contiguous) means a logical drive that can either be an entire disk drive or a segment of a single disk drive. For this card, the JBOD function only supports one disk. JBOD here is a Contiguous confi guration option when using the “Create RAID Group” within the SATARAID5 Manager Utility.

  • IOGear GIC704SR5W6, 11 1. Power down the computer system. 2. Insert the Host card into an available bus slot. 3. Power on the computer system. 4. Install drivers for the device. 5. Remove all existing SATARAID GUIs (or Java SATARAID GUIs) to ensure your new SATARAID5 GUI installs and functions properly. 6. Install the SATARAID5 GUI. 7. Power down the computer system once again. 8. Connect Hard Drives to the proper SATA Ports. 9. Power on the computer system once again. 10. If you connect any used HDDs to the SATA Ports, Press CTRL+S or F4 and delete any RAID settings that may be on the drives when using the BIOS bo

  • 12 11. Use the SATARAID5 Manager GUI to confi gure your RAID settings. If using 1 Disk, please select “Concatenate” or “Contiguous” settings only. If using 2 Disks, do NOT select “Parity RAID” or “Mirrored Stripe” settings. If using 3 Disks, do NOT select the “Mirrored Stripe” setting. 12. Open “Task Manager” to make sure the RAID setu

  • IOGear GIC704SR5W6, 13 BIOS (RAID Settings) Creating and deleting RAID sets is a function found in the BIOS. During boot up, the RAID setting message will appear and pause for a few moments to allow the user access to its settings. The board will act as a normal NON-RAID card when the BIOS does not have it confi gured for RAID. If you’re using traditional parallel ATA HDDs, make sure your hard drives are set to master mode before accessing the RAID settings. Creating Striped Sets (RAID 0) 1. As the BIOS boots, Press CTRL+S or F4 to enter the RAID bios utility. 2. Select Create RAID set. Press Enter. 3. Select RAID 0

  • IOGear GIC704SR5W6, 14 Creating Mirrored Sets (RAID 1) 1. As the BIOS boots, Press CTRL+S or F4 to enter the RAID bios utility. 2. Select Create RAID set. Press Enter. 3. Select RAID 1 then press Enter. 4. Select Auto confi guration. Press Enter. 5. Press Y to save your settings. 6. Press CTRL+E and then press Y to exit the setup. 7. Continue with conventional Fdisk and Format steps to prepare the hard drives. 8. Your RAID hardware confi guration is complete. Proceed to software installation section.

  • IOGear GIC704SR5W6, 15 Creating a Mirrored-Striped Set (RAID 10) 1. As the BIOS boots, press CTRL+S or F4 to enter the RAID bios utility. 2. Select Create RAID set. Press F2. 3. Select RAID 10 then press Enter. 4. Select Auto confi guration. Press Enter. 5. Press Y and then press ESC to exit the setup. 7. Continue with conventional Fdisk and Format steps to prepare the hard drives. 8. Your RAID hardware confi guration is complete. Proceed to software installation section. Creating Parity RAID (RAID 5) 1. As the BIOS boots, Press CTRL+S or F4 to enter the RAID bios utility. 2. Select Create RAID set. Press Enter. 3. Select RAID 5 t

  • IOGear GIC704SR5W6, 16 Creating JBOD Sets 1. As the BIOS boots, Press CTRL+S or F4 to enter the RAID bios utility. 2. Select Create RAID set. Press Enter. 3. Select JBOD (Single) then press Enter. 4. Select JBOD Drives. Press Enter. 5. Select RAID size. Press Enter. 6. Press Y to save your settings. Creating Spare Drive 1. As the BIOS boots, Press CTRL+S or F4 to enter the RAID bios utility. 2. Select Create RAID set. Press Enter. 3. Select Spare Drive then press Enter. 4. Select Spare Drives. Press Enter. 5. Select RAID size. Press Enter. 6. Press Y to save your settings.

  • IOGear GIC704SR5W6, 17 Deleting RAID Sets 1. As the BIOS boots, Press CTRL+S or F4 to enter the RAID bios utility. 2. Select Delete RAID set. Press Enter. 3. Answer Y to remove the RAID set. If the RAID set being deleted is a Striped, then all of the data will be lost. If the set being deleted is a Mirrored set, then the data will remain intact and accessible on both drive sets. Rebuilding Mirrored Sets (RAID 1) 1. After replacing the failed hard drives boot the BIOS, Press CTRL+S or F4 to enter the RAID bios utility. 2. Select Rebuild RAID 1 set.

  • IOGear GIC704SR5W6, 18 Windows XP Fresh Installation 1. Power off the system. Insert the controller card into a PCI slot and connect the hard drives to the controller card. Power up the system. 2. Put your Windows XP CD into the CD-ROM/DVD drive. 3. Press F6 for third party SCSI or driver installation. Press ‘S’ when setup asks if you want to specify an additional device. Press ‘Enter’ and select ‘[CD Drive Letter]:\RAID5 SATA_4Port \SiI3114\ Win XP_2000_2003\Driver’. 4. Press ‘Enter’ to continue. 5. Follow the setup instructions to select your choice for partitions and

  • 19 Windows XP Existing Installation 1. Power off the system. Insert the controller card into a PCI slot and connect the hard drives to the control- ler card. Power up the system. 2. During OS boot up, Windows will display the ‘Found New Hardware Wizard’. Click ‘Next’. 3. Select ‘Install from a list or specifi c location (Advanced)’ and Click ‘Next’.

  • IOGear GIC704SR5W6, 20 4. Insert the Driver CD in your CD-ROM/DVD drive, check Specify a location, uncheck the other boxes, click Next, type in your CD-ROM/DVD Drive Letter and Click Browse. 5. Specify the following location: [CD Drive Letter]:\RAID5 SATA_4Port\SiI3114\Win XP_2000_2003\Driver. Select Open then click OK. 6. When the wizard indicates that it found a driver for the device click ‘Next’. 7. The wizard will now copy the required fi les to the system. After installation the wizard will display a completion dialog, click ‘Finish’ to exit the wizard.

  • IOGear GIC704SR5W6, 21 Verifying controller installation 1. Right click on the ‘My Computer’ icon and select ‘Properties’. Left click on the ‘Hardware’ tab then select the ‘Device Manager’ button. 2. Double click on ‘SCSI and RAID Controllers’, If there is no yellow ‘!’ or ‘?’ in front of the ‘Silicon Image SiI 3114 SoftRAID5 Controller’, the driver is functioning properly.

  • 22 Federal Communications Commission (FCC) Statement Federal Communications Commission (FCC) Statement 15.21 You are cautioned that changes or modifi cations not expressly approved by the part responsible for compliance could void the user’s authority to operate the equipment. 15.105(b) This equipment has been tested and found to comply with the limits for a Class B digit

  • IOGear GIC704SR5W6, 23 - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: 1. this device may not cause interference and 2. this device must accept any interference, including interference that may cause undesired operation of the device. FCC RF Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled enviro

  • IOGear GIC704SR5W6, 24 This device has been tested and found to comply with the requirements set up in the council directive on the approximation of the law of member states relating to EMC Directive 89/336/EEC, Low Voltage Directive 73/23/EEC and R&TTE Directive 99/5/EC. CE Statement

  • IOGear GIC704SR5W6, 25 The manufacturer, IOGEAR, makes NO warranty or representation, whether express or implied, regarding the contents, use or suitability of this software, disk or documentation. IOGEAR specifi cally disclaims any and all warranties regarding the quality and performance of this software, disk or documentation including, but not limited to the implied warranty of merchantability and implied warranty of fi tness for a particular purpose. IOGEAR shall not be responsible or liable for property damage, loss of use, interruption of business, lost profi ts, lost data or other consequential, punitive or special damages, however caused and however alleged. IOGEAR reserves the right to revi

  • 26 Contact Toll Free: (866) 9-IOGEAR Phone: (949) 453-8782 23 Hubble Irvine, CA 92618 USA www.iogear.com [email protected] ©2007 IOGEAR. All Rights Reserved. PART NO. M0560 IOGEAR, the IOGEAR logo, MiniView, VSE are trademarks or registered trademarks of IOGEAR, Inc. Microsoft and Windows are registered trademarks of Microsoft Corporation. IBM is a registered trademark o

  • IOGear GIC704SR5W6, © 2007 IOGEAR, INC. FUN IOGEAR offers connectivity solutions that are innovative, fun, and stylish, helping people enjoy daily life using our high technology products. GREEN IOGEAR is an environmentally conscious company that emphasizes the importance of conserving natural resources. The use of our technology solutions helps reduce electronic waste. HEALTH IOGEAR supports healthy and fi t lifestyles. By integrating products with the latest scientifi c developments, IOGEAR’s solutions enhance the life of end-users. About Us About Us About Us

Related Products and Documents (PCI Card):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Hitachi Ultrastar A7K1000 Quick installation manual hitachi/ultrastar-a7k1000-ZS5.pdf 19 Nov 2022 2 0.03 Mb
2 Draytek Vigor2930 Series Operation & user’s manual draytek/vigor2930-series-43Z.pdf 09 Sep 2023 222 5.31 Mb
3 Wilson Electronics DB Pro 462105 Installation instructions manual wilson-electronics/db-pro-462105-44F.pdf 08 May 2023 15
4 Panasonic TC-29GF70R Operating instrucktions panasonic/tc-29gf70r-5HG.pdf 01 Aug 2023 38 1.57 Mb
5 FoodSaver V2222 Operation & user’s manual foodsaver/v2222-848.pdf 05 Aug 2022 17 0.82 Mb
6 ProMariner ProSport Portable Owner's manual and installation manual promariner/prosport-portable-2XI.pdf 10 Apr 2023 14

Similar Resources:

  • SIIG

    CyberPro PCI 2S

    (12 pages)
    1CyberPro PCI 2SQuick Installation Guide04-0341DIntroducing the CyberPro PCI 2SThe CyberPro PCI 2S high-speed serial I/O card providestwo additional 9-pin serial ports.Features and Benefits• Conforms to PCI v2.2 Plug and Play• Full support for Windows-based software• Reduces CPU load and improves systemperformance dramatically• IRQ sharing feature re …
  • Pentek

    7342

    (20 pages)
    Pentek Model 7342 Installation Manual Page 1Manual Part No: 800.73420 Rev: B − May 27, 2009Pentek, Inc.One Park WayUpper Saddle River, NJ 07458(201) 818−5900http://www.pentek.comCopyright © 2006 − 2009INSTALLATION MANUALMODEL 7342Multichannel Transceiver3U cPCI Board …
  • Nortel

    NT1R20

    (316 pages)
    Line cards DescriptionMeridian 1Line cards DescriptionDocument Number: 553-3001-105Document Release: Standard 5.00Date: June 1999Year Publish FCC TM© 1994, 1999All rights reservedPrinted in the United States of AmericaInformation is subject to change without notice. Nortel Networks Corpration reserves the right to make changes in design or components as pro …
  • IOGear

    GUV322

    (10 pages)
    Quick Start GuideUpstream™ Pro Dual Video Capture HubGuide de Démarrage RapideUpstream™ Pro Hub de capture vidéo doubleGuía de Inicio RápidoUpstream™ Pro Dual Hub de vídeo capturawww.iogear.comGUV322Q11634 …
  • ADS Technologies

    PTV-305

    (8 pages)
    ADS Tech Instant TV Deluxe PCI Driver Installation Guide This guide will walk you through on how to update the drivers for the Instant TV Deluxe PCI within the Device Manager. Note: to open the Device Manager window, right-click on My Computer and click on Properties. Then click on the Hardware Tab and finally on the Device Manager button. Step 1: Click o …
  • ICP DAS USA

    PISO-DA4U

    (8 pages)
    PEX-DAx/PIO-DAxU/PISO-DAxU Quick Start Guide ICP DAS CO., LTD. 1 WebSite: http:// www.icpdas.com.tw E-Mail: [email protected] , [email protected] The package includes the following items: One PEX-DA, PISO-DAxU and PIO-DAxU series board as follows: PEX-DA series: PEX-DA4, PEX-DA8, PEX-DA16 PISO-DAxU series: PISO-DA4U …

Comments, Questions and Opinions: